979 resultados para Photochemical fixation
Resumo:
Slightly displaced clavicular midshaft fracture is currently treated nonoperatively. There is considerable debate about whether acute displaced fractures should be treated operatively. Nonunion rate after displaced fracture has been underestimated for a long time, and malunion clinical impact often minimized. It is known that operative treatment decreases these rates. However, operating all displaced fractures may lead to overtreatment. Acute operative treatment of midshaft fractures with delayed treatment of established nonunion showed no significant difference in the outcome, but malunion surgical management is technically demanding. Consequently these fractures could be treated surgically, but operative indication should be adapted to patient expectations.
Resumo:
The populations of parasites and infectious agents are most of the time structured in complex hierarchy that lies beyond the classical nested design described by Wright's F-statistics (F(IS), F(ST) and F(IT)). In this note we propose a user-friendly step-by-step notice for using recent software (HierFstat) that computes and test fixation indices for any hierarchical structure. We add some tricks and tips for some special data kind (haploid, single locus), some other procedure (bootstrap over loci) and how to handle crossed factors.
Resumo:
INTRODUCTION: This is a single, level 1 trauma centre, prospective consecutive patient series with intramedullary infection in the presence of unstable tibial fracture treated using the Kirschner wire-reinforced, antibiotic cement nail. PATIENTS AND METHODS: A total of 10 consecutive patients (eight males and two females) with a mean age of 42 years (range, 20-59) suffering from infection after intramedullary nailing for tibial fracture, admitted during a period of 4 years, were included. An antibiotic cement-coated nail, handmade at the time of surgery, was implanted in all patients. This was followed by a standardised 6-week treatment protocol, extraction of the nail and definitive fixation. RESULTS: At 6 years of follow-up, infection eradication and bony union were possible in all of the patients. No further infection treatment was necessary; however, all of our patients underwent additional procedures (mean: four additional procedures per patient) for cosmetic or other non-infectious reasons (bone grafting, muscle flaps, etc.). CONCLUSIONS: The antibiotic cement-coated nail seems to be an effective treatment for intramedullary infections of the fractured tibia.
Resumo:
The vision-for-action literature favours the idea that the motor output of an action - whether manual or oculomotor - leads to similar results regarding object handling. Findings on line bisection performance challenge this idea: healthy individuals bisect lines manually to the left of centre, and to the right of centre when using eye fixation. In case that these opposite biases for manual and oculomotor action reflect more universal compensatory mechanisms that cancel each other out to enhance overall accuracy, one would like to observe comparable opposite biases for other material. In the present study, we report on three independent experiments in which we tested line bisection (by hand, by eye fixation) not only for solid lines, but also for letter lines; the latter, when bisected manually, is known to result in a rightward bias. Accordingly, we expected a leftward bias for letter lines when bisected via eye fixation. Analysis of bisection biases provided evidence for this idea: manual bisection was more rightward for letter as compared to solid lines, while bisection by eye fixation was more leftward for letter as compared to solid lines. Support for the eye fixation observation was particularly obvious in two of the three studies, for which comparability between eye and hand action was increasingly adjusted (paper-pencil versus touch screen for manual action). These findings question the assumption that ocular motor and manual output are always inter-changeable, but rather suggest that at least for some situations ocular motor and manual output biases are orthogonal to each other, possibly balancing each other out.
