862 resultados para Orthogonal Frequency Division Multiplexing
Resumo:
The theory of transient mode locking for an active modulator in an intracavity frequency-doubled laser is presented. The theory is applied to mode-locked and intracavity frequency-doubled Nd:YAG laser and the mode-locked pulse width is plotted as a function of number of round trips inside the cavity. It is found that the pulse compression is faster and the system takes a very short time to approach the steady state in the presence of a second harmonic generating crystal inside the laser cavity. The effect of modulation depth and the second harmonic conversion efficiency on the temporal behavior of the pulse width is discussed.
Resumo:
Chronic myeloid leukemia (CML) is a malignant clonal blood disease that originates from a pluripotent hematopoietic stem cell. The cytogenetic hallmark of CML, the Philadelphia chromosome (Ph), is formed as a result of reciprocal translocation between chromosomes 9 and 22, which leads to a formation of a chimeric BCR-ABL fusion gene. The BCR-ABL protein is a constitutively active tyrosine kinase that changes the adhesion properties of cells, constitutively activates mitogenic signaling, enhances cell proliferation and reduces apoptosis. This results in leukemic growth and the clinical disease, CML. With the advent of targeted therapies against the BCR-ABL fusion protein, the treatment of CML has changed considerably during the recent decade. In this thesis, the clinical significance of different diagnostic methods and new prognostic factors in CML have been assessed. First, the association between two different methods for measuring CML disease burden (the RQ-PCR and the high mitotic index metaphase FISH) was assessed in bone marrow and peripheral blood samples. The correlation between positive RQ-PCR and metaphase FISH samples was high. However, RQ-PCR was more sensitive and yielded measurable transcripts in 40% of the samples that were negative by metaphase FISH. The study established a laboratory-specific conversion factor for setting up the International Scale when standardizing RQ-PCR measurements. Secondly, the amount of minimal residual disease (MRD) after allogeneic hematopoietic stem cell transplantation (alloHSCT) was determined. For this, metaphase FISH was done for the bone marrow samples of 102 CML patients. Most (68%), had no residual cells during the entire follow-up time. Some (12 %) patients had minor (<1%) MRD which decreased even further with time, whereas 19% had a progressive rise in MRD that exceeded 1% or had more than 1% residual cells when first detected. Residual cells did not become eradicated spontaneously if the frequency of Ph+ cells exceeded 1% during follow-up. Next, the impact of deletions in the derivative chromosome 9, was examined. Deletions were observed in 15% of the CML patients who later received alloHSCT. After alloHSCT, there was no difference in the total relapse rate in patients with or without deletions. Nor did the estimates of overall survival, transplant-related mortality, leukemia-free survival and relapse-free time show any difference between these groups. When conventional treatment regimens are used, the der(9) status could be an important criterion, in conjunction with other prognostic factors, when allogeneic transplantation is considered. The significance of der(9) deletions for patients treated with tyrosine kinase inhibitors is not clear and requires further investigation. In addition to the der(9) status of the patient, the significance of bone marrow lymphocytosis as a prognostic factor in CML was assessed. Bone marrow lymphocytosis during imatinib therapy was a positive predictive factor and heralded optimal response. When combined with major cytogenetic response at three months of treatment, bone marrow lymphocytosis predicted a prognostically important major molecular response at 18 months of imatinib treatment. Although the validation of these findings is warranted, the determination of the bone marrow lymphocyte count could be included in the evaluation of early response to imatinib treatment already now. Finally, BCR-ABL kinase domain mutations were studied in CML patients resistant against imatinib treatment. Point mutations detected in the kinase domain were the same as previously reported, but other sequence variants, e.g. deletions or exon splicing, were also found. The clinical significance of the other variations remains to be determined.
