931 resultados para detection method
Resumo:
Ivermectin, a member of the avermectin group, is frequently used to control parasites in many food producing animal species. A method for the detection and quantification of ivermectin residues in bovine liver has been developed. Liver samples (4 g) were extracted with acetonitrile and applied to a competitive enzyme immunoassay using a polyclonal antiserum raised in rabbits against an ivermectin-transferrin conjugate, The limit of detection of the assay (mean +/- 3s) calculated from the analysis of 24 known negative samples was 1.6 ng g(-1), Intra- and inter-assay RSDs were determined as 8.8 and 14.6%, respectively, using a negative bovine liver sample fortified with 100 ng g(-1) of ivermectin. Four Friesian steers were treated with a pour-on application of ivermectin at a dose rate of 0.5 mg kg(-1) body mass then withdrawn and killed at 7, 14, 21 and 28 d, Livers mere removed and ivermectin residue concentrations determined using the proposed immunoassay procedure, Seven days post-treatment the ivermectin liver concentration was determined as 52.7 ng g(-1), decreasing to 4.1 ng(-1) at 28 d, All immunoassay results were confirmed using high-performance liquid chromatography (HPLC), The immunoassay and HPLC results for invermectin ranged from 1 to 58 ng g(-1) and were in close correlation (r = 0.99).
Resumo:
A new competitive enzyme immunoassay technique has been developed for the determination of concentrations of the trypanocidal drug isometamidium chloride (Samorin) in bovine serum. The method has been shown to be highly repeatable and reproducible, and it has several advantages over previous immunoassay techniques for the drug. There are fewer incubation steps overall; microtitre plates may be of coated in batches and stored frozen for future use; and the competition incubation is overnight and is followed only by a brief colour development stage of 10 min. Coefficients of variation (CVs) of duplicate samples were similar to 5%, and mean response variances of untreated cattle (n = 57) were small (CV, 10%). Partitioning of variance showed 77% of this variability to be intrinsic to the samples, and the remaining 23% was due to the procedure. The limit of detection was approximately 0.5 ng ml(-1), which was considered to be satisfactory for the intended use of the method. The drug could be detected in serum of treated cattle for up to 10 weeks following treatment, and determinations showed a high level of reproducibility.
Resumo:
A gas chromatographic/mass spectrometric method is described for the detection of clenbuterol residues in liver, muscle, urine and retina. Tissue samples are first digested using protease and any clenbuterol present is extracted using a simple liquid/liquid extraction procedure. The dried extracts are then derivatized using methylboronic acid and the derivatives are subjected to gas chromatography/mass spectrometry on a magnetic sector instrument. The detection limit of the assay is 0.05 ng g-1 clenbuterol in liver, muscle or urine using a 10 g sample size, and 4 ng g-1 in retina using a 0.5 g sample size. The assay is made very specific by using selected ion monitoring of three ions at a resolution of 3500 and by ion ratio measurements. The precision and reproducibility of the assay are enhanced by the use of a deuterated internal standard, with a typical coefficient of variation of 3%.
Resumo:
Background: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probebased real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. Methods/design: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. Dissemination: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care.
Resumo:
A method is described for the quantitative confirmation of 4,4'-dinitrocarbanilide (DNC), the marker residue for nicarbazin in chicken liver and eggs. The method is based on LC coupled to negative ion electrospray MS-MS of tissue extracts prepared by liquid-liquid extraction. The [M-H](-) ion at m/z 301 is monitored along with two transition ions at m/z 137 and 107 for DNC and the [M-H](-) ion at m/z 309 for the internal standard, d(8)-DNC. The method has been validated according to the new EU criteria for the analysis of veterinary drug residues at 100, 200 and 300 mug kg(-1) in liver and at 10, 30 and 100 mug kg(-1) in eggs. Difficulties concerning the application of the new analytical limits, namely the decision limit (CC) and the detection capability (CC) to the determination of DNC in both liver and eggs are discussed.
