951 resultados para Reproducibility
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
Objective: To determine the presence of linear relationship between renal cortical thickness, bipolar length, and parenchymal thickness in chronic kidney disease patients presenting with different estimated glomerular filtration rates (GFRs) and to assess the reproducibility of these measurements using ultrasonography. Materials and Methods: Ultrasonography was performed in 54 chronic renal failure patients. The scans were performed by two independent and blinded radiologists. The estimated GFR was calculated using the Cockcroft-Gault equation. Interobserver agreement was calculated and a linear correlation coefficient (r) was determined in order to establish the relationship between the different renal measurements and estimated GFR. Results: The correlation between GFR and measurements of renal cortical thickness, bipolar length, and parenchymal thickness was, respectively, moderate (r = 0.478; p < 0.001), poor (r = 0.380; p = 0.004), and poor (r = 0.277; p = 0.116). The interobserver agreement was considered excellent (0.754) for measurements of cortical thickness and bipolar length (0.833), and satisfactory for parenchymal thickness (0.523). Conclusion: The interobserver reproducibility for renal measurements obtained was good. A moderate correlation was observed between estimated GFR and cortical thickness, but bipolar length and parenchymal thickness were poorly correlated.
Resumo:
P-glycoprotein (Pgp), a protein codified by Multi Drug Resistance (MDR1) gene, has a detoxifying function and might influence the toxicity and pharmacokinetics and pharmacodynamics of drugs. Sampling strategies to improve Pgp studies could be useful to optimize the sensitivity and the reproducibility of efflux assays. This study aimed to compare Pgp expression and efflux activity by measuring Rhodamine123 (Rh123) retention in lymphocytes stored under different conditions, in order to evaluate the potential utility of any of the storing conditions in Pgp functionality. Our results show no change in protein expression of Pgp by confocal studies and Western blotting, nor changes at the mRNA level (qRT-PCR). No differences in Rh123 efflux by Pgp activity assays were found between fresh and frozen lymphocytes after 24 hours of blood extraction, using either of the two Pgp specific inhibitors (VP and PSC833). Different working conditions in the 24 hours post blood extraction do not affect Rh123 efflux. These results allow standardization of Pgp activity measurement in different individuals with different timing of blood sampling and in different geographic areas. _______________
Resumo:
The classical volumetric titration of Fe2+ with MnO4-, used in some routine analysis as well as in undergraduate courses was improved. SnCl2 (to reduce Fe3+ to Fe2+) and HgCl2 (to oxidize excess SnCl2) were substituted by metallic zinc in boiling solutions, thus avoiding the toxic HgCl2 and Hg2Cl2; nitrate ions do not interfere in the improved methodology (it is an interference in the classical one) and the reproducibility of the determinations is increased by using metallic zinc. Determinations by students of undergraduate courses are discussed.
Desenvolvimento de um sistema de filtração e titulação para determinação da acidez de ácidos húmicos
Resumo:
The acidity determinations method of humic acids (HA) content was developed by Schnitzer and Gupta and is a very well known procedure. Nevertheless, care is necessary to prevent measure errors due to non-controlled BaCO3 production, during the filtration and titration of HA total acidity. To overcome this problem, we developed in our laboratory a simple filtration and titration system for the determination of HA acidity under inert atmosphere. This system enables a better reproducibility and accuracy of total, carboxylic and phenolic acidity measures than those by Schnitzer and Gupta method.
Resumo:
This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.
Resumo:
The susceptibility of Drosophila melanogaster to carbofuran and the use of this organism in biomonitoring residues of the insecticide in cabbage was evaluated. Under the conditions of the bioassay, residues-film bioassay in Petri dish, carbofuran degraded depending on the temperature and time of exposure. Bioassays conducted with D. melanogaster showed that its toxicity increases with temperature (20 to 35 °C). LC50 values, calculated as a function of temperature, ranged from 3.6 to 10.5 mg/g body weight (bw) for males and from 2.9 to 8.7 mg/g bw for females. The formulated product Furadan® G was applied on cabbage (Brassica oleracea, var. capitata) and the residues of carbofuran were determined by bioassay. The determination limit of the bioassay was 0.1 mg/kg and the method presented reproducibility with coefficient variation of 17 %. The validation of the bioassay by high performance liquid chromatography confirms the viability of the bioassay with D. melanogaster in monitoring the residues of carbofuran in cabbage.
