875 resultados para Reliability of distribution system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is a crucial task to evaluate the reliability of manufacturing process in product development process. Process reliability is a measurement of production ability of reconfigurable manufacturing system (RMS), which serves as an integrated performance indicator of the production process under specified technical constraints, including time, cost and quality. An integration framework of manufacturing process reliability evaluation is presented together with product development process. A mathematical model and algorithm based on universal generating function (UGF) is developed for calculating the reliability of manufacturing process with respect to task intensity and process capacity, which are both independent random variables. The rework strategies of RMS are analyzed under different task intensity based on process reliability is presented, and the optimization of rework strategies based on process reliability is discussed afterwards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional reliability models for parallel systems are not applicable for the analysis of parallel systems with load transfer and sharing. In this short communication, firstly, the dependent failures of parallel systems are analyzed, and the reliability model of load-sharing parallel system is presented based on Miner cumulative damage theory and the full probability formula. Secondly, the parallel system reliability is calculated by Monte Carlo simulation when the component life follows the Weibull distribution. The research result shows that the proposed reliability mathematical model could analyze and evaluate the reliability of parallel systems in the presence of load transfer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis studies the state-of-the-art of phasor measurement units (PMUs) as well as their metrological requirements stated in the IEEE C37.118.1 and C37.118.2 Standards for guaranteeing correct measurement performances. Communication systems among PMUs and their possible applicability in the field of power quality (PQ) assessment are also investigated. This preliminary study is followed by an analysis of the working principle of real-time (RT) simulators and the importance of hardware-in-the-loop (HIL) implementation, examining the possible case studies specific for PMUs, including compliance tests which are one of the most important parts. The core of the thesis is focused on the implementation of a PMU model in the IEEE 5-bus network in Simulink and in the validation of the results using OPAL RT-4510 as a real-time simulator. An initial check allows one to get an idea about the goodness of the results in Simulink, comparing the PMU data with respect to the load-flow steady-state information. In this part, accuracy indices are also calculated for both voltage and current synchrophasors. The following part consists in the implementation of the same code in OPAL-RT 4510 simulator, after which an initial analysis is carried out in a qualitative way in order to get a sense of the goodness of the outcomes. Finally, the confirmation of the results is based on an examination of the attained voltage and current synchrophasors and accuracy indices coming from Simulink models and from OPAL system, using a Matlab script. This work also proposes suggestions for an upcoming operation of PMUs in a more complex system as the Digital Twin (DT) in order to improve the performances of the already-existing protection devices of the distribution system operator (DSO) for a future enhancement of power systems reliability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the completeness and reliability of the Information System on Live Births (Sinasc) data. A cross-sectional analysis of the reliability and completeness of Sinasc's data was performed using a sample of Live Birth Certificate (LBC) from 2009, related to births from Campinas, Southeast Brazil. For data analysis, hospitals were grouped according to category of service (Unified National Health System, private or both), 600 LBCs were randomly selected and the data were collected in LBC-copies through mothers and newborns' hospital records and by telephone interviews. The completeness of LBCs was evaluated, calculating the percentage of blank fields, and the LBCs agreement comparing the originals with the copies was evaluated by Kappa and intraclass correlation coefficients. The percentage of completeness of LBCs ranged from 99.8%-100%. For the most items, the agreement was excellent. However, the agreement was acceptable for marital status, maternal education and newborn infants' race/color, low for prenatal visits and presence of birth defects, and very low for the number of deceased children. The results showed that the municipality Sinasc is reliable for most of the studied variables. Investments in training of the professionals are suggested in an attempt to improve system capacity to support planning and implementation of health activities for the benefit of maternal and child population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe an estimation technique for biomass burning emissions in South America based on a combination of remote-sensing fire products and field observations, the Brazilian Biomass Burning Emission Model (3BEM). For each fire pixel detected by remote sensing, the mass of the emitted tracer is calculated based on field observations of fire properties related to the type of vegetation burning. The burnt area is estimated from the instantaneous fire size retrieved by remote sensing, when available, or from statistical properties of the burn scars. The sources are then spatially and temporally distributed and