907 resultados para Micro-tomografia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The injection process of glass fibres reinforced plastics promotes the moulds surface degradation by erosion. In order to improve its wear resistance, several kinds of PVD thin hard coatings were used. It is well-known that nanostructures present a better compromise between hardness and toughness. Indeed, when the coating is constituted by a large number of ultra-thin different layers, cracks and interface troubles tend to decrease. However, it is not clear that these nanostructures present a better wear behaviour in erosion processes. In order to study its wear behaviour, a sputtered PVD nanostructured TiAlCrSiN coating was used. The substrate and film surfaces topography were analyzed by profilometry and atomic force microscopy techniques. Film adhesion to the substrate was evaluated by scratch tests. The surface hardness was measured with a Vickers micro-hardness tester. The wear resistance was evaluated by micro-abrasion with a rotating ball tribometer tests. Slurry of SiC particles in distilled water was used in order to provoke the surface abrasion. Different duration tests were performed in order to analyze the wear evolution. After these tests, the wear mechanisms developed were analyzed by scanning electron microscopy. Wear craters were measured and the wear rate was calculated and discussed. With the same purpose, coated inserts were mounted in an injection mould working with a 30% glass fibres reinforced polypropylene. After 45 000 cycles no relevant wear was registered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distinção entre miocárdio atordoado e danificado tem sido uma preocupação relevante, no cenário de um enfarte agudo do miocárdio (EAM). A avaliação da viabilidade do miocárdio, pós-enfarte, é de importância vital, no contexto clínico, principalmente numa fase inicial. Actualmente a Ressonância Magnética Cardíaca é o exame de referência para a avaliação de viabilidade do miocárdio. No entanto, é um exame com elevado custo e de difícil acesso. Estudos preliminares demonstraram potencial na utilização de imagens por Tomografia Computorizada para avaliação da área de enfarte, quer em estudos animais quer em humanos. É objectivo desta tese verificar a utilidade de um protocolo de avaliação de viabilidade do miocárdio, com base em imagens de realce tardio (RT) por Tomografia Computorizada, após um procedimento de intervenção coronária percutânea, no contexto de enfarte agudo do miocárdio com elevação do segmento ST (STEMI). Pretende-se igualmente contribuir para a análise da imagem médica do miocárdio, proporcionando métodos de quantificação do RT e software de suporte à decisão médica nesta modalidade de imagem substancialmente recente. São avaliados vários processos para a quantificação do volume de RT, incluindo um método inovador baseado na detecção automática do miocárdio normal. _E ainda proposto um algoritmo para detecção automática do grau de transmuralidade, por segmento do miocárdio, e comparado o seu grau de eficiência face ao diagnóstico médico dos mesmos exames. Apesar do reduzido número de exames utilizado para validação das técnicas descritas nesta tese, os resultados são bastante promissores e podem constituir uma mais-valia no auxilio à gestão do paciente com EAM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents a study on business micro-location behaviour as well as corresponding factors of influence, conducted in two metropolitan areas, Bucharest-Ilfov (Romania) and Greater Porto (Portugal). By business micro-location we refer to a specific site such as a building or facility, accommodating a business within a small, compact geographical area (e.g. metropolitan area). At this geographical scale, the macroeconomic layer factors were excluded, applicable when discern between regions or countries. The factors derived from location theory and previous empirical studies were surveyed, completing a cross-sectional analysis in order to find out the specific weights of the location factors and preferences, by region and by industry. Based on already established firms’ feedback on location, the specific weights were granted by each industry to the main location factors, types of areas, and types of accommodation facilities. The authors also suggested a model to integrate these results into a Geographical Information System (GIS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Doutor em Sociologia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de Estágio Apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Empreendedorismo e Internacionalização, sob