928 resultados para Solar thermal Solar combisystems Building integration Polymer materials
Resumo:
Due to communication and technology developments, residential consumers are enabled to participate in Demand Response Programs (DRPs), control their consumption and decrease their cost by using Household Energy Management (HEM) systems. On the other hand, capability of energy storage systems to improve the energy efficiency causes that employing Phase Change Materials (PCM) as thermal storage systems to be widely addressed in the building applications. In this paper, an operational model of HEM system considering the incorporation of more than one type of PCM in plastering mortars (hybrid PCM) is proposed not only to minimize the customerâ s cost in different DRPs but also to guaranty the habitantsâ  satisfaction. Moreover, the proposed model ensures the technical and economic limits of batteries and electrical appliances. Different case studies indicate that implementation of hybrid PCM in the buildings can meaningfully affect the operational pattern of HEM systems in different DRPs. The results reveal that the customerâ s electricity cost can be reduced up to 48% by utilizing the proposed model.
Resumo:
Nowadays, considering the high variety of construction products, adequate material selection, based on their properties and function, becomes increasingly important. In this research, a ranking procedure developed by Czarnecki and Lukowski is applied in mortars with incorporation of phase change materials (PCM). The ranking procedure transforms experimental results of properties into one numerical value. The products can be classified according to their individual properties or even an optimized combination of different properties. The main purpose of this study was the ranking of mortars with incorporation of different contents of PCM based in different binders. Aerial lime, hydraulic lime, gypsum and cement were the binders studied. For each binder, three different mortars were developed. Reference mortars, mortars with incorporation of 40% of PCM and mortars with incorporation of 40% of PCM and 1% of fibers, were tested. Results show that the incorporation of PCM in mortars changes their global performance.
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Tese de Doutoramento em Engenharia de Materiais.
Resumo:
Dissertação de International Master in Sustainable Built Environment
Resumo:
Dissertação de mestrado Internacional em Sustentabilidade do Ambiente Construído
Resumo:
Tese de Doutoramento em Engenharia Civil.
Resumo:
Energy management is the process of monitoring, controlling and conserving energy in a building or organisation. The main reasons for this are for cost purposes and benefit to the environment. Through various techniques and solutions for lighting, heating, office equipment, the building fabric etc along with a change in people’s attitudes there can be a substantial saving in the amount spent on energy. A good example o f energy waste in GMIT is the lighting situation in the library. All the lights are switched on all day on even in places where that is adequate daylighting, which is a big waste o f energy. Also the lights for book shelves are left on. Surely all these books won’t be searched for all at the one time. It would make much more sense to have local switches that the users can control when they are searching for a particular book. Heating controls for the older parts o f the college are badly needed. A room like 834 needs a TRV to prevent it from overheating as temperatures often reach the high twenties due to the heat from the radiators, computers, solar gains and heat from users o f the room. Also in the old part o f the college it is missing vital insulation, along with not being air tight due to the era when it was built. Pumped bonded bead insulation and sealant around services and gaps can greatly improve the thermal performance o f the building and help achieve a higher BER cert. GMIT should also look at the possibility o f installing a CHP plant to meet the base heating loads. It would meet the requirement o f running 4500 hours a year and would receive some financial support from the Accelerated Capital Allowance. I f people’s attitudes are changed through energy awareness campaigns and a few changes made for more energy efficient equipment, substantial savings can be made in the energy expenditure.
Resumo:
Stand alone solar powered refrigeration and water desalination, two of the most popular and sought after applications of solar energy systems, have been selected as the topic of research for the works presented in this thesis. The water desalination system based on evaporation and condensation was found to be the most suitable one to be powered by solar energy. It has been established that highoutput fast-response solar heat collectors used to achieve high rates of evaporation and reliable solar powered cooling system for faster rates of condensation are the most important factors in achieving increased outputs in solar powered desalination systems. Comprehensive reviews of Solar powered cooling/refrigeration and also water desalination techniques have been presented. In view of the fact that the Institute of Technology, Sligo has a well-established long history of research and development in the production of state of the art high-efficiency fast-response evacuated solar heat collectors it was decided to use this know how in the work described in this thesis. For this reason achieving high rates of evaporation was not a problem. It was, therefore, the question of the solar powered refrigeration that was envisaged to be used in the solar powered desalination tofacilitate rapid condensation of the evaporated water that had to be addressed first. The principles of various solar powered refrigeration techniques have also been reviewed. The first step in work on solar powered refrigeration was to successfully modify a conventional refrigerator working on Platen-Munters design to be powered by highoutput fast-response evacuated solar heat collectors. In this work, which was the first ever successful attempt in the field, temperatures as low as —19°C were achieved in the icebox. A new approach in the use of photovoltaic technology to power a conventional domestic refrigerator was also attempted. This was done by modifying a conventional domestic refrigerator to be powered by photovoltaic panels in the most efficient way. In the system developed and successfully tested in this approach, the power demand has been reduced phenomenally and it is possible to achieve 48 hours of cooling power with exposure to just 7 hours of sunshine. The successful development of the first ever multi-cycle intermittent solar powered icemaker is without doubt the most exciting breakthrough in the work described in this thesis. Output of 74.3kg of ice per module with total exposure area of 2.88 m2, or 25.73kg per m2, per day is a major improvement in comparison to about 5-6kg of ice per m2 per day reported for all the single cycle intermittent systems. This system has then become the basis for the development of a new solar powered refrigeration system with even higher output, named the “composite” system described in this thesis. Another major breakthrough associated with the works described in this thesis is the successful development and testing of the high-output water desalination system. This system that uses a combination of the high-output fast-response evacuated solar heat collectors and the multi-cycle icemaker. The system is capable of producing a maximum of 141 litres of distilled water per day per module which has an exposure area of 3.24m2, or a production rate of 43.5 litres per m2 per day. Once again when this result is compared to the reported daily output of 5 litres of desalinated water per m per day the significance of this piece of work becomes apparent. In the presentation of many of the components and systems described in this thesis CAD parametric solid modelling has been used instead of photographs to illustrate them more clearly. The multi-cycle icemaker and the high-output desalination systems are the subject of two patent applications.