assimilated daily by the Coupled Aerosol and Tracer Transport model to the Brazilian developments on the Regional Atmospheric Modeling System (CATT-BRAMS) in order to perform the prognosis of related tracer concentrations. Three other biomass burning inventories, including GFEDv2 and EDGAR, are simultaneously used to compare the emission strength in terms of the resultant tracer distribution. We also assess the effect of using the daily time resolution of fire emissions by including runs with monthly-averaged emissions. We evaluate the performance of the model using the different emission estimation techniques by comparing the model results with direct measurements of carbon monoxide both near-surface and airborne, as well as remote sensing derived products. The model results obtained using the 3BEM methodology of estimation introduced in this paper show relatively good agreement with the direct measurements and MOPITT data product, suggesting the reliability of the model at local to regional scales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of this paper is to present architecture of automated system that allows monitoring and tracking in real time (online) the possible occurrence of faults and electromagnetic transients observed in primary power distribution networks. Through the interconnection of this automated system to the utility operation center, it will be possible to provide an efficient tool that will assist in decisionmaking by the Operation Center. In short, the desired purpose aims to have all tools necessary to identify, almost instantaneously, the occurrence of faults and transient disturbances in the primary power distribution system, as well as to determine its respective origin and probable location. The compilations of results from the application of this automated system show that the developed techniques provide accurate results, identifying and locating several occurrences of faults observed in the distribution system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a reliability-based analysis for calculating critical tool life in machining processes. It is possible to determine the running time for each tool involved in the process by obtaining the operations sequence for the machining procedure. Usually, the reliability of an operation depends on three independent factors: operator, machine-tool and cutting tool. The reliability of a part manufacturing process is mainly determined by the cutting time for each job and by the sequence of operations, defined by the series configuration. An algorithm is presented to define when the cutting tool must be changed. The proposed algorithm is used to evaluate the reliability of a manufacturing process composed of turning and drilling operations. The reliability of the turning operation is modeled based on data presented in the literature, and from experimental results, a statistical distribution of drilling tool wear was defined, and the reliability of the drilling process was modeled. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An algorithm inspired on ant behavior is developed in order to find out the topology of an electric energy distribution network with minimum power loss. The algorithm performance is investigated in hypothetical and actual circuits. When applied in an actual distribution system of a region of the State of Sao Paulo (Brazil), the solution found by the algorithm presents loss lower than the topology built by the concessionary company.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the effect of sensor placement on the performance of a disease-warning system for sooty blotch and flyspeck (SBFS), we measured leaf wetness duration (LWD) at 12 canopy positions in apple trees, then simulated operation of the disease-warning system using LWD measurements from different parts of the canopy. LWD sensors were placed in four trees within one Iowa orchard during two growing seasons, and in one tree in each of four orchards during a single growing season. The LWD measurements revealed substantial heterogeneity among sensor locations. In all data sets, the upper, eastern portion of the canopy had the longest mean daily LWD, and was the first site to form dew and the last to dry. The lower, western portion of the canopy averaged about 3 It less LWD per day than the top of the canopy, and was the last zone where dew formed and the first to dry off. On about 25% of nights when dew occurred in the top of the canopy, no dew formed in the lower, western canopy. Intracanopy variability of LWD was more pronounced when dew was the sole source of wetness than on days when rainfall occurred. Daily LWD in the upper, eastern portion of the canopy was slightly less than reference measurements made at a 0.7-m height over turfgrass located near the orchard. When LWD measurements from several canopy positions were input to the SBFS warning system, timing of occurrence of a fungicide-spray threshold varied by as much as 30 days among canopy positions. Under Iowa conditions, placement of an LWD sensor at an unobstructed site over turfgrass was a fairly accurate surrogate for the wettest part of the canopy. Therefore, such an extra-canopy LWD sensor might be substituted for a within-canopy sensor to enhance operational reliability of the SBFS warning system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Much information on flavonoid content of Brazilian foods has already been obtained; however, this information is spread in scientific publications and non-published data. The objectives of this work were to compile and evaluate the quality of national flavonoid data according to the United States Department of Agriculture`s Data Quality Evaluation System (USDA-DQES) with few modifications, for future dissemination