914 resultados para carpal joint


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anxiety disorders are often associated with several non-psychiatric medical conditions. Among the clinical conditions found in association with anxiety stands out the joint hypermobility (JH). OBJECTIVES: To carry out a systematic review of the clinical association between anxiety disorders and JH. METHOD: A survey was conducted in MEDLINE, PsychINFO, LILACS e SciELO databases up to December 2011. We searched for articles using the keywords 'anxiety', 'joint' and 'hypermobility' and Boolean operators. The review included articles describing empirical studies on the association between JH and anxiety. The reference lists of selected articles were systematically hand-searched for other publications relevant to the review. RESULTS: Seventeen articles were included in the analysis and classified to better extract data. We found heterogeneity between the studies relate to the methodology used. Most of the studies found an association between anxiety features and JH. Panic disorder/agoraphobia was the anxiety disorder associated with JH in several studies. Etiological explanation of the relationship between anxiety and JH is still controversial. CONCLUSION: Future research in large samples from the community and clinical setting and longitudinal studies of the association between anxiety and HA and the underlying biological mechanisms involved in this association are welcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liberalism and Marxism are two schools of thought which have left deep imprints in sociological, political and economic theory. They are usually perceived as opposite, rival approaches. In the field of democracy there is a seemingly insurmountable rift around the question of political versus economic democracy. Liberals emphasize the former, Marxists the latter. Liberals say that economic democracy is too abstract and fuzzy a concept, therefore one should concentrate on the workings of an objective political democracy. Marxists insist that political democracy without economic democracy is insufficient. The article argues that both propositions are valid and not mutually exclusive. It proposes the creation of an operational, quantifiable index of economic democracy that can be used alongside the already existing indexes of political democracy. By using these two indexes jointly, political and economic democracy can be objectively evaluated. Thus, the requirements of both camps are met and maybe a more dialogical approach to democracy can be reached in the debate between liberals and Marxists. The joint index is used to evaluate the levels of economic and political democracy in the transition countries of Eastern Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] OBJECTIVE: Our hypothesis is that sonography performed by the rheumatologist in patients with suspected carpal tunnel syndrome (CTS) has higher diagnostic value compared to physical evaluation. METHODS: Adult patients with suspected idiopathic CTS, defined by sensory symptoms over the distribution of the median nerve with or without positive results with the Phalen and/or the Tinel's maneuvers were included. The diagnosis of CTS was indicated by typical symptoms daily for at least 3 months and a positive nerve conduction study. One rheumatologist unaware of the clinical and electrodiagnostic results performed an ultrasound examination of the median nerve for the area ranging from the inlet to the outlet of the carpal tunnel. Mean cross-sectional area at each level, flattening ratio and bowing of flexor retinaculum were obtained. RESULTS: Sixty-eight patients with 105 affected wrists were examined. Tinel's and Phalen's signs had a closer sensitivity (73% and 67% respectively) and specificity (40% and 30% respectively). The best swelling nerve cut-off by sonography was 9.7 mm2 at the tunnel inlet, with a sensitivity of 86%, a specificity of 48% and accuracy of 77%. A 100% positive predictive value was reached with a cross-sectional area of 13 mm2, involving 33 hands (31% of the whole sample). Maximal cross sectional area and the measurement of flexor retinaculum had an accuracy of 72% and 73% respectively. Combination of physical maneuvers and sonography not yielded more accuracy than cross-sectional area itself. CONCLUSION: In patients with clinical history of idiopathic CTS and positive nerve conduction study, sonography performed by the rheumatologist has higher diagnostic value than physical maneuvers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] OBJECTIVES: To assess the usefulness of clinical findings, nerve conduction studies and ultrasonography performed by a rheumatologist to predict success in patients with idiopathic carpal tunnel syndrome (CTS) undergoing median nerve release. METHODS: Ninety consecutive patients with CTS (112 wrists) completed a specific CTS questionnaire