916 resultados para Quantitative Angaben


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most of the problems of endodontic origin have a bacterial etiological agent. Thus, there is a continued interest in seeking more effective chemical substances that can replace the camphorated paramonochiorophenol or antibiotics as intracanal medicaments. Among the possible substances, ozone has some interesting biological characteristics: bactericidal action, debriding effect, angiogenesis stimulation capacity and high oxidizing power. The purpose of this study was to chemically evaluate the presence of ozone in sunflower, castor, olive and almond oil, as well as in propylene glycol and byproducts of ozonation, such as formaldehyde. These compounds were ozonized, inserted into empty and sterile vials, and analyzed by testing the reaction between ozone and indigo, for determining the presence of ozone, and subjected to the chromotropic acid test for determining the presence of formaldehyde. It was observed complete absence of ozone in all samples tested and presence of formaldehyde. The bactericidal and healing action of ozonized oils could be attributed to products formed by the ozonation of mineral oils, such as formaldehyde, not to the ozone itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. One of the concerns of Sports Sciences is the search for methodologies that can help discover potential athletes. In this sense, some initiatives have been taken in an attempt to identify and characterize the genetic profile of dermatoglyphic marks (fingerprints). The present work has the objective of understanding the distribution of quantitative dermatoglyphic indicators in basketball players with different levels of performance compared to non-players. Methods. The subjects observed constituted 125 individuals, divided into five numerically equal groups, three of which were composed of professional basketball players according to their level of participation (Brazilian Team, National Championship and São Paulo Championship) and the last two formed by weekend players and non-players, respectively. Eleven dermatoglyphic variables were analysed in the descriptive level by means of measurement of position, variability and limits of confidence of the median, and, in inferential terms, the Kruskal-Wallis statistical test was adopted. Results. The more expressive ones were: TRC, counting lines a-b and A'-d, behave differently between athletes and non-athletes. Conclusion. Studies about this kind of analysis should be continued, calling on resources that take into consideration all variables simultaneously as a multivariate study. © 2012 Revista Andaluza de Medicina del Deporte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correlative fractography is a new expression proposed here to describe a new method for the association between scanning electron microscopy (SEM) and light microscopy (LM) for the qualitative and quantitative analysis of fracture surfaces. This article presents a new method involving the fusion of one elevation map obtained by extended depth from focus reconstruction from LM with exactly the same area by SEM and associated techniques, as X-ray mapping. The true topographic information is perfectly associated to local fracture mechanisms with this new technique, presented here as an alternative to stereo-pair reconstruction for the investigation of fractured components. The great advantage of this technique resides in the possibility of combining any imaging methods associated with LM and SEM for the same observed field from fracture surface. © Microscopy Society of America 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The methodology for fracture analysis of polymeric composites with scanning electron microscopes (SEM) is still under discussion. Many authors prefer to use sputter coating with a conductive material instead of applying low-voltage (LV) or variable-pressure (VP) methods, which preserves the original surfaces. The present work examines the effects of sputter coating with 25 nm of gold on the topography of carbon-epoxy composites fracture surfaces, using an atomic force microscope. Also, the influence of SEM imaging parameters on fractal measurements is evaluated for the VP-SEM and LV-SEM methods. It was observed that topographic measurements were not significantly affected by the gold coating at tested scale. Moreover, changes on SEM setup leads to nonlinear outcome on texture parameters, such as fractal dimension and entropy values. For VP-SEM or LV-SEM, fractal dimension and entropy values did not present any evident relation with image quality parameters, but the resolution must be optimized with imaging setup, accompanied by charge neutralization. © Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative variations in heterotrophic plate count (HPC) and in the presence of indicator microorganisms in 0.5, 1.5 and 20-L bottles of different brands of Brazilian mineral water were analyzed during their shelf life. No variations were identified in the presence of indicator microorganisms, but quantitative variations in HPC were observed in some brands, which suggests that changes may be occurring in the water quality during storage. The aim of this study was also to evaluate the quality of the bottled mineral waters and the presence of enterococci and Pseudomonas aeruginosa were verified in six and two bottles, respectively, which is in disagreement with the microbiological quality criteria established in the current legislation. Although no limit is set for HPC in mineral water, this study relies on the limit of 500 colony-forming units per mL of sample (CFU/mL). Seventy-two bottles presented levels above 500 CFU/mL and up to 560,000 CFU/mL. This study showed that the control of HPC (<500 CFU/mL) for non-returnable packaging seems to be adequate to ensure the quality of mineral water during storage. The high values of HPC and its variations detected during storage seem to fully justify the need for a reevaluation of the use of HPC in bottled mineral water quality management. More detailed studies on the potential health risk of HPC and its variations in mineral water are also needed. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the relationships between gross chemical composition and ultrasonographic characteristics of the ram testes. Ten testes from sexually mature Karakul rams were scanned ex situ with an 8-MHz linear-array transducer, in a transverse and longitudinal plane. All ultrasonograms were saved as digital images and subjected to computerized analyses. Crude protein content was determined by the Kjeldahl method, moisture was determined with an oven-drying method, and fat was measured by the Soxhlet extraction of dried samples. Mean pixel values (r = -0.64, P = 0.04), pixel heterogeneity (standard deviation of pixel values; r = -0.64, P = 0.04) and maximum pixel intensity (r = -0.76, P = 0.01) were all negatively correlated with parenchymal protein content. Pixel heterogeneity correlated directly with extractable lipids (r = 0.66, P = 0.02). The quantitative correlations between echotextural and biochemical parameters found in the present experiment confirm the utility of ultrasonographic imaging combined with computer-assisted image analysis for determining changes in testicular histophysiology. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: The present work uses multivariate statistical analysis as a form of establishing the main sources of error in the Quantitative Phase Analysis (QPA) using the Rietveld method. The quantitative determination of crystalline phases using x ray powder diffraction is a complex measurement process whose results are influenced by several factors. Ternary mixtures of Al2O3, MgO and NiO were prepared under controlled conditions and the diffractions were obtained using the Bragg-Brentano geometric arrangement. It was possible to establish four sources of critical variations: the experimental absorption and the scale factor of NiO, which is the phase with the greatest linear absorption coefficient of the ternary mixture; the instrumental characteristics represented by mechanical errors of the goniometer and sample displacement; the other two phases (Al2O3 and MgO); and the temperature and relative humidity of the air in the laboratory. The error sources excessively impair the QPA with the Rietveld method. Therefore it becomes necessary to control them during the measurement procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudos biológicos são necessários para o manejo da vida silvestre em cativeiro, e o conhecimento da reprodução é um dos aspectos importantes para o aumento da produção. Esta pesquisa teve como objetivo determinar a idade da puberdade do cateto macho. Foram utilizadas amostras testiculares de 15 animais, entre 7 a 16 meses, distribuídos em cinco grupos (G1, G2, G3, G4 e G5). Os testículos aumentaram no peso, comprimento e largura consideravelmente (p < 0,05) do G1 ao G3, enquanto que, a partir deste grupo, o desenvolvimento desse órgão foi mais lento. Houve correlação positiva (p < 0,001) entre os seguintes parâmetros testiculares: peso e comprimento (r = 0,97), peso e largura (r = 0,88), comprimento e largura (r = 0,92). Com relação ao diâmetro tubular, observou-se um aumento (p < 0,05) do G1 ao G4. A quantidade total de células espermatogênicas aumentou significativamente (p < 0,05) até o G3, e se estabilizou a partir deste grupo. Houve correlação positiva entre o peso testicular e o diâmetro tubular (r = 0,99, p < 0,001), bem como o peso testicular e as células espermatogênicas (r = 0,98, p < 0,001). A quantidade de células de Sertoli reduziu significativamente (p < 0,05) do G1, onde se encontravam indiferenciadas como células de suporte, até G5, onde foram observadas juntamente com todas as células da linhagem espermática. Estes resultados demonstraram que as fases do desenvolvimento reprodutivo de catetos podem ser classificadas em: impúbere (G1, 7-8 meses), pré-púbere (G2, 9-10 meses), púbere (G3, 11-12 meses), pós-púbere 1 (G4, 13-14 meses) e pós-púbere 2 (G5, 15-16 meses). Com base na análise histológica, a puberdade dos catetos machos ocorre entre 11 e 12 meses de idade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiquantitative (Maki) and quantitative (Brun- Buisson) culture techniques were employed in the diagnosis of catheter-related bloodstream infections (CRBSI) in patients who have a short-term central venous catheter (inserted for 30 days). The diagnosis of CRBSI was based on the results of semiquantitative and quantitative culture of material from the removed catheters. Catheter tips (118) from 100 patients were evaluated by both methods. Semiquantitative analysis revealed 34 catheters (28.8%) colonized by ≥15 colonyforming units (cfu), while quantitative cultures (34 catheters, 28.8%) showed the growth of ≥103 cfu/mL. Bacteremia was confirmed in four patients by isolating microorganisms of identical species from both catheters and blood samples. Using the semiquantitative culture technique on short-term central venous catheter tips, we have shown that with a cut-off level of ≥15 cfu, the technique had 100.0% sensitivity, specificity of 68.4%, 25.0% positive predictive value (PPV) and 100.0% negative predictive value (NPV), efficiency of 71.4% and a prevalence of 9.5%. The quantitative method, with a cut-off limit of ≥103 cfu/mL, gave identical values: the sensitivity was 100.0%, specificity 68.4%, positive predictive value (PPV) 25.0%, negative predictive value (NPV) 100.0%, efficiency 71.4% and prevalence 9.5%. We concluded that the semiquantitative and quantitative culture methods, evaluated in parallel, for the first time in Brazil, have similar sensitivity and specificity. Keywords: central venous catheter; semi-quantitative culture; quantitative culture; catheter-related bacteremia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos Investigar o uso do EEG quantitativo (qEEG) em pacientes com encefalopatias agudas (EAs ) e anormalidades da atividade de base no EEG. Método s pacientes foram divididos em prognóstico favorável (grupo A, 43 pacientes) e desfavorável (grupo B, 5 pacientes). O programa EEGLAB foi utilizado para a análise do qEEG. Um gráfico da potência espectral de todos os canais foi gerado para cada participante. Os dois grupos foram comparados estatisticamente. Resultados No grupo A, a análise espectral revelou picos (frequências teta e alfa) em 84% (38/45) dos pacientes. No grupo B, um pico espectral na frequência delta foi detectado em um paciente. Os pacientes remanescentes dos dois grupos não apresentaram picos espectrais. A análise estatística mostrou menores frequências registradas nos eletrodos posteriores dos pacientes do grupo B. Conclusão O qEEG pode ser útil na avaliação de pacientes com EAs auxiliando na determinação do prognóstico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)