871 resultados para Pulsating heat pipe
Resumo:
Background: the purpose this study was to investigate the relationship of anti-myosin and anti-heat shock protein immunoglobulin G (IgG) serum antibodies to the original heart disease of cardiac transplant recipients, and also to rejection and patient survival after cardiac transplantation.Methods: Anti-myosin and anti-heat shock protein (anti-hsp) IgG antibodies were evaluated in pre-transplant sera from 41 adult cardiac allograft recipients and in sequential post-transplant serum samples from 11 recipients, collected at the time of routine endomyocardial biopsies during the first 6 months after transplantation. In addition, the levels of these antibodies were determined from the sera of 28 healthy blood donors.Results: Higher anti-myosin antibody levels were observed in pre-transplant sera than in sera from normal controls. Moreover, patients with chronic Chagas heart disease showed higher anti-myosin levels than patients with ischemic heart disease, and also higher levels, although not statistically significant, than patients with dilated cardiomyopathy. Higher anti-hsp levels were also observed in patients compared with healthy controls, but no significant differences were detected among,the different types of heart diseases. Higher pre-transplant anti-myosin, but not anti-hsp, levels were associated with lower 2-year post-transplant survival. In the post-transplant period, higher anti-myosin IgG levels were detected in sera collected during acute rejection than in sera collected during the rejection-free period, whereas anti-hsp IgG levels showed no difference between these periods.Conclusions: the present findings are of interest for post-transplant management and, in addition, suggest a pathogenic role for anti-myosin antibodies in cardiac transplant rejection, as has been proposed in experimental models of cardiac transplantation.
Resumo:
Calcium copper titanate (CaCu3Ti4O12) ceramic varistors were prepared by solid-state method. The samples were several times heat treated in vacuum and the evolution of electrical characteristics were monitored by current density versus electric field measurements and impedance spectroscopy. Repeated heat treatments in vacuum (900 degrees C for 1 h, 0.01 Torr) lead to a desorption of oxygen adsorbed at the grain boundaries and consequently to a degradation of the varistor properties. During further successive heat treatments some oxygen from the grain interior moves to the grain boundary thereby partially restoring the varistor properties. (c) 2006 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Resumo:
The culture supernatant of Escherichia coli, isolated from ostriches with diarrhea in Brazil, caused elongation in Vero cell, rounding in Chinese hamster ovary (CHO) cells and a cytoplasmic vacuolation in ostrich embryo fibroblasts (OEF), but it was not cytotoxic for chicken embryo fibroblasts (CEF). These effects were not neutralized by antiserum to cholera toxin. Polymerase chain reaction assays showed that the ostrich E.coli contained the gene encoding (eltII-A), but not those for type 1 heat-labile enterotoxin (eltA), heat-stable enterotoxins (estA, estB), verocytotoxins (stx-I, stx-II), or cytotoxic necrotizing factors (cnf 1, cnf 2). All isolates belonged to serotype O15:H8. The enteropathogenic relevance of LT-II in ostrich diarrhea remains undetermined. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
In order to develop statistical models to predict respiratory heat loss in dairy cattle using simple physiological and environmental measurements, 15 Holstein cows were observed under field conditions in a tropical environment, in which the air temperature reached up to 40 ° C. The measurements of latent and sensible heat loss from the respiratory tract of the animals were made by using a respiratory mask. The results showed that under air temperatures between 10 and 35 ° C sensible heat loss by convection decreased from 8.24 to 1.09 W m(-2), while the latent heat loss by evaporation increased from 1.03 to 56.51 W m(-2). The evaporation increased together with the air temperature in almost a linear fashion until 20 ° C, but it became increasingly high as the air temperature rose above 25 ° C. Convection was a mechanism of minor importance for respiratory heat transfer. In contrast, respiratory evaporation was an effective means of thermoregulation for Holsteins in a hot environment. Mathematical models were developed to predict both the sensible and latent heat loss from the respiratory tract in Holstein cows under field conditions, based on measurements of the ambient temperature, and other models were developed to predict respiration rate, tidal volume, mass flow rate and expired air temperature as functions of the ambient temperature and other variables.
