937 resultados para additive variance


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated in vitro the antibacterial activity of 4 root canal filling materials for primary teeth - zinc oxide and eugenol cement (ZOE), Calen paste thickened with zinc oxide (Calen/ZO), Sealapex sealer and EndoREZ sealer - against 5 bacterial strains commonly found in endodontic infections (Kocuria rhizophila, Enterococcus faecalis, Streptococcus mutans, Escherichia coli and Staphylococcus aureus) using the agar diffusion test (agar-well technique). Calen paste, 1% chlorhexidine digluconate (CHX) and distilled water served as controls. Seven wells per dish were made at equidistant points and immediately filled with the test and control materials. After incubation of the plates at 37oC for 24 h, the diameter of the zones of bacterial growth inhibition produced around the wells was measured (in mm) with a digital caliper under reflected light. Data were analyzed statistically by analysis of variance and Tukey's post-hoc test (?=0.05). There were statistically significant differences (p<0.0001) among the zones of bacterial growth inhibition produced by the different materials against all target microorganisms. K. rhizophila was inhibited more effectively (p<0.05) by ZOE, while Calen/ZO had its highest antibacterial activity against E. faecalis (p<0.05). S. mutans was inhibited by Calen/ZO, Sealapex and ZOE in the same intensity (p>0.05). E. coli was inhibited more effectively (p<0.05) by ZOE, followed by Calen/ZO and Sealapex. Calen/ZO and ZOE were equally effective (p>0.05) against S. aureus, while Sealapex had the lowest antibacterial efficacy (p<0.05) against this microorganism. EndoREZ presented antibacterial activity only against K. rhizophila and S. aureus. The Calen paste and Calen/ZO produced larger zones of inhibition than 1% CHX when the marker microorganism was E faecalis. In conclusion, the in vitro antibacterial activity of the 4 root canal filling materials for primary teeth against bacterial strains commonly found in endodontic infections can be presented in a decreasing order of efficacy as follows: ZOE>Calen/ZO>Sealapex>EndoREZ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 ± 1.42 µm and C = 2.77 ± 0.69 µm) and BC (M = 6.70 ± 1.37 µm and C = 4.48 ± 0.80 µm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 ± 0.91 µm and M = 1.78 ± 0.42 µm), followed by BL (C = 3.70 ± 1.32 µm and M = 3.70 ± 0.61 µm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 ± 1.42 µm), and results similar to the best ones against composite (2.77 ± 0.69 µm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full crowns was used. Custom trays were prepared with auto-polymerizing acrylic resin and impressions were performed with a dental surveyor, standardizing the path of insertion and removal of the tray. Alginate and elastomeric materials were used and stone casts were obtained after the impressions. For the silicones, impression techniques were also compared. To determine the impression materials' accuracy, digital photographs of the master model and of the stone casts were taken and the discrepancies between them were measured. The data were subjected to analysis of variance and Duncan's complementary test. Polyether and addition silicone following the single-phase technique were statistically different from alginate, condensation silicone and addition silicone following the double-mix technique (p < .05), presenting smaller discrepancies. However, condensation silicone was similar (p > .05) to alginate and addition silicone following the double-mix technique, but different from polysulfide. The results led to the conclusion that different impression materials and techniques influenced the stone casts' accuracy in a way that polyether, polysulfide and addition silicone following the single-phase technique were more accurate than the other materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The success of metal-ceramic restorations depends on an optimal bond between metal and ceramic. This study evaluated the effect of 3 casting atmospheres on the metal-ceramic bond strength (MCBS) of 2 Ni-Cr alloys, with beryllium (Fit Cast V) and without beryllium (Fit Cast SB). Sixty acrylic resin patterns (8 mm long and 5 mm diameter) were