961 resultados para Optimization methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a microwave-assisted extraction (MAE) methodology was compared with several conventional extraction methods (Soxhlet, Bligh & Dyer, modified Bligh & Dyer, Folch, modified Folch, Hara & Radin, Roese-Gottlieb) for quantification of total lipid content of three fish species: horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), and sardine (Sardina pilchardus). The influence of species, extraction method and frozen storage time (varying from fresh to 9 months of freezing) on total lipid content was analysed in detail. The efficiencies of methods MAE, Bligh & Dyer, Folch, modified Folch and Hara & Radin were the highest and although they were not statistically different, differences existed in terms of variability, with MAE showing the highest repeatability (CV = 0.034). Roese-Gottlieb, Soxhlet, and modified Bligh & Dyer methods were very poor in terms of efficiency as well as repeatability (CV between 0.13 and 0.18).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers, corroborating the increased exposure to risk factors, such as fungal load and their metabolites. This study aimed to determine the occupational exposure threat due to fungal contamination caused by the toxigenic isolates belonging to the complex of the species of Aspergillus flavus and also isolates fromAspergillus fumigatus species complex. The study was carried out in seven Portuguese poultries, using cultural and molecularmethodologies. For conventional/cultural methods, air, surfaces, and litter samples were collected by impaction method using the Millipore Air Sampler. For the molecular analysis, air samples were collected by impinger method using the Coriolis μ air sampler. After DNA extraction, samples were analyzed by real-time PCR using specific primers and probes for toxigenic strains of the Aspergillus flavus complex and for detection of isolates from Aspergillus fumigatus complex. Through conventional methods, and among the Aspergillus genus, different prevalences were detected regarding the presence of Aspergillus flavus and Aspergillus fumigatus species complexes, namely: 74.5 versus 1.0% in the air samples, 24.0 versus 16.0% in the surfaces, 0 versus 32.6% in new litter, and 9.9 versus 15.9%in used litter. Through molecular biology, we were able to detect the presence of aflatoxigenic strains in pavilions in which Aspergillus flavus did not grow in culture. Aspergillus fumigatus was only found in one indoor air sample by conventional methods. Using molecular methodologies, however, Aspergillus fumigatus complex was detected in seven indoor samples from three different poultry units. The characterization of fungal contamination caused by Aspergillus flavus and Aspergillus fumigatus raises the concern of occupational threat not only due to the detected fungal load but also because of the toxigenic potential of these species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a new method for single-drop microextraction (SDME) for the preconcentration of organochlorine pesticides (OCP) from complex matrices. It is based on the use of a silicone ring at the tip of the syringe. A 5 μL drop of n-hexane is applied to an aqueous extract containing the OCP and found to be adequate to preconcentrate the OCPs prior to analysis by GC in combination with tandem mass spectrometry. Fourteen OCP were determined using this technique in combination with programmable temperature vaporization. It is shown to have many advantages over traditional split/splitless injection. The effects of kind of organic solvent, exposure time, agitation and organic drop volume were optimized. Relative recoveries range from 59 to 117 %, with repeatabilities of <15 % (coefficient of variation) were achieved. The limits of detection range from 0.002 to 0.150 μg kg−1. The method was applied to the preconcentration of OCPs in fresh strawberry, strawberry jam, and soil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A QuEChERS method has been developed for the determination of 14 organochlorine pesticides in 14 soils from different Portuguese regions with wide range composition. The extracts were analysed by GC-ECD (where GC-ECD is gas chromatography-electron-capture detector) and confirmed by GC-MS/MS (where MS/MS is tandem mass spectrometry). The organic matter content is a key factor in the process efficiency. An optimization was carried out according to soils organic carbon level, divided in two groups: HS (organic carbon>2.3%) and LS (organic carbon<2.3%). Themethod was validated through linearity, recovery, precision and accuracy studies. The quantification was carried out using a matrixmatched calibration to minimize the existence of the matrix effect. Acceptable recoveries were obtained (70–120%) with a relative standard deviation of ≤16% for the three levels of contamination. The ranges of the limits of detection and of the limits of quantification in soils HS were from 3.42 to 23.77 μg kg−1 and from 11.41 to 79.23 μg kg−1, respectively. For LS soils, the limits of detection ranged from 6.11 to 14.78 μg kg−1 and the limits of quantification from 20.37 to 49.27 μg kg−1. In the 14 collected soil samples only one showed a residue of dieldrin (45.36 μg kg−1) above the limit of quantification. This methodology combines the advantages of QuEChERS, GC-ECD detection and GC-MS/MS confirmation producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET),maximum excitation energy or “q” value (q), and isolationmass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit.Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project was developed to fully assess the indoor air quality in archives and libraries from a fungal flora point of view. It uses classical methodologies such as traditional culture media – for the viable fungi – and modern molecular biology protocols, especially relevant to assess the non-viable fraction of the biological contaminants. Denaturing high-performance liquid chromatography (DHPLC) has emerged as an alternative to denaturing gradient gel electrophoresis (DGGE) and has already been applied to the study of a few bacterial communities. We propose the application of DHPLC to the study of fungal colonization on paper-based archive materials. This technology allows for the identification of each component of a mixture of fungi based on their genetic variation. In a highly complex mixture of microbial DNA this method can be used simply to study the population dynamics, and it also allows for sample fraction collection, which can, in many cases, be immediately sequenced, circumventing the need for cloning. Some examples of the methodological application are shown. Also applied is fragment length analysis for the study of mixed Candida samples. Both of these methods can later be applied in various fields, such as clinical and sand sample analysis. So far, the environmental analyses have been extremely useful to determine potentially pathogenic/toxinogenic fungi such as Stachybotrys sp., Aspergillus niger, Aspergillus fumigatus, and Fusarium sp. This work will hopefully lead to more accurate evaluation of environmental conditions for both human health and the preservation of documents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Although relative uptake values aren’t the most important objective of a 99mTc-DMSA scan, they are important quantitative information. In most of the dynamic renal scintigraphies attenuation correction is essential if one wants to obtain a reliable result of the quantification process. Although in DMSA scans the absent of significant background and the lesser attenuation in pediatric patients, makes that this attenuation correction techniques are actually not applied. The geometric mean is the most common method, but that includes the acquisition of an anterior (extra) projection, which it is not acquired by a large number of NM departments. This method and the attenuation factors proposed by Tonnesen will be correlated with the absence of attenuation correction procedures. Material and Methods: Images from 20 individuals (aged 3 years +/- 2) were used and the two attenuation correction methods applied. The mean time of acquisition (time post DMSA administration) was 3.5 hours +/- 0.8h. Results: The absence of attenuation correction showed a good correlation with both attenuation methods (r=0.73 +/- 0.11) and the mean difference verified on the uptake values between the different methods were 4 +/- 3. The correlation was higher when the age was lower. The attenuation correction methods correlation was higher between them two than with the “no attenuation correction” method (r=0.82 +/- 0.8), and the mean differences of the uptake values were 2 +/- 2. Conclusion: The decision of not doing any kind of attenuation correction method can be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for an accurate value of the relative kidney uptake, then an attenuation correction method should be used. Attenuation correction factors proposed by Tonnesen can be easily implemented and so become a practical and easy to implement alternative, namely when the anterior projection - needed for the geometric mean methodology – is not acquired.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are launching a long-term study to characterize the biodiversity at different elevations in several Azorean Islands. Our aim is to use the Azores as a model archipelago to answer the fundamental question of what generates and maintains the global spatial heterogeneity of diversity in islands and to be able to understand the dynamics of change across time. An extensive, standardized sampling protocol was applied in most of the remnant forest fragments of five Azorean Islands. Fieldwork followed BRYOLAT methodology for the collection of bryophytes, ferns and other vascular plant species. A modified version of the BALA protocol was used for arthropods. A total of 70 plots (10 m x 10 m) are already established in five islands (Flores, Pico, São Jorge, Terceira and São Miguel), all respecting an elevation step of 200 m, resulting in 24 stations examined in Pico, 12 in Terceira, 10 in Flores, 12 in São Miguel and 12 in São Jorge. The first results regarding the vascular plants inventory include 138 vascular species including taxa from Lycopodiophyta (N=2), Pteridophyta (N=27), Pinophyta (N=2) and Magnoliophyta (N=107). In this contribution we also present the main research question for the next six years within the 2020 Horizon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo optimização energética na indústria química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projecto para obtenção do grau de Mestre em Engenharia Informática e de computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A maximização do potencial da abordagem cirúrgica conservadora da axila para o cancro da mama, como um método minimamente invasivo para a avaliação de metastização axilar, visando diminuir a morbilidade associada ao esvaziamento axilar completo, requer um método preciso para avaliação patológica intraoperatória. Esse método não foi ainda estabelecido. Imprints e corte de congelação do gânglio sentinela são os procedimentos comummente utilizados, apesar de uma sensibilidade e especificidade inferior à desejada. Actualmente, novas técnicas estão a ser desenvolvidas, que apesar da sua optimização, ainda não ultrapassam os resultados das utilizadas. Um total de 138 mulheres com cancro da mama, submetidas a cirurgia mamária por abordagem conservadora da axila, cuja utilização de imprints e cortes de congelação foram os métodos de avaliação intraoperatória do gânglio sentinela. Os diagnósticos dados pela observação dos cortes dos fragmentos do exame extemporâneo foram comparados com os obtidos nos cortes histológicos definitivos dos fragmentos fixados em formol e incluídos em parafina. Os resultados obtidos da avaliação do exame extemporâneo demonstraram sensibilidade de 79,1%, especificidade de 96,9%, com uma precisão de 91,4%. Não se obteve correlação entre os resultados do extemporâneo e os parâmetros de caracterização do exame extemporâneo e tumores. Os métodos, imprints e cortes de congelação, actualmente utilizados na nossa instituição apresentam bons resultados, mas a adopção de apenas um ou outro necessita de uma análise mais aprofundada dos dados relativos à metodologia utilizada nos extemporâneos, de forma a verificar a especificidade e sensibilidade individualizadas dos imprints e dos cortes de congelação. Se os imprints se revelarem semelhantes aos cortes de congelação, a sua utilização é preferencial uma vez que acarreta menores custos e são menos morosos. A implementação de novas técnicas será uma metodologia adoptar, pelos benefícios acrescidos, porém mais estudos e a optimização