Resumo:
Low pressure radio frequency plasma-assisted deposition of 1-isopropyl-4-methyl-1,4-cyclohexadiene thin films was investigated for different polymerization conditions. Transparent, environmentally stable and flexible, these organic films are promising candidates for organic photovoltaics (OPV) and flexible electronics applications, where they can be used as encapsulating coatings and insulating interlayers. The effect of deposition RF power on optical properties of the films was limited, with all films being optically transparent, with refractive indices in a range of 1.57–1.58 at 500 nm. The optical band gap (Eg) of ~3 eV fell into the insulating Eg region, decreasing for films fabricated at higher RF power. Independent of deposition conditions, the surfaces were smooth and defect-free, with uniformly distributed morphological features and average roughness between 0.30 nm (at 10 W) and 0.21 nm (at 75 W). Films fabricated at higher deposition power displayed enhanced resistance to delamination and wear, and improved hardness, from 0.40 GPa for 10 W to 0.58 GPa for 75 W at a load of 700 μN. From an application perspective, it is therefore possible to tune the mechanical and morphological properties of these films without compromising their optical transparency or insulating property.
Resumo:
Radio frequency plasma enhanced chemical vapor deposition is currently used to fabricate a broad range of functional coatings. This work described fabrication and characterization of a novel bioactive coating, polyterpenol, for encapsulation of three-dimensional indwelling medical devices. The materials are synthesized from monoterpene alcohols under different input power conditions. The chemical composition and structure of the polyterpenol thin films were determined by Xray photoelectron spectroscopy (XPS), Fourier transform infrared (FTIR) spectroscopy, contact angle measurements, and atomic force microscopy (AFM). The application of polyterpenol coating to the substrate reduced surface roughness from 1.5 to 0.4 of a nanometer, and increased the water contact angle from to 9 to 72 degrees. The extent of attachment and extracellular polysaccharide (EPS) production of two medically relevant pathogens, Staphylococcus aureus and Staphylococcus epidermis were analyzed using scanning electron microscopy (SEM) and confocal scanning laser microscopy (CSLM). Application of polyterpenol coating fabricated at 10 W significantly inhibited attachment and growth of both pathogens compared to unmodified substrates, whilst addition of 50 W films resulted in an increased attachment, proliferation and EPS production by both types of bacteria when compared to unmodified surface. Marked dissimilarity in bacterial response between two coatings was attributed to changes in surface chemistry, nano-architecture and surface energy of polymer thin films deposited under different input power conditions.
Resumo:
Recent advancements in the area of organic polymer applications demand novel and advanced materials with desirable surface, optical and electrical properties to employ in emerging technologies. This study examines the fabrication and characterization of polymer thin films from non-synthetic Terpinen-4-ol monomer using radio frequency plasma polymerization. The optical properties, thickness and roughness of the thin films were studied in the wavelength range 200–1000 nm using ellipsometry. The polymer thin films of thickness from 100 nm to 1000 nm were fabricated and the films exhibited smooth and defect-free surfaces. At 500 nm wavelength, the refractive index and extinction coefficient were found to be 1.55 and 0.0007 respectively. The energy gap was estimated to be 2.67 eV, the value falling into the semiconducting Eg region. The obtained optical and surface properties of Terpinen-4-ol based films substantiate their candidacy as a promising low-cost material with potential applications in electronics, optics, and biomedical industries.
Resumo:
This note presents the statistical analysis carried out on some of the available experimental results to predict the resonant frequency and maximum displacement amplitude of a machine foundation – soil system under vertical vibration as a function of the size and weight of the foundation and of the excitation level. A total of 442 experimental results of Fry, Novak, and Raman have been analysed using nonlinear regression analysis. The results obtained compared well with predictions obtained from the popular theoretical models, and the coefficient of correlation obtained from the analysis was satisfactory in most of the cases.
Resumo:
The surface instability of a semi-infinite plasma immersed in a high frequency field is investigated. When the natural Langmuir frequency of the surface is nearly equal to the frequency of the high frequency field, the dispersion relation predicts build-up of oscillations with a growth rate comparable with the real part of the frequency. Threshold values above which the instability is possible are derived.
Resumo:
Surface instability of a collisionless semi-infinite current carrying plasma is studied. The semi-infinite plasma bounded by a plane surface is under the influence of a high frequency (hf) field. There are two classes of surface modes. One is a normal extension of zero high frequency field and the other due entirely to the presence ofhf field. As expected, with the increase in thehf field, the growth rates of the surface instabilities decrease. There are regions defined by the electron drift velocityu where the unstable surface and bulk regions overlap. The interesting result is that unlike the bulk plasma, there is a stable region on theu-axis flanked by two unstable regions. The width of this stable region increases with the increase in the field strength.
