968 resultados para electronic devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The future of elections seems to be electronic voting systems du to its advantatges over the traditional voting. Nowadays, there are some different paradigms to ensure the security and reliability of e-voting. This document is part of a wider project which presents an e-Voting platform based on elliptic curve cryptography. It uses an hybrid combination of two of the main e-Voting paradigms to guarantee privacy and security in the counting phase, these are precisely, the mixnets and the homomorphic protocols. This document is focused in the description of the system and the maths and programming needed to solve the homomorphic part of it. In later chapters, there is a comparison between a simple mixing system and our system proposal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Epinephrine autoinjector devices are used with increasing frequency to treat severe anaphylactic reactions. Accidental injection, usually involving a finger, is a potential complication. CASE PRESENTATION: A physician in a Family Practice training program accidentally injected epinephrine into his left thumb while reading the operating instructions of an autoinjector (Epipen((R))). He developed swelling, pallor, and pain in the thumb. Treatment included topical nitroglycerin, oral vasodilators and warming of the thumb. As expected, none caused an immediate response; however, after 8 hours, the thumb was pink and warm. There was full recovery 2 months after the accident. We reviewed the treatment of accidental epinephrine injection, and found that the use of parenteral adrenergic alpha blocker phentolamine would have produced immediate recovery. CONCLUSIONS: All health professionals concerned with the use of epinephrine autoinjectors should receive adequate instruction on their use. A regimen for management of accidental epinephrine injection, in particular the use of phentolamine, should be emphasized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of connections among several nuclear and electronic indexes of reactivity in the framework of the conceptual Density Functional Theory by using an expansion ofthe energy functional in terms of the total number of electrons and the normal coordinates within a canonical ensemble was derived. The relations obtained provided explicit links between important quantities related to the chemical reactivity of a system. This paper particularly demonstrates that the derivative of the electronic energy with respect to the external potential of a system in its equilibrium geometry was equal to the negative of the nuclear repulsion derivative with respect to the external potential

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron hole transfer (HT) properties of DNA are substantially affected by thermal fluctuations of the π stack structure. Depending on the mutual position of neighboring nucleobases, electronic coupling V may change by several orders of magnitude. In the present paper, we report the results of systematic QM/molecular dynamic (MD) calculations of the electronic couplings and on-site energies for the hole transfer. Based on 15 ns MD trajectories for several DNA oligomers, we calculate the average coupling squares 〈 V2 〉 and the energies of basepair triplets X G+ Y and X A+ Y, where X, Y=G, A, T, and C. For each of the 32 systems, 15 000 conformations separated by 1 ps are considered. The three-state generalized Mulliken-Hush method is used to derive electronic couplings for HT between neighboring basepairs. The adiabatic energies and dipole moment matrix elements are computed within the INDO/S method. We compare the rms values of V with the couplings estimated for the idealized B -DNA structure and show that in several important cases the couplings calculated for the idealized B -DNA structure are considerably underestimated. The rms values for intrastrand couplings G-G, A-A, G-A, and A-G are found to be similar, ∼0.07 eV, while the interstrand couplings are quite different. The energies of hole states G+ and A+ in the stack depend on the nature of the neighboring pairs. The X G+ Y are by 0.5 eV more stable than X A+ Y. The thermal fluctuations of the DNA structure facilitate the HT process from guanine to adenine. The tabulated couplings and on-site energies can be used as reference parameters in theoretical and computational studies of HT processes in DNA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparison of donor-acceptor electronic couplings calculated within two-state and three-state models suggests that the two-state treatment can provide unreliable estimates of Vda because of neglecting the multistate effects. We show that in most cases accurate values of the electronic coupling in a π stack, where donor and acceptor are separated by a bridging unit, can be obtained as Ṽ da = (E2 - E1) μ12 Rda + (2 E3 - E1 - E2) 2 μ13 μ23 Rda2, where E1, E2, and E3 are adiabatic energies of the ground, charge-transfer, and bridge states, respectively, μij is the transition dipole moments between the states i and j, and Rda is the distance between the planes of donor and acceptor. In this expression based on the generalized Mulliken-Hush approach, the first term corresponds to the coupling derived within a two-state model, whereas the second term is the superexchange correction accounting for the bridge effect. The formula is extended to bridges consisting of several subunits. The influence of the donor-acceptor energy mismatch on the excess charge distribution, adiabatic dipole and transition moments, and electronic couplings is examined. A diagnostic is developed to determine whether the two-state approach can be applied. Based on numerical results, we showed that the superexchange correction considerably improves estimates of the donor-acceptor coupling derived within a two-state approach. In most cases when the two-state scheme fails, the formula gives reliable results which are in good agreement (within 5%) with the data of the three-state generalized Mulliken-Hush model

