963 resultados para Pelvic Floor Ultrasound
Resumo:
To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction.
Resumo:
Paravertebral regional anaesthesia is used to treat pain after several surgical procedures. This study aimed to improve on our first published ultrasound-guided approach to the paravertebral space (PVS) and to investigate a possible discrepancy between the needle, catheter, and contrast dye position.
Resumo:
Performing spermatic cord block for scrotal surgery avoids the potential risks of neuraxial and general anaesthesia and provides long-lasting postoperative analgesia. A blindly performed block is often inefficient and bears its own potential risks (intravascular injection of local anaesthetics, haematoma formation and perforation of the deferent duct). The use of ultrasound may help to overcome these disadvantages. The aim of this study was to test the feasibility and monitor the success rate of a new ultrasound-guided spermatic cord block.
Resumo:
BACKGROUND: Local anaesthetic blocks of the greater occipital nerve (GON) are frequently performed in different types of headache, but no selective approaches exist. Our cadaver study compares the sonographic visibility of the nerve and the accuracy and specificity of ultrasound-guided injections at two different sites. METHODS: After sonographic measurements in 10 embalmed cadavers, 20 ultrasound-guided injections of the GON were performed with 0.1 ml of dye at the classical site (superior nuchal line) followed by 20 at a newly described site more proximal (C2, superficial to the obliquus capitis inferior muscle). The spread of dye and coloration of nerve were evaluated by dissection. RESULTS: The median sonographic diameter of the GON was 4.2 x 1.4 mm at the classical and 4.0 x 1.8 mm at the new site. The nerves were found at a median depth of 8 and 17.5 mm, respectively. In 16 of 20 in the classical approach and 20 of 20 in the new approach, the nerve was successfully coloured with the dye. This corresponds to a block success rate of 80% (95% confidence interval: 58-93%) vs 100% (95% confidence interval: 86-100%), which is statistically significant (McNemar's test, P=0.002). CONCLUSIONS: Our findings confirm that the GON can be visualized using ultrasound both at the level of the superior nuchal line and C2. This newly described approach superficial to the obliquus capitis inferior muscle has a higher success rate and should allow a more precise blockade of the nerve.
Resumo:
Navigated ultrasound (US) imaging is used for the intra-operative acquisition of 3D image data during imageguided surgery. The presented approach includes the design of a compact and easy to use US calibration device and its integration into a software application for navigated liver surgery. User interaction during the calibration process is minimized through automatic detection of the calibration process followed by automatic image segmentation, calculation of the calibration transform and validation of the obtained result. This leads to a fast, interaction-free and fully automatic calibration procedure enabling intra-operative
Resumo:
This paper presents methods based on Information Filters for solving matching problems with emphasis on real-time, or effectively real-time applications. Both applications discussed in this work deal with ultrasound-based rigid registration in computer-assisted orthopedic surgery. In the first application, the usual workflow of rigid registration is reformulated such that registration algorithms would iterate while the surgeon is acquiring ultrasound images of the anatomy to be operated. Using this effectively real-time approach to registration, the surgeon would then receive feedback in order to better gauge the quality of the final registration outcome. The second application considered in this paper circumvents the need to attach physical markers to bones for anatomical referencing. Experiments using anatomical objects immersed in water are performed in order to evaluate and compare the different methods presented herein, using both 2D as well as real-time 3D ultrasound.
Resumo:
Although the ischial spine sign (ISS) has been advocated to detect acetabular retroversion, it is unknown whether the sign is valid on anteroposterior (AP) pelvic radiographs with tilted or rotated pelves. We therefore evaluated reliability of the ISS as a tool for diagnosing acetabular retroversion in the presence of considerable pelvic tilt and/or malrotation. We obtained radiographs of 20 cadaver pelves in 19 different malorientations resulting in 380 pelvis images (760 hips) for evaluation. In addition, 129 clinical radiographs of patients' hips that had varying pelvis orientations were reviewed. We found an overall sensitivity of 81% (90%), specificity of 70% (71%), positive predictive value of 77% (80.7%), and negative predictive value of 75% (85%) in the cadaver (patient) hips. Our data suggest the ISS is a valid tool for diagnosing acetabular retroversion on plain radiographs taken using a standardized technique regardless of the degree of pelvic tilt and rotation.
Resumo:
Major pelvic trauma results in high mortality. No standard technique to control pelvic hemorrhage has been identified.
Resumo:
Osteoarthritis is the most common form of joint disease and the leading cause of pain and physical disability in the elderly. Therapeutic ultrasound is one of several physical therapy modalities suggested for the management of pain and loss of function due to osteoarthritis (OA).
Resumo:
Aims: We investigated the impact of arterial injury on neointimal hyperplasia following implantation of drug-eluting stents (DES). Methods and results: A total of 196 patients with 223 segments (sirolimus-eluting stents [SES]: 104, paclitaxel-eluting stents [PES]: 119) underwent intravascular ultrasound eight months after DES implantation. Arterial injury was defined as the balloon-to-artery ratio (BAR). Segments were categorised into two groups: high BAR defined as BAR>1.1 (120 segments), and low BAR defined as BAR ≤1.1 (103 segments). Baseline clinical characteristics were similar for both groups. Although reference vessel diameter was smaller, stent diameter, maximal balloon pressure and balloon diameter were higher in the high BAR compared with the low BAR group. Lumen (7.10±1.91 vs. 6.25±1.69, p=0.001), stent (7.31±1.95 vs. 6.41±1.80, p=0.001), and external elastic membrane (17.1±4.9 vs. 14.8±4.0, p<0.0001) areas (mm2) were higher, but neointimal hyperplasia (0.21±0.36 vs. 0.16±0.48, p=0.42) area (mm2) was similar in the high BAR compared with the low BAR group. Arterial injury as assessed by BAR was not associated with the amount of neointimal hyperplasia (R2=0.003, p=0.40). Conclusions: Arterial injury does not correlate with the amount of neointimal hyperplasia following DES implantation. Conventionally aggressive DES implantation techniques do not adversely affect long-term outcome with respect to restenosis. - See more at: http://www.pcronline.com/eurointervention/30th_issue/79/#sthash.1do4X31G.dpuf
Resumo:
Prolonged postoperative pain and delayed intestinal transit are frequent problems following extended pelvic lymph-node dissection (PLND) and cystectomy.