986 resultados para Optics|Biophysics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two typical alternative conformations for double strandee polynucleotides with Watson-Crick base pairing scheme are presented. these types avoid tangling of the chains. Representative models of these types with two different views, to show the similarity and dissimilarity between these models and the Watson-Crick model, are given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that the use of a coarsely quantized binary digital hologram as a matched filter on an optical computer does not degrade signal-to-noise ratio (SNR) appreciably.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper describes a novel method of finding the position and orientation of a relatively rigid molecule in the unit cell from criteria concerning allowed contact distances between atoms. On application to the crystal structure of a hexapeptide, C25H31N6O8.2H2O, it was possible to solve the structure from this starting point, by a series of SFLS refinements with an increasingly larger number of reflexions at successive stages. The packing analysis succeeded, even though the water molecules were not included to start with.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study on the conformational aspects of cyclo-hexaglycyl having inversion symmetry has been made. The cyclic backbone has been assumed to have two internal 4→1 types of NH... O hydrogen bonds. This molecule has been found to take up two types of conformations designated asA* andB* having nearly the same energy values. The theoretical conformations have been compared with the conformations of cyclohexaglycyl hemihydrate observed in the crystal structure. Two molecules with an approximate inversion symmetry are close to the conformation of the typeB* and two other molecules with exact inversino symmetry correspond nearly to the typesB* andA*. comparison with the theoretically possible conformations of cyclohexaglycyl molecule with 2-fold symmetry has been made. The preference of inversion symmetry and preferred ranges ofψ for glycyl molecules is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rarity of occurrence of cis peptide units is only partially explained by the higher intrinsic energy of the cis over the trans form, which provides a probability of 0·01 for cis peptide units to occur. An additional factor is the conformational restriction imposed by the occurrence of a cis peptide unit in a chain of trans units. Taking a section of three peptide units having the sequences trans-trans-trans (ttt) and trans-cis-trans (tct), conformational energy calculations indicate that the latter can occur only to an extent of 0·1%, unless there occurs the sequence X-Pro, in which case it is of the order of 30%. This explains the extreme rarity of cis peptide units, in general; however, it follows that even with non-prolyl residues, cis peptide units are not forbidden, but can occur in some rare examples and should be looked for.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two different matrix algorithms are described for the restoration of blurred pictures. These are illustrated by numerical examples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early identification of diabetic foot complications and their precursors is essential in preventing their devastating consequences, such as foot infection and amputation. Frequent, automatic risk assessment by an intelligent telemedicine system might be feasible and cost effective. Infrared thermography is a promising modality for such a system. The temperature differences between corresponding areas on contralateral feet are the clinically significant parameters. This asymmetric analysis is hindered by (1) foot segmentation errors, especially when the foot temperature and the ambient temperature are comparable, and by (2) different shapes and sizes between contralateral feet due to deformities or minor amputations. To circumvent the first problem, we used a color image and a thermal image acquired synchronously. Foot regions, detected in the color image, were rigidly registered to the thermal image. This resulted in 97.8% ± 1.1% sensitivity and 98.4% ± 0.5% specificity over 76 high-risk diabetic patients with manual annotation as a reference. Nonrigid landmark-based registration with Bsplines solved the second problem. Corresponding points in the two feet could be found regardless of the shapes and sizes of the feet. With that, the temperature difference of the left and right feet could be obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early detection of (pre-)signs of ulceration on a diabetic foot is valuable for clinical practice. Hyperspectral imaging is a promising technique for detection and classification of such (pre-)signs. However, the number of the spectral bands should be limited to avoid overfitting, which is critical for pixel classification with hyperspectral image data. The goal was to design a detector/classifier based on spectral imaging (SI) with a small number of optical bandpass filters. The performance and stability of the design were also investigated. The selection of the bandpass filters boils down to a feature selection problem. A dataset was built, containing reflectance spectra of 227 skin spots from 64 patients, measured with a spectrometer. Each skin spot was annotated manually by clinicians as "healthy" or a specific (pre-)sign of ulceration. Statistical analysis on the data set showed