992 resultados para IMAGING FINDINGS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report the magnetic resonance imaging diagnostic features in two cases with respectively lumbar epidural hematoma and cavernous hemangioma of the lumbar epidural space. Enhanced MRI T1-weighted scans show a hyperintense signal rim surrounding the vascular lesion. Non-enhanced T2-weighted scans showed hyperintense signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Noonan syndrome is a multiple congenital anomaly syndrome, and bleeding diathesis is considered part of the clinical findings. The purpose of this study was to determine the frequency of hemostatic abnormalities in a group of Noonan syndrome patients. METHOD: We studied 30 patients with clinical diagnosis of Noonan syndrome regarding their hemostatic status consisting of bleeding time, prothrombin time, activated partial thromboplastin time and thrombin time tests, a platelet count, and a quantitative determination of factor XI. RESULTS: An abnormal laboratory result was observed in 9 patients (30%). Although coagulation-factor deficiencies, especially factor XI deficiency, were the most common hematological findings, we also observed abnormalities of platelet count and function in our screening. CONCLUSIONS: Hemostatic abnormalities are found with some frequency in Noonan syndrome patients (30% in our sample). Therefore, we emphasize the importance of a more extensive hematological investigation in these patients, especially prior to an invasive procedure, which is required with some frequency in this disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Williams-Beuren syndrome is a rare multiple anomalies/mental retardation syndrome caused by deletion of contiguous genes at chromosome region 7q11.23. The aim of this work was to determine the frequency and the types of renal and urinary tract anomalies in 20 patients with Williams-Beuren syndrome. METHODS: The fluorescence in situ hybridization test using a LSI Williams syndrome region DNA probe was performed for all 20 patients to confirm the diagnosis of Williams-Beuren syndrome. A prospective study was performed in order to investigate renal and urinary aspects using laboratory assays to check renal function, ultrasonography of the kidneys and urinary tract, voiding cystourethrogram and urodynamics. RESULTS: Deletion of the elastin gene (positive fluorescence in situ hybridization test) was found in 17 out of 20 patients. Renal alterations were diagnosed in 5 of 17 (29%) the patients with the deletion and in 1 of 3 patients without the deletion. Fourteen patients with the deletion presented dysfunctional voiding. Arterial hypertension was diagnosed in 3 patients with deletions and 1 of these presented bilateral stenosis of the renal arteries. CONCLUSIONS: Due to the high incidence of renal and urinary abnormalities in Williams-Beuren syndrome, performing a systematic laboratory and sonographic evaluation of the patients is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Os mais recentes métodos de neuro imagem tal como a Ressonância Magnética (RM) permitiram obter imagens detalhadas do cérebro humano in vivo. Essas imagens revelam, muitas vezes, achados imprevistos face ao padrão normal, com elevada propensão para os indivíduos idosos e franca coexistência com fatores de risco vascular, como característica dum processo de envelhecimento normal. Embora na última década tenham surgido várias publicações sobre este assunto, ele continua ainda pouco explicado. Um pouco por todo o mundo têm emergido os programas de prevenção da doença e promoção da saúde desenvolvidos pela Saúde Pública suportadas sobretudo pelo avanço das tecnologias médicas que resultaram, entre outros impactos, num crescimento da população idosa. Estima-se, em 2030, uma composição demográfica com 20% de indivíduos acima dos 65 anos. Neste contexto, a doença microvascular cerebral é a causa mais frequente de comprometimento cognitivo vascular no idoso sendo as características senescentes na imagem por RM do tipo lesões isquémicas da Substância Branca (Leukoaraiosis) e enfartes lacunares (Status lacunar), atrofia cerebral, gliose e acumulação excessiva de ferro nos núcleos da base. Esta tese, considerando a linha de investigação de que deriva – Ciências da Vida - especialização em Medicina Clinica - Biotecnologia, reúne e reflete sobre três vertentes ligadas à RM e interdependentes em relação a uma problemática comum. A primeira trata da caracterização da Tecnologia por Ressonância Magnética existente em Portugal, a qual inclui uma avaliação exploratória da aplicação da técnica de Difusão Anisotrópica nos estudos cerebrais. As dimensões analíticas estudadas foram a Tecnológica, Sociodemográfica e Económica. Na recolha de dados recorreu-se a várias fontes de informação e a uma metodologia exploratória faseada, validada pela triangulação dos resultados. A sua análise obedeceu a critérios de estratificação e agrupamento segundo as mesmas dimensões analíticas. Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular A segunda descreve o estudo anátomo – radiológico que recaiu sobre parâmetros de quantificação assente na temática do cérebro do idoso em cadáver segundo uma metodologia experimental aplicada às métricas da difusão por RM. Na terceira, e última, é apresentado o estudo técnico - radiológico para avaliação e otimização da imagem ponderada em difusão em estudos clínicos associados ao cérebro do idoso “The Usual Brain Aging” ou Envelhecimento Cerebral Normal, com base metodológica assente nos critérios e indicadores estabelecidos pelo Estudo de Imagem de Roterdão (Rotterdam Scan Study - RSS). Como principais resultados obteve-se que não existem em Portugal estruturas para avaliação dos equipamentos pesados ou Agência de Avaliação das Tecnologias da Saúde para desenvolver o importante papel da produção de estudos comparativos entre os equipamentos disponíveis no mercado, a relação preço-qualidade e a sua afetação às necessidades clínico-epidemiológicas. Constatou-se que a implementação de equipamentos de RM está fortemente assente em critérios económicos carecendo de recomendações e diretivas para o uso racionalizado destas tecnologias. Quanto a dados quantitativos concluímos que a maioria dos equipamentos está instalada em instituições privadas (80,2%); a intensidade de campo magnético mais frequente é [1,5T] com 119 equipamentos; os equipamentos estão instalados maioritariamente nos distritos de Lisboa (55 unidades) e do Porto (39 unidades); o rácio médio de equipamentos por habitante em Portugal é de 1 para 65 195 habitantes; a amplitude de gradientes com maior expressão na amostra é 30-39mT/m; a maioria dos equipamentos foi instalada no intervalo temporal [2009-2012] com 59 equipamentos; apenas 6 instituições desenvolvem investigação clinica e a maioria das bobinas para estudos de crânio são do tipo Array. O estudo de otimização da técnica da difusão revelou, quanto à avaliação dos valoresb, que os mais baixos (b=500 s/mm2 e b=1000 s/mm2), apresentam maior IS e SNR sendo esta uma boa medida referente à qualidade de imagem, no entanto, os valores-b mais elevados (b=2000 s/mm2) apresentam maior CNR e CR, face aos anteriores, o Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular que apesar de proporcionar inferior detalhe anatómico e consequentemente inferior qualidade de imagem, num encéfalo normal, pode auxiliar na interpretação e apresentar vantagens na identificação de lesões microvasculares sempre que persistirem dúvidas em relação ao diagnóstico diferencial de doença microvascular do tipo status lacunar ou Hiperintensidades da Substância Branca. As alterações deste parâmetro são particularmente refletidas nas diferenças da avaliação da qualidade de imagem na região fronto-calos Concluímos da avaliação quantitativa da concentração média de ferro (26Fe) em todas as faixas etárias que os núcleos da base que apresentam maior concentração são, por ordem decrescente: Substância Nigra, Globus Pallidus, Putamen, Tálamo, Núcleo Rubro e Núcleo Caudado; que existe uma predominância na concentração de ferro (26Fe) no hemisfério esquerdo e que os indivíduos do género masculino apresentam mais ferro (26Fe) que os do género feminino nas faixas etárias [30-40[, [40-50[ e [50-60[. Como principal conclusão do estudo da concentração média de ferro em relação à idade destacamos que a concentração média de ferro (26Fe) é superior nos grupos etários superiores, logo aumenta com a idade, sobretudo na Substância Nigra e no Núcleo Lenticular. No estudo técnico-radiológico encontrámos evidências do aumento da difusibilidade da água na substância branca subcortical dos sujeitos idosos comparativamente aos mais jovens. Uma relação idêntica foi avaliada nos tálamos. O aumento relacionado com a idade parece ser predominantemente observado em doentes com mais de 65 anos de idade o que pode refletir alterações estruturais ligeiras associados ao envelhecimento normal. Os resultados indicam que a análise quantitativa das imagens ponderadas em difusão fornece informações, sobre a estrutura do cérebro, as quai s não estão disponíveis apenas por inspeção visual, tanto nas imagens ponderadas em difusão como em outras sequências de aplicação clínica de rotina. Para fazer face às desvantagens dos sistemas de quantificação das HSB os quais são dispendiosos, complexos, requererem tecnologia e formação específicas, recomendamos que a aplicação automatizada GUIAL, desenvolvida ao longo do nosso trabalho é de utilização elementar e prática para que seja introduzida nos sistemas de aquisição de imagem por RM com o fim de integrar o processamento de imagem nos indivíduos portadores de fatores de risco vascular. A avaliação do ADC, nesta amostra, permitiu concluir que a variação