974 resultados para Rangel curve


Relevância:

10.00% 10.00%

Publicador:

Resumo:

25th Annual Conference of the European Cetacean Society, Cadiz, Spain 21-23 March 2011.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mucin-16 (MUC16) is the established ovarian cancer marker used to follow the disease during or after treatment for epithelial ovarian cancer. The emerging science of cancer markers also demands for the new sensitive detection methods. In this work, we have developed an electrochemical immunosensor for antigen MUC16 using gold nanoelectrode ensemble (GNEE) and ferrocene carboxylic acid encapsulated liposomes tethered with monoclonal anti-Mucin-16 antibodies ( MUC16). GNEEs were fabricated by electroless deposition of the gold within the pores of polycarbonate track-etched membranes. Afterwards, MUC16 were immobilized on preformed self-assembled monolayer of cysteamine on the GNEE via cross-linking with EDC-Sulfo-NHS. A sandwich immunoassay was performed on MUC16 functionalized GNEE with MUC16 and immunoliposomes. The differential pulse voltammetry was employed to quantify the faradic redox response of ferrocene carboxylic acid released from immunoliposomes. The dose–response curve for MUC16 concentration was found between the range of 0.001–300 U mL−1. The lowest detection limit was found to be 5 × 10−4 U mL−1 (S/N = 3). We evaluated the performance of this developed immunosensor with commercial ELISA assay by comparing results obtained from spiked serum samples and real blood serum samples from volunteers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam algorithm and Gafchromic EBT2 films. A home-PMMA phantom with the same geometry as the simulated one was specifically constructed for the measurements. Our results indicate that the presence of the cavity causes an increase (up to 70%) of the dose maximum value as well as a shift forward of the position of the depthedose curve, compared to the homogeneous one. Pronounced dose discontinuities in the regions close to the lateral cavity edges are observed. The shape and magnitude of these discontinuities change with the dimension of the cavity. It is also found that the cavity effect is more pronounced (6%) for the 12 MeV electron beam and the presence of cavities with large thickness and small area introduces more significant variations (up to 70%) on the depthedose curves. Overall, the Gafchromic EBT2 film measurements were found in agreement within 3% with Monte Carlo calculations and predict well the fine details of the dosimetric change near the cavity interface. The Pencil Beam calculations underestimate the dose up to 40% compared to Monte Carlo simulations; in particular for the largest cavity thickness (2.8 cm).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Following work on tantalum and chromium implanted flat M50 steel substrates, this work reports on the electrochemical behaviour of M50 steel implanted with tantalum and chromium and the effect of the angle of incidence. Proposed optimum doses for resistance to chloride attack were based on the interpretation of results obtained during long-term and accelerated electrochemical testing. After dose optimization from the corrosion viewpoint, substrates were implanted at different angles of incidence (15°, 30°, 45°, 60°, 75°, 90°) and their susceptibility to localized corrosion assessed using open-circuit measurements, step by step polarization and cyclic voltammetry at several scan rates (5–50 mV s-1). Results showed, for tantalum implanted samples, an ennoblement of the pitting potential of approximately 0.5 V for an angle of incidence of 90°. A retained dose of 5 × 1016 atoms cm-2 was found by depth profiling with Rutherford backscattering spectrometry. The retained dose decreases rapidly with angle of incidence. The breakdown potential varies roughly linearly with the angle of incidence up to 30° falling fast to reach -0.1 V (vs. a saturated calomel electrode (SCE)) for 15°. Chromium was found to behave differently. Maximum corrosion resistance was found for angles of 45°–60° according to current densities and breakdown potentials. Cr+ depth profiles ((p,γ) resonance broadening method), showed that retained doses up to an angle of 60° did not change much from the implanted dose