759 resultados para Mechanical Joining


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The effectiveness of noninvasive positive-pressure ventilation in preventing reintubation due to respiratory failure in children remains uncertain. A pilot study was designed to evaluate the frequency of extubation failure, develop a randomization approach, and analyze the feasibility of a powered randomized trial to compare noninvasive positive-pressure ventilation and standard oxygen therapy post extubation for preventing reintubation within 48 hours in children with respiratory failure.Design: Prospective pilot study.Setting: PICU at a university-affiliated hospital.Patients: Children aged between 28 days and 3 years undergoing invasive mechanical ventilation for greater than or equal to 48 hours with respiratory failure after programmed extubation.Interventions: Patients were prospectively enrolled and randomly assigned into noninvasive positive-pressure ventilation group and inhaled oxygen group after programmed extubation from May 2012 to May 2013.Measurements and Main Results: Length of stay in PICU and hospital, oxygenation index, blood gas before and after tracheal extubation, failure and reason for tracheal extubation, complications, mechanical ventilation variables before tracheal extubation, arterial blood gas, and respiratory and heart rates before and 1 hour after tracheal extubation were analyzed. One hundred eight patients were included (noninvasive positive-pressure ventilation group, n = 55 and inhaled oxygen group, n = 53), with 66 exclusions. Groups did not significantly differ for gender, age, disease severity, Pediatric Risk of Mortality at admission, tracheal intubation, and mechanical ventilation indications. There was no statistically significant difference in reintubation rate (noninvasive positive-pressure ventilation group, 9.1%; inhaled oxygen group, 11.3%; p > 0.05) and length of stay (days) in PICU (noninvasive positive-pressure ventilation group, 3 [116]; inhaled oxygen group, 2 [1-25]; p > 0.05) or hospital (noninvasive positive-pressure ventilation group, 19 [7-141]; inhaled oxygen group, 17 [8-80]).Conclusions: The study indicates that a larger randomized trial comparing noninvasive positive-pressure ventilation and standard oxygen therapy in children with respiratory failure is feasible, providing a basis for a future trial in this setting. No differences were seen between groups. The number of excluded patients was high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of the insertion technique for resin cement and mechanical cycling on the bond strength between fiber posts and root dentin.Materials and Methods: Sixty-four single-rooted bovine teeth were endodontically prepared to receive glass-fiber posts. The insertion of cement into the root canal was performed using one of the following techniques: POS, insertion with the post; LEN, the use of a lentulo-type drill; EXP, insertion with a straight-tip explorer; or CEN, the use of a Centrix syringe. Half of the specimens were mechanically cycled. All specimens were sectioned into slices of 1.8 mm for the push-out test and 0.5 mm for analysis of the cement layer quality.Results: The insertion technique affected the interaction between factors (bond strength and mechanical cycling; p < 0.0001). Insertion of the Centrix syringe after mechanical cycling showed the highest bond values (13.6 +/- 3.2 MPa). Group-to-group comparisons for baseline and cycled conditions indicated that mechanical cycling significantly influenced the bond strength (p < 0.0001) of the POS and CEN groups. The quality of the cement layer did not differ between the techniques when evaluated in the middle (p = 0.0612) and cervical (p = 0.1119) regions, but did differ in the apical region (p = 0.0097), where the CEN group had better layer quality for the two conditions tested (baseline and cycled).Conclusion: The use of the Centrix syringe improved the homogeneity of the cement layer, reducing the defects in the layer and increasing adhesive strength values to dentin, even after mechanical cycling.