Resumo:
Background: According to some international studies, patients with acute coronary syndrome (ACS) and increased left atrial volume index (LAVI) have worse long-term prognosis. However, national Brazilian studies confirming this prediction are still lacking. Objective: To evaluate LAVI as a predictor of major cardiovascular events (MCE) in patients with ACS during a 365-day follow-up. Methods: Prospective cohort of 171 patients diagnosed with ACS whose LAVI was calculated within 48 hours after hospital admission. According to LAVI, two groups were categorized: normal LAVI (≤ 32 mL/m2) and increased LAVI (> 32 mL/m2). Both groups were compared regarding clinical and echocardiographic characteristics, in- and out-of-hospital outcomes, and occurrence of ECM in up to 365 days. Results: Increased LAVI was observed in 78 patients (45%), and was associated with older age, higher body mass index, hypertension, history of myocardial infarction and previous angioplasty, and lower creatinine clearance and ejection fraction. During hospitalization, acute pulmonary edema was more frequent in patients with increased LAVI (14.1% vs. 4.3%, p = 0.024). After discharge, the occurrence of combined outcome for MCE was higher (p = 0.001) in the group with increased LAVI (26%) as compared to the normal LAVI group (7%) [RR (95% CI) = 3.46 (1.54-7.73) vs. 0.80 (0.69-0.92)]. After Cox regression, increased LAVI increased the probability of MCE (HR = 3.08, 95% CI = 1.28-7.40, p = 0.012). Conclusion: Increased LAVI is an important predictor of MCE in a one-year follow-up.
Resumo:
Dezentrale Energieversorgung; Regenerative Energien; Kraft-Wärme-Kopplung; Windkraft; Photovoltaik; Solarthermie; Kraft-Wärme-Kälte-Kopplung; Bewertungskriterien dezentraler Energieversorgung
Resumo:
In the field of agrometeorological studies we are in need of the estimation of the solar radiation frequently. At the present study the authors have worked out some dat:t regarding the hours of sunshine during the months of August, September, October, November, December and January of 1957, 1958 and 1959. Based on such hours of sunshine in the Agrometeorological Station, located at the Escola Superior de Agricultura "Luiz de Queiroz" - U.S. P., in Piracicaba, the authors calculated the solar radiation received on a plane and horizontal surface, from the method proposed by Glover and Mc Culloch. With those results the authors estimated the percentual part of radiation that would be received on vertical wall facing north.
Resumo:
O efeito da orientação cardial de uma parcela experimental sobre a variação de temperatura do solo foi estudado. Verificou-se que à latitude de 15°S, a parcela com uma inclinação de rampa de 5% apresentou diferenças mensuráveis entre as temperaturas do solo nas diversas faces de exposição, sendo mais salientes as diferenças entre as faces Norte e Sul. Os dados obtidos foram coerentes com as determinações de radiação solar recebida.
Resumo:
The present paper refers to a research work carried out at the Dept. of Agriculture and Horticulture of ESALQ, University of São Paulo, in Piracicaba, State of São Paulo (latitude 22º42'S, longitude 47º33' WG and altitude 546 m). Sowing at different times and using artificial cover, an attempt was made to evaluate the behavior of cultivar IAC 17 of cotton (Gossypium hirsutum L.) as to production and quality of fiber relating to incident solar radiation. Incident solar radiation, as well as insolation during the trial period, were tabulated and compared with yelds and agricultural and technological characters of fibers. The treatment under cover showed a mean level of incident solar radiation equivalent to less than 20% of that at clear sky, causing a decrease in cotton production and in the agricultural and technological characters of fibers.
Resumo:
O presente trabalho se propõe a verificar de que modo a orientação de uma edificação rural influe na carga térmica radiante (radiação solar) interceptada pela mesma. Duas situações freqüentemente encontradas na prática são examinadas: a orientação Norte-Sul e a Leste-Oeste. Para determinar a carga térmica radiante, de importância nos problemas deventilação e refrigeração, é adotado um modelo de construção a título de exemplo, sendo que as relações aqui propostas são aplicáveis a qualquer modelo de construção desejado. Os resultados mostraram quea carga térmica radiante da exposição Leste-Oeste chega a ser 74% da carga na exposição Norte-Sul.