Resumo:
The interaction of intense coherent light with Frenkel excitons has been studied for investigating the self-induced transparency. Some nonlinear effects neglected before have been included. It is found that the frequency spectrum consistent with the pulse propagation is wider by two orders of magnitude compared with the previous result.
Resumo:
This study compared the effects of a low-frequency electrical stimulation (LFES; Veinoplus® Sport, Ad Rem Technology, Paris, France), a low-frequency electrical stimulation combined with a cooling vest (LFESCR) and an active recovery combined with a cooling vest (ACTCR) as recovery strategies on performance (racing time and pacing strategies), physiologic and perceptual responses between two sprint kayak simulated races, in a hot environment (∼32 wet-bulb-globe temperature). Eight elite male kayakers performed two successive 1000-m kayak time trials (TT1 and TT2), separated by a short-term recovery period, including a 30-min of the respective recovery intervention protocol, in a randomized crossover design. Racing time, power output, and stroke rate were recorded for each time trial. Blood lactate concentration, pH, core, skin and body temperatures were measured before and after both TT1 and TT2 and at mid- and post-recovery intervention. Perceptual ratings of thermal sensation were also collected. LFESCR was associated with a very likely effect in performance restoration compared with ACTCR (99/0/1%) and LFES conditions (98/0/2%). LFESCR induced a significant decrease in body temperature and thermal sensation at post-recovery intervention, which is not observed in ACTCR condition. In conclusion, the combination of LFES and wearing a cooling vest (LFESCR) improves performance restoration between two 1000-m kayak time trials achieved by elite athletes, in the heat.
Resumo:
Inadvertent climate modification has led to an increase in urban temperatures compared to the surrounding rural area. The main reason for the temperature rise is the altered energy portioning of input net radiation to heat storage and sensible and latent heat fluxes in addition to the anthropogenic heat flux. The heat storage flux and anthropogenic heat flux have not yet been determined for Helsinki and they are not directly measurable. To the contrary, turbulent fluxes of sensible and latent heat in addition to net radiation can be measured, and the anthropogenic heat flux together with the heat storage flux can be solved as a residual. As a result, all inaccuracies in the determination of the energy balance components propagate to the residual term and special attention must be paid to the accurate determination of the components. One cause of error in the turbulent fluxes is the fluctuation attenuation at high frequencies which can be accounted for by high frequency spectral corrections. The aim of this study is twofold: to assess the relevance of high frequency corrections to water vapor fluxes and to assess the temporal variation of the energy fluxes. Turbulent fluxes of sensible and latent heat have been measured at SMEAR III station, Helsinki, since December 2005 using the eddy covariance technique. In addition, net radiation measurements have been ongoing since July 2007. The used calculation methods in this study consist of widely accepted eddy covariance data post processing methods in addition to Fourier and wavelet analysis. The high frequency spectral correction using the traditional transfer function method is highly dependent on relative humidity and has an 11% effect on the latent heat flux. This method is based on an assumption of spectral similarity which is shown not to be valid. A new correction method using wavelet analysis is thus initialized and it seems to account for the high frequency variation deficit. Anyhow, the resulting wavelet correction remains minimal in contrast to the traditional transfer function correction. The energy fluxes exhibit a behavior characteristic for urban environments: the energy input is channeled to sensible heat as latent heat flux is restricted by water availability. The monthly mean residual of the energy balance ranges from 30 Wm-2 in summer to -35 Wm-2 in winter meaning a heat storage to the ground during summer. Furthermore, the anthropogenic heat flux is approximated to be 50 Wm-2 during winter when residential heating is important.
Resumo:
The low-frequency (5–100 kHz) dielectric constant epsilon (Porson) has been measured in the temperature range 7 × 10−5 < t = (T − Tc)/Tc < 8 × 10−2. Near Tc an exponent ≈0.11 characterizes the power law behaviour of Image consistent with the theoretically predicted t−α singularity. However, over the full range of t an exponent ≈0.35 is obtained.
Resumo:
A divide-and-correct algorithm is described for multiple-precision division in the negative base number system. In this algorithm an initial quotient estimate is obtained from suitable segmented operands; this is then corrected by simple rules to arrive at the true quotient.