orientação da Mestre Inês Veiga Pereira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A par das patologias oncológicas, as doenças do foro cardíaco, em particular a doença arterial coronária, são uma das principais causas de morte nos países industrializados, devido sobretudo, à grande incidência de enfartes do miocárdio. Uma das formas de diagnóstico e avaliação desta condição passa pela obtenção de imagens de perfusão miocárdica com radionuclídeos, realizada por Tomografia por Emissão de Positrões (PET). As soluções injectáveis de [15O]-H2O, [82Rb] e [13N]-NH3 são as mais utilizadas neste tipo de exame clínico. No Instituto de Ciências Nucleares Aplicadas à Saúde (ICNAS), a existência de um ciclotrão tem permitido a produção de uma variedade de radiofármacos, com aplicações em neurologia, oncologia e cardiologia. Recentemente, surgiu a oportunidade de iniciar exames clínicos com [13N]-NH3 para avaliação da perfusão miocárdica. É neste âmbito que surge a oportunidade do presente trabalho, pois antes da sua utilização clínica é necessário realizar a optimização da produção e a validação de todo o processo segundo as normas de Boas Práticas Radiofarmacêuticas. Após uma fase de optimização do processo, procedeu-se à avaliação dos parâmetros físico-químicos e biológicos da preparação de [13N]-NH3, de acordo com as indicações da Farmacopeia Europeia (Ph. Eur.) 8.2. De acordo com as normas farmacêuticas, foram realizados 3 lotes de produção consecutivos para validação da produção de [13N]-NH3. Os resultados mostraram um produto final límpido e ausente de cor, com valores de pH dentro do limite especificado, isto é, entre 4,5 e 8,5. A pureza química das amostras foi verificada, uma vez que relativamente ao teste colorimétrico, a tonalidade da cor da solução de [13N]-NH3 não era mais intensa que a solução de referência. As preparações foram identificadas como sendo [13N]-NH3, através dos resultados obtidos por cromatografia iónica, espectrometria de radiação gama e tempo de semi-vida. Por examinação do cromatograma obtido com a solução a ser testada, observou-se que o pico principal possuia um tempo de retenção aproximadamente igual ao pico do cromatograma obtido para a solução de referência. Além disso, o espectro de radiação gama mostrou um pico de energia 0,511 MeV e um outro adicional de 1,022 MeV para os fotões gama, característico de radionuclídeos emissores de positrões. O tempo de semi-vida manteve-se dentro do intervalo indicado, entre 9 e 11 minutos. Verificou-se, igualmente, a pureza radioquímica das amostras, correspondendo um mínimo de 99% da radioactividade total ao [13N], bem como a pureza radionuclídica, observando-se uma percentagem de impurezas inferiores a 1%, 2h após o fim da síntese. Os testes realizados para verificação da esterilidade e determinação da presença de endotoxinas bacterianas nas preparações de [13N]-NH3 apresentaram-se negativos.Os resultados obtidos contribuem, assim, para a validação do método para a produção de [13N]-NH3, uma vez que cumprem os requisitos especificados nas normas europeias, indicando a obtenção de um produto seguro e com a qualidade necessária para ser administrado em pacientes para avaliação da perfusão cardíaca por PET.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent changes in electricity markets (EMs) have been potentiating the globalization of distributed generation. With distributed generation the number of players acting in the EMs and connected to the main grid has grown, increasing the market complexity. Multi-agent simulation arises as an interesting way of analysing players’ behaviour and interactions, namely coalitions of players, as well as their effects on the market. MASCEM was developed to allow studying the market operation of several different players and MASGriP is being developed to allow the simulation of the micro and smart grid concepts in very different scenarios This paper presents a methodology based on artificial intelligence techniques (AI) for the management of a micro grid. The use of fuzzy logic is proposed for the analysis of the agent consumption elasticity, while a case based reasoning, used to predict agents’ reaction to price changes, is an interesting tool for the micro grid operator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim of the paper: The purpose of this paper is to examine human resources management practices (HRM practices) in small firms and to improve the understanding of the relationship between this kind of practices and business growth. This exploratory study is based on the resource-based view of the firm and empirical work carried out in two small