988 resultados para Real samples
Resumo:
We report the observation of acid-fast Cyclospora cayetanensis oocysts in a sputum sample. The patient, a 60 year-old, HIV negative man, was successfully treated for pulmonary tuberculosis during 1997. On February 1998, he was admitted to our center due to loss of weight, cough with purulent expectoration, dysphonia and a radiological picture of pulmonary fibrosis. Bacilloscopic study of sputum (negative for acid-fast bacilli) stained with Ziehl-Neelsen technique showed large (8-10 µm) spherical, acid-fast Cyclospora cayetanensis oocysts. No other pathogens were isolated on cultures from this sample or from laryngeal biopsy. Serial parasitologic studies showed C. cayetanensis and also eggs of Trichuris trichiura, Ascaris lumbricoides and Hymenolepis nana and of Entamoeba coli cysts. The patient lives in the outskirts of Buenos Aires in a brick-made house with potable water and works as builder of sewers. He travelled in several occasions to the rural area of province of Tucumán which has poor sanitary conditions. C. cayetanensis is an emergent agent of diarrhea and as far as we know this is the first time the parasite is observed in respiratory samples.
Resumo:
The possibility of detecting acute infection and immunity using body fluids that are easier to collect than blood, mainly in children, would facilitate the investigation and follow-up of outbreaks of hepatitis A (HAV). Our study was carried out to evaluate the detection of anti-HAV IgM, IgA and total antibodies in saliva using serum samples as reference. Forty three paired serum and saliva samples were analyzed. From this total, 24 samples were obtained from children and 1 from one adult during the course of acute hepatitis A; an additional 18 samples were obtained from health professionals from Adolfo Lutz Institute. The sensitivity to detect anti-HAV IgM was 100% (95%CI: 79.1 to 100.0%), employing saliva as clinical samples. In detecting anti-HAV IgA, the sensitivity was 80.8% (95%CI: 60.0 to 92.7%) and for the total antibodies was 82.1% (95%CI: 62.4 to 93.2%). The specificity was 100% for each. The rate of agreement was high comparing the results of serum and saliva samples for detecting HAV antibodies. We conclude that saliva is an acceptable alternative specimen for diagnosing acute hepatitis A infection, and for screening individuals to receive hepatitis A vaccine or immunoglobulin.
Resumo:
Os Transformadores de potência são máquinas de elevada importância ao nível dos Sistemas Elétricos de Energia (SEE) uma vez que são estas máquinas que possibilitam a interligação dos diferentes níveis de tensão da rede e a transmissão de energia elétrica em Corrente Alternada (CA). Geralmente, estas máquinas são de grandes dimensões e de elevado nível de complexidade construtiva. Caracterizam-se por possuírem períodos de vida útil bastante elevados (vinte a trinta anos) e preços elevados, o que conduz a um nível de exigência de fiabilidade muito elevada, uma vez que não e viável a existência de muitos equipamentos de reserva nos SEE. Com o objetivo de tentar maximizar o período de vida útil dos transformadores de potência e a sua fiabilidade, tenta-se, cada vez mais, implementar conceitos de manutenção preventiva a este tipo de máquinas. No entanto, a gestão da sua vida útil e extremamente complexa na medida em que, estas máquinas têm vários componentes cruciais e suscetiveis de originar falhas e, quase todos eles, encontram-se no interior de uma cuba. Desta forma, não e possível obter uma imagem do seu estado, em tempo real, sem colocar o transformador fora de serviço, algo que acarreta custos elevados. Por este motivo, desenvolveu-se uma técnica que permite obter uma indicação do estado do transformador, em tempo real, sem o retirar de serviço, colhendo amostras do óleo isolante e procedendo a sua análise físico-química e Analise Gases Dissolvidos (DGA). As análises aos óleos isolantes tem vindo a adquirir uma preponderância muito elevada no diagnóstico de falhas e na analise do estado de conservação destes equipamentos tendo-se desenvolvido regras para interpretação dos parâmetros dos óleos com carácter normativo. Considerando o conhecimento relativo a interpretação dos ensaios físico-químicos e DGA ao oleol, e possível desenvolver ferramentas capazes de otimizar essas mesmas interpretações e aplicar esse conhecimento no sentido de prever a sua evolução, assim como o surgimento de possíveis falhas em transformadores, para assim otimizar os processos de manutenção. Neste campo as Redes Neuronais Artificiais (RNAs) têm um papel fundamental
Resumo:
Serum samples (n: 110) from blood donors and high risk individuals from Cordoba, Argentina with indeterminate HIV-1 and HTLV-I/II Wb profiles were studied for specific antibodies to HTLV-I/II and HIV-1 by indirect immunofluorescence assay (IFA) and for the presence or absence of HIV-1 and HTLV-I/II specific bands by Wb. This study was carried out in order to characterize their putative reactions with HIV-1 and HTLV-I/II proteins and to resolve the retrovirus infection status of these individuals. Results indicated that blood donors sera displaying indeterminate HIV-1 or HTLV-I/II Wb patterns were not immunoreactive to HTLV-I/II and HIV-1 on IFA. However, a high rate of indeterminate HIV-1 and HTLV-I/II Wb samples from high risk individuals had positive HTLV-I/II and HIV-1 IFA results respectively. Our study supports the growing evidence that HTLV-HIV indeterminate seroreactivity in low risk population is due to a cross reaction against nonviral antigens, and in high risk populations the indeterminate samples show serological cross-recognition between HIV-1 proteins and HTLV-I/II proteins on Wb. These results point out the necessity to investigate the HTLV-I/II reactivity in indeterminate HIV-1 samples and viceversa in order to confirm the diagnosis. Finally, this study shows the potential usefulness of IFA in elucidating the status of HIV-1 and HTLV-I/II infection of individuals with indeterminate Wb profiles, thus enabling resolution of retrovirus infection status.