obtained using a fluorocarbon resin matrix. Wax was used to refine the surface of acrylic resin patterns that were invested and cast in an induction casting machine under normal, vacuum, and argon atmospheres at a temperature of 1340ºC. The castings were divested manually and airborne-particle abraded with 100-µm aluminum-oxide. Ten castings were obtained for each group. The IPS Classic V ceramic was applied (2 mm high and 5 mm diameter). The shear bond strength was tested in a mechanical testing machine with a crosshead speed of 2.0 mm/min. The MCBS data (MPa) were subjected to 2-way analysis of variance (α=0.05). There was no statistically significant difference (p>0.05) between the alloys or among the casting atmospheres. Within the limitations of this study, it may be concluded that the presence of beryllium and the casting atmosphere did not interfere in the MCBS of the evaluated metal-ceramic combinations

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated in vitro the capacity of debris removal from the apical third of flattened root canals, using different final irrigation protocols. Thirty human mandibular central incisors with a mesiodistal flattened root were prepared using rotary instrumentation by Endo-Flare 25.12 and Hero 642 30.06, 35.02, 40.02 files, irrigated with 2 mL of 1% NaOCl after each file. The specimens were randomly distributed into 5 groups according to the final irrigation of root canals: Group I: 10 mL of distilled water (control), Group II: 10 mL of 1% NaOCl for 8 min, Group III: 2 mL of 1% NaOCl for 2 min (repeated 4 times), Group IV: 10 mL of 2.5% NaOCl for 8 min, and Group V: 10 mL of 2.5% NaOCl for 2 min (repeated 4 times). The apical thirds of the specimens were subjected to histological processing and 6-μm cross-sections were obtained and stained with hematoxylin-eosin. The specimens were examined under optical microscopy at ×40 magnification and the images were subjected to morphometric analysis using the Scion image-analysis software. The total area of root canal and the area with debris were measured in square millimeters. Analysis of variance showed no statistically significant difference (p>0.05) among the groups GI (2.39 ± 3.59), GII (2.91 ± 2.21), GIII (0.73 ± 1.36), GIV (0.95 ± 0.84) and GV (0.51 ± 0.22). In conclusion, the final irrigation protocols evaluated in this study using the Luer syringe presented similar performance in the removal of debris from the apical third of flattened root canals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because a greater research effort has been directed to analyzing the adhesive effectiveness of self etch primers to dentin, the aim of this study was to evaluate, by microtensile testing, the bond strength to enamel of a composite resin combined with a conventional adhesive system or with a self-etching primer adhesive, used according to its original prescription or used with previous acid etching. Thirty bovine teeth were divided into 3 groups with 10 teeth each (n= 10). In one of the groups, a self-etching primer (Clearfil SE Bond - Kuraray) was applied in accordance with the manufacturer's instructions and, in the other, it was applied after previous acid etching. In the third group, a conventional adhesive system (Scotchbond Multipurpose Plus - 3M-ESPE) was applied in accordance with the manufacturer's instructions. The results obtained by analysis of variance revealed significant differences between the adhesive systems (F = 22.31). The self-etching primer (Clearfil SE Bond) presented lower enamel bond strength values than the conventional adhesive system (Scotchbond Multipurpose Plus) (m = 39.70 ± 7.07 MPa) both when used according to the original prescription (m = 27.81 ± 2.64 MPa) and with previous acid etching (m = 25.08 ± 4.92 MPa).