and underwent physical examination and nerve conduction studies. Ultrasound examination was performed by a rheumatologist who was blind to any patient's data. Outcome variables were improvement >25% in symptoms of the CTS questionnaire and patient's overall satisfaction (5-point Likert scale) at 3 months postoperatively. Success was defined as improvement in both outcome variables. Receiver operating characteristics (ROC) curves and logistic regression analyses were used to assess the best predictive combination of preoperative findings. RESULTS: Success was achieved in 63% of the operated wrists. Utility parameters and area under the ROC curve (AUC) for individual findings was poor, ranging from 0.481 of the nerve conduction study to 0.634 of the cross-sectional area at tunnel outlet. Logistic regression identified the preoperative US parameters as the best predictive variables for success after 3 months. The best predictive combination (AUC=0.708) included a negative Phalen maneuver, plus absence of thenar atrophy, plus less than moderately abnormalities on nerve conduction studies plus a large maximal cross-sectional area along the tunnel by ultrasonography. CONCLUSION: Although cross-sectional area of the median nerve was the only predictor of success after three months of surgical release, isolated preoperative findings are not reliable predictors of success in patients with idiopathic CTS. A combination of findings that include ultrasound improves prediction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] OBJECTIVE: To determine the value of ultrasonography in the assessment of patients with idiopathic carpal tunnel syndrome (CTS) and poor outcome after carpal tunnel release. METHODS: A total of 88 consecutive patients with CTS (104 hands) underwent open surgical release of the median nerve. Ultrasound (US) examination was performed blind to any patient's data. The median nerve area at tunnel inlet and outlet, the retinaculum distance, and the flattening ratio were measured. The main outcome variable was the patient's overall satisfaction using a five-point Likert scale (1 = worse, 2 = no change, 3 = slightly better, 4 = much better, 5 = cured) at 3 months postoperatively. Pre- and postoperative ultrasonographic findings in relation to clinical outcome were analysed. RESULTS: Improvement (scores 4 or 5 on the Likert scale) was recorded in 75 hands (72%). After carpal tunnel release, the cross-sectional area at tunnel inlet decreased from a mean of 14.2 to 13.3 mm2 in the group with clinical improvement and also from a mean of 12.5 to 11.6 mm2 in the group with no change or slight improvement. No significant changes in the cross-sectional area at tunnel outlet, retinaculum distance, and flattening ratio were observed. CONCLUSION: Reduction of the median nerve cross-sectional area at tunnel inlet at 3 months after carpal tunnel release was similar in patients reporting cure or great improvement and in those with slight or no improvement. Ultrasonography is of limited value in assessment of patients with poor outcome after median nerve release.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this dissertation is to develop and test a predictive model for the passive kinematics of human joints based on the energy minimization principle. To pursue this goal, the tibio-talar joint is chosen as a reference joint, for the reduced number of bones involved and its simplicity, if compared with other sinovial joints such as the knee or the wrist. Starting from the knowledge of the articular surface shapes, the spatial trajectory of passive motion is obtained as the envelop of joint configurations that maximize the surfaces congruence. An increase in joint congruence corresponds to an improved capability of distributing an applied load, allowing the joint to attain a better strength with less material. Thus, joint congruence maximization is a simple geometric way to capture the idea of joint energy minimization. The results obtained are validated against in vitro measured trajectories. Preliminary comparison provide strong support for the predictions of the theoretical model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nel presente lavoro sono esposti i comportamenti e le caratteristiche principali dei giunti incollati. Il metodo agli elementi finiti è stato studiato in modo da realizzare un modello accurato di un sistema fisico. L’analisi agli elementi finiti è stata utilizzata per effettuare una simulazione numerica di un single-strap joint in alluminio e in CFRP sotto un carico di trazione assiale. L’effetto di una modifica della distanza tra le lastre è stato studiato e i risultati confrontati.