Resumo:
The purpose of this study was to evaluate the effect of different heat-treatment strategies for a ceramic primer on the shear bond strength of a 10-methacryloyloxydecyl-dihydrogen-phosphate (MDP)-based resin cement to a yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic. Specimens measuring 4.5 x 3.5 x 4.5 mm(3) were produced from Y-TZP presintered cubes and embedded in polymethyl methacrylate (PMMA). Following finishing, the specimens were cleaned using an ultrasound device and distilled water and randomly divided into 10 experimental groups (n=14) according to the heat treatment of the ceramic primer and aging condition. The strategies used for the experimental groups were: GC (control), without primer; G20, primer application at ambient temperature (20 degrees C); G45, primer application + heat treatment at 45 degrees C; G79, primer application + heat treatment at 79 degrees C; and G100, primer application + heat treatment at 100 degrees C. The specimens from the aging groups were submitted to thermal cycling (6000 cycles, 5 degrees C/55 degrees C, 30 seconds per bath) after 24 hours. A cylinder of MDP-based resin cement (2.4 mm in diameter) was constructed on the ceramic surface of the specimens of each experimental group and stored for 24 hours at 37 degrees C. The specimens were submitted to a shear bond strength test (n=14). Thermal gravimetric analysis was performed on the ceramic primer. The data obtained were statistically analyzed by two-way analysis of variance and the Tukey test (alpha=0.05). The experimental group G79 without aging (7.23 +/- 2.87 MPa) presented a significantly higher mean than the other experimental groups without aging (GC: 2.81 +/- 1.5 MPa; G20: 3.38 +/- 2.21 MPa; G100: 3.96 +/- 1.57 MPa), showing no difference from G45 only (G45: 6 +/- 3.63 MPa). All specimens of the aging groups debonded during thermocycling and were considered to present zero bond strength for the statistical analyses. In conclusion, heat treatment of the metal/zirconia primer improved bond strength under the initial condition but did not promote stable bonding under the aging condition.
Resumo:
Moisture equilibrium data of persimmon pulp powders with 50% maltodextrin (dry basis) obtained with different drying methods were determined at 20, 30, 40 and 50 degrees C. The spray-dryer gave a dry product with a higher adsorption capacity than the other methods. The vacuum- and freeze-dried products had the same adsorption capacity. The highest isosteric heat of sorption was observed for powders produced by spray-drying. The isokinetic temperature (T(B)) calculated for persimmon pulp powder obtained by vacuum-, spray- and freeze-drying were 541.4 K, 616.3 K, 513.2 K, respectively. The sorption process was spontaneous and enthalpy controlled.
Resumo:
Based on in vitro experiments, Bos indicus embryos were more resistant to heat stress (HS) than Bos taurus embryos. To increase knowledge regarding differences between Bos indicus and Bos taurus in resistance to HS, the primary objective of this study was to determine if tolerance to HS is due to the breed, origin of the oocyte, sperm, or both. Additionally, the influence of the interval between ovary acquisition (in the abattoir) and oocyte aspiration in the laboratory, on early embryo development was ascertained. Oocytes were collected from Nelore and Holstein cows in an abattoir; 4.0 or 6.5 h later, oocytes were aspired in the laboratory, and then matured and fertilized using semen from Nelore (N), Gir (GIR), or Holstein (H) bulls. Ninety-six h post insemination (hpi), embryos with >= 16 cells were divided in two groups: control and HS. In the control group, embryos were cultured at 39 degrees C, whereas in the HS group, embryos were subjected to 41 degrees C for 12 h, and then returned to 39 degrees C. Rates of cleavage, and formation of morula and blastocysts were higher (P < 0.05) for oocytes aspirated at 4.0 versus 6.5 h after ovaries were acquired. Heat stress decreased rates of blastocyst formation for all breeds (N X N; H x H; and H X GIR) and in both time intervals (4.0 and 6.5 h). However, N X N had higher cleavage rate (P < 0.05) in both time intervals when compared with H X H and H X GIR. In addition, Nelore oocytes fertilized with Nelore semen (N X N) had higher blastocyst yields (P < 0.05) in the control and HS group, when compared with the other two breeds (H X H and H X GIR). We concluded that the breed of origin of the oocyte was more important than that of the sperm for development of thermotolerance, because bull breed did not influence embryo development after HS, and in vitro early embryonic development was impaired by increasing (from 4 to 6.5 h) the interval between ovary acquisition and oocyte aspiration. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber, and bellows type. The evaluation was performed by in vitro tests of parameters such as heat transfer, pressure drop, and hemolysis tendency. The result has shown that all four systems tested were able to achieve the heat performance, and to offer low resistance to flow, and safety, as well as have low tendency to hemolysis. However, we can emphasize that the bellows type heat exchanger has a significant difference with regard to the other three types.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC). The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics) to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm(3).