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of acupuncture in minimizing the severity of radiation-induced xerostomia in patients with head and neck cancer. A total of 24 consecutive patients receiving > 5000 cGy radiotherapy (RT) involving the major salivary glands bilaterally were assigned to either the preventive acupuncture group (PA, n = 12), treated with acupuncture before and during RT, or the control group (CT, n = 12), treated with RT and not receiving acupuncture. After RT completion, clinical response was assessed in all patients by syalometry, measuring the resting (RSFR) and stimulated (SSFR) salivary flow rates, and by the visual analogue scale (VAS) regarding dry mouth-related symptoms. Statistical analyses were performed with repeated-measures using a mixed-effect modeling procedure and analysis of variance. An alpha level of 0.05 was accepted for statistical significance. Although all patients exhibited some degree of impairment in salivary gland functioning after RT, significant differences were found between the groups. Patients in the PA group showed improved salivary flow rates (RSFR, SSFR; p < 0.001) and decreased xerostomia-related symptoms (VAS, p < 0.05) compared with patients in the CT group. Although PA treatment did not prevent the oral sequelae of RT completely, it significantly minimized the severity of radiation-induced xerostomia. The results suggest that acupuncture focused in a preventive approach can be a useful therapy in the management of patients with head and neck cancer undergoing RT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4%, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of the use of 0.5% and 2% chlorhexidine digluconate on the immediate bond strength of a conventional adhesive system to dentin in primary teeth. METHODS: Twenty-one healthy primary molars were divided into three groups (n=7), being one control (A) and two experimental groups (B and C). After dentin exposure, in Group (A) the adhesive procedure was performed using 37% phosphoric acid gel (15 s); dentin was washed (15 s), air dried (30 s) and rehydrated with water. Groups B and C followed similar procedures but for re-hydration with 0.5% and 2% chlorhexidine, respectively, for 30 s. A resin composite block was built simulating a restoration, and the teeth were stored in distilled water at 37°C for 24 h before the microtensile bond strength test. The bond strength data were analyzed by analysis of variance. RESULTS: No statistically significant difference in bond strength was found among the tested groups (P>0.05) CONCLUSION: The 0.5% and 2% concentrations of chlorhexidine presented similar behavior and caused no adverse effects on the bond strength to dentin in primary teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the quality of filling in main and lateral root canals performed with the McSpadden technique, regarding the time spent on the procedure and the type of gutta-percha employed. Fifty simulated root canals, made with six lateral canals placed two apiece in the cervical, middle and apical thirds of the root, were divided into 5 groups. Group A: McSpadden technique with conventional gutta-percha, performed with sufficient time for canal filling; Group B: McSpadden technique with conventional gutta-percha, performed in twice the mean time used in Group A; Group C: McSpadden technique with TP gutta-percha, performed with sufficient time for canal filling; Group D: McSpadden technique with TP gutta-percha, performed in twice the mean time used in Group C; Group E: lateral condensation technique. Images of the filled root canals were taken using a stereomicroscope and analyzed using the Leica QWIN Pro software for filling material flow, gutta-percha filling extension and sealer flow. Data were analyzed by analysis of variance (ANOVA) and Tukey test (p < 0.05). The best values of penetration in lateral canals in the middle third occurred in the groups where TP gutta-percha was used. However, in the apical third, group B showed the best values. Although a longer time of compactor use allows greater penetration of the filling material into the lateral canals, the presence of voids resulted in bad quality radiographic images, suggesting porosity. The best quality of filling material was observed in Group A (McSpadden technique with conventional Gutta-Percha, performed with sufficient time for root canal filling).