firms by relating HRM practices with the firms’ results. Contribution to the literature: This is an in-depth study of HRM practices and its impact on performance growth in micro firms, isolating and controlling for most of the contextual and internal variables considered in the literature that relate HRM to growth. Firm growth analysis was broadened by the use of several dependent variables: employment growth and operational and financial performance growth. Some hypotheses for further research in identifying HRM practices in small business and its relation with firm growth are suggested. Methodology: Case study methodology was used to study two firms. The techniques used to collect data were semi-structured interviews to the owner and all the employees, unstructured observation at the firms’ facilities (during two days), entrepreneur profile definition (survey answer) and document data collection (on demographic characterization and performance results). Data was analyzed through content analysis methodology, and categories derived from the interviews’ protocols and literature. Results and implications: Results revealed that despite the firms’ organizational characteristics similarities, they differ significantly in owners’ motivation to grow, HRM practices and organizational performance and growth. Future studies should pay special attention to owner willingness to grow, to firms’ years of experience in business, to staff’s years of experience in their field of work and turnover. HRM practices in micro/small firms should be better defined and characterized. The external image of management posture relating to longitudinal financial results and growth should also be explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to analyze and compare micro-firms’ organizational culture related to organizational performance. A case study methodology was used based on four firms, competitors among themselves in the Information Technology business, focusing on the years between 2008-2013. Findings pointed out many similarities to larger firms, but some specificities of micro-firms were found and propositions were defined: clan culture predominance is related to best performing micro-firms; the configuration of several culture types seemed to be the most suitable for obtaining good organizational results, provided that they do not focus only on hierarchy and market types of culture; the market culture predominance perception by employees is associated with low job satisfaction; and, after a certain time in business, micro-firms, as do larger companies, seek to standardize and control processes. Recognizing that organizational culture is considered important to firms’ results, this study sheds some light on that important factor for micro-firms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O ensaio de dureza, e mais concretamente o ensaio de micro dureza Vickers, é no universo dos ensaios mecânicos um dos mais utilizados quer seja na indústria, no ensino ou na investigação e desenvolvimento de produto no âmbito das ciências dos materiais. Na grande maioria dos casos, a utilização deste ensaio tem como principal aplicação a caracterização ou controlo da qualidade de fabrico de materiais metálicos. Sendo um ensaio de relativa simplicidade de execução, rapidez e com resultados comparáveis e relacionáveis a outras grandezas físicas das propriedades dos materiais. Contudo, e tratando-se de um método de ensaio cuja intervenção humana é importante, na medição da indentação gerada por penetração mecânica através de um sistema ótico, não deixa de exibir algumas debilidades que daí advêm, como sendo o treino dos técnicos e respetivas acuidades visuais, fenómenos de fadiga visual que afetam os resultados ao longo de um turno de trabalho; ora estes fenómenos afetam a repetibilidade e reprodutibilidade dos resultados obtidos no ensaio. O CINFU possui um micro durómetro Vickers, cuja realização dos ensaios depende de um técnico treinado para a execução do mesmo, apresentando todas as debilidades já mencionadas e que o tornou elegível para o estudo e aplicação de uma solução alternativa. Assim, esta dissertação apresenta o desenvolvimento de uma solução alternativa ao método ótico convencional na medição de micro dureza Vickers. Utilizando programação em LabVIEW da National Instruments, juntamente com as ferramentas de visão computacional (NI Vision), o programa começa por solicitar ao técnico a seleção da câmara para aquisição da imagem digital acoplada ao micro durómetro, seleção do método de ensaio (Força de ensaio); posteriormente o programa efetua o tratamento da imagem (aplicação de