in the TBCA-USP (Brazilian Food Composition Database). For the compilation, the most abundant compounds in the flavonoid subclasses were considered (flavonols, flavones, isoflavones, flavanones, flavan-3-ols, and anthocyanidins) and the analysis of the compounds by HPLC was adopted as criteria for data inclusion. The evaluation system considers five categories, and the maximum score assigned to each category is 20. For each data, a confidence code (CC) was attributed (A, B, C and D), indicating the quality and reliability of the information. Flavonoid data (773) present in 197 Brazilian foods were evaluated. The CC ""C"" (as average) was attributed to 99% of the data and ""B"" (above average) to 1%. The main categories assigned low average scores were: number of samples; sampling plan and analytical quality control (average scores 2, 5 and 4, respectively). The analytical method category received an average score of 9. The category assigned the highest score was the sample handling (20 average). These results show that researchers need to be conscious about the importance of the number and plan of evaluated samples and the complete description and documentation of all the processes of methodology execution and analytical quality control. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study determined the inter-tester and intra-tester reliability of physiotherapists measuring functional motor ability of traumatic brain injury clients using the Clinical Outcomes Variable Scale (COVS). To test inter-tester reliability, 14 physiotherapists scored the ability of 16 videotaped patients to execute the items that comprise the COVS. Intra-tester reliability was determined by four physiotherapists repeating their assessments after one week, and three months later. The intra-class correlation coefficients (ICC) were very high for both inter-tester reliability (ICC > 0.97 for total COVS scores, ICC > 0.93 for individual COVS items) and intra-tester reliability (ICC > 0.97). This study demonstrates that physiotherapists are reliable in the administration of the COVS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. Evaluate the effect of testing system compliance on polymerization stress and stress distribution of composites. Methods. Composites tested were Filtek Z250 (FZ), Herculite (HL), Tetric Ceram (TC), Helio Fill-AP (HF) and Heliomolar (HM). Stress was determined in 1-mm thick specimens, inserted between two rods of either poly(methyl methacrylate), PMMA, or glass. Experimental nominal stress (sigma(exp)) was calculated by dividing the maximum force recorded 5 min after photoactivation by the cross-sectional area of the rod. Composites` elastic modulus (E) was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey`s test (alpha = 0.05). Stress distribution on longitudinal (sigma(y)) and transverse (sigma(x)) axes of models representing the composites with the highest and lowest E (FZ and HM, respectively) were evaluated by finite element analysis (FEA). Results. sigma(exp) ranged from 5.5 to 8.8 MPa in glass and from 2.6 to 3.4 MPa in PMMA. Composite ranking was not identical in both substrates, since FZ showed or sigma(exp) statistically higher than HM in glass, while in PMMA FZ showed values similar to the other composites. A strong correlation was found between stress reduction (%) from glass to PMMA and composite`s E (r(2) = 0.946). FEA revealed that system compliance was influenced by the composite (FZ led to higher compliance than HM). sigma(x) distribution was similar in both substrates, while cry distribution showed larger areas of compressive stresses in specimens built on PMMA. Significance. sigma(exp) determined in PMMA was 53-68% lower than in glass. Composite ranking varied slightly due to differences in substrates` longitudinal and transverse deformation. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To determine the bond strength to unground enamel of all in one adhesives in comparison with an etch and rinse system and to compare the reliability of microtensile and microshear methods in providing such measurements Materials and Methods The bonding procedure was performed on enamel of 64 extracted molars The tested all in one adhesives were Bond Force (Tokuyama), AdheSE One (Ivoclar Vivadent) and Xeno V (Dentsply) Prime&Bond NT (Dentsply) served as control Microtensile specimens were obtained from 4 teeth per group Twelve teeth per group were used for microshear testing Microtensile specimens that failed prior to testing were included in statistical calculations, they were assigned the lowest value measured in the respective group Failure modes were observed under light microscope and classified (cohesive within substrates, adhesive mixed) Statistically significant differences in bond strength were assessed among the adhesives within each testing method and between microshear and microtensile data for each adhesive Failure mode distributions were compared using the chi square test Results All in-one adhesives had similar microshear and microtensile bond strengths In both testing methods, the etch and rinse system achieved the strongest bond For all adhesives significantly higher bond strengths were measured with the microshear test In microtensile testing specimens bonded with the etch and rinse adhesive exhibited a significantly different distribution of failure modes The coefficients of variation were extremely high for microtensile bond strength data, particularly of all in one adhesives Conclusion The adhesive potential to intact enamel of recently introduced all in-one adhesives was inferior to that of an etch and rinse system When testing bond strength to enamel of all in one adhesives, microshear testing may be a more accurate method than microtensile