952 resultados para Image Classification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work we present here addresses cue-based noun classification in English and Spanish. Its main objective is to automatically acquire lexical semantic information by classifying nouns into previously known noun lexical classes. This is achieved by using particular aspects of linguistic contexts as cues that identify a specific lexical class. Here we concentrate on the task of identifying such cues and the theoretical background that allows for an assessment of the complexity of the task. The results show that, despite of the a-priori complexity of the task, cue-based classification is a useful tool in the automatic acquisition of lexical semantic classes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Machine learning and pattern recognition methods have been used to diagnose Alzheimer's disease (AD) and mild cognitive impairment (MCI) from individual MRI scans. Another application of such methods is to predict clinical scores from individual scans. Using relevance vector regression (RVR), we predicted individuals' performances on established tests from their MRI T1 weighted image in two independent data sets. From Mayo Clinic, 73 probable AD patients and 91 cognitively normal (CN) controls completed the Mini-Mental State Examination (MMSE), Dementia Rating Scale (DRS), and Auditory Verbal Learning Test (AVLT) within 3months of their scan. Baseline MRI's from the Alzheimer's disease Neuroimaging Initiative (ADNI) comprised the other data set; 113 AD, 351 MCI, and 122 CN subjects completed the MMSE and Alzheimer's Disease Assessment Scale-Cognitive subtest (ADAS-cog) and 39 AD, 92 MCI, and 32 CN ADNI subjects completed MMSE, ADAS-cog, and AVLT. Predicted and actual clinical scores were highly correlated for the MMSE, DRS, and ADAS-cog tests (P<0.0001). Training with one data set and testing with another demonstrated stability between data sets. DRS, MMSE, and ADAS-Cog correlated better than AVLT with whole brain grey matter changes associated with AD. This result underscores their utility for screening and tracking disease. RVR offers a novel way to measure interactions between structural changes and neuropsychological tests beyond that of univariate methods. In clinical practice, we envision using RVR to aid in diagnosis and predict clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le nombre d'examens fluoroscopiques pratiqués en fluoroscopie est en augmentation constante en cardiologie pédiatrique. Ces examens ont un bénéfice évident pour le diagnostic et la thérapie de pathologies cardiaques complexes mais ils sont également la cause d'exposition à des hautes doses de radiation. Notre étude propose donc d'analyser cette pratique au Centre Hospitalier Universitaire Vaudois (CHUV) ainsi que d'établir des niveaux de référence diagnostiques et de rechercher les moyens possibles de diminution de doses. La base de données que nous avons analysé provient du service de cardiologie pédiatrique du CHUV (Lausanne). Elle contient 873 examens fluoroscopiques pratiqués entre le 1er janvier 2003 et le 31 décembre 2011 et se compose des données démographiques, du temps de scopie en minutes et du dose area product (DAP) en Gycm 2 pour chaque examen. Les examens sont séparés en deux modalités, diagnostique et interventionnel et ont été pratiqués sur l'installation GE jusqu'en juillet 2010 et par la suite sur l'installation Philips. L'analyse s'est faite sur Excel et sur JMP Statistics afin d'établir la distribution démographique de l'échantillon, les moyennes et percentiles 75. Les examens diagnostiques ont été étudié par classes d'âge et les examens interventionnels selon une classification d'intervention (Ranking) établie en collaboration avec le médecin responsable de ces procédures au CHUV. Seuls les groupes d'examens ayant un nombre égal ou supérieur à 20 ont été analysés. Nous avons donc analysé 873 examens, dont 512 diagnostiques et 361 interventionnels. Le temps de scopie moyen pour l'ensemble des examens diagnostiques est de 11.91 minutes et le DAP moyen de 12.04 Gycm2. Concernant les examens interventionnels, les moyennes de temps de scopie et de DAP sont de 17.74 minutes et 9.77 Gycm2 respectivement. En plus des analyses par classes d'âges et par ranking, nous avons étudié les examens selon leurs données démographiques ainsi que par pathologie et par installation. L'ensemble des examens diagnostiques connaissent une diminution significative (p<0.0001) de 30% pour le temps de scopie moyen et de 60% pour le DAP moyen en passant de l'installation la plus ancienne, GE, à la plus récente, Philips. Concernant les examens interventionnels, La différence entre les deux installations est encore plus marquée avec un temps de scopie moyen 55 % inférieur ( Gycm2) et un DAP moyen 73 % (p=0.0002) plus faible sur Philips par rapport à GE. Ces différences sont principalement expliquées par l'apport de nouveaux outils sur l'installation Philips, tels que la digitalisation et le traitement de l'image, de la possibilité de changer le nombre d'images par seconde durant un examen ainsi que de l'amélioration de la pratique des examinateurs. Nous avons pu définir des percentiles 75 pour les examens diagnostiques par classes d'âge et par pathologie et pour les examens interventionnels selon le ranking établi par le Dr Di Bernardo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies at high magnetic fields using the phase of gradient-echo MR images have shown the ability to unveil cortical substructure in the human brain. To investigate the contrast mechanisms in phase imaging, this study extends, for the first time, phase imaging to the rodent brain. Using a 14.1 T horizontal bore animal MRI scanner for in vivo micro-imaging, images with an in-plane resolution of 33 microm were acquired. Phase images revealed, often more clearly than the corresponding magnitude images, hippocampal fields, cortical layers (e.g. layer 4), cerebellar layers (molecular and granule cell layers) and small white matter structures present in the striatum and septal nucleus. The contrast of the phase images depended in part on the orientation of anatomical structures relative to the magnetic field, consistent with bulk susceptibility variations between tissues. This was found not only for vessels, but also for white matter structures, such as the anterior commissure, and cortical layers in the cerebellum. Such susceptibility changes could result from variable blood volume. However, when the deoxyhemoglobin content was reduced by increasing cerebral blood flow (CBF) with a carbogen breathing challenge, contrast between white and gray matter and cortical layers was not affected, suggesting that tissue cerebral blood volume (and therefore deoxyhemoglobin) is not a major source of the tissue phase contrast. We conclude that phase variations in gradient-echo images are likely due to susceptibility shifts of non-vascular origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first