1000 resultados para different EPM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The blue swimmer crab is a commercially important species of the tropical Indo-Pacific regions that shows substantial potential as a candidate species for aquaculture. Optimization of larval rearing conditions, including photoperiod, is therefore important to establish a method for the intensive hatchery culture of this species. Newly hatched larvae of Portunuspelagicus in first zoeal stage (ZI) were reared under five photoperiod regimes 0L: 24D, 6L: 18D, 12L: 12D, 18L: 6D, and 24L: 0D (5 replicates per treatment) till they metamorphosed to megalopae (ranged from 8.5 ± 0.3 days (18L: 6D) to 10.8 ± 1.8 days (0L: 24D) at 29 ± 1 °C). Daily, larvae of each treatment were fed an identical diet of mixed rotifer and Artemia nauplii, and the survival and molt to successive stages was monitored. Newly hatched ZI larvae of P. pelagicus could successfully develop to the megalopal stage under all tested photoperiod conditions, but we detected significant differences in survival among treatments (p & 0.05). The constant darkness treatment (0L: 24D) had the lowest (19.2 ± 7.2%, mean ± S.E.) cumulative survival from ZI to the megalopal stage, while the 18L: 6D treatment achieved the highest survival (51.2 ± 23.6%). Similarly, the photoperiod significantly affected zoeal development. Constant darkness led to the longest cumulative zoeal duration (10.8 ± 1.8 days), whereas the 18L: 6D treatment rendered the shortest larval development (8.5 ± 0.3 days). In addition, larvae reared under constant darkness resulted in the smallest megalopae (carapace length = 1.44 ± 0.09 mm) and the lowest dry weight (0.536 ± 0.188 mg). In conclusion, photoperiod significantly affected the survival, development, and growth of P. pelagicus zoeal larvae. Constant darkness led to the lowest larval survival and developmental rate, while a photoperiod regime of 18L: 6D appeared to be the most suitable condition for the rearing of zoeal larvae of P. pelagicus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different toxoplasma antigens were entrapped within liposomes and evaluated, in this form, for their ability to protect Swiss mice against toxoplasma infection: soluble tachyzoite antigen (L/TAg), tissue cyst (L/CAg), tachyzoite plus tissue cyst (L/TCAg) or purified antigen of tachyzoite (L/pTAg). The protein used in L/pTAg was purified from tachyzoites using a stage-specific monoclonal antibody which reacted at a molecular weight of 32 kD in SDS PAGE and silver stain using reduced condition. To compare the immuno-adjuvant action of liposomes and of Freund's Complete Adjuvant (FCA), another group of mice was immunized with soluble tachyzoite antigen (STAg) emulsified in FCA (FCA/TAg). Control groups were inoculated with (STAg) alone, phosphate-buffered saline (PBS), FCA with PBS (FCA/PBS) and empty liposomes (L/PBS). Mice were inoculated subcutaneously with these antigens six, four and two weeks before a challenge with 80 tissue cysts of the P strain of Toxoplasma gondii orally. All mice immunized with or without adjuvant showed a humoral response, as measured by Elisa. However, no correlation was found between antibody titer and protection against the challenge. All mice immunized with L/pTAg or L/TCAg survived (100), whereas 80% and 90% of mice from groups which received respectively PBS or FCA/PBS and L/PBS died. All mice immunized with antigens entrapped within liposomes (L/TAg, L/CAg, L/TCAg and L/pTAg) showed low numbers of intracerebral cysts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Through its life cycle from the insect vector to mammalian hosts Trypanosoma cruzi has developed clever strategies to reach the intracellular milieu where it grows sheltered from the hosts' immune system. We have been interested in several aspects of in vitro interactions of different infective forms of the parasite with cultured mammalian cells. We have observed that not only the classically infective trypomastigotes but also amastigotes, originated from the extracellular differentiation of trypomastigotes, can infect cultured cells. Interestingly, the process of invasion of different parasite infective forms is remarkably distinct and also highly dependent on the host cell type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. METHODS: Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. RESULTS: Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. SIGNIFICANCE: Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Large intrathoracic airway defects may be closed using a pedicled latissimus dorsi (LD) flap, with rewarding results. This study addresses the question of whether this holds true for extrathoracic non-circumferential tracheal defects. METHODS: A cervical segment of the trachea of 4 x 1 cm was resected in 9 white male pigs. The defect was stented with a silicone stent for 3 months and closed either by an LD flap alone (group a, n = 3), an LD flap with an attached rib segment covered by pleura (group b, n = 3), or an LD flap reinforced by a perforated polylactide (MacroPore) plate (group c, n = 3). The trachea was assessed by rigid endoscopy at 3 and 4 months and histologically at 4 months postoperatively. RESULTS: The degree of stenosis at the level of the reconstruction at 4 months was 25, 50 and 75% in group a, 15, 50 and 60% in group b, and 20, 95 and 95% in group c, respectively. The percentage of the defect covered by columnar epithelium was 100% in all animals of group a, 60, 100 and 100% in group b, and 10, 0 and 0% in group c. Resorption of the rib was seen in all animals of group b and obstructive inflammatory polyps were found in 2 animals of group c. CONCLUSION: Pedicled LD flaps provided less satisfactory results for closure of large non-circumferential extrathoracic airway defects than observed after intrathoracic reconstruction. A pedicled rib segment added to the LD flap did not improve the results obtained from LD flap repair alone, and an embedded MacroPore prosthesis may result in severe airway stenosis due to plate migration and intense inflammatory