987 resultados para Valvular prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimTo evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions.Material and methodsForty SLActive Straumann (R) short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated.ResultsTwo out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2-year follow-up. The mean marginal bone loss before loading was 0.34 +/- 0.38 mm. After loading, the mean marginal bone loss was 0.23 +/- 0.33 and 0.21 +/- 0.39 mm at the 1- and 2-year follow-ups. The RFA values increased between insertion (70.2 +/- 9) and the 6-week evaluation (74.8 +/- 6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading.ConclusionShort implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns.To cite this article:Rossi F, Ricci E, Marchetti C, Lang NP, Botticelli D. Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study.Clin. Oral Impl. Res. 21, 2010; 937-943.doi: 10.1111/j.1600-0501.2010.01942.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors verified histologically in 20 no dentates patients, the influence of complete dentures on the hard palate mucosa. The patients were divided in two groups: I. Patients that never used complete dentures; II. Patients that were using complete dentures when this research was realized. New prosthesis were made for each one of the 20 patients. Immediately before they received the new prosthesis and ninety days after this, biopsies were realized. The circunferencial pieces of the hard palate mucosa were fixed in formol 10% and coloured with Hematoxylin/Eosin and Mallory's Tricomic for histomorphologic analysis and measuring of the stratum corneum of the epithelium. It was made the statistical analysis and the results showed that: 1. In normal conditions, the utilization of the full dentures produces the reduce of the thickness of the stratum corneum. This was more observed in Group I. 2. The range difference of the thickness of the stratum corneum between the first and the second biopsies in the groups I and II (4.86 microns and 2.18 microns) were not statistically significant. 3. With the use of complete dentures the stratum corneum of the epithelium showed tendence to parakeratinization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine the effect of heat and moisture exchange (HME) on the tracheobronchial tree (TBT) using a unidirectional anesthesic circuit with or without CO2 absorber and high or low fresh gas flow (FGF), in dogs. Methods: Thirty-two dogs were randomly allocated to four groups: G1 (n = 8) valvular circuit without CO2 absorber and high FGF (5 L·min-1); G2 (n = 8) as G1 with HME; G3 (n = 8) circuit with CO2 absorber with a low FGF (1 L·min-1); G4 (n = 8) as G3 with HME. Anesthesia was induced and maintained with pentobarbital. Tympanic temperature (TT), inhaled gas temperature (IGT), relative (RH) and absolute humidity (AH) of inhaled gas were measured at 15 (control), 60, 120 and 180 min of controlled ventilation. Dogs were euthanized and biopsies in the areas of TBT were performed by scanning electron microscopy. Results: The G2 and G4 groups showed the highest AH (>20 mgH2O·L-1) and G1 the lowest (< 10 mgH2O·L-1) and G3 was intermediate (<20 mgH2O·L-1) (P < 0.01). There was no difference of TT and IGT among groups. Alterations of the mucociliary system were greatest in G1, least in G2 and G4, and intermediate in G3. Conclusion: In dogs, introduction of HME to a unidirectional anesthetic circuit with/without CO2 absorber and high or low FGF preserved humidity of inspired gases. HME attenuated but did not prevent alterations of the mucociliary system of the TBT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study assessed the oral health of individuals 60 years or older in the city of Araraquara, Sao Paulo, Brazil, in 1998. Of the 194 people who participated in the study, 91 of them were institutionalized and had an average age of 73.6 years, and 103 were not institutionalized and had an average age of 69.3 years. The study participants were examined by a previously trained oral surgeon who determined the prevalence of the most common oral health problems. The results revealed a large number of edentulous individuals (72% of those institutionalized and 60% of the noninstitutionalized participants) and many persons with extracted teeth (93% and 90%, respectively), as well as a high frequency of periodontal pockets (57% and 75%, respectively) and of inadequate dentures (80% and 61%, respectively). Our results show reduced quality of life for a large proportion of these older individuals, and also indicate that public health services should pay greater attention to this population group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Utilization of contemporary post and core systems has facilitated the aesthetic restoration of endodontically treated teeth. Light transmission and biocompatibility have been enhanced by the introduction of metal-free post systems. The periodontal and endodontic status, root length, and histological structure of the devitalized teeth must be considered in order to achieve successful restoration following endodontic treatment. This article presents various restorative criteria for the aesthetic placement and buildup of post and core materials, as well as the preservation of maximum coronal and root structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This investigation studied the effects of 3 surface treatments on the shear bond strength of a light-activated composite resin bonded to acrylic resin denture teeth. Materials and Methods: The occlusal surfaces of 30 acrylic resin denture teeth were ground flat with up to 400-grit silicon carbide paper. Three different surface treatments were evaluated: (1) the flat ground surfaces were primed with methyl methacrylate (MMA) monomer for 180 seconds; (2) light-cured adhesive resin was applied and light polymerized according to the manufacturer's instructions; and (3) treatment 1 followed by treatment 2. The composite resin was packed on the prepared surfaces using a split mold. The interface between tooth and composite was loaded at a cross-head speed of 0.5 mm/min until failure. Results: Analysis of variance indicated significant differences between the surface treatments. Results of mean comparisons using Tukey's test showed that significantly higher shear bond strengths were developed by bonding composite resin to the surfaces that were previously treated with MMA and then with the bonding agent when compared to the other treatments. Conclusion: Combined surface treatment of MMA monomer followed by application of light-cured adhesive resin provided the highest shear bond strength between composite resin and acrylic resin denture teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors studied the behavior of calcium phosphate materials used as inlay implants into bone cavities prepared in the zygomatic arch of rats. Fifty