Resumo:
RESUMO: Desenho do estudo: Estudo quantitativo, experimental prospectivo de factor único, desenho pré-teste, pós-teste. Objectivos: Determinar a efectividade da ecografia em tempo real, como Informação de Retorno Extrínseca Visual Ecográfica (IRE-VE) na performance do transverso do abdómen (TrA), em sujeitos saudáveis; analisar eventuais diferenças entre a IRE-VE e a Informação de Retorno Extrínseca Verbal Clínica (IRE-VC); medir a performance da musculatura abdominal, através das diferenças na espessura dos músculos TrA e oblíquo interno (OI) e deslizamento do TrA, em repouso e em contracção. Enquadramento: A maioria dos indivíduos não tem conhecimentos nem consciência do contributo de uma boa performance do TrA para a estabilidade da coluna lombar. Vários estudos recentes se têm dedicado a este assunto, tendo sido mostrado o importante contributo da ecografia como Informação de Retorno Extrínseca (IRE). Uma vez que o TrA e o OI contribuem para a estabilidade lombo pélvica, e que a aprendizagem do seu controlo motor é essencial para a recuperação da função, torna-se relevante clarificar o contributo da informação de retorno na primeira fase da aprendizagem da performance desses músculos, bem como encontrar as melhores estratégias para a sua realização. A ecografia foi o instrumento escolhido para servir esse objectivo. Métodos: Participaram no estudo 75 sujeitos, sem queixas lombares, com idades compreendidas entre os 18 e os 38 anos com um valor médio de 21,9 anos (±4,03), divididos aleatoriamente em três grupos com uma tarefa comum: a “Manobra do Transverso”, em que um grupo não recebeu IRE (GC), outro recebeu IRE verbal clínica e palpatória (GIRE-VC) e ooutro recebeu IRE visual ecográfica (GIRE-VE). Para efeitos de análise da contracção da musculatura abdominal, foram estudadas a espessura dos músculos TrA e OI e o deslizamento do TrA, visualizados em imagens ecográficas em tempo real, e congeladas para medição em diferido. Estes procedimentos foram apurados num estudo piloto de fidedignidade das medições em causa. Quanto à abordagem estatística das variáveis de performance muscular foi realizada uma análise da variância simples paramétrica para amostras independentes e um teste para a diferença de médias para amostras emparelhadas. Resultados: Observamos que no GC, a ausência de IRE cursou com uma performance idêntica nos dois momentos de avaliação e que nos dois grupos com IRE, das variáveis de performance, é significativamente diferente a contracção do TrA, para uma diferença de 1,95 mm no GIRE-VE (p=0,000) e de 0,84 mm no GIRE-VC (p=0,000). Ao comparar os grupos entre si houve diferenças no limiar da significância (p=0,056) para uma melhor contracção do TrA no GIRE-VE. As outras variáveis, contracção do OI e deslizamento do TrA, não revelaram efeito relacionado com a IRE em nenhum dos grupos. Conclusão: Dos resultados obtidos, podemos concluir que a IRE-VE, quando usada isoladamente, na Manobra do Transverso provoca um maior aumento na espessura do TrA, quando comparada com a IRE-VC . O uso da ecografia mostrou ser efectivo na facilitação da performance da Manobra do Transverso em sujeitos saudáveis.---------------------ABSTRACT: Study Design: Single Factor Experimental Design: Pre-Test Post-test Control Group Design. Objectives: To measure the contribution of different types of biofeedack on Transversus Abdominis (TrA) and Internal Oblique (IO) performance through changes in thickness and lateral slide of TrA anterior fascia during abdominal hollowing exercise (AHE). Background: Increasingly clinicians are using real-time ultrasound imaging as a form of supplementing feedback when teaching trunk stabilization exercises to patients; however, there has been no evidence of its effectiveness when used alone. Material and Methods: Seventy-five healthy subjects were divided randomly into 3 groups that received: group 1, no feedback; group 2, verbal and palpatory feedback, and group 3, realtime ultrasound feedback. The TrA and IO performance of each subject was twice assessed (before and after receiving feedback) when performing the AHE in a supine hook-lying position. Analysis of variance and T-test were used for the independent and paired samples, respectively, to determine significant changes in the performance of TrA and IO, based on intra and inter group analysis. Results: Group 1 had no differences between moments; group 2 had significant