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dados de bovinos compostos foram analisados para avaliar o efeito da epistasia nos modelos de avaliação genética. As características analisadas foram os pesos aos 205 (P205) e 390 dias (P390) e perímetro escrotal aos 390 dias (PE390). As análises foram realizadas pela metodologia de máxima verossimilhança considerando-se dois modelos: o modelo 1 incluiu como covariáveis os efeitos aditivos diretos e maternos, e os não aditivos das heterozigoses para os efeitos diretos e para o materno total, e o modelo 2 considerou também o efeito direto de epistasia. Para comparação dos modelos, foram utilizados o critério de informação de Akaike (AIC) e o critério de informação Bayesiano de Schwartz (BIC), e o teste de razão de verossimilhança. A inclusão da epistasia no modelo de avaliação genética pouco alterou as estimativas de componentes de (co)variâncias genéticas aditivas e, consequentemente, as herdabilidades. O teste de verossimilhança e o critério de Akaike sugeriram que o modelo 2, que inclui a epistasia, apresentou maior aderência aos dados para todas as características analisadas. O critério BIC indicou este modelo como o melhor apenas para P205. Para análise genética dessa população, o modelo que considerou o efeito de epistasia foi o mais adequado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se neste trabalho estudar modelos com efeitos não-aditivos diretos e maternos em uma população composta em clima tropical, tentando minimizar esses efeitos para obtenção dos valores genéticos dos animais avaliados. Foram utilizados dados de animais de uma população composta, por meio da comparação de três modelos que incluíram os efeitos fixos de grupo contemporâneo, ordem de parto e heterose direta e materna e os efeitos aleatórios de efeito genético aditivo direto e materno. As análises foram realizadas em duas etapas; na primeira foram estudadas as estimativas dos efeitos raciais e de heterose individual e materna e na segunda etapa, calculadas as variâncias, herdabilidades e os valores genéticos dos animais. O efeito materno, quando não foi considerado no modelo, pareceu superestimar o efeito aditivo racial. Os efeitos aditivos raciais, racial materno e de heterose individual e materna influenciaram significativamente o ganho médio diário no pré-desmame, obtendo-se diferentes estimativas entre os tipos biológicos. Considerando o arquivo de dados corrigidos para os efeitos não-aditivos diretos e maternos, as herdabilidades direta e materna foram de 0,22 e 0,20, respectivamente. Os efeitos racial materno e de heterose individual e materna foram importantes fontes de variação para o ganho médio diário no pré-desmame e devem ser considerados durante a avaliação genética de uma população multirracial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar o efeito da administração da associação estavudina/nelfinavir durante toda a prenhez da rata, avaliando seu peso e dos conceptos, bem como o número de implantações, fetos, placentas, reabsorções e mortalidades materna e fetal. MÉTODOS: quarenta ratas albinas EPM-1 Wistar, prenhes, foram aleatoriamente divididas em quatro grupos: GCtrl (controle do veículo) e três experimentais, ExpI, ExpII e ExpIII, que receberam, respectivamente, 1/40, 3/120 e 9/360 mg/kg por dia de estavudina/nelfinavir por via oral. As drogas e o veículo (água destilada) foram administrados por gavagem em duas tomadas diárias (12/12 horas), desde o dia 0 até o 20º dia da prenhez. No último dia do experimento, todos os animais foram anestesiados e eutanasiados. Foram avaliados a evolução do peso materno no 7º, 14º e 20º dias, número de fetos, placentas, implantações, reabsorções, óbitos intrauterinos, malformações maiores e o peso dos fetos e das placentas. A análise estatística foi realizada por análise de variância (ANOVA), complementada pelo teste de Kruskal-Wallis (p<0,05). RESULTADOS: em relação ao peso corporal das ratas, houve ganho gradual e progressivo durante o decorrer da prenhez em todos os grupos, sendo este ganho mais evidente no período final; porém não foram constatadas diferenças estatisticamente significantes entre eles. O número de fetos, placentas, implantações, assim como os pesos fetais e placentários também não mostraram diferenças estatisticamente significantes entre os grupos analisados. Não foram observadas, também nos grupos experimentais, reabsorções e malformações fetais maiores externas, no entanto, observamos entre o 8º e o 14º dias de gestação um caso de morte materna em cada grupo experimental. CONCLUSÕES: a administração da associação estavudina/nelfinavir não mostrou efeitos