male albino rats were divided into four groups as follows: group I-preparation of bone cavities which did not receive any implant material as controls; group II-implants of Interpore 200; group III-implants of experimental hydroxylapatite; group IV-implants of experimental hydroxylapatite combined with collagen. The animals were sacrificed after 5, 15, 30, 60 and 120 days and the specimens were submitted to histological analysis. Results showed that the experimental hydroxylapatite used in group III presented better osteogenic properties compared to the other materials. All tested materials were biocompatible, although group IV presented a more intense inflammatory response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the influence of ultrasound during the removal of posts cemented with either zinc phosphate cement, glass ionomer cement or resin cement. Methodology: Eighty-four single-rooted teeth were prepared and after cementation of cast posts, they were randomly divided into six groups of 14. Groups 1, 2 and 3 did not receive ultrasonic vibration, whilst groups 4, 5 and 6 received ultrasonic vibration for 10 min. The force necessary for post removal was determined using a universal testing machine. Results were statistically analysed using ANOVA and Tukey tests (5%). Results: The application of ultrasonic vibration reduced the retention provided by zinc phosphate and glass ionomer cements by 39% and 33%, respectively. Conclusions: A statistically significant reduction in the force necessary to remove posts cemented with zinc phosphate and glass ionomer cements occurred following application of ultrasound. The application of ultrasonic vibration did not influence the retention of cast posts cemented with resin cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this investigation was to evaluate the osteoinductive property of autogenous demineralized dentin matrix (ADDM) on experimental surgical bone defects in the parietal bone of rabbits using the guided bone regeneration (GBR) technique incorporating human amniotic membrane (HAM). Thirty-six rabbits were divided into 2 groups, HAM and ADDM+HAM. It was possible to conclude that HAM did not interfere with bone repair and was resorbed. Slices of ADDM induced direct bone formation and were incorporated by the newly formed bone tissue and remodeled. The bone defects healed faster in the ADDM+HAM group than in the group with HAM only.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Gelatinous polyethylene (GP) has been used as an orbital implant to evaluate volume maintenance and tissue reaction in the anophthalmic socket in a rabbit model. METHODS: Twenty-eight Norfolk white rabbits underwent unilateral evisceration with placement of 2ml GP (GP group - 16 animals) or 2ml 0.9% sodium chloride solution (Control group - 12 animals). Animal behavior, postoperative tissue response and socket conditions were evaluated. The animals were sacrificed at 7, 15, 30 and 60 days after the surgery and the bulbs were enucleated; volume maintenance and histopathological evaluation were done in the enucleated bulbs. The results were submitted to statistical analysis. RESULTS: All animals showed normal behavior. The orbital volume maintenance was better in the GP group. Histopathology in the GP animals showed mild tissue inflammation throughout the evaluation period and a thin pseudocapsule formation surrounding the orbital implant material. CONCLUSION: The clinical findings, good orbital volume maintenance and mild inflammatory tissue response make GP a good choice to replace the lack of volume in anophthalmic socket reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The utilization of dentifrices with low fluorine concentration, for children under 6 years of age, has been suggested to reduce the risks of dental fluorosis. However, in order to have anticariogenic potential, the dentifrice should form loosely-bound fluorine (CaF2) on dental enamel. Considering that the formation of CaF2 is a function inversely related to pH, dentifrices with pH 5.5, with 275, 550 and 1,100 ppm F (NaF/silica) were developed in order to assess dose-response effects. A comparison between those dentifrices, a placebo product and the Crest toothpaste (positive control - standard) was carried out. Furthermore, the bioavailability of dentifrices, in terms of formation of total fluorine (TF), CaF2, and fluorapatite (FA) on human dental enamel, was evaluated. An ion-specific electrode was utilized for the determination of the dosage of fluorine. The results revealed that the dentifrice with 550 ppm F was more effective than both the placebo and the dentifrice with 275 ppm, presenting no difference in relation to the positive control (p > 0.05). A dose-effect correlation was observed as to the CaF2 formed. In conclusion, the modified formulation with 550 ppm F can be considered as effective as the standard dentifrice with 1,100 ppm, and its utilization would be safer with regard to dental fluorosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The goal of this study was to evaluate microbiota and radiographic peri-implant bone loss associated with ligature-induced peri-implantitis. Materials and Methods: Thirty-six dental implants with 4 different surfaces (9 commercially pure titanium, 9 titanium plasma-sprayed, 9 hydroxyapatite, and 9 acid-etched) were placed in the edentulous mandibles of 6 dogs. After 3 months with optimal plaque control, abutment connection was performed. On days 0, 20, 40, and 60 after placement of cotton ligatures, both microbiologic samples and periapical radiographs were obtained. The presence of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia/nigrescens, Campylobacter spp, Capnocytophaga spp, Fusobacterium spp, beta-hemolytic Streptococcus, and Candida spp were evaluated culturally. Results: P intermedia/nigrescens was detected in 13.89% of implants at baseline and 100% of implants at other periods. P gingivalis was not detected at baseline, but after 20 and 40 days it was detected in 33.34% of implants and at 60 days it was detected in 29.03% of dental implants. Fusobacterium spp was detected in all periods. Streptococci were detected in 16.67% of implants at baseline and in 83.34%, 72.22%, and 77.42% of implants at 20, 40, and 60 days, respectively. Campylobacter spp and Candida spp were detected in low proportions. The total viable count analysis showed no significant differences among surfaces (P = .831), although a significant difference was observed after ligature placement (P < .0014). However, there was no significant qualitative difference, in spite of the difference among the periods. The peri-implant bone loss was not significantly different between all the dental implant surfaces (P = .908). Discussion and Conclusions: These data suggest that with ligature-induced peri-implantitis, both time and periodontal pathogens affect all surfaces equally after 60 days.