997 resultados para Strain gradient


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The threshold body voltage (voltage gradient between head and tail) required for first reaction, electro-taxis and electro-narcosis depended upon species, conductivity of the fish body, nature of current and wave shape. Larger fishes showed first reaction at a lower body voltage than smaller ones. All the three reactions were dependent on the accommodation of nerves to the electrical field and subsequent fatigue of the fishes. No significant change was observed in the period of narcosis and recovery after repeated stimulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative study on growth of fry in nursery system of Genetically Improved Farmed Tilapia (GIFT) and Existing strain of Nile tilapia (Oreochromis niloticus) was performed. The trials were conducted in a series of hapa for two months. The initial mean weight of GIFT and Existing strains of tilapia were 1.03 and 1.12g, respectively and the stocking density for both the strains was maintained at 150/m³. Fishes were fed with supplementary feed 31.29% of protein level. After two months the final cumulative mean weight of GIFT and Existing strain were observed to be 8.38 and 5.51g, respectively. The net gain for weight of GIFT and existing strain were estimated to be 666% and 368% and the mean survival were 95.75% and 81.25%, respectively. The GIFT strain showed significantly (P<0.05) higher net gain in growth in weight and also higher (P<0.01) survival than that of existing strain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in the texture (elastic nature) of the flesh of barrel salted herring during the ripening process at 4°C have been monitored. The method employs the analysis of stress-relaxation curves after compression to half of the sample thickness on an lnstron Model 1112. The parameter 'T/P' for each sample represents the reciprocal of the gradient of a line connecting P and T0.368p. This parameter characteristic of each sample's texture was calculated as the ratio of 'T/P' where, T is the relaxation time and is defined as the time required for a stress at constant strain to decrease to 1/e of its original value, where 'e' is the base of natural logarithms (2.7183). Since 1/e=0.368, the relaxation time is the time required for the force to decay to 36.8% of its original value. P is the peak height of the curve (i.e. the force value at the maximum height). This method was adopted from the bakery industry for testing the degree of gluten development in bread dough. The 'T/P' values obtained over the course of ripening for differently treated salted-herring in barrels ranged between 1 and 12. The trends in 'T/P' value, during ripening period for the different samples, appeared to be parallel changes in texture perceived by sensory observation (subjective measurement), although the heterogeneous nature of the samples gave standard deviations, about the replicate sample mean, around 5%. The method appears promising as an objective measure for monitoring this aspect of the textural quality of barrel salted-herring through ripening if reproducibility of test results can be improved by more careful standardization of sample preparation and test protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is described for measuring the mechanical properties of polymers in compression at strain rates in the range approximately 300-500 s-1. A gravity-driven pendulum is used to load a specimen on the end of an instrumented Hopkinson output bar and the results are processed by a microcomputer. Stress-strain curves up to high strains are presented for polycarbonate, polyethersulphone and high density polyethylene over a range of temperatures. The value of yield stress, for all three polymers, was found to vary linearly with log (strain rate) at strain rates up to 500 s-1. © 1985.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical fiber strain sensing technique, based on Brillouin Optical Time Domain Reflectometry (BOTDR), was used to obtain the full deformation profile of a secant pile wall during construction of an adjacent basement in London. Details of the installation of sensors as well as data processing are described. By installing optical fiber down opposite sides of the pile, the distributed strain profiles obtained can be used to give both the axial and lateral movements along the pile. Measurements obtained from the BOTDR were found in good agreement with inclinometer data from the adjacent piles. The relative merits of the two different techniques are discussed. © 2007 ASCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes the use of optical fiber Brillouin Optical Time Domain Reflectometry (BOTDR) to monitor the strain distribution in an existing tunnel while a twin tunnel was bored at close-proximity. The twin circular bored tunnels between Serangoon and Bartley stations on the new Circle Line Stage 3 subway in Singapore were constructed at close-proximity to avoid underpinning the foundations of adjacent buildings. The minimum clear separation of the two tunnels is 2.3m (0.4 times the tunnel diameter). The Outer Tunnel was constructed first, followed by the Inner Tunnel, with the earth-pressure balance tunnel boring machines maintained at a minimum of 100m apart. In this trial application of BOTDR, the strain distribution along the Outer Tunnel was measured, in order to monitor its deformation due to the boring of the Inner Tunnel at close-proximity. The aim of the trial application was to determine the practicality of this monitoring method for future use in 'live' tunnels. This paper compares the measurements obtained from optical fiber BOTDR with conventional methods of tunnel monitoring and describes preliminary installation and workmanship guidelines derived from lessons learnt during this trial. © 2007 ASCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A packaging technique suited to applying MEMS strain sensors realized on a silicon chip to a steel flat surface is described. The method is based on adhesive bonding of the silicon chip rear surface on steel using two types of glue normally used for standard piezoresistive strain sensors (Mbond200/ 600), using direct wire bonding of the chip to a Printed Circuit Board, also fixed on steel. In order to protect the sensor from the external environment, and to improve the MEMS performance, the silicon chip is encapsulated with a metal cap hermetically sealed-off under vacuum condition with a vacuum adhesive in which the bonding wires are also protected from possible damage. In order to evaluate the mechanical coupling of the silicon chip with the bar and thestress transfer extent to the silicon surface, commercial strain sensors have been applied on the chip glued on a steel bar in alaboratory setup able to generate strain by inflection, yielding a stress transfer around 70% from steel to silicon. © 2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a gradient-based motion capture system that robustly tracks a human hand, based on abstracted visual information - silhouettes. Despite the ambiguity in the visual data and despite the vulnerability of gradient-based methods in the face of such ambiguity, we minimise problems related to misfit by using a model of the hand's physiology, which is entirely non-visual, subject-invariant, and assumed to be known a priori. By modelling seven distinct aspects of the hand's physiology we derive prior densities which are incorporated into the tracking system within a Bayesian framework. We demonstrate how the posterior is formed, and how our formulation leads to the extraction of the maximum a posteriori estimate using a gradient-based search. Our results demonstrate an enormous improvement in tracking precision and reliability, while also achieving near real-time performance. © 2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study on the breeding biology of the GIFT strain of Nile tilapia, Oreochromis niloticus, was conducted for a period of five months. The sex ratio of the parent individuals was optimized for performance in spawn production, where the best results were obtained with a sex ratio of female to male of 4:1 compared to those of 3:1 and 2:1. The diameter of eggs obtained from the GIFT stock had major and minor axes of 2.19±0.09 and 1.72±0.07 mm, respectively, with no significant differences between the treatments. The average number of eggs produced was 392±22 per female, with fertilization and hatching rates ranging between 94-96% and 85-88%, respectively. No significant variation was observed between the treatments. Breeding frequencies per female in the three treatment groups ranged between 10-40 days and the highest value was obtained at a female to male sex ratio of 4: l. In an other experiment, l7 aMethyltestosterone (MT) was applied orally to the fry at their first feeding stage with treatments- 1, 2, 3 and 4 at the dosage of 100, 80, 60 and 40 mg/kg feed respectively, for the period of 28 days. The mean percentage of males obtained in treatments, 1, 2, 3 and 4 were 98, 97, 95 and 68, respectively. Treatments-1, 2 and 3 did not differ significantly (P>0.05) from each other but treatment 4 showed significant variation (P<0.05) from other treatments. The results showed that MT-100, 80 and 60 mg/kg feed administered for 28 days produced close to cent percent male population of the GIFT strains in aquaria.