Resumo:
ABSTRACT Upregulation of the Major Facilitator transporter gene MDR1 (Multi_drug Resistance 1) is one of the mechanisms observed in Candida albicans clinical isolates developing resistance to azole antifungal agents. To better understand this phenomenon, the cis-acting regulatory elements present in a modulatable reporter system under the control of the MDR1 promoter were characterized. In an azole-susceptible strain, transcription of this reporter is transiently upregulated in response to either benomyl or H2O2, whereas its expression is constitutively high in an azole-resistant strain (FR2). Two cis-acting regulatory elements, that are necessary and sufficient to convey the same transcriptional responses to a heterologous promoter (CDR2), were identified within the MDR1promoter. The first element, called BRE (for Benomyl Response Element, -296 to -260 with respect to the ATG start codon), is required for benomyl-dependent MDR1 upregulation and for constitutive high expression of MDR1 in FR2. The second element, termed HRE (for H2O2 Response Element, -561 to -520), is required for H2O2-dependent MDR1 upregulation, but is dispensable for constitutive high expression. Two potential binding sites (TTAG/CTAA) for the blip transcription factor Cap1p lie within the HRE. Moreover, inactivation of CAP1 abolished the transient response to H2O2 and diminished significantly the transient response to benomyl. Cap1p, which has been previously implicated in cellular responses to oxidative stress, may thus play a transacting and positive regulatory role in benomyl- and H2O2-dependent transcription of MDR1. However, it is not the only transcription factor involved in the response of MDR1 to benomyl. A minimal BRE element (-290 to -273) that is sufficient to detect in vitro sequence-specific binding of protein complexes in crude extracts prepared from C. albicans was also delimited. Genome-wide transcript profiling analyses undertaken with a matched pair of clinical isolates, one of which being azole-resistant and upregulating MDR1, and with an azole-susceptible strain exposed to benomyl, revealed that genes specifically upregulated by benomyl harbour in their promoters Cap1p binding site(s). This strengthened the idea that Cap1p plays a role in benomyl-dependent upregulation of MDR1. BRE-like sequences were also identified in several genes co-regulated with MDR1 in both conditions, which was consistent with the involvement of the BRE in both processes. A set of 147 mutants lacking a single transcription factor gene was next screened for loss of MDR1response to benomyl. Unfortunately, none of the tested mutants showed a loss of benomyl-dependent MDR1 upregulation. Nevertheless, a significant diminution of the response was observed in the mutants in which the MADS-box transcription factor Mcm1p and the C2H2 zinc finger transcription factor orf19.13374p were inactivated, suggesting that Mcm1p and orf19.13374p are involved in MDR1response to benomyl. Interestingly, the BRE contains a perfect match to the binding consensus of Mcm1p, raising the possibility that MDR1may be a direct target of this transcriptional activator. In conclusion, while the identity of the trans-acting factors that bind to the BRE and HRE remains to be confirmed, the tools we have developed during characterization of the cis-acting elements of the MDR1promoter should now serve to elucidate the nature of the components that modulate its activity. RESUME La surexpression du gène MDR1 (pour Résistance Multidrogue 1), qui code pour un transporteur de la famille des Major Facilitators, est l'un des mécanismes observés dans les isolats cliniques de la levure Candida albicans développant une résistance aux agents antifongiques appelés azoles. Pour mieux comprendre ce phénomène, les éléments de régulation agissant en cis dans un système rapporteur modulable sous le contrôle du promoteur MDR1 ont été caractérisés. Dans une souche sensible aux azoles, la transcription de ce rapporteur est transitoirement surélevée en réponse soit au bénomyl soit à l'agent oxydant H2O2, alors que son expression est constitutivement élevée dans une souche résistante aux azoles (souche FR2). Deux éléments de régulation agissant en cis, nécessaires et suffisants pour transmettre les mêmes réponses transcriptionnelles à un promoteur hétérologue (CDR2), ont été identifiés dans le promoteur MDR1. Le premier élément, appelé BRE (pour Elément de Réponse au Bénomyl, de -296 à -260 par rapport au codon d'initiation ATG) est requis pour la surexpression de MDR1dépendante du bénomyl et pour l'expression constitutive de MDR1 dans FR2. Le deuxième élément, appelé HRE (pour Elément de Réponse à l'H2O2, de -561 à -520), est requis pour la surexpression de MDR1 dépendante de l'H2O2, mais n'est pas impliqué dans l'expression constitutive du gène MDR1. Deux sites de fixation potentiels (TTAG/CTAA) pour le facteur de transcription Cap1p ont été identifiés dans l'élément HRE. De plus, l'inactivation de CAP1 abolit la réponse transitoire à l'H2O2 et diminua significativement la réponse transitoire au bénomyl. Cap1p, qui est impliqué dans les réponses de la cellule au stress oxydatif, doit donc jouer un rôle positif en trans dans la surexpression de MDR1 dépendante du bénomyl et de l'H2O2. Cependant, ce n'est pas le seul facteur de transcription impliqué dans la réponse au bénomyl. Un élément BRE d'une longueur minimale (de -290 à -273) a également été défini et est suffisant pour détecter une interaction spécifique in vitro avec des protéines provenant d'extraits bruts de C. albicans. L'analyse du profil de transcription d'une paire d'isolats cliniques comprenant une souche résistante aux azoles surexprimant MDR1, et