991 resultados para diagnostic tools
Resumo:
The Work Package 4 of the ORAMED project, a collaborative project (2008-11) supported by the European Commission within its seventh Framework Programme, is concerned with the optimisation of the extremity dosimetry of medical staff in nuclear medicine. To evaluate the extremity doses and dose distributions across the hands of medical staff working in nuclear medicine departments, an extensive measurement programme has been started in 32 nuclear medicine departments in Europe. This was done using a standard protocol recording all relevant information for radiation exposure, i.e. radiation protection devices and tools. This study shows the preliminary results obtained for this measurement campaign. For diagnostic purposes, the two most-used radionuclides were considered: (99m)Tc and (18)F. For therapeutic treatments, Zevalin(®) and DOTATOC (both labelled with (90)Y) were chosen. Large variations of doses were observed across the hands depending on different parameters. Furthermore, this study highlights the importance of the positioning of the extremity dosemeter for a correct estimate of the maximum skin doses.
Resumo:
This review describes some dysimmune neuromuscular disorders and their recent management: syndrome of peripheral nerve hyperexcitability (treatment of cramps, immunosuppressors); Guillain-Barré syndrome (new mechanisms and consensus treatment); chronic inflammatory demyelinating polyradiculoneuropathy (new indication for the use of pulse dexamethasone, new scores of activity); importance of subcutaneous immunoglobulin in multifocal motor neuropathy and of infusions of rituximab in myasthenia gravis; new entities in myositis and their treatment.
Resumo:
The effective dose delivered to the patient was determined, by modeling, for 257 types of examinations covering the different modalities of diagnostic and interventional radiology. The basic operational dosimetric quantities considered were obtained from the parameters of the examinations on the basis of dosimetric models. These models required a precise characterization of each examination. The operational dosimetric quantities were converted into doses to organs and effective doses using appropriate conversion factors. The determination of the collective effective dose to the Swiss population requires a number of corrections to account for the variability of several parameters: sensitivity of the detection system, age, gender, and build of the patient. The use of various dosimetric models is illustrated in this paper for a limited number of examination types covering the different radiological modalities, for which the established typical effective doses are given. With regard to individual doses, the study indicated that the average effective doses per type of examination can be classified into three levels: (a) the weakly irradiating examinations (less than 0.1 mSv), which represent 78% of the examinations and 4% of the collective dose, (b) the moderately irradiating examinations (between 0.1 mSv and 10 mSv), which represent 21% of the examinations and 72% of the collective dose, (c) the strongly irradiating examinations (more than 10 mSv), which represent 1% of the examinations and 24% of the collective dose.
Resumo:
The aim of this research was to evaluate how fingerprint analysts would incorporate information from newly developed tools into their decision making processes. Specifically, we assessed effects using the following: (1) a quality tool to aid in the assessment of the clarity of the friction ridge details, (2) a statistical tool to provide likelihood ratios representing the strength of the corresponding features between compared fingerprints, and (3) consensus information from a group of trained fingerprint experts. The measured variables for the effect on examiner performance were the accuracy and reproducibility of the conclusions against the ground truth (including the impact on error rates) and the analyst accuracy and variation for feature selection and comparison.¦The results showed that participants using the consensus information from other fingerprint experts demonstrated more consistency and accuracy in minutiae selection. They also demonstrated higher accuracy, sensitivity, and specificity in the decisions reported. The quality tool also affected minutiae selection (which, in turn, had limited influence on the reported decisions); the statistical tool did not appear to influence the reported decisions.
