953 resultados para end-systolic pressure-diameter relations
Resumo:
Introduction: Chronic renal disease is associated with a high cardiovascular risk. Data from the general population associate cardiovascular diseases with low educational level, but no study has evaluated this association in patients on hemodialysis. Objective: This study aimed at evaluating the association between educational level, hypertension, and left ventricular hypertrophy in patients on chronic hemodialysis. Methods: A standard socioeconomic questionnaire was applied to 79 hemodialysis patients at the Hospital das Clínicas of Faculdade de Medicina de Botucatu, state of São Paulo. Clinical, laboratory and echocardiographic data were obtained from medical records. The patients were divided into two groups according to the median educational level, as follows: G1, patients with three or less years of schooling; G2, patients with more than three years of schooling. Results: Blood pressure, interdialytic weight gain, and variables statistically different in the two groups (p < 0.2) underwent multiple analysis. Independent associations were stated with p < 0.05 in multiple analysis. The mean age of patients was 57 ± 12.8 years, 46 were males (57%), and 53 white (67%). The variables selected for multiple analysis were: age (p = 0.004); educational level (p < 0.0001); body mass index (p = 0.124); left ventricular diameter (p = 0.048); and left ventricular mass index (p = 0.006). Antihypertensive drugs were similar in both groups. Systolic blood pressure (p = 0.006) and years of schooling (p = 0.047) had a significant and independent correlation with left ventricular mass index. Conclusion: In hemodialysis patients, left ventricular mass associated not only with blood pressure but also with educational level.
Resumo:
The objective of this dissertation is the development of a general formalism to analyze the thermodynamical properties of a photon gas under the context of nonlinear electrodynamics (NLED). To this end it is obtained, through the systematic analysis of Maxwell s electromagnetism (EM) properties, the general dependence of the Lagrangian that describes this kind of theories. From this Lagrangian and in the background of classical field theory, we derive the general dispersion relation that photons must obey in terms of a background field and the NLED properties. It is important to note that, in order to achieve this result, an aproximation has been made in order to allow the separation of the total electromagnetic field into a strong background electromagnetic field and a perturbation. Once the dispersion relation is in hand, the usual Bose-Einstein statistical procedure is followed through which the thermodynamical properties, energy density and pressure relations are obtained. An important result of this work is the fact that equation of state remains identical to the one obtained under EM. Then, two examples are made where the thermodynamic properties are explicitly derived in the context of two NLED, Born-Infelds and a quadratic approximation. The choice of the first one is due to the vast appearance in literature and, the second one, because it is a first order approximation of a large class of NLED. Ultimately, both are chosen because of their simplicity. Finally, the results are compared to EM and interpreted, suggesting possible tests to verify the internal consistency of NLED and motivating further developement into the formalism s quantum case
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Avaliar os valores de medidas ecocardiográficas em crianças eutróficas sem cardiopatia, relacionando-os com a superfície corporal (SC, m²), e construir curvas de percentis que relacionem as variáveis ecocardiográficas estudadas com a SC. MÉTODOS: Foram analisadas medidas ecocardiográficas unidimensionais de crianças entre 1 e 144 meses de idade. Avaliaram-se: diâmetros diastólicos dos ventrículos direito (VDd, mm) e esquerdo (VEd, mm), sistólico do VE (VEs, mm), da via de saída do VD (VSVD, mm), da aorta (DAo, mm) e do átrio esquerdo (DAE, mm); fração de ejeção do VE (FEVE, %); porcentagem da variação do diâmetro ventricular esquerdo (deltaVE, %); espessura diastólica do septo interventricular (ESIV, mm) e da parede posterior do VE (EPPVE, mm); massa (MVE, g) e índice de massa muscular do VE (IMVE, g/m²). RESULTADOS: Ao final do estudo, 595 crianças (326 do sexo masculino) foram avaliadas. Os valores das medidas ecocardiográficas apresentaram boa correlação com a SC e possibilitaram a construção de curvas de percentis (3%, 25%, 50%, 75% e 97%). Diferenças estatisticamente significantes, entre os sexos, foram evidenciadas para as variáveis VEs, VEd, VSVD, DAo, MVE e IMVE, sendo os maiores valores observados em crianças do sexo masculino. CONCLUSÃO: As curvas de percentis dos valores obtidas podem ser utilizadas como referência para a avaliação de crianças com suspeita de cardiopatia ou para o acompanhamento daquelas já diagnosticadas como cardiopatas ou em tratamento com agentes potencialmente cardiotóxicos.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste estudo foi medir a incidência de hipertensão arterial sistêmica em um curtume de médio porte em Botucatu, São Paulo, Sudeste do Brasil, onde havia sido observada, em estudo prévio, uma correlação positiva entre tempo de trabalho e níveis pressóricos, bem como uma alta prevalência de hipertensão. Para tanto, uma coorte de trabalhadores desse curtume foi acompanhada durante sete anos. Ao final do seguimento, estimou-se a taxa de incidência de hipertensão arterial como 0,0964.ano-1, valor considerado elevado se comparado com o encontrado em outros grupos profissionais.