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esposizione di comportamenti e caratteristiche principali dei giunti incollati. Il metodo agli elementi finiti è stato studiato in modo da realizzare un modello accurato di un sistema fisico. L’analisi agli elementi finiti è stata utilizzata per effettuare una simulazione numerica di un double-strap joint in alluminio e in CFRP sotto un carico di trazione assiale. L’effetto di una modifica della distanza tra le lastre è stato studiato e i risultati confrontati.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present thesis was to investigate the influence of lower-limb joint models on musculoskeletal model predictions during gait. We started our analysis by using a baseline model, i.e., the state-of-the-art lower-limb model (spherical joint at the hip and hinge joints at the knee and ankle) created from MRI of a healthy subject in the Medical Technology Laboratory of the Rizzoli Orthopaedic Institute. We varied the models of knee and ankle joints, including: knee- and ankle joints with mean instantaneous axis of rotation, universal joint at the ankle, scaled-generic-derived planar knee, subject-specific planar knee model, subject-specific planar ankle model, spherical knee, spherical ankle. The joint model combinations corresponding to 10 musculoskeletal models were implemented into a typical inverse dynamics problem, including inverse kinematics, inverse dynamics, static optimization and joint reaction analysis algorithms solved using the OpenSim software to calculate joint angles, joint moments, muscle forces and activations, joint reaction forces during 5 walking trials. The predicted muscle activations were qualitatively compared to experimental EMG, to evaluate the accuracy of model predictions. Planar joint at the knee, universal joint at the ankle and spherical joints at the knee and at the ankle produced appreciable variations in model predictions during gait trials. The planar knee joint model reduced the discrepancy between the predicted activation of the Rectus Femoris and the EMG (with respect to the baseline model), and the reduced peak knee reaction force was considered more accurate. The use of the universal joint, with the introduction of the subtalar joint, worsened the muscle activation agreement with the EMG, and increased ankle and knee reaction forces were predicted. The spherical joints, in particular at the knee, worsened the muscle activation agreement with the EMG. A substantial increase of joint reaction forces at all joints was predicted despite of the good agreement in joint kinematics with those of the baseline model. The introduction of the universal joint had a negative effect on the model predictions. The cause of this discrepancy is likely to be found in the definition of the subtalar joint and thus, in the particular subject’s anthropometry, used to create the model and define the joint pose. We concluded that the implementation of complex joint models do not have marked effects on the joint reaction forces during gait. Computed results were similar in magnitude and in pattern to those reported in literature. Nonetheless, the introduction of planar joint model at the knee had positive effect upon the predictions, while the use of spherical joint at the knee and/or at the ankle is absolutely unadvisable, because it predicted unrealistic joint reaction forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gleno-humeral joint (GHJ) is the most mobile joint of the human body. This is related to theincongr uence between the large humeral head articulating with the much smaller glenoid (ratio 3:1). The GHJ laxity is the ability of the humeral head to be passively translated on the glenoid fossa and, when physiological, it guarantees the normal range of motion of the joint. Three-dimensional GHJ linear displacements have been measured, both in vivo and in vitro by means of different instrumental techniques. In vivo gleno-humeral displacements have been assessed by means of stereophotogrammetry, electromagnetic tracking sensors, and bio-imaging techniques. Both stereophotogrammetric systems and electromagnetic tracking devices, due to the deformation of the soft tissues surrounding the bones, are not capable to accurately assess small displacements, such as gleno-humeral joint translations. The bio-imaging techniques can ensure for an accurate joint kinematic (linear and angular displacement) description, but, due to the radiation exposure, most of these techniques, such as computer tomography or fluoroscopy, are invasive for patients. Among the bioimaging techniques, an alternative which could provide an acceptable level of accuracy and that is innocuous for patients is represented by magnetic resonance imaging (MRI). Unfortunately, only few studies have been conducted for three-dimensional analysis and very limited data is available in situations where preset loads are being applied. The general aim of this doctoral thesis is to develop a non-invasive methodology based on open-MRI for in-vivo evaluation of the gleno-humeral translation components in healthy subjects under the application of external loads.