985 resultados para Objective Monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the relevant achievements in the control of the main Chagas disease vectors Triatoma infestans and Rhodnius prolixus, several factors still promote the risk of infection. The disease is a real threat to the poor rural regions of several countries in Latin America. The current situation in Brazil requires renewed attention due to its high diversity of triatomine species and to the rapid and drastic environmental changes that are occurring. Using the biology, behaviour and diversity of triatomines as a basis for new strategies for monitoring and controlling the vectorial transmission are discussed here. The importance of ongoing long-term monitoring activities for house infestations by T. infestans, Triatoma brasiliensis, Panstrongylus megistus, Triatoma rubrovaria and R. prolixus is also stressed, as well as understanding the invasion by sylvatic species. Moreover, the insecticide resistance is analysed. Strong efforts to sustain and improve surveillance procedures are crucial, especially when the vectorial transmission is considered interrupted in many endemic areas.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic resuscitation should be aimed at achieving not only adequate cardiac output but also sufficient mean arterial pressure (MAP) to guarantee adequate tissue perfusion pressure. Since the arterial pressure response to volume expansion (VE) depends on arterial tone, knowing whether a patient is preload-dependent provides only a partial solution to the problem. The objective of this study was to assess the ability of a functional evaluation of arterial tone by dynamic arterial elastance (Ea(dyn)), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, to predict the hemodynamic response in MAP to fluid administration in hypotensive, preload-dependent patients with acute circulatory failure. METHODS We performed a prospective clinical study in an adult medical/surgical intensive care unit in a tertiary care teaching hospital, including 25 patients with controlled mechanical ventilation who were monitored with the Vigileo(®) monitor, for whom the decision to give fluids was made because of the presence of acute circulatory failure, including arterial hypotension (MAP ≤65 mmHg or systolic arterial pressure <90 mmHg) and preserved preload responsiveness condition, defined as a SVV value ≥10%. RESULTS Before fluid infusion, Ea(dyn) was significantly different between MAP responders (MAP increase ≥15% after VE) and MAP nonresponders. VE-induced increases in MAP were strongly correlated with baseline Ea(dyn) (r(2) = 0.83; P < 0.0001). The only predictor of MAP increase was Ea(dyn) (area under the curve, 0.986 ± 0.02; 95% confidence interval (CI), 0.84-1). A baseline Ea(dyn) value >0.89 predicted a MAP increase after fluid administration with a sensitivity of 93.75% (95% CI, 69.8%-99.8%) and a specificity of 100% (95% CI, 66.4%-100%). CONCLUSIONS Functional assessment of arterial tone by Ea(dyn), measured as the PVV to SVV ratio, predicted arterial pressure response after volume loading in hypotensive, preload-dependent patients under controlled mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Poor medication adherence is a frequent cause of treatment failure but is difficult to diagnose. In this study we have evaluated the impact of measuring adherence to cinacalcet-HCl and phosphate binders in dialysis patients with uncontrolled secondary hyperparathyroidism. METHODS: 7 chronic dialysis patients with iPTH-levels >= 300 pg/ml despite treatment with >= 60 mg cinacalcet-HCl were included. Medication adherence was measured using the "Medication Events Monitoring System" during 3 months, followed by another 3-month period without monitoring. The adherence results were monthly discussed with the patients, as well as strategies to improve them. RESULTS: During monitoring, the percentage of prescribed doses taken was higher for cinacalcet-HCl (87.4%) and sevelamer (86.3%) than for calcium acetate (76.1%), as was the taking adherence (81.9% vs. 57.3% vs. 49.1%) but not the percentage of drug holidays (12.3% vs. 4.5% vs. 3.6%). Mean PO4 levels (from 2.24 +/- 0.6 mmol/l to 1.73 +/- 0.41 mmol/l; p = 0.14) and Ca++ x PO4 product (4.73 +/- 1.43 to 3.41 +/- 1.04 mmol2/l2; p = 0.12) improved and iPTH-level improved significantly from 916 +/- 618 pg/ml to 442 +/- 326 pg/ml (p = 0.04), without any change in medication. However, as drug monitoring was interrupted, all laboratory parameters worsened again. CONCLUSIONS: Assessment of drug adherence helped to document episodes of non-compliance and helped to avoid seemingly necessary dose increases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The study objective was to derive reference pharmacokinetic curves of antiretroviral drugs (ART) based on available population pharmacokinetic (Pop-PK) studies that can be used to optimize therapeutic drug monitoring guided dosage adjustment.¦Methods: A systematic search of Pop-PK studies of 8 ART in adults was performed in PubMed. To simulate reference PK curves, a summary of the PK parameters was obtained for each drug based on meta-analysis approach. Most models used one-compartment model, thus chosen as reference model. Models using bi-exponential disposition were simplified to one-compartment, since the first distribution phase was rapid and not determinant for the description of the terminal elimination phase, mostly relevant for this project. Different absorption were standardized for first-order absorption processes.¦Apparent clearance (CL), apparent volume of distribution of the terminal phase (Vz) and absorption rate constant (ka) and inter-individual variability were pooled into summary mean value, weighted by number of plasma levels; intra-individual variability was weighted by number of individuals in each study.¦Simulations based on summary PK parameters served to construct concentration PK percentiles (NONMEM®).¦Concordance between individual and summary parameters was assessed graphically using Forest-plots. To test robustness, difference in simulated curves based on published and summary parameters was calculated using efavirenz as probe drug.¦Results: CL was readily accessible from all studies. For studies with one-compartment, Vz was central volume of distribution; for two-compartment, Vz was CL/λz. ka was directly used or derived based on the mean absorption time (MAT) for more complicated absorption models, assuming MAT=1/ka.¦The value of CL for each drug was in excellent agreement throughout all Pop-PK models, suggesting that minimal concentration derived from summary models was adequately characterized. The comparison of the concentration vs. time profile for efavirenz between published and summary PK parameters revealed not more than 20% difference. Although our approach appears adequate for estimation of elimination phase, the simplification of absorption phase might lead to small bias shortly after drug intake.