d'une souche sensible aux azoles exposée au bénomyl, a révélé que les gènes spécifiquement surexprimés par le bénomyl contiennent dans leurs promoteurs un ou plusieurs sites de fixation pour Cap1p. Ceci renforce l'idée que Cap1p joue un rôle dans la surexpression de MDR1dépendante du bénomyl. Une ou deux séquences ressemblant à l'élément BRE ont également été identifiées dans la plupart des gènes corégulés avec MDR1 dans ces deux conditions, ce qui était attendu compte-tenu du rôle joué par cet élément dans les deux processus. Une collection de 147 mutants dans lesquels un seul facteur de transcription est inactivé a été testée pour la perte de réponse au bénomyl de MDR1. Malheureusement, la surexpression de MDR1 dépendante du bénomyl n'a été perdue dans aucun des mutants testés. Néanmoins, une diminution significative de la réponse a été observée chez des mutants dans lesquels le facteur de transcription à MADS-box Mcm1p et le facteur de transcription à doigts de zinc de type C2H2 orf19.13374p ont été inactivés, suggérant que Mcm1p et orf19.13374p sont impliqués dans la réponse de MDR1au bénomyl. Il est intéressant de noter que la BRE contient une séquence qui s'aligne parfaitement avec la séquence consensus du site de fixation de Mcm1p, ce qui soulève la possibilité que MDR1 pourrait être une cible directe de cet activateur transcriptionnel. En conclusion, alors que l'identité des facteurs agissant en trans en se fixant à la BRE et à la HRE reste à être confirmée, les outils que nous avons développés au cours de la caractérisation des éléments agissant en cis sur le promoteur MDR1 peut maintenant servir à élucider la nature des composants modulant son activité.
Resumo:
Cultural variation in a population is affected by the rate of occurrence of cultural innovations, whether such innovations are preferred or eschewed, how they are transmitted between individuals in the population, and the size of the population. An innovation, such as a modification in an attribute of a handaxe, may be lost or may become a property of all handaxes, which we call "fixation of the innovation." Alternatively, several innovations may attain appreciable frequencies, in which case properties of the frequency distribution-for example, of handaxe measurements-is important. Here we apply the Moran model from the stochastic theory of population genetics to study the evolution of cultural innovations. We obtain the probability that an initially rare innovation becomes fixed, and the expected time this takes. When variation in cultural traits is due to recurrent innovation, copy error, and sampling from generation to generation, we describe properties of this variation, such as the level of heterogeneity expected in the population. For all of these, we determine the effect of the mode of social transmission: conformist, where there is a tendency for each naïve newborn to copy the most popular variant; pro-novelty bias, where the newborn prefers a specific variant if it exists among those it samples; one-to-many transmission, where the variant one individual carries is copied by all newborns while that individual remains alive. We compare our findings with those predicted by prevailing theories for rates of cultural change and the distribution of cultural variation.
Resumo:
Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilaterally in predrilled holes before inserting polymer screws. Static and dynamic bone parameters were analyzed based on in vivo microCT scans performed first weekly and then biweekly. The results showed that the locally released Zoledronate boosted bone formation rate up to 100% during the first 17 days after implantation and reduced the bone resorption rate up to 1000% later on. This shift in bone remodeling resulted in an increase in bone volume fraction (BV/TV) by 300% close to the screw and 100% further away. The double effect on bone formation and resorption indicates a great potential of Zoledronate-loaded hydrogel for enhancement of peri-implant bone volume which is directly linked to improved implant fixation.
Resumo:
Introduction: Pulmonary fat embolism (PFE) can be a cause of death in cases with trauma, during orthopedic surgery and also in non-traumatic conditions, such as burns, pancreatitis, fatty liver or sickle cell disease. As PMA becomes more widespread, it is important to determine how it affects the diagnosis of PFE. Aims: The aim of this study was to determine if the oily contrast liquid used in PMA induces artefactual PFE, if such artefacts differ from original PFE and if PFE can be detected and graded before PMA. Material and methods: Cases of adults without signs of postmortem change and for which an autopsy with angiography was performed were selected for this study. Pulmonary biopsies of each lung were taken before and after the angiography as were fragments of each lung with a twin-edged knife during the autopsy. The samples were examined under the microscope without fixation or staining and after an Oil-Red O staining. PFE was graded according to Falci et al. Results: Non-artefactual (original) PFE was diagnosed in 4 cases on pre-PMA biopsies. As expected, structures with the aspect of PFE were present in all cases after angiography. The microscopical aspect of original and PMA induced PFE was identical. Grading of the PFE according to Falci et al. was depending on the quality of the biopsies. Conclusions: PMA with oily contrast induces artefactual PFE that cannot be visually differentiated from original PFE. Original PFE can however be diagnosed with pre-angiography biopsies. In order to assure the diagnosis and correct grading of PFE, the quality of the biopsy should be checked before PMA with oily contrast.
