973 resultados para Reference measurements
Resumo:
The autonomic nervous system is an important modulator of ventricular repolarization and arrhythmia vulnerability. This study explored the effects of cardiovascular autonomic function tests on repolarization and its heterogeneity, with a special reference to congenital arrhythmogenic disorders typically associated with stress-induced fatal ventricular arrhythmias. The first part explored the effects of standardized autonomic tests on QT intervals in a 12-lead electrocardiogram and in multichannel magnetocardiography in 10 healthy adults. The second part studied the effects of deep breathing, Valsalva manouvre, mental stress, sustained handgrip and mild exercise on QT intervals in asymptomatic patients with LQT1 subtype of the hereditary long QT syndrome (n=9) and in patients with arrhythmogenic right ventricular dysplasia (ARVD, n=9). Even strong sympathetic activation had no effects on spatial QT interval dispersion in healthy subjects, but deep respiratory efforts and Valsalva influenced it in ways that were opposite in electrocardiographic and magnetocardiographic recordings. LQT1 patients showed blunted QT interval and sinus nodal responses to sympathetic challenge, as well as an exaggerated QT prolongation during the recovery phases. LQT1 patients showed a QT interval recovery overshoot in 2.4 ± 1.7 tests compared with 0.8 ± 0.7 in healthy controls (P = 0.02). Valsalva strain prolonged the T wave peak to T wave end interval only in the LQT1 patients, considered to reflect the arrhythmogenic substrate in this syndrome. ARVD patients showed signs of abnormal repolarization in the right ventricle, modulated by abrupt sympathetic activation. An electrocardiographic marker reflecting interventricular dispersion of repolarization was introduced. It showed that LQT1 patients exhibit a repolarization gradient from the left ventricle towards the right ventricle, significantly larger than in controls. In contrast, ARVD patients showed a repolarization gradient from the right ventricle towards the left. Valsalva strain amplified the repolarization gradient in LQT1 patients whereas it transiently reversed it in patients with ARVD. In conclusion, intrathoracic volume and pressure changes influence regional electrocardiographic and magnetocardiographic QT interval measurements differently. Especially recovery phases of standard cardiovascular autonomic functions tests and Valsalva manoeuvre reveal the abnormal repolarization in asymptomatic LQT1 patients. Both LQT1 and ARVD patients have abnormal interventricular repolarization gradients, modulated by abrupt sympathetic activation. Autonomic testing and in particular the Valsalva manoeuvre are potentially useful in unmasking abnormal repolarization in these syndromes.
Resumo:
IgA nephropathy (IgAN) is the most common primary glomerulonephritis. In one third of the patients the disease progresses, and they eventually need renal replacement therapy. IgAN is in most cases a slowly progressing disease, and the prediction of progression has been difficult, and the results of studies have been conflicting. Henoch-Schönlein nephritis (HSN) is rare in adults, and prediction of the outcome is even more difficult than in IgAN. This study was conducted to evaluate the clinical and histopathological features and predictors of the outcome of IgAN and HSN diagnosed in one centre (313 IgAN patients and 38 HSN patients), and especially in patients with normal renal function at the time of renal biopsy. The study also aimed to evaluate whether there is a difference in the progression rates in four countries (259 patients from Finland, 112 from UK, 121 from Australia and 274 from Canada), and if so, can this be explained by differences in renal biopsy policy. The third aim was to measure urinary excretions of cytokines interleukin 1ß (IL-1ß) and interleukin 1 receptor antagonist (IL-1ra) in patients with IgAN and HSN and the correlations of excretion of these substances with histopathological damage and clinical factors. A large proportion of the patients diagnosed in Helsinki as having IgAN had normal renal function (161/313 patients). Four factors, (hypertension, higher amounts of urinary erythrocytes, severe arteriolosclerosis and a higher glomerular score) which independently predicted progression (logistic regression analysis), were identified in mild disease. There was geographic variability in renal survival in patients with IgAN. When age, levels of renal function, proteinuria and blood pressure were taken into account, it showed that the variability related mostly to lead-time bias and renal biopsy indications. Amount of proteinuria more than 0.4g/24h was the only factor that was significantly related to the progression of HSN. the Hypertension and the level of renal function were found to be factors predicting outcome in patients with normal renal function at the time of diagnosis. In IgAN patients, IL-1ra excretion into urine was found to be decreased as compared with HSN patients and healthy controls. Patients with a high IL-1ra/IL-1ß ratio had milder histopathological changes in renal biopsy than patients with a low/normal IL-1ra/IL-1ß ratio. It was also found that the excretion of IL-1ß and especially IL-1ra were significantly higher in women. In conclusion, it was shown that factors associated with outcome can reliably be identified even in mild cases of IgAN. Predicting outcome in adult HSN, however, remains difficult.