Resumo:
Values of repeatability (r) and reproducibility (R) are parameters of an analytical method. They are related to the maximum difference between two results of analysis (permissible range) and can be obtained by interlaboratorial comparisons. They represent great importance for the quality control of the results and decisions about the fitness-for-purpose of the method. Water determination in fuel oil samples were performed by 16 laboratories, using the Karl Fischer reaction, during the period from June 1997 to December 1999. Values of r and R were presented. Discussion is made in terms of the main factors that would be contribution to analytical method variabilities and uncertainties of final results.
Resumo:
Quantitative GC-FID was evaluated for analysis of methylated copaiba oils, using trans-(-)-caryophyllene or methyl copalate as external standards. Analytical curves showed good linearity and reproducibility in terms of correlation coefficients (0.9992 and 0.996, respectively) and relative standard deviation (< 3%). Quantification of sesquiterpenes and diterpenic acids were performed with each standard, separately. When compared with the integrator response normalization, the standardization was statistically similar for the case of methyl copalate, but the response of trans-(-)-caryophyllene was statistically (P < 0.05) different. This method showed to be suitable for classification and quality control of commercial samples of the oils.
Resumo:
Normally, the determination of equilibrium constants (k d) in batch experiments uses a high solution to soil ratio, which does not represent field conditions. In this study we present an alternative method to evaluate adsorption constants, using micro-columns of soil at higher soil to solution ratios. The centrifugation force and equilibration time were investigated. The triadimenol distribution along the column profile is controlled by diffusion and equilibration times greater than 24 h are needed to achieve reproducibility. The centrifugation force must be superior to 670 g in order to guarantee enough extraction of the liquid solution from the soil columns.
Resumo:
A simple low-cost flow cell was developed, built and optimized in order to observe dynamic interfacial tension of continuous flow systems. Distinct materials can be used in one of the cell walls in order to observe the intermolecular forces between the flowing liquid and the chemical constitution of the walls. The fluorescence depolarization was evaluated using Rhodamine B as fluorescent probe seeded in ethylene glycol. The effects of the positioning angles on the data acquired across the cell are reported. The reproducibility of the data was evaluated with a spectrometer assembled in-house and the relative standard deviation was below 3%.
Resumo:
The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their molecules and the negative charge of the sulfonate group of the Nafion®, which causes leaching of the dye from the membrane. On the other hand, MV showed to be suitable due to the presence of positive groups in its structure. The membrane prepared from a methanolic solution whose Nafion®/dye molar ratio was 20 presented the best analytical properties, changing its color from green to violet in the pH range from 0.6 to 3.0. The membrane can be prepared with good reproducibility, presenting durability of ca. 6 months and response time of 22 s, making possible its use for pH determination in flow analysis systems.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
In spite of the availability of large databases of chromatographic data on several standardized systems, one major task in systematic toxicological analysis remains, namely how to handle the experimental data and retrieve data from the large available databases in a meaningful and productive way. To achieve this purpose, our group proposed an Internet-based tool using previously published STA databases, which interlaboratorial reproducibility tests have already evaluated. The developed software has the capability to calculate corrected chromatographic parameters, after the input of data obtained with standard mixtures of calibrators, and search the databases, currently incorporating TLC, color reactions, GC and HPLC data. At the end of the process, a list with candidate substances and their similarity indexes is presented.
Resumo:
In terms of soil fertility, zinc is a micronutrient that is very important in the culture of soy, maize, rice and coffee, because it is a structural and functional component of a great number of enzymes. Therefore, diverse methods have been used to determine zinc in soil. In this work we use colorimetry as a methods of zinc determination in soil using two methodologies of sample digesting, H2SO4/H2O2 and HNO3/H2O2. In order to compare the results, atomic absorption spectrometry (AAS) was used. Results show that colorimetric methods can be used due to good sensitivity and reproducibility, since the zinc calibration curve showed good linearity. Comparing colorimetric methods with AAS we observed that the results were equivalent, as proven by the statistical values of the F and t of Student tests. Furthermore, both methods of soil digesting can be used, leading to a flexible methodology of low-cost for routine zinc analyses in soil.