desta variável é explicada estatisticamente pela existência da condição clínica de status lacunar em ambos os hemisférios ou por outras palavras, o status lacunar influencia o valor de ADC. Embora uma pequena percentagem da variação do ADC seja explicada pelo género, o ADC nos homens foi superior ao das mulheres o que não nos surpreende, pois são também os homens onde a frequência de doença microvascular se revelou mais expressiva. Os valores do ADC, globalmente, entre os hemisférios cerebrais não mostraram alterações exceto na SB entre os idosos e não idosos. A SB da região frontal mostrou valores diminuídos na anisotropia e isotropia face às restantes áreas anatómicas. Os estudos indicam que na idade avançada existe uma maior predisposição para suscetibilidades de estrutura com status de desconexão. A classificação das HSB foi superior em indivíduos mais velhos e com status lacunar, e em menor quantidade (inferior rating de classificação) nos indivíduos idosos sem status lacunar. As alterações volumétricas foram mais frequentes no homem do que na mulher, presumivelmente devido à associação com a elevada classificação de status lacunar. Um aumento do índice de Evan correspondeu, neste estudo, ao aumento das HSB, à diminuição do volume cerebral total, à expansão ventrículo-sulcal frontal e ao aumento da medida do ângulo caloso. Estes resultados foram agravados pela classificação elevada de status lacunar nos indivíduos que apresentaram indícios de doença de pequenos vasos, com manifesto aumento dos espaços de Virchow-Robin,enfartes lacunares ou HSB. Esses resultados foram mais expressivos no género masculino do que no feminino revelando uma maior vulnerabilidade sobretudo na atrofia frontal nos homens. Por sua vez as dimensões do Corpo Caloso tornaram-se reduzidas devido à compressão dos ventrículos laterais e terceiro ventrículo. Estes indicadores tiveram expressão particularmente nos indivíduos com mais de 65 anos. ---------------------------------------------------------------------------------------------ABSTRACT: The latest neuroimaging methods, such as Magnetic Resonance Imaging (MRI), have enabled detailed images of in vivo human brain. These images reveal often unexpected findings related to the normal pattern, with high predisposition for the elderly people with forthright coexistence with vascular risk factors such as characteristics of a normal aging process. Although it has been, in the last decade, several publications on this subject, it is still little explained. All over the world have emerged disease prevention programs and health promotion developed by the Public Health sector, supported mainly by the advancement of medical technologies that have resulted, among other impacts, in a growing of the elderly population. It is estimated, in 2030, a demographic composition with 20% o people over 65 years. In this context, microvascular disease is the most common cause of cognitive vascular impairment in the elderly and senescent characteristics in the MRI trough ischemic lesions of the white matter (Leukoaraiosis) and lacunar infarcts (lacunar status), cerebral atrophy, gliosis and iron accumulation in the basal ganglia in excess.This thesis, considering the research line that stems - Life Sciences - specialization in Clinical Medicine, Biotechnology, gathers and reflects on three aspects linked to MR, interdependent and related to a common problem. The first deals with the Magnetic Resonance Technology characterization in Portugal, which includes an exploratory evaluation of the implementation of Anisotropic Diffusion technique in brain studies. The analytical dimensions studied were the Technologic, Socio-demographic and Economics. Collecting data was supported by different sources of information and was applied an exploratory methodology whose results were validated by triangulation. The research method was grouped and stratified criteria under the same analytical dimensions. The second describes the anatomical study - which was focused on radiological measurement parameters, based on the brain’s specimen under an experimental methodology applied to MRI diffusion metrics. Radiological evaluation and optimization of the weighted image diffusion in clinical studies were associated with the brain of the elderly "The Usual Brain Aging" with methodological basis based on established criteria and indicators by Rotterdam Scan Study (RSS). The main results obtained reveal the inexistence frameworks in Portugal for evaluation of equipments or Agency of Health Technology to produce studies comparing the equipment available on the market, the value for money and its allocation to clinical and epidemiological needs. It was found that the implementation of MRI equipment is strongly based on economic criteria lacking recommendations and guidelines for the rationalized use of these technologies. As the quantitative