992 resultados para Ponto de carga zero


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of afterload on peak rate of tension rise (dT/dt) in the isolated muscle. METHODS: Left ventricular papillary muscles from Wistar rats were studied in isometric and isotonic afterloaded contractions. Muscles were analised in Krebs-Henseleit solution with calcium concentration of 2.52mM at 28 degrees C. The resting muscle length (preload) was maintained constant. The peak isometric developed tension (DT) and dT/dt were measured during increases of afterload (25, 50, 75 and 100% from DT). RESULTS: A rise in afterload corresponding to 50, 75 and 100% of DT, did not cause an increase in dT/dt values (p > 0.05). The dT/dt value decreased (p < 0.05) when afterload was changed from 75% to 25% of DT. CONCLUSION: The data suggest that an increase in the afterload from 50% of the DT did not promote changes in the dT/dt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wear rate of the dual-phase steel ABNT-1020 tempered at 450°C sliding against cemented steel ABNT-1020 in function of load value is investigated in wide load range. The alteration in behavior of this function at intermediate load level, like in the case of low hardness steel sliding against high hardness steel, is observed. The analysis by scanning electronic microscope before and after this alteration showed a change of wear mechanism from plastic displacement to embrittlement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper represents the results of the work carried out in order to study the condition of seasonal consumer, the load factor and the more convenient tariff for a sugar mill located in the Vale do Paranapanema, SP, Brazil. Therefore, data of consume and registered demand were collected during the quadriennium 1990 to 1994. The studies showed that the factory did not maintain the condition of seasonal consumer of electric energy during the analysed period. Low values of the load factor observed in the period showed a non rational use of electric energy supplied by the concessionary. The results showed that only in one situation (load retired in top equal to 90%) the most convenient tariff is the horo-sazonal azul. In the other situations the most convenient tariff is the conventional one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solutions of a large class of hierarchies of zero-curvature equations that includes Toda- and KdV-type hierarchies are investigated. All these hierarchies are constructed from affine (twisted or untwisted) Kac-Moody algebras g. Their common feature is that they have some special vacuum solutions corresponding to Lax operators lying in some Abelian (up to the central term) subalgebra of g; in some interesting cases such subalgebras are of the Heisenberg type. Using the dressing transformation method, the solutions in the orbit of those vacuum solutions are constructed in a uniform way. Then, the generalized tau-functions for those hierarchies are defined as an alternative set of variables corresponding to certain matrix elements evaluated in the integrable highest-weight representations of g. Such definition of tau-functions applies for any level of the representation, and it is independent of its realization (vertex operator or not). The particular important cases of generalized mKdV and KdV hierarchies as well as the Abelian and non-Abelian affine Toda theories are discussed in detail. © 1997 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new family of dc-to-dc pulse-width-modulated (PWM) converters is presented. These converters feature soft-commutation at zero-current (ZC) in the active switches. The new ZCS-PWM Boost and new ZCS-PWM Zeta converters, both based on the new ZCS-PWM soft-commutation cell proposed, are used as examples to illustrate the operation of the new family of converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model for preventive control in electrical systems is presented, taking into account the dynamic aspects of the network. Among these aspects, the effects provoked by perturbations which cause oscillations in synchronous machine angles (transient stability), such as electric equipment outages and short circuits, are presented. The energy function is used to measure the stability of the system using a procedure defined as the security margin. The control actions employed are load shedding and generation reallocation. An application of the methodology to a system located in southern Brazil, which is composed of 10 synchronous machines, 45 busses, and 72 transmission lines. The results confirm the theoretical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Friction loss coefficients for laminar flow of xantan gum solutions (concentrations in the range of 0.1-0.5% by weight) through valves and fittings were experimentally determined. The rheological behavior, studied by means of a concentric cylinder rheometer, was pseudoplastic, being well described by the Ostwald-De Waele model with non-linear correlation coefficients (r) between 0.998 and 0.999. In the pressure drop measurements the following fittings were employed: completely open and half way open ball valve, completely open and half way open angle valve, tee used like coupling, tee used like a 90° elbow, short radius 90° elbow and coupling. The results showed that the friction loss coefficients increased with decreasing generalized Reynolds number. The friction loss coefficients could be well adjusted by a potential model, suggested by Kittredge & Rowley (1957) for Newtonian fluids, K f = A(Re g) -B, with correlation coefficients between 0.837 and 0.999.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Point positioning from GPS data can provide precision varying from 100 meters to a few millimeters at the level of 95% probability. To reach the best level of accuracy, users need proper equipment and software, as well as access capability to GPS products available at the International GPS Geodynamics Service. In this paper, the theory related to point positioning using GPS is presented as well as the results of an experiment conducted using data from the Brazilian Active Control System. The results show repeatability better than 5mm and 10mm for the N and E baseline components respectively, and 6mm + 4ppb (parts per billion) for the vertical. Comparison with SIRGAS campaign showed results at the same level of uncertainty as that of the stations used to tie the SIRGAS frame to ITRF94. Therefore, precise point positioning is a powerful tool to be used in applications requiring high level of precision, such as Geodynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationships between neutrophils oxidative metabolism, cortisol serum levels and worm burden, estimated by fecal egg count (EPG), were studied in sheep naturally infected by gastrointestinal parasites at the end of pregnancy, during lactation, and after weaning. Twenty-two Suffolk sheep three to four year old, of same parity and season of parturition were used. Serum cortisol was determined by radioimmunoassay and the neutrophils oxidative metabolism by the nitroblue tetrazolium (NBT) reduction test. The