973 resultados para Implant-retained prostheses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This randomised, controlled multicentre trial aimed at comparing two versions of a variable-thread dental implant design to a standard tapered dental implant design in cases of immediate functional loading for 36 months after loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To estimate the applicability of potential sites for insertion of orthodontic mini-implants (OMIs) by a systematic review of studies that used computed tomography (CT) or cone beam CT to evaluate anatomical bone quality and quantity parameters, such as bone thickness, available space, and bone density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostics imaging is an essential component of patient selection and treatment planning in oral rehabilitation by means of osseointegrated implants. In 2002, the EAO produced and published guidelines on the use of diagnostic imaging in implant dentistry. Since that time, there have been significant developments in both the application of cone beam computed tomography as well as in the range of surgical and prosthetic applications that can potentially benefit from its use. However, medical exposure to ionizing radiation must always be justified and result in a net benefit to the patient. The as low a dose as is reasonably achievable principle must also be applied taking into account any alternative techniques that might achieve the same objectives. This paper reports on current EAO recommendations arising from a consensus meeting held at the Medical University of Warsaw (2011) to update these guidelines. Radiological considerations are detailed, including justification and optimization, with a special emphasis on the obligations that arise for those who prescribe or undertake such investigations. The paper pays special attention to clinical indications and radiographic diagnostic considerations as well as to future developments and trends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The aim of this study was to compare the clinical outcomes after 2 years with bone level implants placed to restore a single missing teeth that needed simultaneous augmentation and were treated with a transmucosal or submerged approach. METHODS: This study analyzed a subset of patients included in an ongoing prospective multicenter randomized clinical trial (RCT) involving12 centers where patients were to be followed-up to 5 years after loading. Of the 120 implants that were placed in the original study, and randomly assigned to submerged or non-submerged healing, 52 needed simultaneous augmentation (28 women patients and 24 men patients, between 23 and 78 years of age). Twenty-seven of them received implants with submerged healing (AuS), while in 25 patients the implants were inserted with a non-submerged protocol (AuNS). At the 2-year follow-up visit, radiographic crestal bone level changes were recorded as well as soft tissue parameters included Pocket probing depth (PPD), bleeding on probing (BoP) and clinical attachment level (CAL) at teeth adjacent to the implant site. RESULTS: After 2 years a small amount of bone resorption was found in both groups (0.37 ± 0.49 mm in the AuS group and 0.54 ± 0.76 in the AuNS group; P < 0.001). There was no statistically significant difference between AuS Group and AuNS group for PPD (2.5 vs. 2.4 mm), BOP (BOP + sites: 8.8% vs. 11.5%) and CAL (2.8 vs. 2.4 mm) at the 2-year follow-up visit. CONCLUSIONS: When a single implant is placed in the aesthetic zone in conjunction with bone augmentation for a moderate peri-implant defect, submerged and transmucosal healing determine similar outcome, hence there is no need to submerge an implant in this given clinical situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To test the survival rates, and the technical and biological complication rates of customized zirconia and titanium abutments 5 years after crown insertion. MATERIAL AND METHODS: Twenty-two patients with 40 single implants in maxillary and mandibular canine and posterior regions were included. The implant sites were randomly assigned to zirconia abutments supporting all-ceramic crowns or titanium abutments supporting metal-ceramic crowns. Clinical examinations were performed at baseline, and at 6, 12, 36 and 60 months of follow-up. The abutments and reconstructions were examined for technical and/or biological complications. Probing pocket depth (PPD), plaque control record (PCR) and Bleeding on Probing (BOP) were assessed at abutments (test) and analogous contralateral teeth (control). Radiographs of the implants revealed the bone level (BL) on mesial (mBL) and distal sides (dBL). Data were statistically analyzed with nonparametric mixed models provided by Brunner and Langer and STATA (P < 0.05). RESULTS: Eighteen patients with 18 zirconia and 10 titanium abutments were available at a mean follow-up of 5.6 years (range 4.5-6.3 years). No abutment fracture or loss of a reconstruction occurred. Hence, the survival rate was 100% for both. Survival of implants supporting zirconia abutments was 88.9% and 90% for implants supporting titanium abutments. Chipping of the veneering ceramic occurred at three metal-ceramic crowns supported by titanium abutments. No significant differences were found at the zirconia and titanium abutments for PPD (meanPPD(ZrO2) 3.3 ± 