data we conclude that most of the scanners are located in private clinical institutions (80,2%); the most frequent magnetic field intensity is [1.5T] with 119 scanners; the scanners are mainly installed in Lisbon (55 units) and Porto (39 units) districts; the average ratio of equipment per capita in Portugal is 1 to 65 195 people; the gradient power with higher expression in the sample is 30-39mT / m;most of the scanners were installed in the years range [2009-2012 years] with 59 equipment; only 6 clinical placements develop clinical research and the most coils for brain studies are of Array type. The optimization study of diffusion technique revealed, as the assessment of the bvalues, the lower (b = 500 s / mm2 and b = 1000 s / mm 2), promotes an increase in the SI and SNR being this measure related to a higher image quality, however the highest b values (b = 2000 s / mm 2) have a higher CNR (Contrast to Noise-Ratio) and CR (Contrast Ratio), compared to the previous ones. This may provide less anatomical details and, thus, ower image quality, of a normal brain, however can help the interpretation and have advantages in identifying microvascular injuries when doubts persist regarding the differential diagnosis of microvascular disease of lacunar or WMH (White Matter Hyperintensities) status type. Changes on this parameter are Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular particularly reflected in the differences of image quality evaluation in the frontocallosum anatomical area. We conclude from the quantitative assessment of the average concentration of iron (26Fe), in all age groups to the basal ganglia, that the higher concentrations are, in descending order: Nigral Substantia, Globus pallidus, Putamen, Thalamus, Rubio nucleus and Caudate nucleus; that there is a predominance in the concentration of iron (26Fe) in the left hemisphere and that male gender show higher iron (26Fe) level tha females, in the age groups [30-40 [[40-50 [and [50- 60 [. Regarding a main conclusion of the mean concentration study of iron, in terms of age we point out that the average concentration of iron (26Fe) is higher among older groups and increases with age, especially in Nigral Substantia and Lenticular Nucleus. On the technical and radiological study we found evidence of an increased in water /diffusivity in the ubcortical white matter of the elderly compared with younger subjects. A similar relationship was assessed in the Thalamus. The increase agerelated seems to be predominantly observed in patients over 65 years which may reflect minor structural changes associated with normal aging. The results indicate that quantitative analysis of diffusion weighted imaging can provide information about the structure of the brain which is not reached only by visual inspection or standard sequences applied in clinical routine. To address the disadvantages the systems of quantification of WMH which the authors state that are costly, complex, require specific technology and training, we recommend that the automated application GUIAL, developed over our work is basic and practical to use and to be introduced in MR image systems acquisition in order to integrate image processing in patients with vascular risk factors. The evaluation of the ADC showed that its variation is statistically explained by the existence of the medical condition of lacunar status, in both hemispheres, or in other words, the lacunar status influences the ADC value. Although a small percentage of the ADC variation is explained by gender, the ADC in men was higher than women which Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular do not surprise us, since they are also men where the frequency of microvasculardisease has proved more significant. The values of ADC, overall, between the cerebral hemispheres showed no changes but were different in WM among the elderly and non-elderly subjects.The WM's forehead showed decreased values in anisotropy and isotropy face the other anatomical areas. The studies indicate that in old age there is a greater tendency to higher susceptibility to disconnection- status framework. The classification of WMH was higher in elderly people and lacunar status, and fewer (lower classification rating) in the elderly without lacunar status. volumetric changes were more frequent in men than in women, most probably because of its association with high lacunar status rating. An increase of Evan index corresponded, in this study, to an increase in WMH, to a decreased of total brain volume, to a ventricle sulcal frontal and callous angle expansion. These results were wound up by high ranking of lacunar status in subjects who had small vessel disease, clear increase in spaces of Virchow-Robin, lacunar infarctions or WMH. These results were more significant in males than in females revealing vulnerability particularly in the frontal