differences concerning TrA thickness (p=0,000) to a 0,84 mm thickness difference; group 3 had significant differences concerning TrA thickness (p=0,000) to a 1,94 mm difference; The ability to perform the AHE differed only among group 3 and group 1 (p=0.056), and only for changes in thickness of TrA muscle. No differences among groups were found neither for the lateral slide of TrA anterior fascia, nor for the internal oblique thickness. Conclusion: From the results of this study we conclude that real-time ultrasound feedback, when used alone during an AHE, can have a larger increase in TrA thickness when compared to verbal and palpatory feedback. The use of real time ultrasound showed to be effective as a feedback tool to facilitate the performance of the AHE in a supine hook-lying position in healthy subjects.
Resumo:
Animal and human rabies samples isolated between 1989 and 2000 were typified by means of a monoclonal antibody panel against the viral nucleoprotein. The panel had been previously established to study the molecular epidemiology of rabies virus in the Americas. Samples were isolated in the Diagnostic Laboratory of the Pasteur Institute and in other rabies diagnostic centers in Brazil. In addition to the fixed virus samples CVS-31/96-IP, preserved in mouse brain, and PV-BHK/97, preserved in cell culture, a total of 330 rabies virus samples were isolated from dogs, cats, cattle, horses, bats, sheep, goat, swine, foxes, marmosets, coati and humans. Six antigenic variants that were compatible with the pre-established monoclonal antibodies panel were defined: numbers 2 (dog), 3 (Desmodus rotundus), 4 (Tadarida brasiliensis), 5 (vampire bat from Venezuela), 6 (Lasiurus cinereus) and Lab (reacted to all used antibodies). Six unknown profiles, not compatible with the panel, were also found. Samples isolated from insectivore bats showed the greatest variability and the most commonly isolated variant was variant-3 (Desmodus rotundus). These findings may be related to the existence of multiple independent transmission cycles, involving different bat species.
Resumo:
Burkholderia cepacia colonizes cystic fibrosis (CF) patients. We evaluated the impact of the use of a selective medium in the rate of B. cepacia recovery from respiratory samples of CF patients. During a 6-month period, respiratory samples were collected from 106 CF patients and cultivated on selective media including a B. cepacia selective medium. Confirmation of the identity of B. cepacia isolates was carried out by species specific PCR and determination of genomovar status performed by a sequential PCR approach. Results of B. cepacia isolation during this period were compared to the preceding two years, when the sample processing was identical except for the lack of the B. cepacia selective medium. B. cepacia was isolated in 11/257 (4.2%) of the samples using the selective medium, in contrast with the preceding two years, when it was isolated in 6/1029 samples (0.58%), p < 0.0001. Identity of all 11 isolates was confirmed by PCR and genomovar determination was accomplished in all but one isolate. These results suggest that the use of a selective medium increases recovery rate of B. cepacia from respiratory samples.
Resumo:
The occurrence of human Toxocara infection was evaluated in three neighborhoods of the periphery of the Campinas municipality (Jardim Santa Mônica, Jardim São Marcos and Jardim Campineiro) in 1999. Forty residences and 138 residents were randomly selected by drawing lots and were submitted to a seroepidemiological survey, which included blood collection for the immunoenzymatic detection (ELISA) of anti-Toxocara antibodies and a blood count, and the application of a semi-structured questionnaire for the evaluation of epidemiological data. Significant levels of anti-Toxocara antibodies were detected in 23.9% of the 1999 samples. No significant difference in the frequency of infection according to age was observed. Environmental contamination with Toxocara eggs was observed in 12.3 and 14.0% of 57 soil samples collected in the same region in December 1998 and July 1999, respectively. Univariate analysis and multiple logistic regression of the data obtained from the questionnaires and of the results of the serological tests, suggest a significant influence of socioeconomic variables on the frequency of human infection with Toxocara under the conditions prevalent in the study area.