Resumo:
Sex differences in cognition have been largely investigated. The most consistent sex differences favoring females are observed in object location memory involving the left hemisphere whereas the most consistent sex differences favoring males are observed in tasks that require mental rotation involving the right hemisphere. Here we used a task involving these two abilities to see the impact of mental rotation on object location memory. To that end we used a combination of behavioral and event-related potential (ERP) electroencephalography (EEG) measures.A computer screen displayed a square frame of 4 pairs of images (a "teddy" bear, a shoe, an umbrella and a lamp) randomly arranged around a central fixation cross. After a 10-second interval for memorization, images disappeared and were replaced by a test frame with no image but a random pair of two locations marked in black. In addition, this test frame was randomly displayed either in the original orientation (0° rotation) or in the rotated one (90° clockwise - CW - or 90° counterclockwise - CCW). Preceding the test frame, an arrow indicating the presence or the absence of rotation of the frame was displayed on the screen. The task of the participants (15 females and 15 males) was to determine if two marked locations corresponded or not to a pair of identical images. Each response was followed by feedback.Findings showed no significant sex differences in the performance of the original orientation. In comparison with this position, the rotation of the frame produced an equal decrease of male and female performance. In addition, this decrease was significantly higher when the rotation of the frame was in a CCW direction. We further assessed the ERP when the arrow indicated the direction of rotation as stimulus-onset, during four time windows representing major components C1, P1, N1 and N2. Although no sex differences were observed in performance, brain activities differed according to sex. Enhanced amplitudes were found for the CCW compared to CW rotation over the right posterior areas for the P1, N1 and N2 components for men as well as for women. Major topographical differences related to sex were measured for the CW rotation condition as marked lateralized amplitude: left-hemisphere amplitude larger than right one was measured during P1 time range for men. These similar patterns prolonged from P1 to N1 for women. Early distinctions were found in interaction with sex between CCW and CW waveform amplitudes, expressing over anterior electrode sites during C1 time range (0-50 ms post-stimulus).In conclusion (i) women do not outperform men in object location memory in this study (absence of rotation condition); (ii) mental rotation, in particular the direction of rotation, influences performance on object location memory; (iii) CCW rotation is associated with activity in the right parietal hemisphere whereas the CW rotation involves the left parietal hemisphere; (iv) this last effect is less pronounced in males, which could explain why greater involvement of right parietal areas in men and of bilateral posterior areas in women is generally reported in mental rotation tasks; and (v) the early distinctions between both directions of rotation located over anterior sites could be related to sex differences in their respective involvement of control mechanisms.
Resumo:
Résumé Les fractures extra capsulaires du fémur proximal sont connues pour le risque élevé de morbidité et de mortalité en cas de traitement non chirurgical. Ainsi, le clou Gamma standard a été produit pour garantir une fixation stable de ces fractures permettant par conséquent une mobilisation rapide et en charge des personnes en âge avancé et présentant ce genre de fracture. Mais il a été reproché à ce type de clou un nombre relativement élevé de fracture per ou post opératoire (environ 17%). Cette complication est liée au design de cet implant. Et, de ce fait, le clou Trochantéric a été créé pour remédier à cette complication en changeant la forme du clou et notamment sa courbure. Entre juillet 2000 et janvier 2001, 88 patients ont été traités par clou Trochantéric pour une fracture pertrochantérienne et suivis consécutivement dans notre Service. 75 patients, soit 76 fractures, ont pu être évalués cliniquement et radiologiquement durant une évolution de deux ans.
Resumo:
BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.