AO comprehensive pediatric long-bone fracture classification system has been proposed following a structured path of development and validation with experienced pediatric surgeons. A Web-based multicenter agreement study involving 70 surgeons in 15 clinics and 5 countries was conducted to assess the reliability and accuracy of this classification when used by a wide range of surgeons with various levels of experience. Training was provided at each clinic before the session. Using the Internet, participants could log in at any time and classify 275 supracondylar, radius, and tibia fractures at their own pace. The fracture diagnosis was made following the hierarchy of the classification system using both clinical terminology and codes. kappa coefficients for the single-surgeon diagnosis of epiphyseal, metaphyseal, or diaphyseal fracture type were 0.66, 0.80, and 0.91, respectively. Median accuracy estimates for each bone and type were all greater than 80%. Depending on their experience and specialization, surgeons greatly varied in their ability to classify fractures. Pediatric training and at least 2 years of experience were associated with significant improvement in reliability and accuracy. Kappa coefficients for diagnosis of specific child patterns were 0.51, 0.63, and 0.48 for epiphyseal, metaphyseal, and diaphyseal fractures, respectively. Identified reasons for coding discrepancies were related to different understandings of terminology and definitions, as well as poor quality radiographic images. Results supported some minor adjustments in the coding of fracture type and child patterns. This classification system received wide acceptance and support among the surgeons involved. As long as appropriate training could be performed, the system classification was reliable, especially among surgeons with a minimum of 2 years of clinical experience. We encourage broad-based consultation between surgeons' international societies and the use of this classification system in the context of clinical practice as well as prospectively for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic efficiency of plain film and spiral CT examinations with 3D reconstructions of 42 tibial plateau fractures and to assess the accuracy of these two techniques in the pre-operative surgical plan in 22 cases. Forty-two tibial plateau fractures were examined with plain film (anteroposterior, lateral, two obliques) and spiral CT with surface-shaded-display 3D reconstructions. The Swiss AO-ASIF classification system of bone fracture from Muller was used. In 22 cases the surgical plans and the sequence of reconstruction of the fragments were prospectively determined with both techniques, successively, and then correlated with the surgical reports and post-operative plain film. The fractures were underestimated with plain film in 18 of 42 cases (43%). Due to the spiral CT 3D reconstructions, and precise pre-operative information, the surgical plans based on plain film were modified and adjusted in 13 cases among 22 (59%). Spiral CT 3D reconstructions give a better and more accurate demonstration of the tibial plateau fracture and allows a more precise pre-operative surgical plan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This was a descriptive, retrospective study, with a quantitative method, with the aim of analyzing the nursing diagnoses contained in the records of children of 0 to 36 months of age who attended infant health nursing consults. A documentary analysis and the cross-mapping technique were used. One hundred eighty-eight different nursing diagnoses were encountered, of which 33 (58.9%) corresponded to diagnoses contained in the Nomenclature of Nursing Diagnoses and Interventions and 23 (41.1%) were derived from ICNP® Version 1.0. Of the 56 nursing diagnoses, 43 (76.8%) were considered to be deviations from normalcy. It was concluded that the infant health nursing consults enabled the identification of situations of normalcy and abnormality, with an emphasis on the diagnoses of deviations from normalcy. Standardized language favors nursing documentation, contributing to the care of the patient and facilitating communication between nurses and other health professionals.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the agreement and disagreement between the assessments by applying or not a patient classification instrument, and to investigate the association between the agreement and personal and professional characteristics of the evaluators. Method: This is a descriptive exploratory study. 105 patients were hospitalized in a teaching hospital in the state of Sao Paulo, using the kappa statistic (weighted) and the Bootstrap method. Results: The agreement between the assessments were​​: kw 0.87 (instrument x internal evaluator), kw 0.78 (instrument x external evaluator) and kw 0.76 (between evaluators) and the influence of some personal and professional characteristics. The assessments conducted through the use of an instrument contemplated a greater number of areas of care in relation to when the instrument was not applied. Conclusion: The use of this instrument is recommended in order to more effectively identify care needs of patients.




Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Identifying the prescribed nursing care for hospitalized patients at risk of falls and comparing them with the interventions of the Nursing Interventions Classifications (NIC). Method: A cross-sectional study carried out in a university hospital in southern Brazil. It was a retrospective data collection in the nursing records system. The sample consisted of 174 adult patients admitted to medical and surgical units with the Nursing Diagnosis of Risk for falls. The prescribed care were compared with the NIC interventions by the cross-mapping method. Results: The most prevalent care were the following: keeping the bed rails, guiding patients/family regarding the risks and prevention of falls, keeping the bell within reach of patients, and maintaining patients’ belongings nearby, mapped in the interventions Environmental Management: safety and Fall Prevention. Conclusion: The treatment prescribed in clinical practice was corroborated by the NIC reference.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To learn about the experiences of adolescents diagnosed with idiopathic scoliosis. Method: Integrative review of the literature published within a specified time frame. Results: For both sexes, the predominant clinical symptom of this condition appears to be the negative effect that the deformity exerts on perceived self-image. Quantitative studies used numerical scores to assess perceptions of body image but did not analyse emotional aspects. Patients treated surgically were found to have a better self-image than patients treated with a brace. Quality of life was improved by a reduction in the magnitude of the curve. Conclusion: Spinal deformity exerts a psychological effect on adolescent girls.