892 resultados para Location precision


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water held in the unsaturated zone is important for agriculture and construction and is replenished by infiltrating rainwater. Monitoring the soil water content of clay soils using ground-penetrating radar (GPR) has not been researched, as clay soils cause attenuation of GPR signal. In this study, GPR common-midpoint soundings (CMPs) are used in the clayey soils of the Miller Run floodplain to monitor changes in the soil water content (SWC) before and after rainfall events. GPR accomplishes this task because increases in water content will increase the dielectric constant of the subsurface material, and decrease the velocity of the GPR wave. Using an empirical relationship between dielectric constant and SWC, the Topp relation, we are able to calculate a SWC from these velocity measurements. Non-invasive electromagnetics, resistivity, and seismic were performed, and from these surveys, the layering at the field site was delineated. EM characterized the horizontal variation of the soil, allowing us to target the most clay rich area. At the CMP location, resistivity indicates the vertical structure of the subsurface consists of a 40 cm thick layer with a resistivity of 100 ohm*m. Between 40 cm and 1.5 m is a layer with a resistivity of 40 ohm*m. The thickness estimates were confirmed with invasive auger and trenching methods away from the CMP location. GPR CMPs were collected relative to a July 2013 and September 2013 storm. The velocity observations from the CMPs had a precision of +/- 0.001 m/ns as assessed by repeat analysis. In the case of both storms, the GPR data showed the expected relationship between the rainstorms and calculated SWC, with the SWC increasing sharply after the rainstorm and decreasing as time passed. We compared these data to auger core samples collected at the same time as the CMPs were taken, and the volumetric analysis of the cores confirmed the trend seen in the GPR, with SWC values between 3 and 5 percent lower than the GPR estimates. Our data shows that we can, with good precision, monitor changes in the SWC of conductive soils in response to rainfall events, despite the attenuation induced by the clay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laurentide glaciation during the early Pleistocene (~970 ka) dammed the southeast-flowing West Branch of the Susquehanna River (WBSR), scouring bedrock and creating 100-km-long glacial Lake Lesley near the Great Bend at Muncy, Pennsylvania (Ramage et al., 1998). Local drill logs and well data indicate that subsequent paleo-outwash floods and modern fluvial processes have deposited as much as 30 meters of alluvium in this area, but little is known about the valley fill architecture and the bedrock-alluvium interface. By gaining a greater understanding of the bedrock-alluvium interface the project will not only supplement existing depth to bedrock information, but also provide information pertinent to the evolution of the Muncy Valley landscape. This project determined if variations in the thickness of the valley fill were detectable using micro-gravity techniques to map the bedrock-alluvium interface. The gravity method was deemed appropriate due to scale of the study area (~30 km2), ease of operation by a single person, and the available geophysical equipment. A LaCoste and Romberg Gravitron unit was used to collect gravitational field readings at 49 locations over 5 transects across the Muncy Creek and Susquehanna River valleys (approximately 30 km2), with at least two gravity base stations per transect. Precise latitude, longitude and ground surface elevation at each location were measured using an OPUS corrected Trimble RTK-GPS unit. Base stations were chosen based on ease of access due to the necessity of repeat measurements. Gravity measurement locations were selected and marked to provide easy access and repeat measurements. The gravimeter was returned to a base station within every two hours and a looping procedure was used to determine drift and maximize confidence in the gravity measurements. A two-minute calibration reading at each station was used to minimize any tares in the data. The Gravitron digitally recorded finite impulse response filtered gravity measurements every 20 seconds at each station. A measurement period of 15 minutes was used for each base station occupation and a minimum of 5 minutes at all other locations. Longer or multiple measurements were utilized at some sites if drift or other externalities (i.e. train or truck traffic) were effecting readings. Average, median, standard deviation and 95% confidence interval were calculated for each station. Tidal, drift, latitude, free-air, Bouguer and terrain corrections were then applied. The results show that the gravitational field decreases as alluvium thickness increases across the axes of the Susquehanna River and Muncy Creek valleys. However, the location of the gravity low does not correspond with the present-day location of the West Branch of the Susquehanna River (WBSR), suggesting that the WBSR may have been constrained along Bald Eagle Mountain by a glacial lobe originating from the Muncy Creek Valley to the northeast. Using a 3-D inversion model, the topography of the bedrock-alluvium interface was determined over the