¦Conclusions: Simulated reference percentile curves based on such an approach represent a useful tool for interpretating drug concentrations. This Pop-PK meta-analysis approach should be further validated and could be extended to elaborate more sophisticated computerized tool for the Bayesian TDM of ART.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Applications of genetic constructs with multiple promoters, which are fused with reporter genes and simultaneous monitoring of various events in cells, have gained special attention in recent years. Lentiviral vectors, with their distinctive characteristics, have been considered to monitor the developmental changes of cells in vitro. In this study, we constructed a novel lentiviral vector (FUM-M), containing two germ cell-specific promoters (Stra8 and c-kit), fused with ZsGreen and DsRed2 reporter genes, and evaluated its efficiency in different cells following treatments with retinoic acid and DMSO. Several cell lines (P19, GC-1 spg and HEK293T) were transduced with this vector, and functional capabilities of the promoters were verified by flow cytometry and quantitative RT-PCR. Our results indicate that FUM-M shows dynamic behavior in the presence and absence of extrinsic factors. A correlation was also observed between the function of promoters, present in the lentiviral construct and the endogenous level of the Stra8 and c-kit mRNAs in the cells. In conclusion, we recommend this strategy, which needs further optimization of the constructs, as a beneficial and practical way to screen chemical inducers involved in cellular differentiation toward germ-like cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of attractants and larvicides in oviposition traps is of practical interest for the surveillance and control of urban mosquitoes. In addition to increasing the safety of the traps, this combination is essential for an attract-and-kill control strategy based on trapping mosquito eggs. The combination of Bacillus thuringiensis var. israelensis (Bti) and grass infusion (GI) vs. GI alone were tested for their ability to attract in paired BR-OVT traps in the backyards of 10 houses in Recife, Brazil, for a period of 45 days. Results show that females prefer to oviposit in traps containing Bti (363 compared with 251 egg rafts over 45 days). Results from a one-year trial on the efficacy of BR-OVT traps loaded with GI and Bti as a sampling tool to monitor temporal fluctuations in the population densities of Culex quinquefasciatus in an urban environment are also reported. From December 2006-January 2007, one trap per home was installed and maintained for 348 consecutive days in 134-151 houses located in three urban blocks. Throughout the one-year field trial a total of 43,151 Culex egg rafts were collected in the traps. The data show that BR-OVT loaded with GI and Bti is sensitive enough to demonstrate continuous reproductive activity of Cux. quinquefasciatus in the study area throughout the year and to monitor temporal fluctuations in population density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The epidemiological features of rotavirus A (RVA) infection differ between children from developing and developed countries which could result in differences in vaccine efficacy around the world. To evaluate the impact of RotarixTM on RVA prevalence, we monitored RVA genotypes circulating in Goiânia by monitoring virus in faecal samples from children that had or had not been previously vaccinated. From February-November of 2008, 220 faecal samples were collected from children in seven day-care centres. RVA detection was performed by two methodologies and the results were confirmed by polyacrylamide gel electrophoresis. From the 220 samples, eight were RVA-positive (3.6%) and five were from children that had received either one or two doses of the vaccine. All positive samples were collected from children with diarrhoea during August and September. Genotyping of the RVA characterised five of the viral samples as genotype G2P[4] and one as G8P[4], suggesting that G2P[4] was the predominant circulating genotype in Goiânia during the study. The fact that vaccinated children were also infected by RVA suggests that the vaccine does not fully protect against infection by the G2[P4] RVA genotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The second scientific workshop of the European Crohn's and Colitis Organization (ECCO) focused on the relevance of intestinal healing for the disease course of inflammatory bowel disease (IBD). The objective was to better understand basic mechanisms, markers for disease prediction, detection and monitoring of intestinal healing, impact of intestinal healing on the disease course of IBD as well as therapeutic strategies. The results of this workshop are presented in four separate manuscripts. This section describes basic mechanisms of intestinal healing, identifies open questions in the field and provides a framework for future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nepal has a long history of medical radiology since1923 but unfortunately, we still do not have any Radiation Protection Infrastructure to control the use of ionizing radiations in the various fields. The objective of this study was an assessment of the radiation protection in medical uses of ionizing radiation. Twenty-eight hospitals with diagnostic radiology facility were chosen for this study according to patient loads, equipment and working staffs. Radiation surveys were also done at five different radiotherapy centers. Questionnaire for radiation workers were used; radiation dose levels were measured and an inventory of availability of radiation equipment made. A corollary objective of the study was to create awareness in among workers on possible radiation health hazard and risk. It was also deemed important to know the level of understanding of the radiation workers in order to initiate steps towards the establishment of Nepalese laws, regulation and code of radiological practice in this field. Altogether, 203 Radiation workers entertained the questionnaire, out of which 41 are from the Radiotherapy and 162 are from diagnostic radiology. The radiation workers who have participated in the questionnaire represent more than 50% of the radiation workers working in this field in Nepal. Almost all X-ray, CT and Mammogram installations were built according to protection criteria and hence found safe. Radiation dose level at the reference points for all the five Radiotherapy centers are within safe limit. Around 65% of the radiation workers have never been monitored for radiation. There is no quality control program in any of the surveyed hospitals except radiotherapy facilities.