905 resultados para Joint Configuration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strategic management of information plays a fundamental role in the organizational management process since the decision-making process depend on the need for survival in a highly competitive market. Companies are constantly concerned about information transparency and good practices of corporate governance (CG) which, in turn, directs relations between the controlling power of the company and investors. In this context, this article presents the relationship between the disclosing of information of joint-stock companies by means of using XBRL, the open data model adopted by the Brazilian government, a model that boosted the publication of Information Access Law (Lei de Acesso à Informação), nº 12,527 of 18 November 2011. Information access should be permeated by a mediation policy in order to subsidize the knowledge construction and decision-making of investors. The XBRL is the main model for the publishing of financial information. The use of XBRL by means of new semantic standard created for Linked Data, strengthens the information dissemination, as well as creates analysis mechanisms and cross-referencing of data with different open databases available on the Internet, providing added value to the data/information accessed by civil society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on an unmodeled, all-sky search for gravitational waves from merging intermediate mass black hole binaries (IMBHB). The search was performed on data from the second joint science run of the LIGO and Virgo detectors (July 2009-October 2010) and was sensitive to IMBHBs with a range up to similar to 200 Mpc, averaged over the possible sky positions and inclinations of the binaries with respect to the line of sight. No significant candidate was found. Upper limits on the coalescence-rate density of nonspinning IMBHBs with total masses between 100 and 450 M-circle dot and mass ratios between 0.25 and 1 were placed by combining this analysis with an analogous search performed on data from the first LIGO-Virgo joint science run (November 2005-October 2007). The most stringent limit was set for systems consisting of two 88 M-circle dot black holes and is equal to 0.12 Mpc(-3) Myr(-1) at the 90% confidence level. This paper also presents the first estimate, for the case of an unmodeled analysis, of the impact on the search range of IMBHB spin configurations: the visible volume for IMBHBs with nonspinning components is roughly doubled for a population of IMBHBs with spins aligned with the binary's orbital angular momentum and uniformly distributed in the dimensionless spin parameter up to 0.8, whereas an analogous population with antialigned spins decreases the visible volume by similar to 20%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sacroiliac joint (SIJ) pain is responsible for up to 40% of all cases of lumbar back pain. Objective Report the long-term efficacy of radiofrequency denervation for sacroiliac joint pain at six, twelve and eighteen months. Method Third-two adults’ patients with sacroiliac join pain diagnosis were included for a prospective study. Primary outcome measure was pain intensity on the Numeric Rating Scale (NRS). Secondary outcome measure was Patient Global Impression of Change Scale (PGIC). Results Short-term pain relief was observed, with the mean NRS pain score decreasing from 7.7 ± 1.8 at baseline to 2.8 ± 1.2 at one month and to 3.1 ± 1.9 at six months post-procedure (p < 0.001). Long-term pain relief was sustained at twelve and eighteen months post-procedure, with NRS pain remaining at 3.4 ± 2.1 and 4.0 ± 2.7, respectively. Conclusion Radiofrequency denervation of the SIJ can significantly reduce pain in selected patients with sacroiliac syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this systematic review was to compare straight-line and offset implant configurations for three-element implant-retained prostheses. Materials and Methods: Two independent reviewers conducted a review on PubMed/Medline, EMBASE, and Cochrane Library for studies published in English, from January 1, 1995 to January 17, 2014. A systematic review was conducted following the PRISMA statement. All relevant titles were selected according to inclusion/exclusion criteria. From this pool of titles, abstracts and full texts were reviewed. Results: A total of 6080 titles were identified with the initial search. Twenty-one were selected based on title and abstract. Of these, after discussion and complete reading, 12 studies were selected according to the inclusion and exclusion criteria, all of which were in vitro studies. Conclusions: A systematic review of the current literature showed only in vitro evidence that there is no consensus on the advantage of using an offset configuration implant compared to those in straight-line configuration, even though some studies present a slight improvement of bone stress distribution when an offset implant is under oblique loading (PICO).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structured AbstractObjectivesTo investigate the 3D morphological variations in 169 temporomandibular ioint (TMJ) condyles, using novel imaging statistical modeling approaches.Setting and sample populationThe Department of Orthodontics and Pediatric Dentistry at the University of Michigan. Cone beam CT scans were acquired from 69 subjects with long-term TMJ osteoarthritis (OA, mean age 39.115.7years), 15 subjects at initial consult diagnosis of OA (mean age 44.914.8years), and seven healthy controls (mean age 4312.4years).Materials and methods3D surface models of the condyles were constructed, and homologous correspondent points on each model were established. The statistical framework included Direction-Projection-Permutation (DiProPerm) for testing statistical significance of the differences between healthy controls and the OA groups determined by clinical and radiographic