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronic coupling Vda is one of the key parameters that determine the rate of charge transfer through DNA. While there have been several computational studies of Vda for hole transfer, estimates of electronic couplings for excess electron transfer (ET) in DNA remain unavailable. In the paper, an efficient strategy is established for calculating the ET matrix elements between base pairs in a π stack. Two approaches are considered. First, we employ the diabatic-state (DS) method in which donor and acceptor are represented with radical anions of the canonical base pairs adenine-thymine (AT) and guanine-cytosine (GC). In this approach, similar values of Vda are obtained with the standard 6-31 G* and extended 6-31++ G* basis sets. Second, the electronic couplings are derived from lowest unoccupied molecular orbitals (LUMOs) of neutral systems by using the generalized Mulliken-Hush or fragment charge methods. Because the radical-anion states of AT and GC are well reproduced by LUMOs of the neutral base pairs calculated without diffuse functions, the estimated values of Vda are in good agreement with the couplings obtained for radical-anion states using the DS method. However, when the calculation of a neutral stack is carried out with diffuse functions, LUMOs of the system exhibit the dipole-bound character and cannot be used for estimating electronic couplings. Our calculations suggest that the ET matrix elements Vda for models containing intrastrand thymine and cytosine bases are essentially larger than the couplings in complexes with interstrand pyrimidine bases. The matrix elements for excess electron transfer are found to be considerably smaller than the corresponding values for hole transfer and to be very responsive to structural changes in a DNA stack

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we report on the electronic and vibrational (hyper)polarizabilities of donor–acceptorsubstituted azobenzene. It is observed that both electronic and vibrational contributions to the electricdipole first hyperpolarizability of investigated photoactive molecule substantially depend on the conformation. The contributions to the nuclear relaxation first hyperpolarizability are found to be quite important in the case of two considered isomers (cis and trans). Although the double-harmonic term is found to be the largest in terms of magnitude, it is shown that the total value of the nuclear relaxation contribution to vibrational first hyperpolarizability is a result of subtle interplay of higher-order contributions. As a part of the study, we also assess the performance of long-range-corrected densityfunctional theory in determining vibrational contributions to electric dipole (hyper)polarizabilities. In most cases, the applied long-range-corrected exchange correlation potentials amend the drawbacks of their conventional counterparts

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, the large deployment of mobile devices has led to a massiveincrease in the volume of records of where people have been and when they were there.The analysis of these spatio-temporal data can supply high-level human behaviorinformation valuable to urban planners, local authorities, and designer of location-basedservices. In this paper, we describe our approach to collect and analyze the history ofphysical presence of tourists from the digital footprints they publicly disclose on the web.Our work takes place in the Province of Florence in Italy, where the insights on thevisitors’ flows and on the nationalities of the tourists who do not sleep in town has beenlimited to information from survey-based hotel and museums frequentation. In fact, mostlocal authorities in the world must face this dearth of data on tourist dynamics. In thiscase study, we used a corpus of geographically referenced photos taken in the provinceby 4280 photographers over a period of 2 years. Based on the disclosure of the locationof the photos, we design geovisualizations to reveal the tourist concentration and spatiotemporalflows. Our initial results provide insights on the density of tourists, the points ofinterests they visit as well as the most common trajectories they follow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alignment between competences, teaching-learning methodologies and assessment is a key element of the European Higher Education Area. This paper presents the efforts carried out by six Telematics, Computer Science and Electronic Engineering Education teachers towards achieving this alignment in their subjects. In a joint work with pedagogues, a set of recommended actions were identified. A selection of these actions were applied and evaluated in the six subjects. The cross-analysis of the results indicate that the actions allow students to better understand the methodologies and assessment planned for the subjects, facilitate (self-) regulation and increase students’ involvement in the subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

County Recorders Electronic Transaction Fees Under the Control of the State Treasurer and the Iowa County Recorders Association, Auditor of State's Report for the Period July 1, 2003 through September 30, 2005