Resumo:
Based on the measurements of Alcock and Zador, Grundy et al. estimated an uncertainty of the order of +/- 5 kJ mol(-1) for the standard Gibbs energy of formation of MnO in a recent assessment. Since the evaluation of thermodynamic data for the higher oxides Mn3O4, Mn2O3, and MnO2 depends on values for MnO, a redetermination of its Gibbs energy of formation was undertaken in the temperature range from 875 to 1300 K using a solid-state electrochemical cell incorporating yttria-doped thoria (YDT) as the solid electrolyte and Fe + Fe1-delta O as the reference electrode. The cell can be presented as Pt, Mn + MnO/YDT/Fe + Fe1+delta O, Pt Since the metals Fe and Mn undergo phase transitions in the temperature range of measurement, the reversible emf of the cell is represented by the three linear segments. Combining the emf with the oxygen potential for the reference electrode, the standard Gibbs energy of formation of MnO from alpha-Mn and gaseous diatomic oxygen in the temperature range from 875 to 980 K is obtained as: Delta G(f)(o)/Jmol(-1)(+/- 250) = -385624 + 73.071T From 980 to 1300 K the Gibbs energy of formation of MnO from beta-Mn and oxygen gas is given by: Delta G(f)(o)/Jmol(-1)(+/- 250) = -387850 + 75.36T The new data are in excellent agreement with the earlier measurements of Alcock and Zador. Grundy et al. incorrectly analyzed the data of Alcock and Zador showing relatively large difference (+/- 5 kJ mol(-1)) in Gibbs energies of MnO from their two cells with Fe + Fe1-delta O and Ni + NiO as reference electrodes. Thermodynamic data for MnO is reassessed in the light of the new measurements. A table of refined thermodynamic data for MnO from 298.15 to 2000 K is presented.
Resumo:
Background: Brachial plexus birth palsy (BPBP) most often occurs as a result of foetal-maternal disproportion. The C5 and C6 nerve roots of the brachial plexus are most frequently affected. In contrast, roots from the C7 to Th1 that result in total injury together with C5 and C6 injury, are affected in fewer than half of the patients. BPBP was first described by Smellie in 1764. Erb published his classical description of the injury in 1874 and his name became linked with the paralysis that is associated with upper root injury. Since then, early results of brachial plexus surgery have been reasonably well documented. However, from a clinical point of view not all primary results are maintained and there is also a need for later follow-up results. In addition most of the studies that are published emanate from highly specialized clinics and no nation wide epidemiological reports are available. One of the plexus injuries is the avulsion type, in which the nerve root or roots are ruptured at the neural cord. It has been speculated whether this might cause injury to the whole neural system or whether shoulder asymmetry and upper limb inequality results in postural deformities of the spine. Alternatively, avulsion could manifest as other signs and symptoms of the whole musculoskeletal system. In addition, there is no available information covering activities of daily living after obstetric brachial plexus surgery. Patients and methods: This was a population-based cross-sectional study on all patients who had undergone brachial plexus surgery with at least 5 years of follow-up. An incidence of 3.05/1000 for BPBP was obtained from the registers for this study period. A total of 1706 BPBP patients needing hospital treatment out of 1 717 057 newborns were registered in Finland between 1971 and 1997 inclusive. Of these BPBP patients, 124 (7.3%) underwent brachial plexus surgery at a mean age of 2.8 months (range: 0.4―13.2 months). Surgery was most often performed by direct neuroraphy after neuroma resection (53%). Depending on the phase of the study, 105 to 112 patients (85-90%) participated in a clinical and radiological follow-up assessment. The mean follow up time exceeded 13 years (range: 5.0―31.5 years). Functional status of the upper extremity was evaluated using Mallet, Gilbert and Raimondi scales. Isometric strength of