the number of required filters is between 3 and 7, depending on additional constraints on the filter set. The stability analysis revealed that shot noise was the most critical factor affecting the classification performance. It indicated that this impact could be avoided in future SI systems with a camera sensor whose saturation level is higher than 106, or by postimage processing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To examine whether anterior scleral and conjunctival thickness undergoes significant diurnal variation over a 24-hour period. Methods Nineteen healthy young adults (mean age 22 ± 2 years) with minimal refractive error (mean spherical equivalent refraction -0.08 ± 0.39 D), had measures of anterior scleral and conjunctival thickness collected using anterior segment optical coherence tomography (AS-OCT) at seven measurement sessions over a 24-hour period. The thickness of the temporal anterior sclera and conjunctiva were determined at 6 locations (each separated by 0.5 mm) at varying distances from the scleral spur for each subject at each measurement session. Results Both the anterior sclera and conjunctiva were found to undergo significant diurnal variations in thickness over a 24-hour period (both p <0.01). The sclera and conjunctiva exhibited a similar pattern of diurnal change, with a small magnitude thinning observed close to midday, and a larger magnitude thickening observed in the early morning immediately after waking. The amplitude of diurnal thickness change was larger in the conjunctiva (mean amplitude 69 ± 29 μm) compared to the sclera (21 ± 8 μm). The conjunctiva exhibited its smallest magnitude of change at the scleral spur location (mean amplitude 56 ± 17 μm) whereas the sclera exhibited its largest magnitude of change at this location (52 ± 21 μm). Conclusions This study provides the first evidence of diurnal variations occurring in the thickness of the anterior sclera and conjunctiva. Studies requiring precise measures of these anatomical layers should therefore take time of day into consideration. The majority of the observed changes occurred in the early morning immediately after waking and were of larger magnitude in the conjunctiva compared to the sclera. Thickness changes at other times of the day were of smaller magnitude and generally not statistically significant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thickness measurements derived from optical coherence tomography (OCT) images of the eye are a fundamental clinical and research metric, since they provide valuable information regarding the eye’s anatomical and physiological characteristics, and can assist in the diagnosis and monitoring of numerous ocular conditions. Despite the importance of these measurements, limited attention has been given to the methods used to estimate thickness in OCT images of the eye. Most current studies employing OCT use an axial thickness metric, but there is evidence that axial thickness measures may be biased by tilt and curvature of the image. In this paper, standard axial thickness calculations are compared with a variety of alternative metrics for estimating tissue thickness. These methods were tested on a data set of wide-field chorio-retinal OCT scans (field of view (FOV) 60° x 25°) to examine their performance across a wide region of interest and to demonstrate the potential effect of curvature of the posterior segment of the eye on the thickness estimates. Similarly, the effect of image tilt was systematically examined with the same range of proposed metrics. The results demonstrate that image tilt and curvature of the posterior segment can affect axial tissue thickness calculations, while alternative metrics, which are not biased by these effects, should be considered. This study demonstrates the need to consider alternative methods to calculate tissue thickness in order to avoid measurement error due to image tilt and curvature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two variants of a simplified procedure for the isolation of plasma membrane fractions from monkey and rat brains, are described. The preparations show marked enrichments in the marker enzymes, (Na+-K+) adenosine triphosphatase, acetylcholinesterase, 5′-nucleotidase and adenylate cyclase. Lipid analysis and a protein electrophoretic pattern are presented. An enzymatic check has been made to assess for contamination by other cellular organelles. The amino acid composition of brain membrane proteins show a resemblance to the reported composition of erythrocyte ghost proteins but differ from myelin proteins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possible nonplanar distortions of the amide group in formamide, acetamide, N-methylacetamide, and N-ethylacetamide have been examined using CNDO/2 and INDO methods. The predictions from these methods are compared with the results obtained from X-ray and neutron diffraction studies on crystals of small open peptides, cyclic peptides, and amides. It is shown that the INDO results are in good agreement with observations, and that the dihedral angles N and defining the nonplanarity of the amide unit are correlated approximately by the relation N = -2, while C is small and uncorrelated with . The present study indicates that the nonplanar distortions at the nitrogen atom of the peptide unit may have to be taken into consideration, in addition to the variation in the dihedral angles (,), in working out polypeptide and protein structures.