968 resultados para Lancaster Institution, Southwark, Eng.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maintaining the ecosystem is one of the main concerns in this modern age. With the fear of ever-increasing global warming, the UK is one of the key players to participate actively in taking measures to slow down at least its phenomenal rate. As an ingredient to this process, the Springer vehicle was designed and developed for environmental monitoring and pollutant tracking. This special issue paper highlighted the Springer hardware and software architecture including various navigational sensors, a speed controller, and an environmental monitoring unit. In addition, details regarding the modelling of the vessel were outlined based mainly on experimental data. The formulation of a fault tolerant multi-sensor data fusion technique was also presented. Moreover, control strategy based on a linear quadratic Gaussian controller was developed and simulated on the Springer model.
Gaussian controller is developed and simulated on the Springer model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Closed-form design equations for the operation of a class-E amplifier for zero switch voltage slope and arbitrary duty cycle are derived. This approach allows an additional degree of freedom in the design of class-E amplifiers which are normally designed for 50 duty ratio. The analysis developed permits the selection of non-unique solutions where amplifier efficiency is theoretically 100 but power output capability is less than that the 50 duty ratio case would permit. To facilitate comparison between 50 (optimal) and non-50 (suboptimal) duty ratio cases, each important amplifier parameter is normalised to its corresponding optimum operation value. It is shown that by choosing a non-50 suboptimal solution, the operating frequency of a class-E amplifier can be extended. In addition, it is shown that by operating the amplifier in the suboptimal regime, other amplifier parameters, for example, transistor output capacitance or peak switch voltage, can be included along with the standard specification criteria of output power, DC supply voltage and operating frequency as additional input design specifications. Suboptimum class-E operation may have potential advantages for monolithic microwave integrated circuit realisation as lower inductance values (lower series resistance, higher self-resonance frequency, less area) may be required when compared with the results obtained for optimal class-E amplifier synthesis. The theoretical analysis conducted here was verified by harmonic balance simulation, with excellent agreement between both methods. © The Institution of Engineering and Technology 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design procedure, fabrication and measurement of a Class-E power amplifier with excellent second- and third-harmonic suppression levels are presented. A simplified design technique offering compact physical layout is proposed. With a 1.2 mm gate-width GaAs MESFET as a switching device, the amplifier is capable of delivering 19.2 dBm output power at 2.41 GHz, achieves peak PAE of 60% and drain efficiency of 69%, and exhibits 9 dB power gain when operated from a 3 V DC supply voltage. When compared to the classical Class-E two-harmonic termination amplifier, the Class-E amplifier employing three-harmonic terminations has more than 10% higher drain efficiency and 23 dB better third-harmonic suppression level. Experimental results are presented and good agreement with simulation is obtained. Further, to verify the practical implementation in communication systems, the Bluetooth-standard GFSK modulated signal is applied to both two- and three-harmonic amplifiers. The measured RMS FSK deviation error and RMS magnitude error were, for the three-harmonic case, 1.01 kHz and 0.122%, respectively, and, for the two-harmonic case, 1.09 kHz and 0.133%. © 2007 The Institution of Engineering and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1878, one of Britain's largest banks, the City of Glasgow Bank, collapsed, leaving a huge deficit between its assets and liabilities. As this bank, similar to many other contemporary British banks, had unlimited liability, its failure was accompanied by the bankruptcy of the vast majority of its stockholders. It is generally believed that the collapse of this depository institution revealed the extent to which ownership in large joint-stock banks had been diffused to investors of very modest means. It is also believed that the failure resulted in bank shareholders dumping their shares unto the market. Our evidence, garnered from ownership records, trading data, and stock prices, offers no support for these widely held beliefs. © 2007 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eng-genes concept involves the use of fundamental known system functions as activation functions in a neural model to create a 'grey-box' neural network. One of the main issues in eng-genes modelling is to produce a parsimonious model given a model construction criterion. The challenges are that (1) the eng-genes model in most cases is a heterogenous network consisting of more than one type of nonlinear basis functions, and each basis function may have different set of parameters to be optimised; (2) the number of hidden nodes has to be chosen based on a model selection criterion. This is a mixed integer hard problem and this paper investigates the use of a forward selection algorithm to optimise both the network structure and the parameters of the system-derived activation functions. Results are included from case studies performed on a simulated continuously stirred tank reactor process, and using actual data from a pH neutralisation plant. The resulting eng-genes networks demonstrate superior simulation performance and transparency over a range of network sizes when compared to conventional neural models. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Key to various bone substitute scaffold production techniques is the development of free-flowing ceramic slurry with optimum theological properties. The aim is to achieve a colloidal suspension with as high a solid content as possible while maintaining a low viscosity which easily penetrates the pores of relevant sacrificial templates. The following investigation describes the optimization of a hydroxyapatite slip and demonstrates its potential application in scaffold production. Using predominantly spherical particles of hydroxyapatite of between 0.82 mu m and 16.2 mu m, coupled with a 2 wt % addition of the anionic polyelectrolyte, ammonium polyacrylate, an 80 wt % (55.9 vol %) hydroxyapatite solid loaded slip with a viscosity of approximately 126 mPa s has been developed. Its ability to infiltrate and replicate porous preforms has been shown using polyurethane foam. The enhanced particle packing achieved has allowed for the production of scaffolds with highly dense and uniform grain structures. The results represent a significant improvement in current slurry production techniques and can be utilized to develop high-density ceramic bone substitute scaffolds.