the upper limb, sensation of the hand and stereognosis were evaluated for both the affected and unaffected sides then the differences and their ratios were calculated and recorded. In addition to the upper extremity, assessment of the spine and lower extremities were performed. Activities of daily living (ADL), participation in normal physical activities, and the use of physiotherapy and occupational therapy were recorded in a questionnaire. Results: The unaffected limb functioned as the dominant hand in all, except four patients. The mean length of the affected upper limb was 6 cm (range: 1-13.5 cm) shorter in 106 (95%) patients. Shoulder function was recorded as a mean Mallet score of 3 (range: 2―4) which was moderate. Both elbow function and hand function were good. The mean Gilbert elbow scale value was 3 (range: -1―5) and the mean Raimondi hand scale was 4 (range:1―5). One-third of the patients experienced pain in the affected limb including all those patients (n=9) who had clavicular non-union resulting from surgery. A total of 61 patients (57%) had an active shoulder external rotation of less than 0° and an active elbow extension deficiency was noted in 82 patients (77%) giving a mean of 26° (range: 5°―80°). In all, expect two patients, shoulder external rotation strength at a mean ratio 35% (range: 0―83%) and in all patients elbow flexion strength at a mean ratio of 41% (range: 0―79%) were impaired compared to the unaffected side. According to radiographs, incongruence of the glenohumeral joint was noted in 15 (16%) patients, whereas incongruence of the radiohumeral joint was found in 20 (21%) patients. Fine sensation was normal for 34/49 (69%) patients with C5-6 injury, for 15/31 (48%) with C5-7 and for only 8/25 (32%) of patients with total injury. Loss of protective sensation or absent sensation was noted in some palmar areas of the hand for 12/105 patients (11%). Normal stereognosis was recorded for 88/105 patients (84%). No significant inequalities in leg length were found and the incidence of structural scoliosis (1.7%) did not differ from that of the reference population. Nearly half of the patients (43%) had asynchronous motion of the upper limbs during gait, which was associated with impaired upper limb function. Data obtained from the completed questionnaires indicated that two thirds (63%) of the patients were satisfied with the functional outcome of the affected hand although one third of all patients needed help with ADL. Only a few patients were unable to participate in physical activities such as: bicycling, cross-country skiing or swimming. However, 71% of the patients reported problems related to the affected upper limb, such as muscle weakness and/or joint stiffness during the aforementioned activities. Incongruity of the radiohumeral joints, extent of the injury, avulsion type injury, age less than three months of age at the time of plexus surgery and inexperience of the surgeon was related to poor results as determined by multivariate analyses. Conclusions: Most of the patients had persistent sequelae, especially of shoulder function. Almost all measurements for the total injury group were poorer compared with those of the C5-6 type injury group. Most of the patients had asymmetry of the shoulder region and a shorter affected upper limb, which is a probable reason for having an abnormal gait. However, BPBP did not have an effect on normal growth of the lower extremities or the spine. Although, participation in physical activities was similar to that of the normal population, two-thirds of the patients reported problems. One-third of the patients needed help with ADL. During the period covered by this study, 7.3% BPBP of patients that needed hospital treatment had a brachial plexus operation, which amounts to fewer than 10 operations per year in Finland. It seems that better results of obstetric plexus surgery and more careful follow-up including opportunities for late reconstructive procedures will be expected, if the treatment is solely concentrated on by a few specialised teams.