diagnoses.ResultsCondylar morphology in OA and healthy subjects varied widely with categorization from mild to severe bone degeneration or overgrowth. DiProPerm statistics supported a significant difference between the healthy control group and the initial diagnosis of OA group (t=6.6, empirical p-value=0.006) and between healthy and long-term diagnosis of OA group (t=7.2, empirical p-value=0). Compared with healthy controls, the average condyle in OA subjects was significantly smaller in all dimensions, except its anterior surface, even in subjects with initial diagnosis of OA.ConclusionThis new statistical modeling of condylar morphology allows the development of more targeted classifications of this condition than previously possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In uncemented Ti6Al4V hip implants, the bone-stem interface is subjected to cyclic loading motion driven by the daily activities of the patients, which may lead to the complete failure of the implant in the long term. It may also compromise the proliferation and differentiation processes of osteoblastic cells (bone-forming cells). The main objective of this work is to approach for the first time the role of these organic materials on the bio-tribocorrosion mechanisms of cultured Ti6Al4V alloys. The colonized materials with MG63 osteoblastic-like cells were characterized through cell viability/proliferation and enzymatic activity. Tribocorrosion tests were performed under a reciprocating sliding configuration and low contact pressure. Electrochemical techniques were used to measure the corrosion kinetics of the system, under free potential conditions. All tests were performed at a controlled atmosphere. The morphology and topography of the wear scar were evaluated. The results showed that the presence of an osteoblastic cell layer on the implant surface significantly influences the tribocorrosion behavior of Ti6Al4V alloy. It was concluded that the cellular material was able to form an extra protective layer that inhibits further wear degradation of the alloy and decreases its corrosion tendency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A robotic control design considering all the inherent nonlinearities of the robot-engine configuration is developed. The interactions between the robot and joint motor drive mechanism are considered. The proposed control combines two strategies, one feedforward control in order to maintain the system in the desired coordinate, and feedback control system to take the system into a desired coordinate. The feedback control is obtained using State-Dependent Riccati Equation (SDRE). For link positioning two cases are considered. Case I: For control positioning, it is only used motor voltage; Case II: For control positioning, it is used both motor voltage and torque between the links. Simulation results, including parametric uncertainties in control shows the feasibility of the proposed control for the considered system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate skeletal and dental stability in patients who had temporomandibular joint (TMJ) reconstruction and mandibular counterclockwise advancement using TMJ Concepts total join, prostheses (TMJ Concepts Inc. Ventura, CA) with maxillary osteotomies being performed at the same operation. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one surgeon (Wolford). Forty-seven females were studied; the average post-surgical follow-up was 40.6 months. Lateral cephalograms were analyzed to estimate surgical and post-surgical changes. During surgery, the occlusal plane angle decreased 14.9 +/- 8.0 degrees. The maxilla moved forward and upward. The posterior nasal spine moved downward and forward. The mandible advanced 7.9 +/- 3.5 mm at the lower incisor tips, 12.4 +/- 5.4 mm at Point B, 17.3 +/- 7.0 mm at menton, 18.4 +/- 8.5 mm at pogonion, and 11.0 +/- 5.3 mm at gonion. Vertically, the lower incisors moved upward -2.9 +/- 4.0 mm. At the longest follow-up post surgery, the maxilla showed minor horizontal changes while all mandibular measurements remained stable. TMJ reconstruction and mandibular advancement with TMJ Concepts total joint prosthesis in conjunction with maxillary osteotomies for counter-clockwise rotation of the rnaxillo-mandibular complex was a stable procedure for these patients at the longest follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to verify possible relationships between global body posture and temporomandibular joint internal derangement (TMJ-id), by comparing 30 subjects presenting typical TMJ-id signs to 20 healthy subjects. Body posture was assessed using the analysis of muscle chains on several photographs. Results show a higher frequency of lifted shoulders (p=0.04) and of changes in the antero-internal hip chain (p=0.02) in the test group, but no further differences were found significant between the control and test groups. The test group was then divided into three subgroups according to the Helkimo index of temporomandibular disorder severity. Again, no significant differences were found between the subgroups. However, there was a trend noticed in the group with the most severe dysfunction, to present a forward head and shoulders posture. Results are discussed in light of previous studies using the same sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporomandibular joint arthrocentesis is a method of flushing out the synovial fluid that is currently performed by providing a double puncture to the upper joint space. The traditional 2-needle technique has some restrictions, such as the difficulty in performing it in the presence of intra-articular adherences and in the female patients, because the space is very small. The adoption of a single-needle for fluid injection might have some advantages with respect to the traditional 2-needle approach in terms of easily, time of execution and tolerability. We describe a single needle technique and we recommend the use.