Resumo:
Introduction: Nonoperative treatment of displaced midshaft clavicle fractures is associated with higher nonunion rate than previously reported. Moreover, its occurrence can compromise shoulder function. The aim of this study was to evaluate the outcome of surgical treatment of symptomatic clavicle midshaft delayed and nonunion. Methods: Between 1999 and 2008, 19 clavicle delayed unions and nonunions were treated by open reduction and reconstructive plate fixation with augmentation by autologous bone graft. Iliac bone graft was used in 15 atrophic cases, and graft from the callus was used in 4 hypertrophic nonunions. There were 14 men and 5 women, with an average age of 41 years (range, 19 to 59 years) at time of surgery. No patient had undergone a previous surgery and all complained of shoulder pain. Delayed unions and nonunions were defined as non-healing after 3 and 6 months respectively. The mean time to surgery was 8 months (range, 4 to 23 months). All patients were pre and postoperatively clinically evaluated and imaged with standard radiographs until complete healing. Results: After a mean time of 3 months (range, 2 to 7 months) all fractures were completely healed. All patients reported full range of motion at time of last follow-up. Nine patients (47%) reported slight shoulder pain but all returned to their previous professional activities after a mean time of 3 months (range, 1 to 8 months). We reported 12 (63%) minor complications. There were 6 (32%) plate-related discomforts which resolved after hardware removal, two (11%) scar numbness, two (11%) adhesive capsulitis with spontaneous complete recovery, and two (11%) AC-joint pain treated successfully with local corticosteroids injection. Conclusion: Surgical treatment of delayed unions and nonunions of midshaft clavicle fractures yields satisfactory results and a high union rate. However, 50% of the patients may still complain of slight residual shoulder pain.
Resumo:
Centromedullary nailing is a well-established method of treatment for diaphyseal long bone fractures. The indications have been broadened greatly since the introduction in 1974 of interlocking centromedullary nailing. The purpose of this paper is to review our first results with locked intramedullary nailing of the tibia. We report our experience with the first 19 cases of interlocking tibia nails (15 fractures, 1 delayed union, 2 pseudarthrosis, 1 osteotomy). On the extension table, the insertion of the nail and the placement of the interlocking screws did not cause any problem. In 3 cases, a proximal screw had to be removed within two weeks because of spontaneous displacement. Complications have been noticed in three patients (15.8%) (pulmonary embolism on day 1, and compartment syndrome two days later in one case, sciatic nerve neuroapraxia in the other two). The other patients have been mobilized 24 to 48 hours after surgery. 94% of the fractures were consolidated 4 months post-operatively, with no major deformation. Interlocking tibia nailing seems to be an attractive method in the treatment of certain fractures of the tibia. Early mobilisation and weight-bearing are provided. The indications, the technical aspects as well as the dangers of the method must be carefully respected in order to avoid complications and poor results.
Resumo:
Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.
Resumo:
BACKGROUND: Greenstick fractures suffered during growth have a high risk for refracture and posttraumatic deformity, particularly at the forearm diaphysis. The use of a preemptive completion of the fracture by manipulation of the concave cortex is controversial and data supporting this approach are few. AIM: Aim of this study was to determine the factors which predispose to refracture and deformities, and to define therapeutic strategies. METHODS: We prospectively gathered clinical and radiographic data over a period of one year on greenstick fractures of the middle third of the forearm in children as part of a multi-centre study. Endpoint was a follow-up visit at one year. Radiographic deformity, state of consolidation at resumption of physical activities and refracture rate were analysed statistically (ANOVA, Student's t-test and Pearson's chi-square test) with regard to patient age, gender, fracture type, therapy and time in plaster. RESULTS: We collected the data of 103 patients (63 boys, 40 girls), average age 6.6 years (1.3-14.5 years), the vast majority of whom had a combined greenstick fracture of the radius and ulna. 6.7% of the patients sustained a refracture within 49 days (29-76) after plaster removal. They were significantly older (p=0.017) with a significantly higher incidence of manual completion of the fracture with radiographic signs of partial consolidation (p=0.025). Residual deformities were significantly smaller after completion of the fracture compared to reduction without completion (p=0.019) or plaster fixation alone (p<0.005). CONCLUSIONS: Completion of a greenstick fracture does not prevent refracture. Nevertheless, it diminishes the extent of secondary deformities in cases where the primary angulation exceeds the remodelling capacity. Prevention of refracture should include a routine radiographic follow-up 4-6 weeks after injury with continuation of plaster fixation in cases of partial consolidation.