Resumo:
In this study the design and development of two real-time PCR assays for the rapid, sensitive and specific detection of infectious laryngotracheitis virus (ILTV) DNA is described. A Primer-Probe Energy Transfer (PriProET) assay and 5' conjugated Minor Groove Binder (MGB) method are compared and contrasted. Both have been designed to target the thymidine kinase gene of the ILTV genome. Both PriProET and MGB assays are capable of detecting 20 copies of a DNA standard per reaction and are linear from 2 x 10(8) to 2 x 10(2) copies/mu l. Neither PriProET, nor MGB reacted with heterologous herpesviruses, indicating a high specificity of the two methods as novel tools for virus detection and identification. This study demonstrates the suitability of PriProET and 5' conjugated MGB probes as real-time PCR chemistries for the diagnosis of respiratory diseases caused by ILTV. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
For the first time, a simple and validated reversed-phase liquid chromatography (RP-LC) with fluorescence detection has been developed for the simultaneous analysis of glutamate (Glu), ?-aminobutyric acid (GABA), glycine (Gly) and taurine (Tau) in Wistar and tremor rats brain synaptosomes. The samples were separated on a C18 analytical column with gradient elution of methanol and 0.1 mol L-1 potassium acetate at a flow rate of 1 mL min-1. Total run time was approximately 25 min. All calibration curves exhibited good linearity (r 2 > 0.999) within test ranges. The reproducibility was estimated by intra-and inter-day assays and RSD values were less than 2.48%. The recoveries were between 96.32 and 105.21%. The method was successfully applied to the quantification of amino acids in Wistar and tremor rats brain synaptosomes. Through this developed protocol, the levels of Glu in hippocampal and prefrontal cortical synaptosomes of tremor rats were both significantly elevated than those of adult Wistar rats whereas significantly decreased concentrations of GABA and Gly were observed in the hippocampal region of tremor rats without evident difference in the prefrontal cortex between experimental and control groups. In addition, our studies also showed a marked elevation of Tau in tremor rats hippocampal synaptosomes although there was no pronounced difference in the prefrontal cortical region of Wistar and tremor rats.
Resumo:
Color segmentation of images usually requires a manual selection and classification of samples to train the system. This paper presents an automatic system that performs these tasks without the need of a long training, providing a useful tool to detect and identify figures. In real situations, it is necessary to repeat the training process if light conditions change, or if, in the same scenario, the colors of the figures and the background may have changed, being useful a fast training method. A direct application of this method is the detection and identification of football players.
Resumo:
Circulating antigliadin antibody has been described in patients with gluten enteropathy although the prevalence varies in different studies. It has been suggested that the investigation for antigliadin antibody might be useful as a screening test. The object of the present study was to evaluate two different techniques for assaying these antibodies - an indirect immunofluorescent method and an enzyme-linked immunosorbent assay (ELISA). Antibodies were assayed in the sera of 102 patients in whom jejunal biopsies were also obtained. The specificity of both tests was greater than 95%, and the correlation between the presence of antibody and histology was significant (p <0.005), though the sensitivity of each test was less than 70%.
Resumo:
A replica plate screening technique, based on the acid molybdate assay for detection of phosphate has been developed to permit the detection of microorganisms capable of mineralizing organophosphonates. The method was further adapted as the basis of an activity stain for the detection of the carbon - phosphorus bond cleavage enzyme phosphonoacetate hydrolase in PAGE gels.
Resumo:
Paralytic shellfish poisoning is a toxic syndrome described in humans following the ingestion of seafood contaminated with saxitoxin and/or its derivatives. The presence of these toxins in shellfish is considered an important health threat and their levels in seafood destined to human consumption are regulated in many countries, as well as the levels of other chemically unrelated toxins. We studied the feasibility of immunodetection of saxitoxin and its analogs using a solid-phase microsphere assay coupled to flow cytometry detection in a Luminex 200 system. The technique consists of a competition assay where the toxins in solution compete with bead-bound saxitoxin for binding to an antigonyautoxin 2/3 monoclonal antibody (GT-13A). The assay allowed the detection of saxitoxin both in buffer and mussel extracts in the range of 2.2-19.7 ng/mL (IC(20)-IC(80)). Moreover, the assay cross-reactivity with other toxins of the group is similar to previously published immunoassays, with adequate detection of most analogs except N-1 hydroxy analogs. The recovery rate of the assay for saxitoxin was close to 100%. This microsphere-based immunoassay is suitable to be used as a screening method, detecting saxitoxin from 260 to 2360 µg/kg. This microsphere/flow cytometry system provided similar sensitivities to previously published immunoassays and provides a solid background for the development of easy, flexible multiplexing of toxin detection in one sample.
