924 resultados para Load forecast
Resumo:
Patients infected with the human immunodeficiency virus (HIV) are at higher risk of developing Epstein-Barr Virus (EBV)-associated lymphomas. The usefulness of monitoring EBV in peripheral blood mononuclear cells (PBMCs) of patients infected with HIV has not been established. The aim of this study was to evaluate the EBV viral load in PBMCs, the frequency of viral genotypes, and the presence of the 30-bp deletion in the BNLF-1 gene. DNA samples from 156 patients attending the HIV/AIDS Day Clinic at Botucatu School of Medicine, Sao Paulo State University were evaluated. The EBV viral load was detectable by real time PCR in 123/156 (78.8%) cases and was higher in patients not receiving antiretroviral treatment or under therapeutic failure than in patients under successful highly active antiretroviral therapy (HAART) (P=0.0076). Overall, the profile of patients with high EBV viral load included elevated HIV viremia (P=0.0005), longer time of HIV diagnosis (P=0.0026), and increased levels of T CD8 + lymphocytes (P=0.0159). The successful amplification of the EBNA-2 gene by nested-PCR was achieved in 95 of 123 (77.2%) cases, of which 75.8% were EBV-1, 9.5% EBV-2, and 14.7% were co-infected with both EBV-1 and -2. The analysis of the BNLF-1 gene was possible in 99 of 123 (80.5%) cases, of which 50.5% had the 30-bp deletion. EBV-1 was more common than EBV-2, which may reflect the fact that the cohort was predominantly Caucasian and heterosexual. J. Med. Virol. 85:2110-2118, 2013. © 2013 Wiley Periodicals, Inc.
Resumo:
Includes bibliography
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Host genetic factors play an important role in mediating resistance to HIV-1 infection and may modify the course of infection. HLA-B alleles (Bw4 epitope; B*27 and B*57) as well as killer cell immunoglobulin-like receptors have been associated with slow progression of HIV-1 infection. OBJECTIVE: To evaluate the association between serological epitopes HLA-Bw4 and HLA-Bw6 and prognostic markers in AIDS. METHODS: 147 HIV-infected individuals in Bahia, Northeast Brazil, were genotyped for HLA class I locus. HLA class I genotyping was performed by hybridization with sequence-specific oligonucleotide probes following amplification of the corresponding HLA-A, HLA-B and HLA-C genes. Statistical analysis was performed using Fisher's exact and ANOVA tests for categorical and continuous variables, respectively. RESULTS: We detected a significant association (χ2 = 4.856; p = 0.018) between the presence of HLA-Bw4 and low levels of viremia. Eighteen out of the 147 HIV-infected individuals presented viremia <1,800 copies/mL and 129 presented viremia > 2,000 copies/mL. Ninety and four percent (17/18) of all individuals with viremia < 1,800 copies/mL carried HLA-Bw4, compared to 67.4% (87/129) of individuals with viremia > 2,000 copies/mL. Additionally, we found a significantly higher frequency of B*57 (OR = 13.94; 95% CI = 4.19-46.38; p < 0.0001) and Cw*18 (OR = 16.15; 95% CI = 3.46-75.43; p < 0.0001) alleles, favoring the group with lower viremia levels, in comparison with those with higher viral load. CONCLUSION: HLA-Bw4-B*57 and Cw*18 alleles are associated with lower level of viral load in HIV-infected Brazilian patients. These findings may help us in understanding the determinants of HIV evolution in Brazilian patients, as well as in providing important information on immune response correlates of protection for such population.
Resumo:
This paper proposes an approach to load characterization and revenue metering, which accounts for the influence of supply deterioration and line impedance. It makes use of the Conservative Power Theory and aims at characterizing the load from the measurements done at the point of common coupling. Despite the inherent limitations of a single-point measurement, the proposed methodology enables evaluation of power terms, which clarify the effects of reactivity, asymmetry and distortion, and attempts to depurate the power consumption accounted to the load from those terms deriving from supply nonidealities.