at 90°, 2 × 1017 Cr atoms cm-2. The retained implantation dose for tantalum and chromium was found to follow a (cos θ)8/3 dependence where θ is the angle between the sample normal and the beam direction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deste "Primeiro Acto" fazem parte algumas das músicas que fui compondo para peças de teatro ao longo de vários anos. Como é evidente, a música de cena coexiste com a imagem e representação teatral e a elas está ligada duma forma inseparável. Contudo, pretendo que algumas das músicas possam ter autonomia suficiente para se apresentarem sozinhas como peças musicais independentes. Tal foi o propósito deste disco. A escolha dos trechos de música obedeceu a um critério musical e dramático que vagamente jogasse com dois mundos: a cidade e o circo. Passados cinco anos do lançamento do CD fui convidado pela Direcção do Festival Internacional de Teatro de Expressão Ibérica – FITEI para conceber e realizar um espectáculo, para o FITEI – 2005, com músicas e canções que fui fazendo para teatro ao longo dos anos. Servindo-me como base das músicas deste CD, juntando outras, e escrevendo um guião cénico de ligação das várias músicas, com novos arranjos instrumentais, juntaram-se dez músicos, quatro cantores e quatro bailarinos para realizar esse espectáculo que, além da sua estreia em 2005 no Teatro Rivoli, no Porto, foi apresentado também nas comemorações do Dia Mundial de Teatro de 2006 no Teatro Nacional D. Maria II. Os trechos musicais escolhidos fizeram parte dos seguintes espectáculos: "Hoje começa o Circo" de João Lóio, encenado por João Mota, pelo Grupo de Teatro Roda Viva, Porto,1978; "Mais um Dia", espectáculo musical de João Lóio, Porto,1987; "Dança de Roda" de Arthur Schnitzler, encenado por João Paulo Costa, pelo Grupo de Teatro " Os Comediantes", Porto, 1990; "Um certo Plume" de Henri Michaux, encenado por Adriano Luz no Teatro da Cornucópia, Lisboa, 1993; "Aurélio da Paz dos Reis", filme realizado por Manuel Faria de Almeida, Lisboa, 1995; "Edmond" de David Mamet, encenado por Adriano Luz no Teatro Nacional D. Maria II, Lisboa, 1996; "A pandilha" de Cândido Ferreira, encenado por Cândido Ferreira, pelo Teatro Experimental do Porto, Porto, 1996 (No final deste texto dá-se informação pormenorizada sobre as peças e filme dos quais estes trechos musicais fizeram parte).Gravado em Junho, Julho e Setembro de 2000, este CD tem a seguinte ficha técnica: Direccção Musical e Produção: João Lóio; Gravação: Fernando Rangel; Mistura: Fernando Rangel e João Lóio; Masterização: Fernando Rangel; Estúdio de Gravação: Fortes & Rangel, Porto; Desenho Gráfico: José Tavares; Fotografias: Jorge Gigante e José Tavares. O “PRIMEIRO ACTO” contou com a participação dos seguintes músicos: Flauta: Jorge Salgado; Saxofone Soprano: Fernanda Alves; Saxofone Alto: Rosa Oliveira; Saxofone Tenor: Mário Santos; Isabel Anjo; Saxofone Barítono: Mário Brito; Trompa: Bohdan Sebestick; Trombone: Vítor Faria; Tuba: Manuel Costa; Harpa : Ana Paula Miranda ; Acordeão: Arnaldo Fonseca ; Guitarras: Carlos Rocha; Baixo Acústico: Firmino Neiva; Piano: Carlos Azevedo; Helena Marinho; Paulino Garcia; Violinos: David Lloyd; Richard Tomes; Suzanna Lidegran; Viola: David Lloyd; Violoncelo: Miranda T. Adams; Contrabaixo: António Augusto Aguiar; Sintetizador: João Lóio ; Percussão : Mário Teixeira; Coro: Guilhermino Monteiro, Jorge Prendas, Rui Vilhena.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em hidráulica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To develop a Charlson-like comorbidity index based on clinical conditions and weights of the original Charlson comorbidity index. METHODS: Clinical conditions and weights were adapted from the International Classification of Diseases, 10th revision and applied to a single hospital admission diagnosis. The study included 3,733 patients over 18 years of age who were admitted to a public general hospital in the city of Rio de Janeiro, southeast Brazil, between Jan 2001 and Jan 2003. The index distribution was analyzed by gender, type of admission, blood transfusion, intensive care unit admission, age and length of hospital stay. Two logistic regression models were developed to predict in-hospital mortality including: a) the aforementioned variables and the