827 resultados para THERMAL NEUTRONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the influence of hydraulics and control of thermal storage in systems combined with solar thermal and heat pump for the production of warm water and space heating in dwellings. A reference air source heat pump system with flat plate collectors connected to a combistore was defined and modeled together with the IEA SHC Task 44 / HPP Annex 38 (T44A38) “Solar and Heat Pump Systems” boundary conditions of Strasbourg climate and SFH45 building. Three and four pipe connections as well as use of internal and external heat exchangers for DHW preparation were investigated as well as sensor height for charging of the DHW zone in the store. The temperature in this zone was varied to ensure the same DHW comfort was achieved in all cases. The results show that the four pipe connection results in 9% improvement in SPF compared to three pipe and that the external heat exchanger for DHW preparation leads to a 2% improvement compared to the reference case. Additionally the sensor height for charging the DHW zone of the store should not be too low, otherwise system performance is adversely affected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have shown that the optical properties of building exterior surfaces are important in terms of energy use and thermal comfort. While the majority of the studies are related to exterior surfaces, the radiation properties of interior surfaces are less thoroughly investigated. Development in the coil-coating industries has now made it possible to allocate different optical properties for both exterior and interior surfaces of steel-clad buildings. The aim of this thesis is to investigate the influence of surface radiation properties with the focus on the thermal emittance of the interior surfaces, the modeling approaches and their consequences in the context of the building energy performance and indoor thermal environment. The study consists of both numerical and experimental investigations. The experimental investigations include parallel field measurements on three similar test cabins with different interior and exterior surface radiation properties in Borlänge, Sweden, and two ice rink arenas with normal and low emissive ceiling in Luleå, Sweden. The numerical methods include comparative simulations by the use of dynamic heat flux models, Building Energy Simulation (BES), Computational Fluid Dynamics (CFD) and a coupled model for BES and CFD. Several parametric studies and thermal performance analyses were carried out in combination with the different numerical methods. The parallel field measurements on the test cabins include the air, surface and radiation temperatures and energy use during passive and active (heating and cooling) measurements. Both measurement and comparative simulation results indicate an improvement in the indoor thermal environment when the interior surfaces have low emittance. In the ice rink arenas, surface and radiation temperature measurements indicate a considerable reduction in the ceiling-to-ice radiation by the use of low emittance surfaces, in agreement with a ceiling-toice radiation model using schematic dynamic heat flux calculations. The measurements in the test cabins indicate that the use of low emittance surfaces can increase the vertical indoor air temperature gradients depending on the time of day and outdoor conditions. This is in agreement with the transient CFD simulations having the boundary condition assigned on the exterior surfaces. The sensitivity analyses have been performed under different outdoor conditions and surface thermal radiation properties. The spatially resolved simulations indicate an increase in the air and surface temperature gradients by the use of low emittance coatings. This can allow for lower air temperature at the occupied zone during the summer. The combined effect of interior and exterior reflective coatings in terms of energy use has been investigated by the use of building energy simulation for different climates and internal heat loads. The results indicate possible energy savings by the smart choice of optical properties on interior and exterior surfaces of the building. Overall, it is concluded that the interior reflective coatings can contribute to building energy savings and improvement of the indoor thermal environment. This can be numerically investigated by the choice of appropriate models with respect to the level of detail and computational load. This thesis includes comparative simulations at different levels of detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o efeito do choque térmico e mecânico na produtividade de Lentinula edodes em 140 toras de Eucalyptus saligna, completamente colonizadas pelo fungo, em diferentes tempos de imersão em água e no primeiro fluxo de produção. As toras foram imersas em água resfriada (16ºC) ou à temperatura ambiente (22ºC); os períodos de imersão corresponderam a 6, 10, 14, 18, 22, 26 e 38 horas; o choque mecânico foi acompanhado por três quedas consecutivas da tora, em posição vertical, no chão. A temperatura da água e o tempo de imersão afetaram a produção de L. edodes, resultando em aumentos significativos (2 a 4 vezes) nos tratamentos em que as toras foram submetidas à água resfriada e nos tempos de imersão mais curtos (6 e 10 horas). O choque mecânico não resultou em aumento na produção de basidiomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dentre os materiais de construção utilizados nas instalações rurais, merecem destaque as coberturas, pois são grandes responsáveis pelo conforto térmico, influenciando no balanço térmico no interior das