Resumo:
This research constructed a readability measurement for French speakers who view English as a second language. It identified the true cognates, which are the similar words from these two languages, as an indicator of the difficulty of an English text for French people. A multilingual lexical resource is used to detect true cognates in text, and Statistical Language Modelling to predict the predict the readability level. The proposed enhanced statistical language model is making a step in the right direction by improving the accuracy of readability predictions for French speakers by up to 10% compared to state of the art approaches. The outcome of this study could accelerate the learning process for French speakers who are studying English. More importantly, this study also benefits the readability estimation research community, presenting an approach and evaluation at sentence level as well as innovating with the use of cognates as a new text feature.
Resumo:
Data assimilation provides an initial atmospheric state, called the analysis, for Numerical Weather Prediction (NWP). This analysis consists of pressure, temperature, wind, and humidity on a three-dimensional NWP model grid. Data assimilation blends meteorological observations with the NWP model in a statistically optimal way. The objective of this thesis is to describe methodological development carried out in order to allow data assimilation of ground-based measurements of the Global Positioning System (GPS) into the High Resolution Limited Area Model (HIRLAM) NWP system. Geodetic processing produces observations of tropospheric delay. These observations can be processed either for vertical columns at each GPS receiver station, or for the individual propagation paths of the microwave signals. These alternative processing methods result in Zenith Total Delay (ZTD) and Slant Delay (SD) observations, respectively. ZTD and SD observations are of use in the analysis of atmospheric humidity. A method is introduced for estimation of the horizontal error covariance of ZTD observations. The method makes use of observation minus model background (OmB) sequences of ZTD and conventional observations. It is demonstrated that the ZTD observation error covariance is relatively large in station separations shorter than 200 km, but non-zero covariances also appear at considerably larger station separations. The relatively low density of radiosonde observing stations limits the ability of the proposed estimation method to resolve the shortest length-scales of error covariance. SD observations are shown to contain a statistically significant signal on the asymmetry of the atmospheric humidity field. However, the asymmetric component of SD is found to be nearly always smaller than the standard deviation of the SD observation error. SD observation modelling is described in detail, and other issues relating to SD data assimilation are also discussed. These include the determination of error statistics, the tuning of observation quality control and allowing the taking into account of local observation error correlation. The experiments made show that the data assimilation system is able to retrieve the asymmetric information content of hypothetical SD observations at a single receiver station. Moreover, the impact of real SD observations on humidity analysis is comparable to that of other observing systems.
Resumo:
The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.
Resumo:
We describe a noniterative method for recovering optical absorption coefficient distribution from the absorbed energy map reconstructed using simulated and noisy boundary pressure measurements. The source reconstruction problem is first solved for the absorbed energy map corresponding to single- and multiple-source illuminations from the side of the imaging plane. It is shown that the absorbed energy map and the absorption coefficient distribution, recovered from the single-source illumination with a large variation in photon flux distribution, have signal-to-noise ratios comparable to those of the reconstructed parameters from a more uniform photon density distribution corresponding to multiple-source illuminations. The absorbed energy map is input as absorption coefficient times photon flux in the time-independent diffusion equation (DE) governing photon transport to recover the photon flux in a single step. The recovered photon flux is used to compute the optical absorption coefficient distribution from the absorbed energy map. In the absence of experimental data, we obtain the boundary measurements through Monte Carlo simulations, and we attempt to address the possible limitations of the DE model in the overall reconstruction procedure.