Resumo:
Environmental aspects have been acknowledged as an important issue in decision making at any field during the last two decades. There are several available methodologies able to assess the environmental burden, among which the Ecological Footprint has been widely used due to its easy-to-understand final indicator. However, its theoretical base has been target of some criticisms about the inadequate representation of the sustainability concept by its final indicator. In a parallel way, efforts have been made to use the theoretical strength of the Emergy Accounting to obtain an index similar to that supplied by the Ecological Footprint. Focusing on these aspects, this work assesses the support area (SA) index for Brazilian sugarcane and American corn crop through four different approaches: Embodied Energy Analysis (SA(EE)), Ecological Footprint (SA(EF)), Renewable Empower Density (SA(R)), and Emergy Net Primary Productivity (SA(NPP)). Results indicate that the load on environment varies accordingly to the methodology considered for its calculation, in which emergy approach showed the higher values. Focusing on crops comparison, the load by producing both crops are similar with an average of 0.04 ha obtained by SA(EE), 1.86 ha by SA(EF), 4.24 ha by SA(R), and 4.32 ha by SA(NPP). Discussion indicates that support area calculated using Emergy Accounting is more eligible to represent the load on the environment due to its global scale view. Nevertheless, each methodology has its contribution depending of the study objectives, but it is important to consider the real meaning and the scope of each one. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Polymeric insulation is an increasing tendency in projects and maintenance of electrical networks for power distribution and transmission. Electrical power devices (e. g., insulators and surge arresters) developed by using polymeric insulation presents many advantages compared to the prior power components using ceramic insulation, such as: a better performance under high pollution environment; high hydrophobicity; high resistance to mechanical, electrical and chemical stresses. The practice with silicone insulators in polluted environments has shown that the ideal performance is directly related to insulator design and polymer formulation. One of the most common misunderstandings in the design of silicone compounds for insulators is the amount of inorganic load used in their formulation. This paper attempts to clarify how the variation of the inorganic load amount affects physicochemical characteristics of different silicone compounds. The physicochemical evaluation is performed from several measurements, such as: density, hardness, elongation, tensile strength. In addition, the evaluation of the physicochemical structure is carried out using infrared test and scanning electronic microscopy (SEM). The electrical analysis is performed from the electric tracking wheel and erosion test, in agreement with the recommendation of the International Electrotechnical Commission (IEC). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Among all predictive maintenance techniques the oil analysis and vibration analysis are the most important for monitoring some mechanical systems. The integration of these techniques has potential to improve industrial maintenance practices and provide a better economic gain for industries. To study the integration of these two techniques, a test rig was set up to obtain an extreme working condition for the worm reducer used in this paper. The test rig was composed by a motor connected to a reducer through a flexible coupling and with an unbalanced load. The analysis of the results carried out by using a sample of the oil recommended by the manufacturer in extreme conditions, and using liquid contaminant is presented. From the results it was observed that if there is an abnormal instantaneous load in a system, the subsequent vibration analysis may not perceive what occurred if there was no permanent damage, which is not the case with the lubricant analysis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate the survival rate, success rate, load to fracture, and finite element analysis (FEA) of maxillary central incisors and canines restored using ceramic veneers and varying preparation designs.Methods and Materials: Thirty human maxillary central incisors and 30 canines were allocated to the following four groups (n=15) based on the preparation design and type of tooth: Gr1 = central incisor with a conservative preparation; Gr2 = central incisor with a conventional preparation with palatal chamfer; Gr3 = canine with a conservative preparation; Gr4 = canine with a conventional preparation with palatal chamfer. Ceramic veneers (lithium disilicate) were fabricated and adhesively cemented (Variolink Veneer). The specimens were subjected to 4 x 106 mechanical cycles and evaluated at every 500,000 cycles to detect failures. Specimens that survived were subjected to a load to fracture test. Bidimensional models were modeled (Rhinoceros 4.0) and evaluated (MSC.Patrans 2005r2 and MSC.Marc 2005r2) on the basis of their maximum principal stress (MPS) values. Survival rate values were analyzed using the Kaplan-Meier test (alpha = 0.05) and load to fracture values were analyzed using the Student t-test (alpha = 0.05).Results: All groups showed 100% survival rates. The Student t-test did not show any difference between the groups for load to fracture. FEA showed higher MPS values in the specimens restored using veneers with conventional preparation design with palatal chamfer.Conclusion: Preparation design did not affect the fracture load of canines and central incisors, but the veneers with conventional preparation design with palatal chamfer exhibited a tendency to generate higher MPS values.