950 resultados para authenticity label
Resumo:
Vitamin C degradation was evaluated in industrialized cashew juice of high pulp content and in cajuina by the method of Tillmans during eleven days of storage after the opening of the flask. For recently opened juices, vitamin C was found in the concentration range of 112 to 170 mg for 100 g of juice. The degradation of vitamin C in industrialized cashew juices changes when different additives are used. All of the cajuinas presented a vitamin C content below that specified on the label.
Resumo:
BACKGROUND: Little is known about the long-term changes in the functioning of schizophrenia patients receiving maintenance therapy with olanzapine long-acting injection (LAI), and whether observed changes differ from those seen with oral olanzapine. METHODS: This study describes changes in the levels of functioning among outpatients with schizophrenia treated with olanzapine-LAI compared with oral olanzapine over 2 years. This was a secondary analysis of data from a multicenter, randomized, open-label, 2-year study comparing the long-term treatment effectiveness of monthly olanzapine-LAI (405 mg/4 weeks; n=264) with daily oral olanzapine (10 mg/day; n=260). Levels of functioning were assessed with the Heinrichs-Carpenter Quality of Life Scale. Functional status was also classified as 'good', 'moderate', or 'poor', using a previous data-driven approach. Changes in functional levels were assessed with McNemar's test and comparisons between olanzapine-LAI and oral olanzapine employed the Student's t-test. RESULTS: Over the 2-year study, the patients treated with olanzapine-LAI improved their level of functioning (per Quality of Life total score) from 64.0-70.8 (P<0.001). Patients on oral olanzapine also increased their level of functioning from 62.1-70.1 (P<0.001). At baseline, 19.2% of the olanzapine-LAI-treated patients had a 'good' level of functioning, which increased to 27.5% (P<0.05). The figures for oral olanzapine were 14.2% and 24.5%, respectively (P<0.001). Results did not significantly differ between olanzapine-LAI and oral olanzapine. CONCLUSION: In this 2-year, open-label, randomized study of olanzapine-LAI, outpatients with schizophrenia maintained or improved their favorable baseline level of functioning over time. Results did not significantly differ between olanzapine-LAI and oral olanzapine.
Resumo:
Complex B vitamins are present in some cereal foods and the ingestion of enriched products contributes to the recommended dietary intake of these micronutrients. To adapt the label of some products, it is necessary to develop and validate the analytical methods. These methods must be reliable and with enough sensitivity to analyze complex B vitamins naturally present in food at low concentration. The purpose of this work is to evaluate, with validated methods, the content of vitamins B1, B2, B6 and niacin in five cereal flours used in food industry (oat, rice, barley, corn and wheat).
Resumo:
Fluent health information flow is critical for clinical decision-making. However, a considerable part of this information is free-form text and inabilities to utilize it create risks to patient safety and cost-effective hospital administration. Methods for automated processing of clinical text are emerging. The aim in this doctoral dissertation is to study machine learning and clinical text in order to support health information flow.First, by analyzing the content of authentic patient records, the aim is to specify clinical needs in order to guide the development of machine learning applications.The contributions are a model of the ideal information flow,a model of the problems and challenges in reality, and a road map for the technology development. Second, by developing applications for practical cases,the aim is to concretize ways to support health information flow. Altogether five machine learning applications for three practical cases are described: The first two applications are binary classification and regression related to the practical case of topic labeling and relevance ranking.The third and fourth application are supervised and unsupervised multi-class classification for the practical case of topic segmentation and labeling.These four applications are tested with Finnish intensive care patient records.The fifth application is multi-label classification for the practical task of diagnosis coding. It is tested with English radiology reports.The performance of all these applications is promising. Third, the aim is to study how the quality of machine learning applications can be reliably evaluated.The associations between performance evaluation measures and methods are addressed,and a new hold-out method is introduced.This method contributes not only to processing time but also to the evaluation diversity and quality. The main conclusion is that developing machine learning applications for text requires interdisciplinary, international collaboration. Practical cases are very different, and hence the development must begin from genuine user needs and domain expertise. The technological expertise must cover linguistics,machine learning, and information systems. Finally, the methods must be evaluated both statistically and through authentic user-feedback.