Resumo:
Radiation therapy (RT) plays currently significant role in curative treatments of several cancers. External beam RT is carried out mostly by using megavoltage beams of linear accelerators. Tumor eradication and normal tissue complications correlate to dose absorbed in tissues. Normally this dependence is steep and it is crucial that actual dose within patient accurately correspond to the planned dose. All factors in a RT procedure contain uncertainties requiring strict quality assurance. From hospital physicist´s point of a view, technical quality control (QC), dose calculations and methods for verification of correct treatment location are the most important subjects. Most important factor in technical QC is the verification that radiation production of an accelerator, called output, is within narrow acceptable limits. The output measurements are carried out according to a locally chosen dosimetric QC program defining measurement time interval and action levels. Dose calculation algorithms need to be configured for the accelerators by using measured beam data. The uncertainty of such data sets limits for best achievable calculation accuracy. All these dosimetric measurements require good experience, are workful, take up resources needed for treatments and are prone to several random and systematic sources of errors. Appropriate verification of treatment location is more important in intensity modulated radiation therapy (IMRT) than in conventional RT. This is due to steep dose gradients produced within or close to healthy tissues locating only a few millimetres from the targeted volume. The thesis was concentrated in investigation of the quality of dosimetric measurements, the efficacy of dosimetric QC programs, the verification of measured beam data and the effect of positional errors on the dose received by the major salivary glands in head and neck IMRT. A method was developed for the estimation of the effect of the use of different dosimetric QC programs on the overall uncertainty of dose. Data were provided to facilitate the choice of a sufficient QC program. The method takes into account local output stability and reproducibility of the dosimetric QC measurements. A method based on the model fitting of the results of the QC measurements was proposed for the estimation of both of these factors. The reduction of random measurement errors and optimization of QC procedure were also investigated. A method and suggestions were presented for these purposes. The accuracy of beam data was evaluated in Finnish RT centres. Sufficient accuracy level was estimated for the beam data. A method based on the use of reference beam data was developed for the QC of beam data. Dosimetric and geometric accuracy requirements were evaluated for head and neck IMRT when function of the major salivary glands is intended to be spared. These criteria are based on the dose response obtained for the glands. Random measurement errors could be reduced enabling lowering of action levels and prolongation of measurement time interval from 1 month to even 6 months simultaneously maintaining dose accuracy. The combined effect of the proposed methods, suggestions and criteria was found to facilitate the avoidance of maximal dose errors of up to even about 8 %. In addition, their use may make the strictest recommended overall dose accuracy level of 3 % (1SD) achievable.
Resumo:
Atmospheric aerosol particles affect the global climate as well as human health. In this thesis, formation of nanometer sized atmospheric aerosol particles and their subsequent growth was observed to occur all around the world. Typical formation rate of 3 nm particles at varied from 0.01 to 10 cm-3s-1. One order of magnitude higher formation rates were detected in urban environment. Highest formation rates up to 105 cm-3s-1 were detected in coastal areas and in industrial pollution plumes. Subsequent growth rates varied from 0.01 to 20 nm h-1. Smallest growth rates were observed in polar areas and the largest in the polluted urban environment. This was probably due to competition between growth by condensation and loss by coagulation. Observed growth rates were used in the calculation of a proxy condensable vapour concentration and its source rate in vastly different environments from pristine Antarctica to polluted India. Estimated concentrations varied only 2 orders of magnitude, but the source rates for the vapours varied up to 4 orders of magnitude. Highest source rates were in New Delhi and lowest were in the Antarctica. Indirect methods were applied to study the growth of freshly formed particles in the atmosphere. Also a newly developed Water Condensation Particle Counter, TSI 3785, was found to be a potential candidate to detect water solubility and thus indirectly composition of atmospheric ultra-fine particles. Based on indirect methods, the relative roles of sulphuric acid, non-volatile material and coagulation were investigated in rural Melpitz, Germany. Condensation of non-volatile material explained 20-40% and sulphuric acid the most of the remaining growth up to a point, when nucleation mode reached 10 to 20 nm in diameter. Coagulation contributed typically less than 5%. Furthermore, hygroscopicity measurements were applied to detect the contribution of water soluble and insoluble components in Athens. During more polluted days, the water soluble components contributed more to the growth. During less anthropogenic influence, non-soluble compounds explained a larger fraction of the growth. In addition, long range transport to a measurement station in Finland in a relatively polluted air mass was found to affect the hygroscopicity of the particles. This aging could have implications to cloud formation far away from the pollution sources.