instalações. Este trabalho objetivou avaliar a influência das coberturas sobre a entalpia (H), Carga Térmica Radiante (CTR) e no Índice de Temperatura de Globo Negro e Umidade (ITGU), em abrigos individuais para bezerros leiteiros. O delineamento foi o inteiramente casualizado com três tratamentos: Z - telha de zinco; CA - telha de cimento amianto, e CAB - telha de cimento amianto pintada de branco na face superior. As médias foram comparadas pelo teste de Scott Knott, a 1% de probabilidade. Os resultados mostraram que não houve diferença estatística entre os tratamentos (P<0,01) e o ambiente externo, para a H. Para a CTR, houve diferença estatística entre todos os tratamentos, em que CAB demonstrou menor CTR, 489,28 W m-², seguido do tratamento CA, 506,72 W m-², e Z com maior valor de CTR, 523,55 W m-². Para o ITGU, observaram-se menores valores para CAB (76,8) e CA (77,4), diferindo-se, significativamente do Z, que obteve maior valor (81,6). As telhas com pintura branca em sua face superior promoveram menor CTR e menor ITGU, favorecendo o ambiente térmico da instalação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho teve como objetivo estudar a biologia de Telenomus remus Nixon criado em ovos de Spodoptera frugiperda (J.E. Smith) em diferentes temperaturas. Com base no desenvolvimento do ciclo (ovo-adulto), foram determinados as exigências térmicas e o número de gerações dos parasitóides em temperaturas constantes. Inicialmente, ovos de S. frugiperda, com 24 horas de idade, foram submetidos ao parasitismo por T. remus, durante cinco horas, sendo então transferidos para câmaras climatizadas reguladas para as temperaturas de 15, 20, 25, 28, 31 e 35°C. A duração do ciclo (ovo-adulto) foi influenciada pela temperatura variando de 8,3±0,01 a 47,2±0,01 dias para fêmeas e 8,1±0,01 a 46,8±0,01 dias para machos de T. remus nas temperaturas de 31 e 15°C, respectivamente. A porcentagem de emergência (viabilidade) de T. remus em ovos de S. frugiperda também foi influenciada pela variação da temperatura, apresentando redução significativa apenas nas temperaturas extremas. Foi observada redução na viabilidade a 15°C e não houve desenvolvimento biológico do parasitóide a 35°C. A razão sexual de T. remus não sofreu influência da temperatura. em relação às exigências térmicas, a constante térmica (K) e temperatura base (Tb) foram maiores para as fêmeas de T. remus (158,88 graus dias e 12,52°C) quando comparadas aos machos (154,12 graus dias e 12,59°C). A estimativa do número de gerações anuais para T. remus para machos e fêmeas em condições de laboratório foi respectivamente 5,6 e 5,6; 16,9 e 17,3; 28,3 e 29,0; 35,1 e 36,0; 39,6 e 40,7 nas temperaturas de 15, 20, 25, 28 e 31°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. The relationship between repeated thermal treatments and hepatic synthesis of Hsp 70 was studied in broiler chickens.2. Sixty broilers were submitted to 5 different treatments (12 birds each) from day 1 to day 42. Four groups were kept in a thermoneutral environment and subjected to 0, 1, 2 and 3 heat stress episodes at 35 degrees C for 4 h per week (TN-0, TN-1, TN-2 and TN-3, respectively). The last group (HT-35) was reared at a room temperature of 35 degrees C.3. From 39 to 42 old, the birds experienced acute heat stress at 41 degrees C. Resistance to heat stress was evaluated by the time taken for rectal temperature to increase by 3 degrees C above the pre-treatment value. Livers were collected (before and after heat stress) and Hsp70 was determined using Western Blot analysis with monoclonal anti-Hsp70 antibody.4. Resistance to heat stress and concentration of Hsp70 were higher in those birds subjected to more heat stress episodes during the experimental period (TN-3) and HT-35. A positive correlation was observed between Hsp70 concentration and the time taken for a 3 degrees C increase in rectal temperature (r=0.42; P<0.01).5. Exposing birds to episodes of heat stress (35 degrees C) during rearing may improve their resistance to acute heat stress, but the previous thermal history did not seem to influence the hepatocyte Hsp70 content after exposure to more severe heat stress (41 degrees C).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combinations of temperature and time which can cause chilling injuries in avocados 'Geada', 'Quintal' and 'Fortuna' were determined. The binomial 4 degrees C/ 28 days was selected to determine the activity of peroxidase (POD), polyphenoloxidase (PPO), polygalacturonase (PG) and methylesterase pectin (PME). The respiratory activity was also evaluated. The fruits were stored at this condition until being transferred to ambient conditions (22 degrees C and 77% RH) until maturity, when they were compared to fruits stored permanently at this environment, after being cleaned (control). In the second part of this work, different hydrothermal treatments were tested to prevent or minimize chilling injuries. Avocados 'Geada', 'Quintal' and 'Fortuna' were treated at 38 degrees C for 0, 30, 60 and 90 minutes before storage at 4 degrees C for 28 days. It was observed that the activity of enzymes associated to browning, POD and PPO, and to maturation, PG and PME, had become greater in fruits stored at 4 degrees C, or when they were transferred to environmental conditions. Fruits subjected to refrigeration, after transferred to environment, presented lower respiratory peak intensity and it occurred earlier than the others. Treatments using 38 degrees C for 60 and 90 min minimized the symptoms of chilling injury in avocados 'Geada' while for 'Quintal' the most efficient was 38 degrees C for 60 min. In 'Fortuna' these treatments did not minimize the damage by cold.