Resumo:
Modèle de diagnostic C4.1.1 (UPC)
Resumo:
Modèle de disgnostic C4.1.2 (UPC)
Resumo:
The calculation of elasticity parameters by sonic and ultra sonic wave propagation in saturated soils using Biot's theory needs the following variables : forpiation density and porosity (p, ø), compressional and shear wave velocities (Vp, Vs), fluid density, viscosity and compressibility (Pfi Ilfi Ki), matrix density and compressibility (p" K), The first four parameters can be determined in situ using logging probes. Because fluid and matrix characteristics are not modified during core extraction, they can be obtained through laboratory measurements. All parameters necessitate precise calibrations in various environments and for specific range of values encountered in soils. The slim diameter of boreholes in shallow geophysics and the high cost of petroleum equipment demand the use of specific probes, which usually only give qualitative results. The measurement 'of density is done with a gamma-gamma probe and the measurement of hydrogen index, in relation to porosity, by a neutron probe. The first step of this work has been carried out in synthetic formations in the laboratory using homogeneous media of known density and porosity. To establish borehole corrections different casings have been used. Finally a comparison between laboratory and in situ data in cored holes of known geometry and casing has been performed.
Resumo:
Pyoderma gangrenosum is a rare ulcerative disease associated with inflammatory bowel disease, arthritis or haematological malignancies. The diagnosis of Pyoderma gangrenosum is often delayed while consideration is given to the more likely diagnoses of wound breakdown or bacterial infection. The outcome depends on early diagnosis and on excellent collaboration between the surgical team and the infectious disease specialist. We present two puzzling cases of Pyoderma gangrenosum and discuss the physiopathology, the diagnosis strategy and the management. Le Pyoderma gangrenosum constitue une entité clinique méconnue, se présentant classiquement par des ulcérations cutanées inflammatoires et douloureuses. Le contexte clinique retrouve fréquemment une pathologie inflammatoire digestive, une néoplasie ou une atteinte rhumatologique concomitante. Le diagnostic est trop souvent tardif, après de multiples traitements antibiotiques et chirurgicaux, et nécessite une excellente coordination entre le médecin traitant, les équipes chirurgicales et les spécialistes des maladies infectieuses. Au travers de deux cas spectaculaires, nous rappelons quelques notions de base sur la physiopathologie, la présentation clinique et la prise en charge du Pyoderma gangrenosum.
Resumo:
In recent years many clinical prediction rules (CPR) have been developed. Before a CPR can be used in clinical practice, different methodical steps are necessary, from the development of the score, the internal and external validation to the impact study. Before using a CPR in daily practice family doctors have to verify how the rules have been developed and whether this has been done in a population similar to the population in which they would use them. The aim of this paper is to describe the development of a CPR, and to discuss advantages and risks related to the use of CPR in order to help family doctors in their choice of scores for use in their daily practice.
Resumo:
Toperform a meta-analysis of FDG-PET performances in the diagnosis of largevessels vasculitis (Giant Cell Arteritis (GCA) associated or not withPolymyalgia Rheumatica(PMR), Takayasu). Materials and methods : The MEDLINE,Cochrane Library, Embase were searched for relevant original articlesdescribing FDG-PET for vasculitis assessment, using MesH terms ("GiantCell Arteritis or Vasculitis" AND "PET"). Criteria for inclusionwere:(1)FDG-PET for diagnosis of vasculitis(2)American College of Rheumatologycriteria as reference standard(3)control group. After data extraction, analyseswere performed using a random-effects model. Results : Of 184 citations(database search and references screening),70 articles were reviewed of which12 eligible studies were extracted (sensitivity range from 32% to 97%). 7studies fulfilled all inclusion criteria. Owing to overlapping population, 1study was excluded. Statistical heterogeneity justified the random-effectsmodel. Pooled 6 studies analysis(116 vasculitis,224 controls) showed a 81%sensitivity (95%CI:70-89%);a 89% specificity (95%CI:77-95%);a 85%PPV(95%CI:63-95%); a 90% NPV(95%CI:79-95%);a 7.1 positive LR(95%CI:3.4-14.9); a0.2 negative LR(95%CI:0.14-0.35) and 90.1 DOR(95%CI: 18.6-437). Conclusion :FDG-PET has good diagnostic performances in the detection of large vesselsvasculitis. Its promising role could be extended to follow up patients undertreatment, but further studies are needed to confirm this possibility.
Resumo:
Mirja Ruohoniemi