Resumo:
Eight trace elements were determined in 20 Brazilian brands of grape juice, distributed over the country. Highest measured concentrations (As: 0.016; Cd: 0.010; Cr: 0.060; Cu: 1.28; Ni: 0.032; Pb: 0.016; Sb: 0.0040 and Zn: 1.44 mg L-1) comply with Brazilian maximal tolerance levels for inorganic contaminants (As: 0.5; Cd: 0.5; Cr: 0.1; Cu: 30; Ni: 3; Pb: 0.4; Sb: 1 and Zn: 25 mg L-1). Determination of arsenic species has shown inorganic As(V) as predominant in most samples. Sodium concentrations, nowadays a major public health concern, were also measured, showing an average of 149 mg L-1. Analytical results for this element were much higher than label concentrations, showing the need for better quality control.
Resumo:
The increasing incidence of type 1 diabetes has led researchers on a quest to find the reason behind this phenomenon. The rate of increase is too great to be caused simply by changes in the genetic component, and many environmental factors are under investigation for their possible contribution. These studies require, however, the participation of those individuals most likely to develop the disease, and the approach chosen by many is to screen vast populations to find persons with increased genetic risk factors. The participating individuals are then followed for signs of disease development, and their exposure to suspected environmental factors is studied. The main purpose of this study was to find a suitable tool for easy and inexpensive screening of certain genetic risk markers for type 1 diabetes. The method should be applicable to using whole blood dried on sample collection cards as sample material, since the shipping and storage of samples in this format is preferred. However, the screening of vast sample libraries of extracted genomic DNA should also be possible, if such a need should arise, for example, when studying the effect of newly discovered genetic risk markers. The method developed in this study is based on homogeneous assay chemistry and an asymmetrical polymerase chain reaction (PCR). The generated singlestranded PCR product is probed by lanthanide-labelled, LNA (locked nucleic acid)-spiked, short oligonucleotides with exact complementary sequences. In the case of a perfect match, the probe is hybridised to the product. However, if even a single nucleotide difference occurs, the probe is bound instead of the PCR product to a complementary quencher-oligonucleotide labelled with a dabcyl-moiety, causing the signal of the lanthanide label to be quenched. The method was applied to the screening of the well-known type 1 diabetes risk alleles of the HLA-DQB1 gene. The method was shown to be suitable as an initial screening step including thousands of samples in the scheme used in the TEDDY (The Environmental Determinants of Diabetes in the Young) study to identify those individuals at increased genetic risk. The method was further developed into dry-reagent form to allow an even simpler approach to screening. The reagents needed in the assay were in dry format in the reaction vessel, and performing the assay required only the addition of the sample and, if necessary, water to rehydrate the reagents. This allows the assay to be successfully executed even by a person with minimal laboratory experience.
Resumo:
The present article provides an overview of the Globally Harmonised System of Classification, Labelling and Packaging of Chemicals (GHS) and its implementation in Brazil. Although Classification and Packaging is beyond the scope of the responsibility of academic chemists, labelling of chemicals used in academic laboratories will be required by the competent authorities to ensure the safety of students and staff. Therefore, academic teachers and researchers responsible should be familiarised with the GHS principles outlined here and at least be able to label, by applying these principles, mixtures of substances previously classified by the competent authorities.
Resumo:
Electron paramagnetic resonance (EPR) spectroscopy was used to study the main structural accommodations of spin labels in bilayers of saturated phosphatidylcholines with acyl chain lengths ranging from 16 to 22 carbon atoms. EPR spectra allowed the identification of two distinct spectral components in thermodynamic equilibrium at temperatures below and above the main phase transition. An accurate analysis of EPR spectra, using two fitting programs, enabled determination of the thermodynamic profile for these major probe accommodations. Focusing the analysis on two-component EPR spectra of a spin-labeled lipid, the influence of 40 mol % cholesterol in DPPC was studied.
Resumo:
In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R² > 0.999) over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.
Resumo:
This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.
Resumo:
Typically hundreds of different chemical products stored in small flasks which cannot accommodate labels large enough to bear all information required by the Globally Harmonised System of Classification, Labelling and Packaging of Chemicals (GHS) are used in academic laboratories. To overcome this restriction Brazilian legislation permits communication of the dangers of chemical products to trained laboratory workers/students by alternative means. Here we describe an alternative label system, developed by the German Social Accident Insurance (DGUV), which allows hazard communication to trained workers/students via a labelling system, using pictograms and highly condensed hazard statements to alert about dangerous chemical products.