risk-adjustment index (full model); and b) the risk-adjustment index and patient's age (reduced model). RESULTS: Of all patients analyzed, 22.3% had risk scores >1, and their mortality rate was 4.5% (66.0% of them had scores >1). Except for gender and type of admission, all variables were retained in the logistic regression. The models including the developed risk index had an area under the receiver operating characteristic curve of 0.86 (full model), and 0.76 (reduced model). Each unit increase in the risk score was associated with nearly 50% increase in the odds of in-hospital death. CONCLUSIONS: The risk index developed was able to effectively discriminate the odds of in-hospital death which can be useful when limited information is available from hospital databases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No trabalho realizado nesta tese, procedeu-se ao estudo hidrodinâmico de uma coluna de borbulhamento de recirculação externa do líquido (CREL), que permitiu ampliar o conhecimento já existente sobre este tipo de colunas. Para realizar este estudo utilizaram-se líquidos viscosos Newtonianos, nomeadamente soluções aquosas de glicerina com viscosidades entre 0,007 e 0,522 Pa.s. Para a gama de caudais de ar injectados, 1,5x10-5 até 1,35x10-4 m3/s, o ar ascendia ao longo da coluna de borbulhamento sob a forma de bolhas tubulares. Após a realização dos ensaios, verificou-se que o regime de escoamento do líquido entre bolhas tubulares variou desde o tipo laminar até transição (1,9 Rangel (2008)) de forma a poder analisar a influência da razão de submersão sobre os parâmetros hidrodinâmicos. Nos ensaios realizados foram determinadas a retenção do gás na coluna e a velocidade superficial do líquido em escoamento no interior da coluna de borbulhamento. Os valores da retenção do gás foram comparados com valores teóricos previstos por equações empíricas de Nicklin et al (1962). Estes valores também foram comparados com valores obtidos experimentalmente em trabalhos anteriores, onde se utilizaram razões de submersão de 0,935 e 0,91. Após análise dos valores da retenção verificou-se que estes eram mais elevados para as soluções de maior viscosidade e menor diâmetro da coluna. Para as experiências realizadas com as soluções com viscosidades entre 0,52 Pa.s e 0,053 Pa.s, os valores experimentais eram inferiores aos previstos por Nicklin et al (1962) para regime laminar tanto na coluna de 22 mm como na coluna de 32 mm. Para a solução com 0,007 Pa.s de viscosidade os valores experimentais situavam-se na zona de transição entre o regime laminar e o regime turbulento em ambas as colunas. Verificou-se que a diminuição da razão de submersão de 0,935 para 0,85 aumentou significativamente a retenção em todas as experiências realizadas. A velocidade superficial média de circulação do líquido variava na razão inversa do diâmetro e da viscosidade. A diminuição da retenção provocou uma diminuição significativa na velocidade do líquido.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A verificação das Características Garantidas associadas aos equipamentos, em especial dos aerogeradores, incluídos no fornecimento de Parques Eólicos, reveste-se de particular importância devido, principalmente, ao grande volume de investimento em jogo, ao longo período necessário ao retorno do mesmo, à incerteza quanto à manutenção futura das actuais condições de remuneração da energia eléctrica produzida e ainda à falta de dados históricos sobre o período de vida útil esperado para os aerogeradores. Em face do exposto, é usual serem exigidas aos fornecedores, garantias do bom desempenho dos equipamentos, associadas a eventuais penalidades, quer para o período de garantia, quer para o restante período de vida útil, de modo a minimizar o risco associado ao investimento. No fornecimento de Parques Eólicos existem usualmente três tipos de garantias, nomeadamente, garantia de Curva de Potência dos aerogeradores, garantia de Disponibilidade dos equipamentos ou garantia de Produção de Energia. Estas poderão existir isoladamente ou em combinação, dependendo das condições contratuais acordadas entre o Adjudicatário e o Fornecedor. O grau de complexidade e/ou trabalho na implementação das mesmas é variável, não sendo possível afirmar qual delas é a mais