deletérios sobre os conceptos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar os efeitos da administração da associação zidovudina-lamivudina-ritonavir nos fígados e rins de ratas prenhes e seus conceptos do ponto de vista morfológico e fisiológico. MÉTODOS: 40 ratas albinas prenhes foram aleatoriamente divididas em 4 grupos: 1 controle (Ctrl: controle de veículo) e 3 experimentais (Exp1x, Exp3x e Exp9x). Estes últimos foram tratados por solução oral de zidovudina/lamivudina/ritonavir (Exp1x: 10/5/20 mg/kg; Exp3x: 30/15/60 mg/kg; Exp9x: 90/45/180 mg/kg). As drogas e o veículo foram administrados por gavagem, desde o 1º até o 20º dia de prenhez. No último dia do experimento, todos os animais foram anestesiados e sangue foi retirado da cavidade cardíaca para avaliação sérica das enzimas aspartato aminotransferase (AST) e alanina aminotransferase (ALT), por método calorimétrico, bem como da ureia, determinada por método cinético-enzimático, e creatinina, por método cinético-colorimétrico. Em seguida, fragmentos dos fígados e rins maternos e fetais foram coletados, fixados em formol a 10% e processados segundo os métodos histológicos para inclusão em parafina. Cortes com 5 µm de espessura foram corados pela hematoxilina-eosina (HE) e analisados por microscopia de luz. Na leitura das lâminas, considerou-se o padrão de normalidade para fígado e rins, tais como: hepatócitos, espaço porta íntegros e veias hepáticas bem definidas. Nos rins, a presença de corpúsculos renais, túbulos contorcidos e alças de Henle típicos. Nos fígados fetais considerou-se, ainda, a morfologia das células da linhagem eritrocitária nas diferentes fases do desenvolvimento, bem como os megacariócitos. Quando houve alteração da coloração padrão estabelecida para as estruturas hepáticas e renais, alteração na morfologia de núcleos, rompimento de limites de alguma organela citoplasmática, presença de congestão vascular, tudo isso foi entendido como provavelmente provocado pelas drogas em sua(s) dose(s) de aplicação. A avaliação estatística foi realizada por análise de variância (ANOVA), completada pelo teste de Tukey-Kramer (p<0,05). RESULTADOS: os fígados maternos dos grupos Ctrl, Exp1x e Exp3x mostraram hepatócitos típicos, espaço porta íntegros e veias hepáticas com aspecto normal. No fígado materno do grupo Exp9x, foram encontrados hepatócitos com sinais de atrofia e apoptose (eosinofilia citoplasmática e núcleos picnóticos). Além disso, identificou-se vasodilatação dos capilares sinusoides (congestão). Os rins maternos dos grupos Ctrl e Exp1x apresentaram-se normais, com corpúsculos renais, túbulos contorcidos e alças de Henle típicos. Já nos grupos Exp3x e Exp9x, foram encontrados congestão vascular, glomérulos pequenos ricos em células contendo núcleos hipercromáticos, sendo mais intensos no Exp9x. Com relação aos fígados e rins fetais, não foram observadas alterações morfológicas ou fisiológicas nos grupos estudados. Encontrou-se aumento significante nos níveis da AST (305,70±55,80; p<0,05) e da creatinina (0,50±0,09; p<0,05) no grupo Exp9x. CONCLUSÕES: nossos resultados evidenciam que a administração da associação zidovudina/lamivudina/ritonavir a ratas prenhes em altas doses causa alterações morfológicas e funcionais nos fígados e rins maternos. Não houve alterações nem morfológicas nem fisiológicas nos fígados e rins fetais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este artigo discute um modelo de previsão combinada para a realização de prognósticos climáticos na escala sazonal. Nele, previsões pontuais de modelos estocásticos são agregadas para obter as melhores projeções no tempo. Utilizam-se modelos estocásticos autoregressivos integrados a médias móveis, de suavização exponencial e previsões por análise de correlações canônicas. O controle de qualidade das previsões é feito através da análise dos resíduos e da avaliação do percentual de redução da variância não-explicada da modelagem combinada em relação às previsões dos modelos individuais. Exemplos da aplicação desses conceitos em modelos desenvolvidos no Instituto Nacional de Meteorologia (INMET) mostram bons resultados e ilustram que as previsões do modelo combinado, superam na maior parte dos casos a de cada modelo componente, quando comparadas aos dados observados.