977 resultados para Multivariate White Noise
Resumo:
Low-copy-number molecules are involved in many functions in cells. The intrinsic fluctuations of these numbers can enable stochastic switching between multiple steady states, inducing phenotypic variability. Herein we present a theoretical and computational study based on Master Equations and Fokker-Planck and Langevin descriptions of stochastic switching for a genetic circuit of autoactivation. We show that in this circuit the intrinsic fluctuations arising from low-copy numbers, which are inherently state-dependent, drive asymmetric switching. These theoretical results are consistent with experimental data that have been reported for the bistable system of the gallactose signaling network in yeast. Our study unravels that intrinsic fluctuations, while not required to describe bistability, are fundamental to understand stochastic switching and the dynamical relative stability of multiple states.
Resumo:
OBJECTIVES: To compare physiological noise contributions in cerebellar and cerebral regions of interest in high-resolution functional magnetic resonance imaging (fMRI) data acquired at 7T, to estimate the need for physiological noise removal in cerebellar fMRI. MATERIALS AND METHODS: Signal fluctuations in high resolution (1 mm isotropic) 7T fMRI data were attributed to one of the following categories: task-induced BOLD changes, slow drift, signal changes correlated with the cardiac and respiratory cycles, signal changes related to the cardiac rate and respiratory volume per unit of time or other. [Formula: see text] values for all categories were compared across regions of interest. RESULTS: In this high-resolution data, signal fluctuations related to the phase of the cardiac cycle and cardiac rate were shown to be significant, but comparable between cerebellar and cerebral regions of interest. However, respiratory related signal fluctuations were increased in the cerebellar regions, with explained variances that were up to 80 % higher than for the primary motor cortex region. CONCLUSION: Even at a millimetre spatial resolution, significant correlations with both cardiac and respiratory RETROICOR components were found in all healthy volunteer data. Therefore, physiological noise correction is highly likely to improve the temporal signal-to-noise ratio (SNR) for cerebellar fMRI at 7T, even at high spatial resolution.
Resumo:
OBJECTIVE: White coat hypertensive is a pre-hypertensive state that has been associated with increased sympathetic drive. The objective of the study was to compare the exposure of the kidney to sympathetic nerve activity using urinary normetanephrine (UNMN) as a marker of renal sympathetic exposure in white coat hypertensive (WCH) and healthy normotensive (HN) participants. DESIGN AND METHOD: This was a double-blind randomized placebo-controlled crossover study. WCH were included if office blood pressure was >140/80 mmHg and ambulatory blood pressure <135/85 mmHg and HN if OBP was <140/90 mmHg and ABP <135/85 mmHg Participants were randomized to receive either 16 mg of candesartan or a matched placebo for one week before study day. On the study day systemic and renal hemodynamics as well as plasma norepinephrine and urinary excretion of normetanephrine (measured by LC/MS-MS were measured after one hour of baseline, one hour of lower body negative pressure and one hour of recovery period. Excretion of UNMN was expressed as the total of UNMN excreted during these three hours (cumUNMN). Paired or unpaired t-test were used for comparison. RESULTS: 25 HN and 12 WCH participants were included in the study. Mean age (±standard deviation), BMI were respectively 31.0±10.5 years and 22.0 ± 2.2 Kg/m2 in HN and 40.7±17.8 years and 26.7 ± 6.3 Kg/m2 in WCH.Table 1 Baseline mean blood pressure, plasma noradrenaline and cumulated UNMN during placebo and candesartan(Figure is included in full-text article.)Mean blood pressure was higher during placebo and candesartan in WCH compared to HN. Cumulated UNMN was higher in both groups after candesartan treatment. Cumulated UNMN was higher in WCH than in HN only after candesartan treatment. CONCLUSIONS: Urinary excretion of normetanephrine is increased in WCH compared to HN when treated with candesartan. The increased excretion of uNMN when the renin angiotensin system is blocked might reflect an increased sensitivity of WCH to stress conditions such as orthostatic stress.
Resumo:
In humans, action errors and perceptual novelty elicit activity in a shared frontostriatal brain network, allowing them to adapt their ongoing behavior to such unexpected action outcomes. Healthy and pathologic aging reduces the integrity of white matter pathways that connect individual hubs of such networks and can impair the associated cognitive functions. Here, we investigated whether structural disconnection within this network because of small-vessel disease impairs the neural processes that subserve motor slowing after errors and novelty (post-error slowing, PES; post-novel slowing, PNS). Participants with intact frontostriatal circuitry showed increased right-lateralized beta-band (12-24 Hz) synchrony between frontocentral and frontolateral electrode sites in the electroencephalogram after errors and novelty, indexing increased neural communication. Importantly, this synchrony correlated with PES and PNS across participants. Furthermore, such synchrony was reduced in participants with frontostriatal white matter damage, in line with reduced PES and PNS. The results demonstrate that behavioral change after errors and novelty result from coordinated neural activity across a frontostriatal brain network and that such cognitive control is impaired by reduced white matter integrity.
Resumo:
NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
The exhibition "Isabel Banal. Via Lactea" is part of the exhibition cycle "Blanc sota negre. Treballs des de l'imperceptible / 5" curated by Joana Masó (Centre Dona i Literatura) and Assumpta Bassas (Universitat de Barcelona). In this exhibition, the artist shows long-term and open projects exhibited on five tables. The table is one of the central elements from the beginning of her career, in relation to the creative and domestic space, but also as a double metaphor for the ground and for soil.
Resumo:
Un enregistrement de la tension artérielle ambulatoire (couvrant 24 heures) ainsi que plusieurs mesures en cabinet ont permis de classer chaque participant dans 4 catégories : normotension (tension artérielle normale au cabinet et en ambulatoire), hypertension artérielle soutenue (tension artérielle élevée au cabinet et en ambulatoire), hypertension de la blouse blanche (tension artérielle élevée au cabinet mais normale en ambulatoire) et hypertension artérielle masquée (tension artérielle élevée en ambulatoire mais normale au cabinet). Dans la littérature, la prévalence de l'hypertension artérielle masquée varie entre 8% et 48% selon la méthodologie utilisée et la population étudiée. Les personnes présentant une hypertension artérielle masquée ou une hypertension de la blouse blanche pourraient avoir un risque cardiovasculaire plus élevé que des personnes normotendues. Il est utile de déterminer les facteurs cliniques associés à l'hypertension artérielle masquée et à l'hypertension de la blouse blanche afin d'identifier les personnes à risque de développer ces conditions. Peu d'études ont examiné la proportion et les facteurs associés à l'hypertension artérielle masquée et à l'hypertension de la blouse blanche en Suisse, et aucune étude n'a été faite au niveau populationnel. Dans cette étude, nous investiguons les facteurs associés à l'hypertension masquée et à l'hypertension de la blouse blanche dans une étude populationnelle Suisse. Le Swiss Kidney Project on Genes in Hypertension (SKIPOGH) est une étude familiale transversale. La tension artérielle au cabinet et la tension artérielle ambulatoire sont mesurées par des appareils validés. Dans cette étude, nous avons défini l'hypertension artérielle masquée comme une tension artérielle au cabinet < 140/90 mmHg et une tension ambulatoire (jour) s 135/85 mmHg ; l'hypertension de la blouse blanche comme une tension artérielle au cabinet s 140/90 mmHg et une tension ambulatoire < 135/85 mmHg ; et enfin la tension artérielle à la limite supérieure de la norme au cabinet comme une tension systolique entre 130 et 139 mmHg et/ou une tension artérielle diastolique entre 85 et 89 mmHg lors de la mesure au cabinet. Nous avons utilisé une régression logistique multiple pour examiner la relation entre l'hypertension masquée et l'hypertension de la blouse blanche, d'une part, et les facteurs associés, d'autre part, en prenant en compte les corrélations familiales. Parmi les 652 participants inclus dans cette analyse, 51% sont des femmes. L'âge moyen (± écart type) est de 48 ans (± 18 ans). Les proportions de participants avec une hypertension masquée et une hypertension de la blouse blanche sont de 15.8% et de 2.6% respectivement. L'hypertension masquée est associée à l'âge (odds ratio (OR) = 1.02, p = 0.012), à une tension artérielle au cabinet à la limite supérieure de la norme (OR = 6.68, p, 0.001) et à l'obésité (OR = 3.63, p = 0.001). L'hypertension de la blouse blanche est associée à l'âge (OR = 1.07, p, 0.001) mais pas au niveau d'éducation, à l'anamnése familiale d'hypertension ou à l'activité physique. Nos données suggèrent que les médecins doivent envisager d'effectuer un enregistrement de la tension artérielle ambulatoire chez les personnes âgées avec une tension au cabinet à la limite supérieure de la norme et/ou chez les patients obèses afin de déterminer si ces individus présentent une hypertension artérielle en ambulatoire.
Resumo:
En aquesta nota es recullen noves observacions de diverses espècies de peixos exòtics obtingudes en un mostreig efectuat de febrer a maig de 2003, en catorze embassaments de Catalunya
Resumo:
The knowledge on the optics of fogbows is scarce, and their polarization characteristics have never been measured to our knowledge. To fill this gap we measured the polarization features of 16 fogbows during the Beringia 2005 Arctic polar research expedition by imaging polarimetry in the red, green and blue spectral ranges. We present here the first polarization patterns of the fogbow. In the patterns of the degree of linear polarization p, fogbows and their supernumerary bows are best visible in the red spectral range due to the least dilution of fogbow light by light scattered in air. In the patterns of the angle of polarization α fogbows are practically not discernible because their α-pattern is the same as that of the sky: the direction of polarization is perpendicular to the plane of scattering and is parallel to the arc of the bow, independently of the wavelength. Fogbows and their supernumeraries were best seen in the patterns of the polarized radiance. In these patterns the angular distance δ between the peaks of the primary and the first supernumerary and the angular width σ of the primary bow were determined along different radii from the center of the bow. δ ranged between 6.08° and 13.41° , while σ changed from 5.25° to 19.47° . Certain fogbows were relatively homogeneous, meaning small variations of δ and σ along their bows. Other fogbows were heterogeneous, possessing quite variable δ- and σ-values along their bows. This variability could be a consequence of the characteristics of the high Arctic with open waters within the ice shield resulting in the spatiotemporal change of the droplet size within the fog
Resumo:
In mathematical modeling the estimation of the model parameters is one of the most common problems. The goal is to seek parameters that fit to the measurements as well as possible. There is always error in the measurements which implies uncertainty to the model estimates. In Bayesian statistics all the unknown quantities are presented as probability distributions. If there is knowledge about parameters beforehand, it can be formulated as a prior distribution. The Bays’ rule combines the prior and the measurements to posterior distribution. Mathematical models are typically nonlinear, to produce statistics for them requires efficient sampling algorithms. In this thesis both Metropolis-Hastings (MH), Adaptive Metropolis (AM) algorithms and Gibbs sampling are introduced. In the thesis different ways to present prior distributions are introduced. The main issue is in the measurement error estimation and how to obtain prior knowledge for variance or covariance. Variance and covariance sampling is combined with the algorithms above. The examples of the hyperprior models are applied to estimation of model parameters and error in an outlier case.
Resumo:
We sometimes vividly remember things that did not happen, a phenomenon with general relevance, not only in the courtroom. It is unclear to what extent individual differences in false memories are driven by anatomical differences in memory-relevant brain regions. Here we show in humans that microstructural properties of different white matter tracts as quantified using diffusion tensor imaging are strongly correlated with true and false memory retrieval. To investigate these hypotheses, we tested a large group of participants in a version of the Deese-Roediger-McDermott paradigm (recall and recognition) and subsequently obtained diffusion tensor images. A voxel-based whole-brain level linear regression analysis was performedto relatefractional anisotropyto indices oftrue andfalse memory recall and recognition. True memory was correlated to diffusion anisotropy in the inferior longitudinal fascicle, the major connective pathway of the medial temporal lobe, whereas a greater proneness to retrieve false items was related to the superior longitudinal fascicle connecting frontoparietal structures. Our results show that individual differences in white matter microstructure underlie true and false memory performance.
Resumo:
Soitinnus: Ork.