852 resultados para city breaks
Resumo:
São Paulo is one of Latin America’s most modern and developed cities, yet around one-third of its 10 million inhabitants live in poor-quality housing in sub-standard settlements. This paper describes the response of the São Paulo municipal government that took office in 2001. Through its Secretariat of Housing and Urban Development, it designed a new policy framework with a strong emphasis on improving the quantity and quality of housing for low-income groups. Supported by new legislation, financial instruments and partnerships with the private sector, the mainstays of the new policy are integrated housing and urban development, modernization of the administrative system, and public participation in all decision-making and implementation processes. The programmes centre on upgrading and legalizing land tenure in informal settlements, and regeneration of the city centre. The new focus on valuing the investments that low-income groups have already made in their housing and settlements has proved to be more cost-effective than previous interventions, leading to improvements on an impressive scale.
Resumo:
Office returns in the City of London are more volatile than in other UK markets. This volatility may reflect fluctuations in capital flows associated with changing patterns of ownership and the growing linkage between real estate and financial markets in the City. Using current and historical data, patterns of ownership in the City are investigated. They reveal that overseas ownership has grown markedly since 1985, that owners are predominantly FIRE-sector firms and that there are strong links between ownership and occupation. This raises concerns about future volatility and systemic risk in a market strongly influenced by the cyclical behaviour and shocks of the international financial system.
Resumo:
This paper sets out progress during the first eighteen months of doctoral research into the City of London office market. The overall aim of the research is to explore relationships between office rents and the economy in the UK over the last 150 years. To do this, a database of lettings has been created from which a long run index of City office rents can be constructed. With this index, it should then be possible to analyse trends in rents and relationships with their long run determinants. The focus of this paper is on the creation of the rent database. First, it considers the existing secondary sources of long run rental data for the UK. This highlights a lack of information for years prior to 1970 and the need for primary data collection if earlier periods are to be studied. The paper then discusses the selection of the City of London and of the time period chosen for research. After this, it describes how a dataset covering the period 1860-1960 has been assembled using the records of property companies active in the City office market. It is hoped that, if successful, this research will contribute to existing knowledge on the long run characteristics of commercial real estate. In particular, it should add a price dimension (rents) to the existing long run information on stock/supply and investment. Hence, it should enable a more complete picture of the development and performance of commercial real estate through time to be gained.
Resumo:
Office returns in the City of London are more volatile than in other UK markets. This volatility may reflect fluctuations in capital flows associated with changing patterns of ownership and the growing linkage between real estate and financial markets in the City. Using current and historical data, patterns of ownership in the City are investigated. They reveal that overseas ownership has grown markedly since 1985, that owners are predominantly FIRE sector firms and that there are strong links between ownership and occupation. This raises concerns about future volatility and systemic risk.
Resumo:
Although the compact city is widely promoted as a sustainable form of urban development, little attention has been paid to the feasilibity of its implementation in practice. This paper addresses this isse by presenting the findings of a questionnaire study into the viability of the compact city from the perspective of the volume housebuilder. The study shows that, although well aware of the inherent problems witht the compact city, most were generally positive about the need to redirect more development back into urban areas. In addition, they suggested a large number of strategies for change, including i) a role for public sector agencies in overcoming the condstraints on urban sites; ii) the need for an upward reveision of acceptable densities in local plans and design guides; and iii) the creation of a separate, or revised, Use Class Order to enable mixed use development to compete on a level playing field. It is concluded that the residential developer could be engaged in the process of urban containment provided proposals for implementing the compact city of devised. The need for continuing research to test the actual effects of specific schemes is emphasised.
Resumo:
Carbon monoxide (CO) concentration data from 1999–2006, monitored at 5 different pollution stations in a high-rise mega city (Hong Kong), were collected and investigated. The spatio-temporal characteristics of urban CO concentration profiles were obtained. A new approach was put forward to examine the relationship between urban CO concentration and different wind flow patterns. Rather than relying on the meteorological data from a single weather station, usually adopted in previous studies, four weather stations on the boundary of Hong Kong territory were used in the present study so as to identify 16 different wind flow patterns, among which a typical urban heat island circulation (UHIC) can be distinguished. Higher concentrations were observed to be associated with the flow pattern of an inflow from Lau Fau Shan (LFS) station which is located in the northwest of Hong Kong. This suggests that the ability of dilution for north-to-west wind is relatively weak due to the pollutants carried from outside Hong Kong. The effectiveness of wind speed on the alleviation of urban concentration is dependent on the initial concentration of the approaching wind. The increase of wind speed of north-to-west wind from 0 m/s to 6 m/s has little effect on the reduction of urban CO concentration, especially on the non-roadside stations. By contrast, for the southerly marine wind, pollution concentration decreases sharply with an increase in the wind speed. It was also found that urban heat island circulation (UHIC) is conducive of the accumulation of pollutants, especially at night. There exists a positive correlation between CO concentration and UHI intensity. This correlation is much stronger at night compared to during the day. Keywords: urban pollution monitoring, urban ventilation pattern, urban heat island circulation, mega city
Resumo:
This paper reports the results of a parametric CFD study on idealized city models to investigate the potential of slope flow in ventilating a city located in a mountainous region when the background synoptic wind is absent. Examples of such a city include Tokyo in Japan, Los Angeles and Phoenix in the US, and Hong Kong. Two types of buoyancy-driven flow are considered, i.e., slope flow from the mountain slope (katabatic wind at night and anabatic wind in the daytime), and wall flow due to heated/cooled urban surfaces. The combined buoyancy-driven flow system can serve the purpose of dispersing the accumulated urban air pollutants when the background wind is weak or absent. The microscopic picture of ventilation performance within the urban structures was evaluated in terms of air change rate (ACH) and age of air. The simulation results reveal that the slope flow plays an important role in ventilating the urban area, especially in calm conditions. Katabatic flow at night is conducive to mitigating the nocturnal urban heat island. In the present parametric study, the mountain slope angle and mountain height are assumed to be constant, and the changing variables are heating/cooling intensity and building height. For a typical mountain of 500 m inclined at an angle of 20° to the horizontal level, the interactive structure is very much dependent on the ratio of heating/cooling intensity as well as building height. When the building is lower than 60 m, the slope wind dominates. When the building is as high as 100 m, the contribution from the urban wall flow cannot be ignored. It is found that katabatic wind can be very beneficial to the thermal environment as well as air quality at the pedestrian level. The air change rate for the pedestrian volume can be as high as 300 ACH.