highest EPG values were observed on the fifth week of lactation while the highest rates of cortisol and reduction of NBT occurred on the fourth week after weaning. A positive correlation (r = 0.52; P<0.01) was observed between the neutrophils capacity to reduce the NBT and the serum cortisol concentration in the pre-parturition period. Otherwise, the neutrophils oxidative metabolism decreased near to the parturition. A negative correlation (r = -0.39; P<0.01) between EPG and NBT reduction test was observed after weaning, which was coincident with the increase in the neutrophils capacity to reduce NBT, indicating that animals showing better immune response after weaning have neutrophils with higher oxidative metabolism and lower worm burden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper explains the conceptual design of instrumentation that measures electric quantities defined in the trial-use Std. 1459-2000. It is shown how the Instantaneous-Space-Phasor (ISP) approach, based on α, β, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line and quantify the level of harmonic pollution injected by nonlinear loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents and discusses Ménard Pressuremeter test results used to predict bearing capacity of pounded piles installed in a tropical sandy soil. Fifteen pre-bored pressuremeter tests were carried out at the Experimental Research Site from Unesp - Bauru up to 15 m depth, one test per meter. Several laboratory and in situ tests were carried out in this research site as well as load tests on plates and on piles. Pressuremeter test results were firstly analyzed to determine geotechnical soil parameters based on empirical methods, emphasizing the estimative of the earth pressure coefficient at rest (K0). After that, bearing capacity prediction of pounded piles with 4 m, 7 m and 10 m were made and compared with test results from instrumented load tests. Pressuremeter test results allowed a very good estimative of bearing capacity for the pile with 4 m length and underestimated in 25,7% and 20,0% the bearing capacity for the pile with 7 and 10 m length, respectively. The back analysis of the test results suggests that the appropriate value for the bearing capacity factor for the tested soil-pile system on this soil is equal to 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the light-cone gauge choice for Abelian and non-Abelian gauge fields, the vector boson propagator carries in it an additional spurious or unphysical pole intrinsic to the choice requiring a careful mathematical treatment. Research in this field over the years has shown us that mathematical consistency only is not enough to guarantee physically meaningful results. Whatever the prescription invoked to handle such an object, it has to preserve causality in the process. On the other hand, the covariantization technique is a well-suited one to tackle gauge-dependent poles in the Feynman integrals, dispensing the use of ad hoc prescriptions. In this work we show that the covariantization technique in the light-cone gauge is a direct consequence of the canonical quantization of the theory. © World Scientific Publishing Company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main purpose of this study was to analyze the effect of the pedaling cadence (500 × 100 rpm) on the heart rate (HR) and the blood lactate response during incremental and constant workload exercises in active individuals. Nine active male individuals (20.9 ± 2.9 years old; 73.9 ± 6.5 kg; 1.79 ± 0.9 m) were submitted to two incremental tests, and to 6-8 constant workload tests to determine the intensity corresponding to the maximal steady state lactate (MLSSintens) in both cadences. The maximal power (Pmax) attained during the incremental test, and the MLSSintens were significantly lower at 100 rpm (240.9 ± 12.6 W; 148.1 ± 154.W) compared to 50 rpm (263.9 ± 18.6 W; 186.1 ± 21.2 W), respectively. The HRmax did not change between cadences (50 rpm = 191.1 ± 8.8 bpm; 100 rpm = 192.6 ± 9.9 bpm). Regardless the cadence, the HRmax percentage (70, 80, 90, and 100%) determined the same lactate concentrations during the incremental test. However, when the intensity was expressed in Pmax percentage or in absolute power, the lactate and the HR values were always higher at highest cadences. The HR corresponding to MLSSintens was similar between cadences (50 rpm = 162.5 ± 9.1 bpm; 100 rpm = 160.4 ± 9.2 bpm). Based on these results, it can be conclude that regardless the cadence employed (50 × 100 rpm), the use of the HR to individualize the exercise intensity indicates similar blood lactate responses, and this relationship is also kept in the exercise of constant intensity performed at MLSSintens. On the other hand, the use of the Pmax percentages depend on the cadence used, indicating different physiological responses to a same percentage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral rehabilitation of the patients toothless totals presents large difficulties, because diverse factors act limiting the treatment with complete dentures conventional, as severe reabsorption of the alveolar process, generating for the phonetic patient difficulties and of mastication, annoyance, retention lack and stability of the prosthesis. With the emergence of you implant them osseointegratin idealized by Prof o Branemark, these aspects were improved by means of the possibility of new treatment options, as the overdentures tissue-implant-supported. However, the protocol of Branemark demanded a period of scaring from three to six months, owing the patients to await this time for the placement of the final prosthesis. This way, the surgical technique of immediate load was proposed to abbreviate this period, improving the transition phase, at the same time that it reduces the problems psychological associates. This way, the objective of the present study is to carry out a literature revision about the works that used overdentures comparing immediate and late load, the best alternative and factors wrapped in the success of the procedure discussing. © 2008 1995, Editorial Ciencias médicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main drawbacks of the GPS accuracy for L1 users is the error due to ionosphere. This error depends on the total electron content presents in the ionosphere, as well as of the carrier frequency. Some models have been developed to correct GPS observables of the systematic error due to the ionosphere. The model more known and used is the Klobuchar model, which corrected 50-60% of the ionospheric error approximately. Alternatively, IGS (International GNSS Service) also has developed a model called Global Ionospheric Map (GIM). These maps, in format IONEX, are available in the site of the IGS, and one of the applications of them is to correct the GPS observables of the error due to ionosphere. This work aims at evaluating the quality of GPS point positioning using the IGS ionospheric model in the Brazilian region. Tests carried out had shown an average improvement in the horizontal and vertical determination of 72% and 26%, respectively, when GIM is used in the point positioning.