Resumo:
Coccidiostats are the only veterinary drugs still permitted to be used as feed additives to treat poultry for coccidiosis. To protect consumers, maximum levels for their presence in food and feed have been set by the European Union (EU). To monitor these coccidiostats, a rapid and inexpensive screening method would be a useful tool. The development of such a screening method, using a flow cytometry-based immunoassay, is described. The assay uses five sets of colour-coded paramagnetic microspheres for the detection of six selected priority coccidiostats. Different coccidiostats, with and without carrier proteins, were covalently coupled onto different bead sets and tested in combination with polyclonal antisera and with a fluorescent-labelled secondary antibody. The five optimal combinations were selected for this multiplex and a simple-to-use sample extraction method was applied for screening blank and spiked eggs and feed samples. A very good correlation (r ranging from 0.995 to 0.999) was obtained with the responses obtained in two different flow cytometers (Luminex 100 and FLEXMAP 3D). The sensitivities obtained were in accordance with the levels set by the EU as the measured limits of detection for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (4,4'-dinitrocarbanilide) and monensin in eggs were 0.01, 0.1, 0.5, 53 and 0.1 µg/kg and in feed 0.1, 0.2, 0.3, 9 and 1.5 µg/kg, respectively.
Resumo:
The limitations of classical diagnostic methods for invasive Candida infections have led to the development of molecular techniques such as real-time PCR to improve diagnosis. However, the detection of low titres of Candida DNA in blood from patients with candidaemia requires the use of extraction methods that efficiently lyse yeast cells and recover small amounts of DNA suitable for amplification. In this study, a Candida-specific real-time PCR assay was used to detect Candida albicans DNA in inoculated whole blood specimens extracted using seven different extraction protocols. The yield and quality of total nucleic acids were estimated using UV absorbance, and specific recovery of C. albicans genomic DNA was estimated quantitatively in comparison with a reference (Qiagen kit/lyticase) method currently in use in our laboratory. The extraction protocols were also compared with respect to sensitivity, cost and time required for completion. The TaqMan PCR assay used to amplify the DNA extracts achieved high levels of specificity, sensitivity and reproducibility. Of the seven extraction protocols evaluated, only the MasterPure yeast DNA extraction reagent kit gave significantly higher total nucleic acid yields than the reference method, although nucleic acid purity was highest using either the reference or YeaStar genomic DNA kit methods. More importantly, the YeaStar method enabled C. albicans DNA to be detected with highest sensitivity over the entire range of copy numbers evaluated, and appears to be an optimal method for extracting Candida DNA from whole blood.
Resumo:
Seismic geophysical methods have rarely been used in precision agriculture, predominantly due to the perception that they are slow and results require a complex evaluation. This paper explores the possibility of using a recently developed surface wave seismic geophysical approach, the multichannel analysis of surface waves (MASW) method, for assessment of agricultural compaction. This approach has the advantage of being non-intrusive, rapid and is able to produce 2D ground models with a relatively high density of spatial sampling points. The method, which was tested on a research site in Oakpark, Ireland, detected a significant difference in shear wave velocity between a heavily compacted headland and an uncompacted location. The results from this approach compared favourably with those obtained
from measurements of bulk density and penetrometer resistance and demonstrate that the MASW approach can distinguish between the extreme states of heavily compacted and uncompacted soil.
Resumo:
Essential to the conduct of epidemiologic studies examining aflatoxin exposure and the risk of heptocellular carcinoma, impaired growth, and acute toxicity has been the development of quantitative biomarkers of exposure to aflatoxins, particularly aflatoxin B-1. In this study, identical serum sample sets were analyzed for aflatoxin-albumin adducts by ELISA, high-performance liquid chromatography (HPLC) with fluorescence detection (HPLC-f), and HPLC with isotope dilution mass spectrometry (IDMS). The human samples analyzed were from an acute aflatoxicosis outbreak in Kenya in 2004 (n = 102) and the measured values ranged from 0.018 to 67.0, nondetectable to 13.6, and 0.002 to 17.7 ng/mg albumin for the respective methods. The Deming regression slopes for the HPLC-f and ELISA concentrations as a function of the IDMS concentrations were 0.71 (r(2) = 0.95) and 3.3 (r(2) = 0.96), respectively. When the samples were classified as cases or controls, based on clinical diagnosis, all methods were predictive of outcome (P < 0.01). Further, to evaluate assay precision, duplicate samples were prepared at three levels by dilution of an exposed human sample and were analyzed on three separate days. Excluding one assay value by ELISA and one assay by HPLC-f, the overall relative SD were 8.7%, 10.5%, and 9.4% for IDMS, HPLC-f, and ELISA, respectively. IDMS was the most sensitive technique and HPLC-f was the least sensitive method. Overall, this study shows an excellent correlation between three independent methodologies conducted in different laboratories and supports the validation of these technologies for assessment of human exposure to this environmental toxin and carcinogen.