969 resultados para assessment standards


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, Perfil de Gestão e Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microcirculatory resistance (IMR) is an invasive method for quantitatively assessing the coronary microcirculation status. OBJECTIVES: To examine heart microcirculation after intracoronary injection of mesenchymal stem/stromal cells with the index of microcirculatory resistance. METHODS: Healthy swine were randomized to receive by intracoronary route either 30x106 MSC or the same solution with no cells (1% human albumin/PBS) (placebo). Blinded operators took coronary pressure and flow measurements, prior to intracoronary infusion and at 5 and 30 minutes post-delivery. Coronary flow reserve (CFR) and the IMR were compared between groups. RESULTS: CFR and IMR were done with a variance within the 3 transit time measurements of 6% at rest and 11% at maximal hyperemia. After intracoronary infusion there were no significant differences in CFR. The IMR was significantly higher in MSC-injected animals (at 30 minutes, 14.2U vs. 8.8U, p = 0.02) and intragroup analysis showed a significant increase of 112% from baseline to 30 minutes after cell infusion, although no electrocardiographic changes or clinical deterioration were noted. CONCLUSION: Overall, this study provides definitive evidence of microcirculatory disruption upon intracoronary administration of mesenchymal stem/stromal cells, in a large animal model closely resembling human cardiac physiology, function and anatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT:C-reactive protein (CRP) has been widely used in the early risk assessment of patients with acute pancreatitis (AP), but unclear aspects about its prognostic accuracy in this setting persist. This project evaluated first CRP prognostic accuracy for severity, pancreatic necrosis (PNec), and in-hospital mortality (IM) in AP in terms of the best timing for CRP measurement and the optimal CRP cutoff points. Secondly it was evaluated the CRP measured at approximately 24 hours after hospital admission (CRP24) prognostic accuracy for IM in AP individually and in a combined model with a recent developed tool for the early risk assessment of patients with AP, the Bedside Index for Severity in AP (BISAP). Two single-centre retrospective cohort studies were held. The first study included 379 patients and the second study included 134 patients. Statistical methods such as the Hosmer-Lemeshow goodness-of-fit test, the area under the receiver-operating characteristic curve, the net reclassification improvement, and the integrated discrimination improvement were used. It was found that CRP measured at approximately 48 hours after hospital admission (CRP48) had a prognostic accuracy for severity, PNec, and IM in AP better than CRP measured at any other timing. It was observed that the optimal CRP48 cutoff points for severity, PNec, and IM in AP varied from 170mg/l to 190mg/l, values greater than the one most often recommended in the literature – 150mg/l. It was found that CRP24 had a good prognostic accuracy for IM in AP and that the cutoff point of 60mg/l had a negative predictive value of 100%. Finally it was observed that the prognostic accuracy of a combined model including BISAP and CRP24 for IM in AP could perform better than the BISAP alone model. These results might have a direct impact on the early risk assessment of patients with AP in the daily clinical practice.--------- RESUMO: A proteina c-reactiva (CRP) tem sido largamente usada na avaliação precoce do risco em doentes com pancreatite aguda (AP), mas aspectos duvidosos acerca do seu valor prognóstico neste contexto persistem. Este projecto avaliou primeiro o valor prognóstico da CRP para a gravidade, a necrose pancreática (PNec) e a mortalidade intra-hospitalar (IM) na AP em termos do melhor momento para efectuar a sua medição e dos seus pontos-de-corte óptimos. Em segundo lugar foi avaliado o valor prognóstico da proteína c-reactiva medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) para a IM na AP isoladamente e num modelo combinado, que incluiu uma ferramenta de avaliação precoce do risco em doentes com AP recentemente desenvolvida, o Bedside Index for Severity in Acute Pancreatitis (BISAP). Dois estudos unicêntricos de coorte retrospectivo foram realizados. O primeiro estudo incluiu 379 doentes e o segundo estudo incluiu 134 doentes. Metodologias estatísticas como o teste de Hosmer-Lemeshow goodness-of-fit, a area under the receiver-operating characteristic curve, o net reclassification improvement e o integrated discrimination improvement foram usadas. Verificou-se que a CRP medida às 48 horas após a admissão hospitalar (CRP48) teve um valor prognóstico para a gravidade, a PNec e a IM na AP melhor do que a CRP medida em qualquer outro momento. Observou-se que os pontos de corte óptimos da CRP48 para a gravidade, a PNec e a IM na AP variaram entre 170mg/l e 190mg/l, valores acima do valor mais frequentemente recomendado na literatura – 150mg/l. Verificou-se que a CRP medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) teve um bom valor prognóstico para a IM na AP e que o ponto de corte 60mg/l teve um valor preditivo negativo de 100%. Finalmente observou-se que o valor prognóstico de um modelo combinado incluindo o BISAP e a CRP24 para a IM na AP pode ter um desempenho melhor do que o do BISAP isoladamente. Estes resultados podem ter um impacto directo na avaliação precoce do risco em doentes com AP na prática clínica diária.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the presentation and discussion at the 3rd Winter School on Technology Assessment, December 2012, Universidade Nova de Lisboa (Portugal), Caparica Campus, PhD programme on Technology Assessment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cement & Concrete Composites 45 (2014) 264–271

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Materials Science Forum Vols. 730-732 (2013) pp 617-622

Relevância:

20.00% 20.00%

Publicador:

Resumo:

International Seminar in Conservation. A Tribute to Cesari Brandi. Lisboa, LNEC, May 2006, p.273-282

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Industrial