970 resultados para biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the main reasons for the failure in dental implant treatments is the overload, which can cause bone resorption and later, the osseointegration loss in the implant. Therefore, the aim of this study was to analyze the tension generated around dental implants in the rehabilitation of three mandible posterior teeth, varying the connection type, the disposal, and the quantity of implants. The photoelasticity method was used in order to accomplish it. Through photoelasticity, the quantity and localization of the tensions around the implants in the different studied groups were compared (three straight line implants, three offset placement implants, two implants with a mesial cantilever, and two implants with a pontic). The results showed that the tension quantity and disposition around the dental implants of the connection external hexagon and internal hexagon were similar in all groups. In the group where the cantilever was used, an increase of the tension around the implant, adjacent to the cantilever, was observed. From the results it is concluded that the type of connection used in this study did not influence the tension quantity and distribution around the implants; however, the prosthetic configuration with the cantilever use, led to an increase of the tension around the implant, adjacent to the cantilever.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gait disorders are identified in people with Parkinson’s disease. The aim of this study was to investigate the effect of auditory cues and medication on kinematic, kinetic and EMG parameters, during different gait phases of people with PD and healthy elderly. Thirty subjects distributed in two groups (Group 1, PD patients off and on medication; Group 2, healthy elderly) participated in this study and were instructed to walk in two experimental conditions: non-cued and cued. Therefore, kinematic, kinetic and electromyography analyses were utilized to investigate the locomotor pattern. Changes in locomotor pattern (greater muscular activity) with auditory cue were observed for PD patients. Regarding the medication, locomotor parameter improvement was observed after levodopa intake in association with the auditory cue. These results confirm the hypothesis about the external cues therapy that could be used as a complement to drug therapy to achieve improvement in the locomotor pattern of PD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contemporary orthodontics has sought, beyond the esthetic, occlusal and functional goals, treatments even faster and with less visits to the orthodontist — especially in patients that require dental extractions in which the generated space becomes a nuisance. The segmented arch technic (SAT), by the use of a "T" loop spring, has provided such results within these requirements. Therefore, this study aimed to appraise and demonstrate the confection, activation and biomechanical control of "T" loop spring, in the group with high anchorage necessity (group A), for retraction of anterior teeth; as well as to present a case report, with high anterior retraction necessity, treated with "T" loop spring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When a T-loop is used in segmental mechanics, it is generally attached posteriorly to an auxiliary tube in the first molars and anteriorly to a crimpable cross tube or a Burstone canine bracket. This article illustrates the use of a crimpable tube with a 90-degree bend on the base wire to secure a T-loop in segmental retraction. Both of these approaches allow a T-loop to be reactivated in a simple manner without undesirable changes in the system of forces, which could happen if the T-loop is skewed posteriorly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. OBJECTIVE: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. LITERATURE REVIEW AND CONCLUSION: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. Objective: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. Literature review and conclusion: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the influence of different implant designs on the micromovements of immediately placed implants. CT-based finite element models comprising an upper central incisor socket and four commercially available internal connection implant designs (SIN SW®, 3i Certain®, Nobel ReplaceTM, and RN synOcta® ITI Standard) of comparable diameter and length were constructed. 50, 100 and 200N magnitude loads were applied over the implant. ANOVA at 95% level of significance was used to evaluate bone to implant relative displacement (micromovements). The implant design (68,80%) greatly influences the micromovement of immediately placed implants. However, the loading magnitude (68,80%) is the most important factor regarding the implant stability in this protocol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report shows the resolution of a case study whose aim was promote the aesthetic and functional rehabilitation of upper left hemi-arch over endosseous and needle implant prostheses. To improve the position of the needle implants, we performed the bucco-palatal bending of needles splinting them with composite resin; we removed the screwed implant prosthesis in the regions of the premolars (24 and 25) and molar (26). The mini-abutments of the last two implants were replaced, and in the first premolar and canine, we used cemented abutments due to implant angulation having planned soldering because of implant size and contact with one needle implant that could interfere with intimate contact bone/implant damaging biomechanics. Pick-up impressions were performed with an open tray, using a retractor cord in the needle implants and respective transfer copings. Therefore, models were related on semi-adjustable articulator after a face-bow recording and interocclusal indexes. After working cast fabrication and try-in of infra-structures, these were adjusted and related into the articulator again. Then, after ceramic build-up, adjustments, finishing, and torque, chemically-activated resin cement was applied on units 21 to 24. At the end of the case, we concluded that a good aesthetic and functional rehabilitation depends on thorough knowledge of techniques for each clinical situation.