Resumo:
Laboratory investigation of botulism from 1982 to 2001 confirmed the occurrence of eight positive outbreaks/cases of botulism in Brazil. From those, type A botulism was observed in seven of them. Biological material of one case (serum and feces) was positive in the first step of the bioassay, but the amount of sample was not sufficient for typification. One of the outbreaks that occurred in 2001 was negative for botulinum toxin in samples of serum, gastric washing and feces, collected eight days before the onset of the symptoms in the affected person who was clinically diagnosed as presenting the disease. Other two cases presenting compatible clinical diagnoses presented negative results. However, in those cases, the collection of samples was (1) after antiserum administration or (2) later than eight days of the onset of symptoms. Investigation was performed by mouse bioassay, as described in the Compendium of Methods for the Microbiological Examination of Foods (compiled by American Public Health Association - APHA)11, using specific antiserum from Centers for Disease Control (CDC), USA.
Resumo:
272 isolates of Salmonella Enteritidis (111 isolated from frozen broiler chicken carcasses, 126 from human food and other biological materials involved in food poisoning outbreaks and 35 from different poultry materials) were selected for phage typing. From these, 111 were phage typed, 57.65% being classified as phage type 4, 32.43% as phage type 4a, 3.60% as phage type 6a and 0.90% as phage type 7, whereas 5.40% samples were not phage typeable. The predominance of phage type 4 is in agreement with the results published worldwide, and reinforces the need for studies related to the epidemiological meaning of these findings.
Resumo:
An ever increasing need for extra functionality in a single embedded system demands for extra Input/Output (I/O) devices, which are usually connected externally and are expensive in terms of energy consumption. To reduce their energy consumption, these devices are equipped with power saving mechanisms. While I/O device scheduling for real-time (RT) systems with such power saving features has been studied in the past, the use of energy resources by these scheduling algorithms may be improved. Technology enhancements in the semiconductor industry have allowed the hardware vendors to reduce the device transition and energy overheads. The decrease in overhead of sleep transitions has opened new opportunities to further reduce the device energy consumption. In this research effort, we propose an intra-task device scheduling algorithm for real-time systems that wakes up a device on demand and reduces its active time while ensuring system schedulability. This intra-task device scheduling algorithm is extended for devices with multiple sleep states to further minimise the overall device energy consumption of the system. The proposed algorithms have less complexity when compared to the conservative inter-task device scheduling algorithms. The system model used relaxes some of the assumptions commonly made in the state-of-the-art that restrict their practical relevance. Apart from the aforementioned advantages, the proposed algorithms are shown to demonstrate the substantial energy savings.
Resumo:
Many-core platforms are an emerging technology in the real-time embedded domain. These devices offer various options for power savings, cost reductions and contribute to the overall system flexibility, however, issues such as unpredictability, scalability and analysis pessimism are serious challenges to their integration into the aforementioned area. The focus of this work is on many-core platforms using a limited migrative model (LMM). LMM is an approach based on the fundamental concepts of the multi-kernel paradigm, which is a promising step towards scalable and predictable many-cores. In this work, we formulate the problem of real-time application mapping on a many-core platform using LMM, and propose a three-stage method to solve it. An extended version of the existing analysis is used to assure that derived mappings (i) guarantee the fulfilment of timing constraints posed on worst-case communication delays of individual applications, and (ii) provide an environment to perform load balancing for e.g. energy/thermal management, fault tolerance and/or performance reasons.
Resumo:
Over the past decades several approaches for schedulability analysis have been proposed for both uni-processor and multi-processor real-time systems. Although different techniques are employed, very little has been put forward in using formal specifications, with the consequent possibility for mis-interpretations or ambiguities in the problem statement. Using a logic based approach to schedulability analysis in the design of hard real-time systems eases the synthesis of correct-by-construction procedures for both static and dynamic verification processes. In this paper we propose a novel approach to schedulability analysis based on a timed temporal logic with time durations. Our approach subsumes classical methods for uni-processor scheduling analysis over compositional resource models by providing the developer with counter-examples, and by ruling out schedules that cause unsafe violations on the system. We also provide an example showing the effectiveness of our proposal.
Resumo:
Accepted in 13th IEEE Symposium on Embedded Systems for Real-Time Multimedia (ESTIMedia 2015), Amsterdam, Netherlands.
Resumo:
As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.