atrophy in men. In turn the size of Corpus Callosum because reduced due to the compression of the lateral and third ventricles. These indicators had expression particularly in individuals over 65 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of stem cells is a promising therapeutic approach for the substantial challenge to regenerate cartilage. Considering the two prerequisites, namely the use of a 3D system to enable the chondrogenic differentiation and growth factors to avoid dedifferentiation, the diffusion efficiency of essential biomolecules is an intrinsic issue. We already proposed a liquified bioencapsulation system containing solid microparticles as cell adhesion sites1. Here, we intend to use the optimized system towards chondrogenic differentiation by encapsulating stem cells and collagenII-TGF-β3 PLLA microparticles. As a proof-of-concept, magnetite-nanoparticles were incorporated into the multilayered membrane. This can be a great advantage after implantation procedures to fixate the capsules in situ with the held of an external magnetic patch and for the follow-up through imaging. Results showed that the production of glycosaminoglycans and the expression of cartilage-relevant markers (collagen II, Sox9, aggrecan, and COMP) increased up to 28 days, while hypertrophic (collagen X) and fibrotic (collagen I) markers were downregulated. The presence of nanofibers in the newly deposited ECM was visualized by SEM, which resembles the collagen fibrils of native cartilage. The presence of the major constituent of cartilage, collagen II, was detected by immunocytochemistry and afranin-O and alcian blue stainings revealed a basophilic ECM deposition, which is characteristic of neocartilage. These findings suggest that the proposed system may provide a suitable environment for chondrogenic differentiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the experience of the implementation of a new mechanism to assess individual student contribution within project work, where students work in teams to solve a large-scale open-ended interdisciplinary project. The study takes place at the University of Minho, with first year engineering students, enrolled in the Industrial Management and Engineering (Integrated Masters) degree. The aim of this paper is to describe the main principles and procedures underlying the assessment mechanism created and also provide some feedback from its first implementation, based on the students, lecturers and tutors perceptions. For data collection, a survey was sent to all course lecturers and tutors involved in the assessment process. Students also contributed with suggestions, both on a workshop held at the end of the project and also by answering a survey on the overall satisfaction with PBL experience. Findings show a positive level of acceptance of the new mechanism by the students and also by the lecturers and tutors. The study identified the need to clarify the criteria used by the lecturers and the exact role of the tutor, as well as the need for further improvement of its features and procedures. Some recommendations are also issued regarding technical aspects related to some of the steps of the procedures, as well as the need for greater support on the adjustment and final setting of the individual grades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PhD Thesis in Sciences Specialization in Chemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymer based scintillator composites have been produced by combining polystyrene (PS) and Gd2O3:Eu3+ scintillator nanoparticles. Polystyrene has been used since it is a flexible and stable binder matrix, resistant to thermal and light deterioration and with suitable optical properties. Gd2O3:Eu3+ has been selected as scintillator material due to its wide band gap, high density and visible light yield. The optical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. Additionally 1wt.% of 2,5 dipheniloxazol (PPO) and 0.01wt.% of (1,4-bis(2-(5-phenioxazolil))-benzol (POPOP) were introduced in the polymer matrix in order to strongly improve light yield, i.e. the measured intensity of the output visible radiation, under X-ray irradiation. Whereas increasing scintillator filler concentration (from 0.25wt.% to 7.5wt.%) increases scintillator light yield, decreases the optical transparency of the composite. The addition of PPO and POPOP, strongly increased the overall 2 transduction performance of the composite due to specific absorption and re-emission processes. It is thus shown that Gd2O3:Eu3+/PPO/POPOP/PS composites in 0.25 wt.