Resumo:
This work shows the application of ¹H NMR spectroscopy and chemometrics for quality control of grape juice. A wide range of quality assurance parameters were assessed by single ¹H NMR experiments acquired directly from juice. The investigation revealed that conditions and time of storage should be revised and indicated on all labels. The sterilization process of homemade grape juices was efficient, making it possible to store them for long periods without additives. Furthermore, chemometric analysis classified the best commercial grape juices to be similar to homemade grape juices, indicating that this approach can be used to determine the authenticity after adulteration.
Resumo:
Three sensitive spectrophotometric methods are presented for the determination of finasteride in bulk and in tablets. The methods rely on the use of bromate-bromide reagent and three dyes namely, methyl orange, indigocarmine and thymol blue as reagents. They involve the addition of a measured excess of bromate-bromide reagent to finasteride in acid medium, and after the bromination reaction is judged to be complete, the unreacted bromine is determined by reacting with a fixed amount of either methylorange and measuring the absorbance at 520 nm (method A) or indigocarmine and measuring the absorbance at 610 nm (method B) or thymol blue and measuring the absorbance at 550 nm (method C). In all the methods, the amount of insitu generated bromine reacted corresponds to the amount of finasteride. The absorbance measured at the respective wavelength is found increase linearly with the concentration of finasteride. Beer's law is obeyed in the ranges 0.25- 2.0, 0.5-6.0 and 1-12 µg mL-1 for method A, method B and method C, respectively. The calculated molar absorptivity values are 5.7x10(4), 3.12x10(4) and 1.77x10(4) L mol-1 cm-1 respectively, for method A, method B and method C, and the corresponding Sandell sensitivity values are 0.0065, 0.012 and 0.021 µg cm-2. The limits of detection (LOD) and quantification (LOQ) are also reported for all the methods. Accuracy and, intra-day and inter-day precisions of the methods were established according to the current ICH guidelines. The methods were successfully applied to the determination of finasteride in commercially available tablets and the results were found to closely agree with the label claim. The results of the methods were statistically compared with those of a reference method by applying Student's t-test and F-test. The accuracy and reliability of the methods were further confirmed by performing recovery tests via standard addition procedure.
Resumo:
Two simple sensitive and cost-effective spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsules using ceric ammonium sulphate (CAS), iron (II), orthophenanthroline and thiocyanate as reagents. In both methods, an acidic solution of lansoprazole is treated with a measured excess of CAS followed by the determination of unreacted oxidant by two procedures involving different reaction schemes. The first method involves the reduction of residual oxidant by a known amount of iron(II), and the unreacted iron(II) is complexed with orthophenanthroline at a raised pH, and the absorbance of the resulting complex measured at 510 nm (method A). In the second method, the unreacted CAS is reduced by excess of iron (II), and the resulting iron (III) is complexed with thiocyanate in the acid medium and the absorbance of the complex measured at 470 nm (method B). In both methods, the amount CAS reacted corresponds to the amount of LPZ. In method A, the absorbance is found to increase linearly with the concentration of LPZ where as in method B a linear decrease in absorbance occurs. The systems obey Beer's law for 2.5-30 and 2.5-25 µg mL-1 for method A and method B, respectively, and the corresponding molar absorptivity values are 8.1×10³ and 1.5×10(4) L mol-1cm-1 . The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim. No interference was observed from the concomitant substances normally added to capsules.
Resumo:
Two sensitive spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsule formulation. The methods are based on the oxidation of lansoprazole by insitu generated bromine followed by determination of unreacted bromine by two different reaction schemes. In one procedure (method A), the residual bromine is treated with excess of iron (II), and the resulting iron (III) is complexed with thiocyanate and measured at 470 nm. The second approach (method B) involves treating the unreacted bromine with a measured excess of iron (II) and remaining iron (II) is complexed with orthophenanthroline at a raised pH, and measured at 510 nm. In both methods, the amount of bromine reacted corresponds to the amount of LPZ. The experimental conditions were optimized. In method A, the absorbance is found to decrease linearly with the concentration of LPZ (r = -0.9986) where as in the method B a linear increase in absorbance occurs (r = 0.9986) The systems obey Beer's law for 0.5-4.0 and 0.5-6.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 3.97µ10(4) and 3.07µ10(4) L mol-1cm-1 for method A and method B, respectively, and the corresponding Sandell sensitivity values are 0.0039 and 0.0013 µg cm-2. The limit of detection (LOD) and quantification (LOQ) are also reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim and the results were statistically compared with those of a reference method by applying the Student's t-test and F-test. No interference was observed from the concomitant substances normally added to capsules. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard-addition method.