filtros para eliminação do ruído de fundo da imagem original), segue-se, por indicação do operador, a zona de interesse (ROI) e por sua vez são identificadas automaticamente os vértices da calote e respetivas distâncias das diagonais geradas concluindo, após aceitação das mesmas, com o respetivo cálculo de micro dureza resultante. Para validação dos resultados foram utilizados blocos-padrão de dureza certificada (CRM), cujos resultados foram satisfatórios, tendo-se obtido um elevado nível de exatidão nas medições efetuadas. Por fim, desenvolveu-se uma folha de cálculo em Excel com a determinação da incerteza associada às medições de micro dureza Vickers. Foram então comparados os resultados nas duas metodologias possíveis, pelo método ótico convencional e pela utilização das ferramentas de visão computacional, tendo-se obtido bons resultados com a solução proposta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação foi desenvolvida com colaboração do Campus Tecnológico e Nuclear e do Hospital de São José

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Probing micro-/nano-sized surface conformations, which are ubiquitous in biological systems, by using liquid crystal droplets, which change their ordering and optical appearance in response to the presence of more than ten times smaller cellulose based micro/nano fibers, might find new uses in a range of biological environments and sensors. Previous studies indicate that electrospun micro/nano cellulosic fibers produced from liquid crystalline solutions could present a twisted form [1]. In this work, we study the structures of nematic liquid crystal droplets threaded by cellulose fibers prepared from liquid crystalline and isotropic solutions as well as droplets pierced by spider-made fibers [2]. Planar anchoring at the fibers and planar and homeotropic at the drop surfaces allowed probing cellulose fibers different helical structures as well as aligned filaments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As Micro e Pequenas Empresas (MPE) possuem na sua essência recursos limitados. Raramente possuem um Sistema Integrado de Gestão (SIG) que lhes permita gerir o seu negócio de forma transversal e que mapeie todos os processos da empresa. Devido ao número reduzido de colaboradores, não dispõem internamente alguns serviços. O seu espaço de mercado é em geral limitado. As suas competências específicas raramente permitem apresentar uma oferta global. Por serem pequenas, não têm força negocial perante os seus fornecedores e eventuais parceiros estratégicos. A Arquitetura de Sistemas de Informação (ASI) permite representar e mapear os diversos aspetos da gestão das empresas e alinhar as Tecnologias de Informação e Comunicação (TIC) com as necessidades destas empresas. Este trabalho pretende apresentar e descrever uma Macro Arquitetura para a construção de SIG, orientados para as MPE, e que inclua um conjunto de serviços integrados numa única plataforma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - O presente trabalho pretende centrar-se no estudo da Segurança do Doente e das boas práticas de Consentimento Esclarecido na realização de exames de Tomografia Computorizada. Nos dias de hoje, a assinatura do documento de Consentimento Esclarecido tem-se mostrado um ato banal, sem a merecida atenção que entidades de saúde, Médicos e Técnicos de Radiologia lhe deviam conceder, uma vez que os Eventos Adversos, aquando da realização de uma TC com Meio de Contraste, poderão ser vários e complicados; por outro lado, o doente muitas vezes não está preparado nem devidamente informado sobre os seus efeitos e as medidas necessárias que deverão ser acionadas para os combater. A necessidade da veiculação de uma informação capaz, de uma elucidação total para o doente pôr em prática a sua autonomia, fruto da consciência que tem dos factos, revela-se fundamental, mas para que tal aconteça é urgente ultrapassar obstáculos respeitantes às práticas profissionais de entidades de saúde, Médicos e Técnicos de Radiologia, assim como aspetos sociais, linguísticos, idade, vulnerabilidade individual, entre outros. Neste contexto, a apresentação de boas práticas de Consentimento Esclarecido revela-se de extrema importância para o desenvolvimento desta dissertação. Para consubstanciar as ideias a desenvolver, para além da pesquisa bibliográfica, revelou-se importante a recolha de dados através de uma entrevista e de um inquérito a elementos que participam neste processo, nomeadamente, doentes, Médicos e Técnicos de Radiologia e, posteriormente, uma análise dos conteúdos dos resultados obtidos e a sua integração nos princípios teóricos do estudo.