996 resultados para Molar innervation
Resumo:
Two new, simple, rapid and reproducible spectrophotometric methods have been developed for the determination of lamotrigine (LMT) both in pure form and in its tablets. The first method (method A) is based on the formation of a colored ion-pair complex (1:1 drug/dye) of LMT with bromocresol green (BCG) at pH 5.02±0.01 and extraction of the complex into dichloromethane followed by the measurement of the yellow ion-pair complex at 410 nm. In the second (method B), the drug-dye ion-pair complex was dissolved in ethanolic potassium hydroxide and the resulting base form of the dye was measured at 620 nm. Beer's law was obeyed in the concentration range of 1.5-15 µg mL-1 and 0.5-5.0 µg mL-1 for method A and method B, respectively, and the corresponding molar absorptivity values are 1.6932 x 10(4) and 3.748 x 10(4) L mol-1cm-1. The Sandell sensitivity values are 0.0151 and 0.0068 µg cm-2 for method A and method B, respectively. The stoichiometry of the ion-pair complex formed between the dug and dye (1:1) was determined by Job's continuous variations method and the stability constant of the complex was also calculated. The proposed methods were applied successfully for the determination of drug in commercial tablets.
Resumo:
Four simple titrimetric procedures are described for the determination of lisinopril (LNP) in bulk and in pharmaceuticals based on the neutralization of basic-amino and acidic carboxylic acid groups present in LNP. Method A is based on the neutralization of basic amino groups using perchloric acid as titrant in anhydrous acetic acid medium. Method B, method C and method D are based on neutralization of carboxylic acid group using NaOH, sodium methoxide and methanolic KOH, as titrants, respectively. Method A is applicable over 2.0-20.0 mg range and the calculations are based in the molar ratio of 1:2 (LNP:HClO4). Method B, method C and method D are applicable over 2.0-20.0 mg, 1.0-10.0 mg and 5.0-15.0 mg range, respectively, and their respective molar ratios are 1:1 (LNP:NaOH), 1:2 (LNP:CH3ONa) and 1:1 (LNP:KOH). Intraday and inter day accuracy and precision of the methods were evaluated and the results showed intra- and inter-day precision less than 2.7% (RSD), and accuracy of < 2.5 % (RE). The developed methods were applied to determine LNP in tablets and the results were validated statistically by comparing the results with those of the reference method by applying the Student's t-test and F-test. The accuracy was further ascertained by recovery studies via standard addition technique. No interferences from common tablet exipients was observed.
Resumo:
A simple, sensitive and reproducible spectrophotometric method was developed for the determination of sitagliptin phosphate in bulk and in pharmaceutical formulations. The proposed method is based on condensation of the primary amino group of sitagliptin phosphate with acetyl acetone and formaldehyde producing a yellow colored product, which is measured spectrophotometrically at 430nm. The color was stable for about 1 hour. Beer's law is obeyed over a concentration range of 5-25 µg/ml. The apparent molar absorptivity and Sandell sensitivity values are 1.067 x 10(4) Lmol-1cm-1 and 0.0471 µgcm-2 respectively. All the variables were studied to optimize the reaction conditions. No interference was observed in the presence of common pharmaceutical excipients. The validity of the method was tested by analyzing sitagliptin phosphate in its pharmaceutical preparations. Good recoveries were obtained. The developed method was successfully employed for the determination of sitagliptin phosphate in various pharmaceutical preparations.
Resumo:
A simple and rapid spectrophotometric method for the determination of nevirapine is described. The method is based on the reaction of nevirapine with tetrathiocyanatocobalt(II) ion in buffer of pH 4 to form the corresponding complex. Beer's law is obeyed in the range of 0.2 - 2.0 µg mL-1 for nevirapine. The optical parameters such as molar absorptivity, Sandell's sensitivity, detection limit and quantitation limit were found to be 1.16× 10(4) Lmol-1cm-1, 2.09 X 10-3 µg cm-2, 0.073 µg mL-1 and 0.222 µg mL-1 respectively. The optimum reaction conditions and other analytical parameters were evaluated. The statistical evaluation of the method was examined by determining intra-day and inter-day precision. The proposed method has been successfully applied for the determination of nevirapine in pharmaceutical formulations.
Resumo:
A new spectrophotometric method is proposed for the assay of ranitidine hydrochloride (RNH) in bulk drug and in its dosage forms using ceric ammonium sulphate (CAS) and two dyes, malachite (MAG) green and crystal violet (CV) as reagents. The method involves the addition of a known excess of ceric ammonium sulphate to ranitidine hydrochloride in acid medium, followed by the determination of unreacted CAS by reacting with a fixed amount of malachite green or crystal violet and measuring the absorbance at 615 or 582 nm respectively against the reagent blank. The Beer's law is obeyed in the concentration range of 0.4-8.0 µg/ ml of ranitidine hydrochloride (RNH) for RNH-MAG system and 0.2-1.6µg/ml of ranitidine hydrochloride for RNH-CV system. The molar Absorptivity, Sandell's sensitivity for each system were calculated. The method has been successfully applied to the determination of ranitidine hydrochloride in pure and dosage forms.
Resumo:
O corante pararosanilina (P) é um pigmento que apresenta um relevante papel na análise de substâncias química e bactérias do tipo Gram positivo e negativo, além de outros microorganismos. Os ensaios potenciométricos de P mostraram que o corante é um ácido monoprótico e fraco (pKa= 8,78); enquanto a espectrofotometria permitiu estimar seu coeficiente de absortividade molar (ε) igual a 1,48x10(4) mol-1 cm-1 L. A curva analítica para a determinação de P apresenta linearidade entre 7,36x10-6 a 7,36x10-5 mol L-1 e a metodologia foi aplicação em amostras biológicas.
Resumo:
Um estudo espectrofotométrico de especiação das formas Cr+3, CrO4-2 e Cr2O7-2 foi realizado em amplo intervalo de pH de 2,0 a 12,0 em solução tampão Britton-Robinson. Os espectros de absorção das regiões ultra-violeta e visível são bem caracterizados, apresentando bandas nas duas regiões espectrais. A relação de absorbância versus concentração, para cada espécie química, permitiu conhecer o coeficiente de absortividade molar das entidades químicas.
Resumo:
Foram avaliados, a partir de um delineamento estatístico de um conjunto de ensaios experimentais, os efeitos (i) do tempo; (ii) da velocidade de rotação; (iii) da razão etanol:triglicerídeos; (iv) do tipo e (v) da quantidade do catalisador e (vi) da temperatura da reação de transesterificação de triglicerídeos do óleo de milho com etanol. A magnitude do efeito devido a cada fator, individualmente, afetou o rendimento, em biodiesel, da reação, na seguinte ordem decrescente de efeito (desconsiderando-se o sinal algébrico): quantidade de catalisador > razão molar > tipo de catalisador > velocidade de rotação > tempo > temperatura. Avaliaram-se, também, as interações estatísticas entre as variáveis e suas correlações com os fatores principais da reação.
Resumo:
Tillgången på traditionella biobränslen är begränsad och därför behöver man ta fram nya, tidigare outnyttjade biobränslen för att möta de uppställda CO2 emissionsmålen av EU och det ständigt ökande energibehovet. Under de senare åren har intresset riktats mot termisk energiutvinning ur olika restfraktioner och avfall. Vid produktion av fordonsbränsle ur biomassa är den fasta restprodukten ofta den största procesströmmen i produktionsanläggningen. En riktig hantering av restprodukterna skulle göra produktionen mera lönsam och mer ekologiskt hållbar. Ett alternativ är att genom förbränning producera elektricitet och/eller värme eftersom dessa restprodukter anses som CO2-neutrala. Målsättningen med den här avhandlingen var att studera förbränningsegenskaperna hos några fasta restprodukter som uppstår vid framställning av förnybara fordonsbränslen. De fyra undersökta materialen är rapskaka, palmkärnskaka, torkad drank och stabiliserat rötslam. I studien används ett stort urval av undersökningsmetoder, från laboratorieskala till fullskalig förbränning, för att identifiera de huvudsakliga utmaningarna förknippade med förbränning av restprodukterna i pannor med fluidiserad bäddteknik. Med hjälp av detaljerad bränslekarakterisering kunde restprodukterna konstateras vara en värdefull källa för värme- och elproduktion. Den kemiska sammansättningen av restprodukterna varierar stort jämfört med mera traditionellt använda biobränslen. En gemensam faktor för alla de studerade restprodukterna är en hög fosforhalt. På grund av de låga fosforkoncentrationerna i de traditionella biobränslena har grundämnet hittills inte ansetts spela någon större roll i askkemin. Experimenten visade nu att fosfor inte mera kan försummas då man studerar kemin i förbränningsprocesser, då allt flera fosforrika bränslen tränger in på energimarknaden.
Resumo:
A gravidez gemelar na qual coexistem um feto normal e uma mola completa é um evento raro. Complicações clínicas e aumento de risco de malignização são de importância nesta patologia. Este trabalho descreve um caso de diagnóstico tardio em decorrência da presença do feto. Este diagnóstico foi feito no momento da resolução da gestação e confirmado por estudo histopatológico e citometria de fluxo. A resolução da gestação foi por via transpélvica em decorrência de hemorragia uterina maciça. O seguimento pós-molar evidenciou a persistência de níveis elevados de bhCG, obtendo-se remissão completa da doença com o uso do metotrexato. À luz deste caso, discutem-se o diagnóstico, a história natural e a conduta desta rara intercorrência na clínica obstétrica.
Resumo:
Relatamos um caso de triploidia fetal não-molar detectada na 20ª semana gestacional por cordocentese realizada em razão de estudo ultra-sonográfico que revelou retardo do crescimento intra-uterino e grave oligoidrâmnio. Na 19ª semana foram verificados acentuada diminuição da subunidade beta livre da gonadotrofina coriônica humana e do estriol não-conjugado e níveis de alfa-fetoproteína normais, apontando para um risco aumentado de síndrome de Edwards. Houve morte fetal um dia após a cordocentese e a resolução do caso foi por parto vaginal induzido com misoprostol e ocitocina, sob analgesia peridural. Estudo cromossômico das células sangüíneas fetais revelou o cariótipo 69,XXX. O grave retardo do crescimento intra-uterino, a macrocefalia, constatada no estudo anatomopatológico do feto, e os níveis muito baixos de hCG e de estriol não-conjugado sugerem um caso de triploidia por diginia, fertilização de um óvulo diplóide por um espermatozóide haplóide.
Resumo:
Objetivo: definir os preditores clínicos e histopatológicos mais eficientes da evolução da mola hidatiforme completa (MHC) para tumor trofoblástico gestacional (TTG). Métodos: estudo prospectivo clínico e histopatológico de todas as portadoras de MHC, atendidas entre 1990 e 1998 no Hospital das Clínicas de Botucatu -- UNESP. A avaliação clínica pré-esvaziamento molar classificou a gravidez molar em: MHC de alto risco e MHC de baixo risco. Foram analisados os preditores clínicos para TTG, estabelecidos por Goldstein et al.¹ e por outros autores2--10. A avaliação histopatológica incluiu a determinação do diagnóstico de MHC, segundo os critérios de Szulman e Surti11, e o reconhecimento dos fatores de risco para TTG, de Ayhan et al.8. Os preditores clínicos e histopatológicos foram correlacionados com o desenvolvimento de TTG pós-molar. Resultados: em 65 portadoras de MHC, cistos do ovário maiores que 6 cm e tamanho uterino maior que 16 cm foram os preditores clínicos mais eficientes de TTG. A proliferação trofoblástica, a atipia nuclear, a necrose/hemorragia, a maturação trofoblástica e a relação cito/sinciciotrofoblasto não foram preditores significativos para TTG. A correlação entre preditor clínico e histopatológico para o desenvolvimento de TTG não foi possível porque nenhum parâmetro histopatológico foi significativo. Conclusões: mais estudos são necessários para avaliar possíveis preditores de persistência (TTG) e sua aplicação no contexto clínico das MHC. Enquanto isso, a determinação seriada de hCG sérico permanece o único indicador prognóstico seguro para TTG pós-MHC.
Resumo:
Objetivos: construir a curva de regressão do b-hCG pós-mola hidatiforme completa (MHC) com remissão espontânea e comparar com a curva de regressão pós-MHC com tumor trofoblástico gestacional (TTG). Análise comparativa da curva de regressão do b-hCG das portadoras de MHC, acompanhadas no Serviço, com a curva de regressão observada por outros autores1-3. Métodos: foi realizada avaliação clínica e laboratorial (dosagem sérica de b-hCG), na admissão e no segmento pós-molar, de todas as pacientes com MHC, atendidas entre 1990 e 1998 no Hospital das Clínicas de Botucatu - Unesp. O resultado da determinação seriada do b-hCG foi analisado em curvas log de regressão. A evolução da curva de regressão do b-hCG foi analisada e comparada em MHC com remissão espontânea e MHC com TTG numa curva log de regressão, com intervalo de confiança de 95%. A curva log de regressão do grupo de remissão espontânea foi comparada com curvas consideradas padrão1,2. Foram construídas curvas log individuais de todas as pacientes e classificadas de acordo com os quatro tipos de curva (I, II, III e IV), propostos para o seguimento pós-molar³. Resultados: 61 pacientes com MHC tiveram seguimento pós-molar completo, 50 (82%) apresentaram remissão espontânea e 11 (18%) desenvolveram TTG. No grupo de pacientes com MHC e remissão espontânea, o tempo para alcançar a normalização dos níveis do b-hCG, após o esvaziamento molar, foi até 20 semanas. As pacientes que desenvolveram TTG apresentaram desvio precoce da curva de regressão normal do b-hCG, 4 a 6 semanas após o esvaziamento molar. Nestas pacientes, a quimioterapia foi introduzida em média na 9ª semana pós-esvaziamento molar. Conclusões: a curva de regressão do b-hCG pós-MHC com remissão espontânea apresentou declínio log exponencial, semelhante ao observado por outros autores1,2, e diferente das MHC com TTG. Foram identificados três tipos de curvas de regressão do b-hCG, semelhantes aos de Goldstein³, I, II e IV, e outros dois tipos diferentes de regressão do b-hCG: V (regressão normal) e VI (regressão anormal).
Resumo:
OBJETIVO: estudar a freqüência da neoplasia trofoblástica gestacional recorrente e analisar se a evolução e o desfecho do episódio de repetição acarretam agravado risco, assim de invasão como de malignização, e se há necessidade de maior número de ciclos de quimioterapia e regimes mais agressivos. MÉTODOS: vinte e nove pacientes com mola hidatiforme recorrente foram acompanhadas e eventualmente tratadas no Centro de Neoplasia Trofoblástica Gestacional da 33ª Enfermaria da Santa Casa da Misericórdia do Rio de Janeiro, entre 1960 e 2001, representando incidência de 1,2% (29/2262). Foram revisados os prontuários médicos para determinar a idade das pacientes, o número de gravidezes, paridade, apresentação clínica e quimioterapia, caso tenha sido realizada. Um total de cinqüenta e oito episódios de neoplasia trofoblástica ocorreram nas 29 pacientes. Todos os casos tiveram comprovação histopatológica. Os cálculos estatísticos foram feitos mediante o teste de chi ² com correção de Yates e analisados pelo programa Epi-Info 2000, versão Windows, elaborado pelo Centro de Controle de Doenças de Atlanta, EUA. RESULTADOS: ocorreu mola invasora ou coriocarcinoma, no primeiro evento molar, em apenas uma paciente (1/29 - 3,4%); invasão ou malignização, entretanto, manifestou-se no segundo evento em sete pacientes (7/29 - 24,1%) [RR: 8,9; IC 95% 1,5-41; p<0,05]. CONCLUSÃO: a gravidez molar recorrente cursa com agravamento histológico e aumento na incidência de seqüela trofoblástica proliferativa, exigindo quimioterapia mais freqüente e agressiva para induzir remissão.
Resumo:
O desenvolvimento de pré-eclâmpsia ou eclâmpsia antes da 20ª semana deve levar à suspeita de mola hidatiforme. Descrevemos um caso de mola hidatiforme completa (MHC) e eclâmpsia concomitante em paciente com 20 anos que apresentava sangramento genital, anemia, tamanho uterino excessivo e cistos de ovário, associados a hipertensão arterial e proteinúria. Os níveis de b-hCG estavam elevados e a função tiroidiana, alterada. A ultra-sonografia mostrou-se compatível com MHC. Após o esvaziamento uterino apresentou cefaléia e alterações visuais, seguidas por convulsões tônico-clônicas que cessaram com sulfato de magnésio hepta-hidratado a 50%. No seguimento pós-molar foi diagnosticado tumor trofoblástico gestacional (TTG) prontamente tratado com quimioterapia. A associação de MHC e eclâmpsia determina esvaziamento uterino imediato e seguimento pós-molar rigoroso, pelo risco aumentado de desenvolvimento de TTG.