% of scintillator content with fluorescence molecules is suitable for the development of innovate large area X-ray radiation detectors with huge demand from the industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The therapeutic effects of transcranial magnetic stimulation (TMS) and transcranial direct current stimulation in patients with major depression have shown promising results; however, there is a lack of mechanistic studies using biological markers (BMs) as an outcome. Therefore, our aim was to review noninvasive brain stimulation trials in depression using BMs. Methods: The following databases were used for our systematic review: MEDLINE, Web of Science, Cochrane, and SCIELO. We examined articles published before November 2012 that used TMS and transcranial direct current stimulation as an intervention for depression and had BM as an outcome measure. The search was limited to human studies written in English. Results: Of 1234 potential articles, 52 articles were included. Only studies using TMS were found. Biological markers included immune and endocrine serum markers, neuroimaging techniques, and electrophysiological outcomes. In 12 articles (21.4%), end point BM measurements were not significantly associated with clinical outcomes. All studies reached significant results in the main clinical rating scales. Biological marker outcomes were used as predictors of response, to understand mechanisms of TMS, and as a surrogate of safety. Conclusions: Functional magnetic resonance imaging, single-photon emission computed tomography, positron emission tomography, magnetic resonance spectroscopy, cortical excitability, and brain-derived neurotrophic factor consistently showed positive results. Brain-derived neurotrophic factor was the best predictor of patients’ likeliness to respond. These initial results are promising; however, all studies investigating BMs are small, used heterogeneous samples, and did not take into account confounders such as age, sex, or family history. Based on our findings, we recommend further studies to validate BMs in noninvasive brain stimulation trials in MDD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bulimia nervosa (BN) is an eating disorder characterized by recurrent episodes of binge eating and inappropriate compensatory behaviors (such as purging, fasting, or excessive exercise) to prevent weight gain. BN has been associated with deficits in inhibitory control processes. The basal ganglia specifically, the nucleus accumbens (NAc) and the caudate nucleus (CN) are part of the frontostriatal circuits involved in inhibitory control. The main goal of this study was to investigate the presence of morphological alterations in the NAc and the CN in a sample of patients diagnosed with BN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preclinical development of nanomedicines raises several challenges and requires a comprehensive characterization. Among them is the evaluation of the biodistribution following systemic administration. In previous work, the biocompatibility and in vitro targeting ability of a glycol chitosan (GC) based nanogel have been validated. In the present study, its biodistribution in the mice is assessed, using near-infrared (NIR) fluorescence imaging as a tool to track the nanogel over time, after intravenous administration. Rapid whole body biodistribution of both Cy5.5 labeled GC nanogel and free polymer is found at early times. It remains widespreadly distributed in the body at least up to 6 h postinjection and its concentration then decreases drastically after 24 h. Nanogel blood circulation half-life lies around 2 h with the free linear GC polymer presenting lower blood clearance rate. After 24 h, the blood NIR fluorescence intensity associated with both samples decreases to insignificant values. NIR imaging of the organs shows that the nanogel had a body clearance time of 48 h, because at this time point a weak signal of NIR fluorescence is observed only in the kidneys. Hereupon it can be concluded that the engineered GC nanogel has a fairly long blood circulation time, suitable for biomedical applications, namely, drug delivery, simultaneously allowing efficient and quick body clearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate cardiac findings in 31 Noonan syndrome patients. METHODS: Thirty-one (18 males and 13 females)patients from 26 families affected with Noonan's syndrome were evaluated from the cardiac point of view with electrocardiography and echodopplercardiography. RESULTS: Twenty patients had some type of cardiac abnormality. The most frequent was pulmonary valve stenosis followed by hypertrophic myocardiopathy, commonly associated with valve defects. Upper deviation of the QRS axis was observed in 80% of these patients. CONCLUSION: In view of the high frequency and diversity of cardiac abnormalities present in Noonan syndrome, cardiac evaluation with electrocardiography and echocardiography should be performed in all patients diagnostically suspected of having this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Published online before print November 20, 2015"

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.