conveniente para o Adjudicatário, nem qual a mais exacta em termos de resultados. Estas dúvidas surgem em consequência das dificuldades inerentes à recolha dos próprios dados e também da relativamente ampla margem de rearranjo dos resultados permitido pelas normas existentes, possibilitando a introdução de certo tipo de manipulações nos dados (rejeições e correlações), as quais podem afectar de forma considerável as incertezas dos resultados finais dos ensaios. Este trabalho, consistiu no desenvolvimento, execução, ensaio e implementação de uma ferramenta informática capaz de detectar de uma forma simples e expedita eventuais desvios à capacidade de produção esperada para os aerogeradores, em função do recurso verificado num dado período. Pretende ser uma ferramenta manuseável por qualquer operador de supervisão, com utilização para efeitos de reparações e correcção de defeitos, não constituindo contudo uma alternativa a outros processos abrangidos por normas, no caso de aplicação de penalidades. Para o seu funcionamento, são utilizados os dados mensais recolhidos pela torre meteorológica permanente instalada no parque e os dados de funcionamento dos aerogeradores, recolhidos pelo sistema SCADA. Estes são recolhidos remotamente sob a forma de tabelas e colocados numa directoria própria, na qual serão posteriormente lidos pela ferramenta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the best cut-offs of body mass index for identifying alterations of blood lipids and glucose in adolescents. METHODS: A probabilistic sample including 577 adolescent students aged 12-19 years in 2003 (210 males and 367 females) from state public schools in the city of Niterói, Southeastern Brazil, was studied. The Receiver Operating Characteristic curve was used to identify the best age-adjusted BMI cut-off for predicting high levels of serum total cholesterol (>150mg/dL), LDL-C (>100mg/dL), serum triglycerides (>100mg/dL), plasma glucose (>100mg/dL) and low levels of HDL-C (< 45mg/dL). Four references were used to calculate sensitivity and specificity of BMI cut-offs: one Brazilian, one international and two American. RESULTS: The most prevalent metabolic alterations (>50%) were: high total cholesterol and low HDL-C. BMI predicted high levels of triglycerides in males, high LDL-C in females, and high total cholesterol and the occurrence of three or more metabolic alterations in both males and females (areas under the curve range: 0.59 to 0.67), with low sensitivity (57%-66%) and low specificity (58%-66%). The best BMI cut-offs for this sample (20.3 kg/m² to 21.0 kg/m²) were lower than those proposed in the references studied. CONCLUSIONS: Although BMI values lower than the International cut-offs were better predictor of some metabolic abnormalities in Brazilian adolescents, overall BMI is not a good predictor of these abnormalities in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the basic reproduction number (R0) of dengue fever including both imported and autochthonous cases. METHODS: The study was conducted based on epidemiological data of the 2003 dengue epidemic in Brasília, Brazil. The basic reproduction number is estimated from the epidemic curve, fitting linearly the increase of initial cases. Aiming at simulating an epidemic with both autochthonous and imported cases, a "susceptible-infectious-resistant" compartmental model was designed, in which the imported cases were considered as an external forcing. The ratio between R0 of imported versus autochthonous cases was used as an estimator of real R0. RESULTS: The comparison of both reproduction numbers (only autochthonous versus all cases) showed that considering all cases as autochthonous yielded a R0 above one, although the real R0 was below one. The same results were seen when the method was applied on simulated epidemics with fixed R0. This method was also compared to some previous proposed methods by other authors and showed that the latter underestimated R0 values. CONCLUSIONS: It was shown that the inclusion of both imported and autochthonous cases is crucial for the modeling of the epidemic dynamics, and thus provides critical information for decision makers in charge of prevention and control of this disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes