837 resultados para Self-Description Questionnaire III


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Internet data collection is becoming increasingly popular in all research fields dealing with human perceptions, behaviors and opinions. Advantages of internet data collection, when compared to the traditional paper-and-pencil format, include reduced costs, automatic database creation, and the absence of researcher-related bias effects, such as availability and complete anonymity. However, the validity and reliability of internet gathered data must be established, in comparison to the usual paper-and-pencil accepted formats, before an inferential analysis can be done. In this study, we compared questionnaire data gathered from the internet with that from the traditional paper-and-pencil in a sample of college students. The questionnaires used were the Maslach Burnout Inventory - Student Survey (MBI-SS), the Oldenburg Burnout Inventory (OBI-SS) and the Copenhagen Burnout Inventory (CBI-SS). Data was gathered through a within-subject cross randomized and counterbalanced design, on both internet and paper-and-pencil formats. The results showed no interference in the application order, and a good reliability for both formats. However, concordance between answers was generally higher in the paper-and-pencil format than on the internet. The factorial structure was invariant in the three burnout inventories. Data gathered in this study supports the Internet as a convenient, user-friendly, comfortable and secure data gathering method which does not affect the accepted factorial structures existent in the paper format of the three burnout inventories used. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the bond strength to enamel between resin cements combined with total-etch and self-etch adhesive systems and a self-adhesive cement. Eighty bovine incisors had their buccal surface ground flat exposing a plane area in the enamel. Eighty Artglass resin cylinders measuring 3 mm in diameter and 4 mm in height were fabricated. The teeth were divided into eight groups of 10 teeth each and the resin cylinders were cemented with different adhesive systems and resin cements; G1: RelyX Unicem (self-adhesive cement); G2: H 3PO 4 + Single Bond + RelyX ARC; G3: AdheSE + Variolink II; G4: H 3PO 4 + Excite + Variolink II; G5: Xeno III + Enforce; G6: H 3PO 4 + Prime&Bond NT + Enforce; G7: Biatite Primers 1 and 2 + Bistite II DC; G8: H 3PO 4 + Bistite Primers 1 and 2 + Bistite II DC. After application of the adhesives, the cylinders were cemented according to manufacturer instructions. The specimens were submitted to 2000 thermal cycles at a temperature ranging from 5±5°C to 55±5°C, and shear bond strength was then tested at a variety of 1 mm/min. The data were analyzed by ANOVA and the Tukey's test (á=5%), obtaining a p value of 0.00. The following mean (±standard deviation) bond strength values were observed for each group: G1: 5.14(±0.99)a; G3: 16.23(±4.69)b; G7: 17.82(±3.66)b; G5: 18.48(±2.88)bc; G8: 20.15(±4.12)bc; G4: 22.85(±3.08)cd; G2: 24.96(±2.89)d; G6: 26.07(±1.69)d. Groups followed by the same letters did not differ significantly. For most of the resin cements tested, the application of adhesive systems using acid etching resulted in a higher bond strength when compared to the self-etch adhesive systems and to the self-adhesive cement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies of the hemoglobin pattern in Brazilian reptiles are important for determining ecological and phylogenetic relationships, but they are scarce. Peripheral blood samples were obtained from 7 males and 18 females of Rhinoclemmys punctularia. The hematological profile was based on the total hemoglobin and hematocrit values. The hemoglobin profile was obtained using electrophoretic procedures at different pH, isoelectric focusing, globin chain electrophoresis, and HPLC. The hematocrit (31 ± 2%) and total hemoglobin (7.5 ± 0.2 g/dL) values did not indicate gender variations. Alkaline pH electrophoresis of the total blood samples treated with 1% saponin demonstrated the presence of four well-defined hemoglobin fractions, one major component (fraction I), showing cathodic migration and three others faster than fraction I with anodic migration. When the samples were precipitated with chloroform, only two hemoglobin fractions were observed, similar to fractions I and III from the first procedure. Isoelectric focusing and HPLC showed the same pattern. With acid and neutral pH electrophoresis, two fractions with anodic migration were observed. The globin chain identification at alkaline pH showed two fractions, but four fractions were observed at acidic pH, suggesting that different polypeptide chains are involved in the hemoglobin molecule. The chromatographic separation of the total blood sample demonstrated that the major fraction comprised 81.9% and the minor 18.1%. The results obtained demonstrated a similarity between these hemoglobin components and those of some Chelidae reported in the literature for both land and aquatic animals, reflecting the adaptation to environmental conditions. ©FUNPEC-RP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the penetration (tags) of adhesive materials into enamel etched with phosphoric acid or treated with a self-etching adhesive, before application of a pit-and-fissure sealant. MATERIALS AND METHODS: The sample comprised six study groups with six specimens each. Before pit-and-fissure sealing with the materials Clinpro SealantTM (Groups I and II), Vitro Seal ALPHA (Groups III and IV) and Fuji II LC (Groups V and VI), the teeth in Groups I, III, and V were etched with 35% phosphoric acid for 30 seconds. Teeth in Groups II, IV, and VI received application of the self-etching adhesive Adper Prompt L-Pop. The treated teeth were sectioned buccolingually, ground to 100-microm thickness, decalcified, and analyzed by conventional light microscopy at 400x magnification. RESULTS: The teeth etched with phosphoric acid exhibited significantly greater penetration than specimens treated with self-etching adhesive. CLINICAL SIGNIFICANCE: When compared with enamel treated with a self-etching adhesive, the penetration (tags) of adhesive materials into enamel was greater when applied on enamel etched with phosphoric acid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Web service-based application is an architectural style, where a collection of Web services communicates to each other to execute processes. With the popularity increase of developing Web service-based application and once Web services may change, in terms of functional and non-functional Quality of Service (QoS), we need mechanisms to monitor, diagnose, and repair Web services into a Web Application. This work presents a description of self-healing architecture that deals with these mechanisms. Other contributions of this paper are using the proxy server to measure Web service QoS values and to employ some strategies to recovery the effects from misbehaved Web services. © 2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Psicologia do Desenvolvimento e Aprendizagem - FC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: There are no reported cases of factitious or simulated obsessive compulsive disorder (OCD). However, over the last years, our clinic has come across a number of individuals that seem to exaggerate, mislabel or even intentionally produce obsessive and/or compulsive symptoms in order to be diagnosed with OCD.Methods: In this study, experienced clinicians working on a university-based OCD clinic were requested to provide clinical vignettes of patients who, despite having a formal diagnosis of OCD, were felt to display non-genuine forms of this condition.Results: Ten non-consecutive patients with a self-proclaimed diagnosis of OCD were identified and described. Although patients were diagnosed with OCD according to various structured interviews, they exhibited diverse combinations of the following features: (i) overly technical and/or doctrinaire description of their symptoms, (ii) mounting irritability, as the interviewer attempts to unveil the underlying nature of these descriptions; (iii) marked shifts in symptom patterns and disease course; (iv) an affirmative yes pattern of response to interview questions; (v) multiple Axis I psychiatric disorders; (vi) cluster B features; (vii) an erratic pattern of treatment response; and (viii) excessive or contradictory drug-related side effects.Conclusions: In sum, reliance on overly structured assessments conducted by insufficiently trained or naive personnel may result in invalid OCD diagnoses, particularly those that leave no room for clinical judgment. (C) 2014 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs).Material and Methods: Two hundred Class III, IV, and V composite restorations were placed into 50 patients. Each patient received four composite restorations (Amaris, Voco), and these restorations were bonded with one of three 1-SEAs (Futurabond M, Voco; Clearfil S3 Bond, Kuraray; and Optibond All-in-One, Kerr) or one 2-ERA (Adper Single Bond 2/3M ESPE). The four adhesive systems were evaluated at baseline and after 24 months using the following criteria: restoration retention, marginal integrity, marginal discoloration, caries occurrence, postoperative sensitivity and preservation of tooth vitality. After two years, 162 restorations were evaluated in 41 patients. Data were analyzed using the chi(2) test (p<0.05).Results: There were no statistically significant differences between the 2-ERA and the 1-SEAs regarding the evaluated parameters (p>0.05).Conclusion: The 1-SEAs showed good clinical performance at the end of 24 months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the influence of Nd:YAG laser on the shear bond strength to enamel and dentin of total and self-etch adhesives when the laser was applied over the adhesives, before they were photopolymerized, in an attempt to create a new bonding layer by dentin-adhesive melting.Material and Methods: One-hundred twenty bovine incisors were ground to obtain flat surfaces. Specimens were divided into two substrate groups (n=60): substrate E (enamel) and substrate D (dentin). Each substrate group was subdivided into four groups (n=15), according to the surface treatment accomplished: X (Xeno III self-etching adhesive, control), XL (Xeno III + laser Nd:YAG irradiation at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental), S (acid etching + Single Bond conventional adhesive, Control), and SL (acid etching + Single Bond + laser Nd:YAG at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental). The bonding area was delimited with 3-mm-diameter adhesive tape for the bonding procedures. Cylinders of composite were fabricated on the bonding area using a Teflon matrix. The teeth were stored in water at 37 degrees C/48 h and submitted to shear testing at a crosshead speed of 0.5 mm/min in a universal testing machine. Results were analyzed with three-way analysis of variance (ANOVA; substrate, adhesive, and treatment) and Tukey tests (alpha=0.05). ANOVA revealed significant differences for the substrate, adhesive system, and type of treatment: lased or unlased (p<0.05). The mean shear bond strength values (MPa) for the enamel groups were X=20.2 +/- 5.61, XL=23.6 +/- 4.92, S=20.8 +/- 4.55, SL=22.1 +/- 5.14 and for the dentin groups were X=14.1 +/- 7.51, XL=22.2 +/- 6.45, S=11.2 +/- 5.77, SL=15.9 +/- 3.61. For dentin, Xeno III self-etch adhesive showed significantly higher shear bond strength compared with Single Bond total-etch adhesive; Nd:YAG laser irradiation showed significantly higher shear bond strength compared with control (unlased).Conclusion: Nd:YAG laser application prior to photopolymerization of adhesive systems significantly increased the bond strength to dentin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Saúde Coletiva - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)