Resumo:
To evaluate a prototype pressure stimulus device for use in the cat and to compare with a known thermal threshold device.Eight healthy adult cats weighing between 3.0 and 4.9 kg.Pressure stimulation was given via a plastic bracelet taped around the forearm. Three 2.4 mm diameter ball bearings, in a 10-mm triangle, were advanced against the craniolateral surface of the antebrachium by manual inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was also tested. Stimuli were stopped if they reached 55 degrees C or 450 mmHg without response. After four pressure and thermal threshold baselines, each cat received SC buprenorphine 0.01 mg kg(-1), carprofen 4 mg kg(-1) or saline 0.3 mL in a three period cross-over study with a 1-week interval. The investigator was blinded to the treatment. Measurements were made at 0.25. 0.5, 0.75, 1, 2, 3, 4, 6, 8, and 24 hours after injection. Data were analyzed by using ANOVA.There were no significant changes in thermal or pressure threshold after administration of saline or carprofen, but thermal threshold increased from 60 minutes until 8 hours after administration of buprenorphine (p < 0.05). The maximum increase in threshold from baseline (Delta T-max) was 3.5 +/- 3.1 degrees C at 2 hours. Pressure threshold increased 2 hours after administration of buprenorphine (p < 0.05) when the increase in threshold above baseline (Delta P-max) was 162 +/- 189 mmHg.This pressure device resulted in thresholds that were affected by analgesic treatment in a similar manner but to a lesser degree than the thermal method. Pressure stimulation may be a useful additional method for analgesic studies in cats.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
ObjectiveTo investigate the cardiorespiratory, nociceptive and endocrine effects of the combination of propofol and remifentanil, in dogs sedated with acepromazine.Study designProspective randomized, blinded, cross-over experimental trial.AnimalsTwelve healthy adult female cross-breed dogs, mean weight 18.4 +/- 2.3 kg.MethodsDogs were sedated with intravenous (IV) acepromazine (0.05 mg kg-1) followed by induction of anesthesia with IV propofol (5 mg kg-1). Anesthesia was maintained with IV propofol (0.2 mg kg-1 minute-1) and remifentanil, infused as follows: R1, 0.125 mu g kg-1 minute-1; R2, 0.25 mu g kg-1 minute-1; and R3, 0.5 mu g kg-1 minute-1. The same dogs were administered each dose of remifentanil at 1-week intervals. Heart rate (HR), mean arterial pressure (MAP), respiratory rate (f(R)), end tidal CO(2) (Pe'CO(2)), arterial hemoglobin O(2) saturation, blood gases, and rectal temperature were measured before induction, and 5, 15, 30, 45, 60, 75, 90, and 120 minutes after beginning the infusion. Nociceptive response was investigated by electrical stimulus (50 V, 5 Hz and 10 ms). Blood samples were collected for plasma cortisol measurements. Statistical analysis was performed by anova (p < 0.05).ResultsIn all treatments, HR decreased during anesthesia with increasing doses of remifentanil, and increased significantly immediately after the end of infusion. MAP remained stable during anesthesia (72-98 mmHg). Antinociception was proportional to the remifentanil infusion dose, and was considered satisfactory only with R2 and R3. Plasma cortisol concentration decreased during anesthesia in all treatments. Recovery was smooth and fast in all dogs.Conclusions and clinical relevanceInfusion of 0.25-0.5 mu g kg-1 minute-1 remifentanil combined with 0.2 mg kg-1 minute-1 propofol produced little effect on arterial blood pressure and led to a good recovery. The analgesia produced was sufficient to control the nociceptive response applied by electrical stimulation, suggesting that it may be appropriate for performing surgery.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement).Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested.Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio.Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)
Resumo:
The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thickness from 2 to 16 mm. Radiographs were digitized and the radiopacity of the materials was compared to that of the aluminum stepwedge using VIXWIN 2000 software in millimeters of aluminum ( mm Al). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Radiopacity values varied from 3 mm Al to 5.9 mm Al. Sealer 26 and IRM presented the highest radiopacity values (p<0.05), while white/grey MTA and Super EBA presented the lowest radiopacity values (p<0.05). The tested root- end filling materials presented different radiopacities, white/grey MTA and Super EBA being the least radiopaque materials.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)