895 resultados para Nano partículas
Resumo:
Polymeric materials have become the reference material for high reliability and performance applications. However, their performance in service conditions is difficult to predict, due in large part to their inherent complex morphology, which leads to non-linear and anisotropic behavior, highly dependent on the thermomechanical environment under which it is processed. In this work, a multiscale approach is proposed to investigate the mechanical properties of polymeric-based material under strain. To achieve a better understanding of phenomena occurring at the smaller scales, the coupling of a finite element method (FEM) and molecular dynamics (MD) modeling, in an iterative procedure, was employed, enabling the prediction of the macroscopic constitutive response. As the mechanical response can be related to the local microstructure, which in turn depends on the nano-scale structure, this multiscale approach computes the stress-strain relationship at every analysis point of the macro-structure by detailed modeling of the underlying micro- and meso-scale deformation phenomena. The proposed multiscale approach can enable prediction of properties at the macroscale while taking into consideration phenomena that occur at the mesoscale, thus offering an increased potential accuracy compared to traditional methods.
Resumo:
A saturação do solo de fundação de um edifício pode estar associada a danos neste, por intermédio de assentamentos de colapso. A anulação da sucção matricial, que representa o efeito das forças inter-partículas de natureza capilar, é responsável por estes assentamentos. Neste trabalho utilizou-se um algoritmo especificamente formulado para simular os assentamentos por colapso. Foram feitas análises numéricas dos assentamentos e danos provocados na fachada em alvenaria de um edifício pela saturação ocorrida numa zona do solo de fundação. Foi estudada a influência dos seguintes factores: a sucção inicial do solo, o grau de pré-consolidação do solo e a extensão e localização da zona saturada.
Resumo:
A monitorização de processos ambientais conduz à obtenção de resultados cuja aferição da qualidade é um requisito raramente cumprido. No entanto, importantes decisões de gestão ambiental, sociais e políticas com impacto directo nas populações são tomadas suportadas nestes resultados. A validação de uma medição, como suporte à decisão, é impossível sem o conhecimento da incerteza associada ao próprio resultado. É a incerteza que define a qualidade do resultado. Com este trabalho pretendeu-se contribuir para o aperfeiçoamento do Controlo da Poluição na Refinaria da Galp Energia, em Sines, através do estabelecimento de um projecto de cálculo das incertezas associadas aos teores de poluentes medidos. Foram alvo deste estudo os valores medidos de dióxido de enxofre, óxidos de azoto e partículas monitorizadas. O conhecimento do valor de incerteza associada aos resultados permitirá actuar preventivamente e tomar acções correctivas de modo a garantir o cumprimento pleno da licença ambiental. Para avaliar a incerteza usou-se o procedimento preconizado pela norma ISO em que os passos envolvidos são a especificação do processo de medida, identificação das fontes de incerteza, cálculo da incerteza combinada e cálculo da incerteza expandida. Após a caracterização da actividade da empresa, do enquadramento legislativo, do desempenho no triénio 2005-2007 e da caracterização dos aparelhos de medida, foi feito um estudo estatístico aos valores medidos por estes três analisadores durante diversos períodos do ano de 2007 e foi determinado o modelo de cálculo do valor de incerteza associado a cada uma das medidas. Os valores, associados à respectiva incerteza, foram comparados com os limites impostos pela licença ambiental, verificando-se o cumprimento desta. A determinação da incerteza associada aos resultados de monitorização dos efluentes gasosos desta instalação reforça a credibilidade dos valores medidos, o compromisso da melhoria contínua da qualidade dos processos, produtos e serviços, do desempenho ambiental e da segurança das pessoas e bens, como contributo para um desenvolvimento sustentável desta companhia.