extent of the study area using a density contrast of -0.8 g/cm3. Our results are consistent with the bedrock geometry of the area, and provide a low-cost, non-invasive and efficient method for exploring the subsurface and for supplementing existing well data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Location-awareness indoors will be an inseparable feature of mobile services/applications in future wireless networks. Its current ubiquitous availability is still obstructed by technological challenges and privacy issues. We propose an innovative approach towards the concept of indoor positioning with main goal to develop a system that is self-learning and able to adapt to various radio propagation environments. The approach combines estimation of propagation conditions, subsequent appropriate channel modelling and optimisation feedback to the used positioning algorithm. Main advantages of the proposal are decreased system set-up effort, automatic re-calibration and increased precision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of many genetic studies is to locate the genomic regions (called quantitative trait loci, QTLs) that contribute to variation in a quantitative trait (such as body weight). Confidence intervals for the locations of QTLs are particularly important for the design of further experiments to identify the gene or genes responsible for the effect. Likelihood support intervals are the most widely used method to obtain confidence intervals for QTL location, but the non-parametric bootstrap has also been recommended. Through extensive computer simulation, we show that bootstrap confidence intervals are poorly behaved and so should not be used in this context. The profile likelihood (or LOD curve) for QTL location has a tendency to peak at genetic markers, and so the distribution of the maximum likelihood estimate (MLE) of QTL location has the unusual feature of point masses at genetic markers; this contributes to the poor behavior of the bootstrap. Likelihood support intervals and approximate Bayes credible intervals, on the other hand, are shown to behave appropriately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasingly, regression models are used when residuals are spatially correlated. Prominent examples include studies in environmental epidemiology to understand the chronic health effects of pollutants. I consider the effects of residual spatial structure on the bias and precision of regression coefficients, developing a simple framework in which to understand the key issues and derive informative analytic results. When the spatial residual is induced by an unmeasured confounder, regression models with spatial random effects and closely-related models such as kriging and penalized splines are biased, even when the residual variance components are known. Analytic and simulation results show how the bias depends on the spatial scales of the covariate and the residual; bias is reduced only when there is variation in the covariate at a scale smaller than the scale of the unmeasured confounding. I also discuss how the scales of the residual and the covariate affect efficiency and uncertainty estimation when the residuals can be considered independent of the covariate. In an application on the association between black carbon particulate matter air pollution and birth weight, controlling for large-scale spatial variation appears to reduce bias from unmeasured confounders, while increasing uncertainty in the estimated pollution effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The melanocortin-4 receptor (MC4R) is expressed in the hypothalamus and regulates energy intake and body weight. In silico screening of the canine chromosome 1 sequence and a comparison with the porcine MC4R sequence by BLAST were performed. The nucleotide sequence of the whole coding region and 3'- and 5'-flanking regions of the dog (1214 bp) and red fox (1177 bp) MC4R gene was established and high conservation of the nucleotide sequences was revealed (99%). Five sets of PCR primers were designed and a search for polymorphism was performed by the SSCP technique in a group of 31 dogs representing nineteen breeds and 35 farm red foxes. Sequencing of DNA fragments, representing the identified SSCP patterns, revealed three single nucleotide polymorphisms (including a missense one) in dogs and four silent SNPs in red foxes. An average SNP frequency was approx. 1/400 bp in the dog and 1/300 bp in the red fox. We mapped the MC4R gene by FISH to the canine chromosome 1 (CFA1q1.1) and to the red fox chromosome 5 (VVU5p1.2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pleomorphic adenomas primarily arise in the major salivary glands, especially in the parotid. The most common area is the lower pole superficial to the plane of the facial nerve. In this report, a pleomorphic adenoma in an atypical location--the region of the temporomandibular joint (TMJ)--is presented. The tumor was solitary, closely attached to the capsule of the TMJ and superior to the parotid gland, with clear demarcation. Clinically, the tumor resembled TMJ pathology, but MRI examination led to diagnosis of a benign tumor attached to the TMJ. This report shows that pleomorphic adenoma can be a possible diagnosis for lesions at the joint capsule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.