reaction protruding into the tracheal lumen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using phenotype techniques, characterization was made to species and serovar of 3,112 strains of Listeria, isolated from different sources of infection such as human (247-7.9%) and animals (239-7.6%), as well as from various routes of infection, including food (2,330-74.8%) and environmental constituents (296-9.5%), all coming from different regions of the country and collected during the period 1971-1997. The following species were recovered in the cultures analysed: L. monocytogenes (774-24.8%), L. innocua (2,269-72.9%), L. seeligeri (37-1.1%), L. welshimeri (22-0.7%), L. grayi (9-0.2%), and L. ivanovii (1-0.03%). L. monocytogenes was represented by ten serovars, the most prevalent being 4b (352-11.3%), 1/2a (162-5.2%), and 1/2b (148-4.7%). The predominant serovar in L. innocua was 6a (2,093-67.2%). Considerations about laboratory methods for diagnosis and epidemiological aspects are presented on the basis of the results obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vector competence of Culex quinquefasciatus from five localities in Brazil to Dirofilaria immitis was evaluated experimentally. Females from each locality were fed on an infected dog (~ 6 microfilariae/µl blood). A sample of blood fed mosquitoes were dissected approximately 1 h after blood meal. These results demonstrated that all had ingested microfilariae (mean, 4.8 to 24.6 microfilariae/mosquito). Fifteen days after the infected blood meal, the infection and infective rates were low in all populations of Cx. quinquefasciatus. The mean number of infective larvae detected in the head and proboscis of these mosquitoes was 1-1.5. The vector efficiency, the number of microfilariae ingested/number of infective larvae, was low for all populations of Cx. quinquefasciatus. However, the survival rate for all populations was high (range 50-75%). The survival rate of Aedes aegypti assayed simultaneously for comparison was low (24.7%), while the vector efficiency was much higher than for Cx. quinquefasciatus. These data suggest that the vector competence of all assayed populations of Cx. quinquefasciatus to D. immitis in Brazil is similar and that this species is a secondary vector due to its low susceptibility. Nevertheless, vector capacity may vary between populations due to differences in biting frequency on dogs that has been reported in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of acid fast bacilli in multiple specimens was investigated comparatively with Ziehl-Neelsen (ZN) and fluorescence microscopy (FM) staining in order to determine sensitivity in detecting tuberculosis (TB). A total of 465 specimens obtained from 295 patients were analysed at Harran University Medical School Hospital between March 1998 and March 2000. The culture was employed as the reference method. Sixty-eight patients (23.1%) were diagnosed as having TB by culture. The ZN and FM staining sensitivities were 67.6% (46/68) and 85.2% (58/68) respectively. Two hundred and one patients (68.1%) submitted one specimen to the laboratory. TB positivity was detected in 42 (20.9%) of these patients by culture. The sensitivities of ZN and FM stains were found to be 61% and 83% in these patients. However, in 18 patients (6.1%) who submitted two specimens to the laboratory, the TB was positive in six of them (33.3%) and ZN and FM sensitivities were 66% and 83% respectively. When three specimens or more were collected from the patients (76 patients, 25.8%), TB positivity was determined in 20 of them (26.3%) and the sensitivities were 80% and 92% in the ZN- and FM-stained smears, respectively. Our data indicate that in the diagnosis of TB, FM has greater sensitivity than ZN. In particular, in the case of a single specimen, the diagnostic value of FM is quite significant. It is, therefore, possible to conclude that both ZN and FM staining can be used for the diagnosis of TB when there are more than two specimens. However, if only one or two specimens are available, FM staining is preferable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the impact of admission to different hospital types on early and 1-year outcomes in patients with acute coronary syndrome (ACS). Between 1997 and 2009, 31 010 ACS patients from 76 Swiss hospitals were enrolled in the AMIS Plus registry. Large tertiary institutions with continuous (24 hour/7 day) cardiac catheterisation facilities were classified as type A hospitals, and all others as type B. For 1-year outcomes, a subgroup of patients admitted after 2005 were studied. Eleven type A hospitals admitted 15987 (52%) patients and 65 type B hospitals 15023 (48%) patients. Patients admitted into B hospitals were older, more frequently female, diabetic, hypertensive, had more severe comorbidities and more frequent non-ST segment elevation (NSTE)-ACS/unstable angina (UA). STE-ACS patients admitted into B hospitals received more thrombolysis, but less percutaneous coronary intervention (PCI). Crude in-hospital mortality and major adverse cardiac events (MACE) were higher in patients from B hospitals. Crude 1-year mortality of 3747 ACS patients followed up was higher in patients admitted into B hospitals, but no differences were found for MACE. After adjustment for age, risk factors, type of ACS and comorbidities, hospital type was not an independent predictor of in-hospital mortality, in-hospital MACE, 1-year MACE or mortality. Admission indicated a crude outcome in favour of hospitalisation during duty-hours while 1-year outcome could not document a significant effect. ACS patients admitted to smaller regional Swiss hospitals were older, had more severe comorbidities, more NSTE-ACS and received less intensive treatment compared with the patients initially admitted to large tertiary institutions. However, hospital type was not an independent predictor of early and mid-term outcomes in these patients. Furthermore, our data suggest that Swiss hospitals have been functioning as an efficient network for the past 12 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.