Resumo:
Este trabalho teve como principal objectivo caracterizar a exposição de crianças a partículas atmosféricas e aos elementos químicos que as constituem. Pretendeu-se também determinar as fontes e processos que afectam os níveis e composição das partículas em suspensão no ar ambiente e no interior de salas de aula de escolas do 1º ciclo localizadas no centro de Lisboa. Os efeitos das partículas atmosféricas na saúde humana manifestam-se sobretudo ao nível do aparelho respiratório, dependendo da sua composição química, e principalmente da sua dimensão. As partículas inaláveis (PM10) podem depositar-se nas unidades funcionais do sistema respiratório. O PM2,5 podem atingir os alvéolos pulmonares e penetrar no sistema circulatório. As crianças são um dos principais grupos de risco, visto que os seus órgãos e tecidos ainda estão em desenvolvimento, ficando mais susceptíveis à exposição de partículas. A recolha de material particulado foi realizada no ar ambiente recorrendo a um colector PARTISOL e no interior e exterior das escolas usando amostradores GENT. A concentração total de partículas em suspensão foi determinada por gravimetria. A caracterização química da matéria particulada foi efectuada por Análise por Activação com Neutrões (INAA) para a determinação da concentração dos elementos e por Cromatografia Iónica para a quantificação de iões solúveis em água. Em 2007, a concentração média anual de PM2,5 no Centro de Lisboa foi de 18µg/m3. Através da Análise de Componentes Principais e Regressão Multilinear verificou-se que a massa das partículas da fracção fina resulta essencialmente da produção de aerossóis secundários (35%) de uma fonte de cálcio (28%) e da emissão de poluentes por veículos motorizados (23%). No interior das escolas verificou-se que as concentrações de partículas são mais elevadas comparativamente com o ambiente exterior, principalmente no PM2,5-10 (74µg/m3). A ressuspensão de partículas causada pelas actividades desempenhadas no interior das salas e a suspensão de poeiras do solo transportada pelas crianças, são as principais causas apontadas. O Ca é o elemento maioritário no interior das escolas. Os resultados obtidos neste trabalho não excederam os limites estabelecidos pela Legislação Portuguesa.
Resumo:
A qualidade de vida do ser humano é grandemente influenciada pelo ar que respiram. Grande parte da população passa a maior parte do seu tempo em ambientes interiores, pelo que a qualidade do ar presente nesses ambientes é de extrema importância para a saúde da população. Os elevados níveis de concentração das partículas suspensas em atmosferas interiores constituem um risco na saúde da população exposta. O presente trabalho consistiu em avaliar os níveis de concentração de partículas suspensas em atmosferas interiores, numa escola do ensino básico e num laboratório de ortoprotesia, utilizando o método automático que consiste em medir amostras de ar através do equipamento Handheld 3016 IAQ, obtendo-se directamente os valores de concentração e o número de partículas suspensas no ar interior, e concluir, de acordo com as normas ISO 7730:2005, NP 1796:2007 e com Decreto –Lei nº 79/2006 de 4 de Abril sobre a qualidade do ar presente no interior dos locais analisados. Os resultados obtidos permitiram concluir que os níveis de concentração de partículas suspensas nas atmosferas interiores da escola se encontram dentro dos valores limite estabelecidos pelas normas, e que para o laboratório de ortoprotesia, os níveis de concentração de partículas não se encontram dentro dos valores estabelecidos pelo SCE, embora cumpram os requisitos da norma NP 1796:2007.
Resumo:
Este trabalho teve como objectivos estudar a relação entre os teores de aerossóis medidos na cidade de Lisboa e as condições meteorológicas registadas. O período de amostragem decorreu entre 20 de Janeiro e 19 de Fevereiro de 2009, a designada “Campanha de Inverno” do Projecto de Investigação “Contaminação da atmosfera urbana de Lisboa por Hidrocarbonetos Aromáticos Policíclico (PAHLis)”. Foram seleccionados dois locais da cidade de Lisboa com diferentes níveis de poluição: Olivais e Avenida da Liberdade. Nestes locais existem também estações da Rede da Qualidade do Ar cujos dados foram usados para completar e validar os dados por nós recolhidos. O étodo usado para a determinação da concentração de PM foi o método de referência (método gravimétrico) referido pelas normas EN 12341:1998 e EN 14907:2005. Em cada local, foram recolhidas partículas em suspensão no ar através de amostradores Gent e High-Vol. O Gent é um amostrador de baixo volume (cerca de 12 L de ar por minuto) que possui duas unidades de filtros de policarbonato de dois tamanhos de poro sendo assim possível a recolha de partículas PM2.5 e PM10-2.5 separadamente. O High-Vol é um equipamento de amostragem de alto volume (cerca de 1 m3 de ar por minuto) e onde foram usados dois filtros de quartzo em cascata para a recolha de partículas PM2.5 e PM10-2.5. Verificou-se que os amostradores não foram totalmente eficazes na separação das partículas, segundo os diâmetros aerodinâmicos pretendidos. Os dados apresentaram alguma discrepância face aos dados obtidos pelos High-Vol e também face aos dados obtidos pelos medidores das estações. Optou-se assim pela utilização dos dados obtidos com o amostrador High-Vol. Verifica-se que a Avenida da Liberdade é dos locais de estudo o mais poluído e que a concentração da fracção fina é mais elevada. Tal facto deve-se provavelmente à intensa circulação automóvel, principal fonte poluidora no local. Para o período em estudo e neste local, foi obtida uma média de 16.5 µg/m3 de PM 10-2.5 e 21.9 µg/m3 de PM 2.5. No mesmo período registou-se nos Olivais uma média de 9.0 µg/m3 para a fracção grosseira e 12.3 µg/m3 para a fracção fina. Os dados meteorológicos foram fornecidos pelas estações meteorológicas localizadas nas imediações dos locais em estudo: estação MeteoPortela e estação do Instituto Dom Luiz. Foram recolhidos e tratados dados de temperatura, precipitação, humidade, velocidade e direcção do vento. Com recurso à análise de componentes principais (PCA) foi possível verificar a relação e influência das condições meteorológicas sobre os teores de partículas. Foi possível a redução das variáveis iniciais tendo-se concluído que a humidade, a percipitação e a velocidade do vento são as condições que maior influência têm sobre as partículas. Um aumento destas variáveis provoca uma diminuição global do teor das partículas. Para uma clara definição de um modelo PCA para estes dados, os estudos deverão se prolongados no tempo.
Resumo:
Nanomaterials (NMs) with the same chemistry can greatly differ by size, surface area, shape, stability, rigidness, coating or electrical charge and these characteristics affect nano-bio interactions, leading to different toxic potential. In this communication is shown that closely related NMs can have different genotoxic effects, evidencing the importance of investigating the toxic potential of each NM individually, instead of assuming a common mechanism and equal genotoxic effects for a set of similar NMs. The importance of considering complexity of in vivo systems in nanotoxicology, such as the use of tridimensional cellular models, air-liquid interface exposure or in vivo models that mimic human routes of exposure, is underlined.
Resumo:
A dislipidemia é um distúrbio do perfil lipídico, seja por elevação ou diminuição de partículas lipídicas. O objetivo deste trabalho é fazer uma revisão dos casos com dislipidemia rara em estudo no Instituto Nacional de Saúde Doutor Ricardo Jorge, apresentando os dados clínicos e moleculares mais relevantes. O perfil lipídico foi determinado para cada caso índex e familiares e o estudo molecular dos genes envolvidos foi realizado por amplificação por PCR e sequenciação de Sanger. Foram estudados, ou está em curso o estudo, de 14 casos índex com os seguintes diagnósticos clínicos: Deficiência familiar em lipoproteína lípase (3), Lipodistrofia familiar parcial de Dunningan Tipo 2 (1), Deficiência em lípase ácida lisossomal (3), Abeta/hipobetalipoproteinemia (2), Deficiência em HDL (1), Hipertrigliceridemia autossómica recessiva (3), Sitosterolemia (1). O fenótipo clínico de cada caso índex é variável dependendo de cada condição. Foi encontrada a causa genética da doença em 8/14 doentes, estando os restantes ainda em estudo. Doentes com as várias dislipidemias raras apresentadas têm um risco acrescido de ter outras doenças graves como pancreatite, doença cardiovascular ou complicações neurológicas e devem, por esta razão, ser identificados o mais precocemente possível, de forma a minimizar ou prevenir os efeitos nefastos destas condições.
Resumo:
Mestrado em Segurança e Higiene no Trabalho.
Resumo:
The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 μm2/cm3, which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) μm have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Protecção contra Radiações
Resumo:
Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.
Resumo:
O volume de águas residuais tratadas tem vindo a aumentar nos últimos anos devido ao cumprimento da legislação em vigor – visando a proteção dos meios recetores das cargas poluentes rejeitas pelos aglomerados urbanos e industriais. A maioria das estações de tratamento de águas residuais é projetada para reduzir a carga poluente de natureza química, não removendo de forma significativa a contaminação por microrganismos patogénicos. Determinados usos dos meios recetores como a produção de água para consumo humano, águas balneares, águas para suporte de vida aquícola, bem como a reutilização dos efluentes das estações de tratamento de águas residuais para rega, entre outros, requerem a redução da carga de patogénicos, levando à inclusão de processos de desinfeção a montante da descarga. Na atualidade, o processo de desinfeção de águas residuais mais vantajoso na generalidade das situações é a radiação ultravioleta, em detrimento dos processos químicos anteriormente utilizados (como a utilização de cloro). Este trabalho pretende documentar o desempenho das instalações de desinfeção por radiação ultravioleta em Portugal, através da avaliação da eficiência de remoção de microrganismos indicadores de contaminação fecal (coliformes fecais) e dos fatores que a podem condicionar, como o teor de sólidos em suspensão, as caraterísticas dos equipamentos utilizados e suas condições de operação e manutenção. Tendo sido identificadas as estações de tratamento de águas residuais com desinfeção por radiação ultravioleta operacional em Portugal, foi possível efetuar a escolha de 9 delas para integrarem os casos de estudo, com base num questionário remetido às respetivas entidades gestoras. A eficiência do processo de desinfeção dos casos de estudo foi inferida através da comparação das concentrações de coliformes fecais no afluente à unidade de desinfeção e no efluente da estação de tratamento de águas residuais, a qual também permitiu efetuar uma análise relativa às diversas aptidões de reutilização da água residual tratada, à luz de diversos documentos legislativos e normativos, nacionais e europeus. Após a análise e processamento dos dados recolhidos dos casos de estudo, concluiu-se que todos eles apresentavam processos de desinfeção eficientes, com redução efetiva de coliformes fecais e que, a reduzida concentração de partículas em suspensão no afluente às unidades de desinfeção concorreu para o seu bom desempenho, evidenciando assim, a importância de o tratamento que precede a desinfeção assegurar a efetiva remoção de sólidos em suspensão até valores médios da ordem dos 14 mg/L.
Resumo:
Atualmente, o impacto ambiental gerado pela produção de cimento é uma das grandes preocupações a nível mundial. O seu processo de produção requer não só a utilização de quantidades significativas de recursos naturais não renováveis bem como de consumo de energia. Concomitantemente, a produção de cimento é a maior fonte de emissão antropogénica de CO2 para a atmosfera. Desta forma, várias medidas têm sido concebidas com o intuito de diminuir estes impactos visando a preservação do meio ambiente. Uma dessas medidas consiste em substituir parcialmente cimento por resíduos industriais. Neste sentido, com o presente trabalho pretendeu-se avaliar o efeito da moagem do catalisador exausto da unidade de “cracking” catalítico (FCC) - proveniente da refinaria da GALP, em Sines - nas propriedades de argamassas em que este resíduo substitui parcialmente o cimento. Na campanha experimental prepararam-se argamassas com substituição parcial de cimento por resíduo de FCC – entre os 0 a 15%, em massa – com três distribuições de tamanho de partículas de resíduo distintas. Na preparação destas argamassas adotaram-se duas abordagens experimentais que originaram duas séries de argamassas: numa das séries, a consistência das argamassas no estado fresco varia em função do teor de catalisador incorporado e na outra série, a consistência das argamassas é mantida constante através da adição de superplastificante, independentemente do teor de catalisador incorporado. As propriedades das argamassas no estado fresco avaliadas foram: a consistência por espalhamento, o teor de ar e a massa volúmica. No estado endurecido avaliou-se: a velocidade de propagação de ondas ultrassónicas nas argamassas, a resistência mecânica, a aderência e a absorção de água por capilaridade. Com o presente estudo verifica-se que a utilização de resíduo moído como substituto parcial do cimento, aumenta a trabalhabilidade da argamassa para substituições de 15%. Para substituições de 5% e 10%, a moagem do resíduo não se apresenta sensível à trabalhabilidade. A moagem deste resíduo de FCC também não tem um efeito significativo nos valores de resistência à compressão das argamassas em que é incorporado, embora se verifique uma tendência para que os resíduos moídos conduzam a valores resistência à compressão mais elevados quando comparado com o não moído, particularmente quando a percentagem de incorporação do resíduo é mais elevada. A atividade pozolânica aumenta com a moagem do resíduo de FCC. A introdução de resíduo moído conduz à diminuição da absorção de água por capilaridade, à medida que a percentagem de substituição aumenta.
Resumo:
A qualidade do betão pode ser controlada pelo comportamento da fluidez da pasta de cimento, o qual está relacionado com a dispersão das partículas de cimento. Um dos maiores avanços na tecnologia do betão tem sido o desenvolvimento de aditivos. Um destes tipos de aditivos, os Superplastificantes (SP), fornecem a possibilidade de se obter uma melhor dispersão das partículas de cimento, produzindo pastas com elevada fluidez. Com o desenvolvimento de betões de alta resistência e elevado desempenho, os superplastificantes tornaram-se indispensáveis. Os superplastificantes são adsorvidos nas partículas de cimento e esta adsorção depende da composição do clínquer do cimento e do tipo de SP utilizado. Com a difusão do emprego dos aditivos redutores de água, têm surgido vários problemas de compatibilidade cimento/adjuvante. Esta investigação dedicada aos superplastificantes, fortes redutores de água, visou estudar quais as propriedades que poderiam influenciar a sua compatibilidade/robustez com o cimento. Também se procurou ganhar experiência com as técnicas analíticas de caracterização de adjuvantes. Assim, utilizou-se um tipo de cimento e dois tipos de superplastificantes (poli(étercarboxilatos) e poli(naftalenossulfonatos)) disponíveis no mercado português. Mantendo a mesma razão água/cimento (A/C), pretendeu-se determinar a natureza química, grau de funcionalização, teor e tipo de contra-ião, teor de sulfatos/sulfonatos do adjuvante e o comportamento dos superplastificantes nas pastas cimentícias, de forma a poder determinar indicadores de compatibilidade entre cimentos e superplastificantes. Constatou-se que a natureza química, o grau de funcionalização e a quantidade consumida dos superplastificantes têm influência nas pastas. Os indicadores de compatibilidade por parte dos superplastificantes parecem estar relacionados com o comprimento da cadeia lateral de éter e com o rácio CO2R/CO2 -. A alteração do momento da adição do adjuvante tem influência na compatibilidade cimento/adjuvante, sendo benéfico para os poli(étercarboxilatos) e prejudicial para o poli(naftalenossulfonato).