0.6 mm, mPPD(T) (i) 3.6 ± 1.1 mm), PCR (mPCR(Z) (rO) (2) 0.1 ± 0.3, mPCR(T) (i) 0.3 ± 0.2) and BOP (mBOP(Z) (rO) (2) 0.5 ± 0.3, mBOP(T) (i) 0.6 ± 0.3). Moreover, the BL was similar at implants supporting zirconia and titanium abutments (mBL(Z) (rO) (2) 1.8 ± 0.5, dBL(Z) (rO) (2) 2.0 ± 0.8; mBL(T) (i) 2.0 ± 0.8, dBL(T) (i) 1.9 ± 0.8). CONCLUSIONS: There were no statistically or clinically relevant differences between the 5-year survival rates, and the technical and biological complication rates of zirconia and titanium abutments in posterior regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This RCT compared non-surgical treatment of peri-implant mucositis with or without systemic antibiotics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To perform a literature review on peri-implant metastases and primary malignoma and report a case of a pulmonary metastasis around dental implants of the anterior mandibular jaw that mimicked peri-implantitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this systematic review was to assess the optimal number of implants for removable reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Swiss Federal Office of Public Health demanded a nationwide HTA-registry for cervical total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISSspine registry is to generate evidence about the safety and efficiency of cervical TDA. MATERIALS AND METHODS: Three hundred thirty-two cases treated between 3.2005 and 6.2006 who were eligible for 5 years follow-ups were included in the study. Follow-up rates for 3-6 months, 1, 2 and 5 years were 84.6, 74.4, 50.6 and 64.8 %, respectively. Outcome measures were neck and arm pain, medication, quality of life, intraoperative and postoperative complication and revision rates. In addition, segmental mobility, ossification, adjacent and distant segment degeneration were analyzed at the 5-year follow-up. RESULTS: There was significant, clinically relevant and lasting reduction of neck (preop/postop 60/21 VAS points) and arm pain (preop/postop VAS 67/17) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.39/0.82 EQ-5D points) until the 5-year follow-up. The rates for intraoperative and early postoperative complications were 0.6 and 7.2 %, respectively. In 0.6 % an early and in 3.9 % a late revision surgery was performed. At the 5-year follow-up, the average range of motion of the mobile segments (88.2 %) was 10.2°. In 40.7 % of the patients osteophytes at least potentially affecting range of motion were seen. CONCLUSIONS: Cervical TDA appeared as safe and efficient in long-term pain alleviation, consequent reduction of pain killer consumption and in improvement of quality of life. The improvement is stable over the 5 years postoperative period. The vast majority of treated segments remained mobile after 5 years, although 40.7 % of patients showed osteophytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This article describes reconstruction of the severely atrophic mandible using calvarial bone grafts for implant-supported prosthetic oral rehabilitation. The study aim was to evaluate the efficacy of the treatment by determining implant survival and complication rates, and the extent of the postoperative graft resorption. STUDY DESIGN: Ten patients who underwent the treatment were followed clinically and radiologically using panoramic radiographs and CT scans during a mean postoperative period of 30 months. RESULTS: Good bone healing was observable 6 months postoperatively. The height reduction measured on panoramic radiographs was insignificant (mean 0.68 mm). Only minor complications occurred. Implant survival was 95%. Prosthodontic treatment was successfully performed in all cases, resulting in an improvement of oral function. Histological analysis of 1 bone biopsy showed minimal resorptive changes in otherwise very dense bone. CONCLUSION: Augmentation using calvarial grafts is a promising treatment alternative for the severely atrophic mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microrough titanium (Ti) surfaces of dental implants have demonstrated more rapid and greater bone apposition when compared with machined Ti surfaces. However, further enhancement of osteoblastic activity and bone apposition by bio-functionalizing the implant surface with a monomolecular adsorbed layer of a co-polymer - i.e., poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) and its derivatives (PLL-g-PEG/PEG-peptide) - has never been investigated. The aim of the present study was to examine early bone apposition to a modified sandblasted and acid-etched (SLA) surface coated with an Arg-Gly-Asp (RGD)-peptide-modified polymer (PLL-g-PEG/PEG-RGD) in the maxillae of miniature pigs, and to compare it with the standard SLA surface. Test and control implants had the same microrough topography (SLA), but differed in their surface chemistry (polymer coatings). The following surfaces were examined histomorphometrically: (i) control - SLA without coating; (ii) (PLL-g-PEG); (iii) (PLL-g-PEG/PEG-RDG) (RDG, Arg-Asp-Gly); and (iv) (PLL-g-PEG/PEG-RGD). At 2 weeks, RGD-coated implants demonstrated significantly higher percentages of bone-to-implant contact as compared with controls (61.68% vs. 43.62%; P < 0.001). It can be concluded that the (PLL-g-PEG/PEG-RGD) coatings may promote enhanced bone apposition during the early stages of bone regeneration.