830 resultados para Humeral supracondylar fractures


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 15-month-old DSH cat was presented with facial deformity secondary to multiple oral and maxillofacial fractures after being struck by an automobile. Multiple wires and dental acrylics were used for fracture repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos). Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8); fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8). Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz) de baixa intensidade (30mW cm-2), aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (P<0,001 e alfa=0,05) entre as médias dos parâmetros de tempo para consolidação óssea observadas nos animais dos grupos tratado (média de 67,5 dias) e controle (média de 106 dias). Este protocolo de estimulação ultra-sônica promoveu sinais clínicos e radiográficos acelerados da consolidação óssea nas fraturas tratadas. Os resultados deste estudo sugerem que o ultra-som pulsado de baixa intensidade pode ser indicado como terapia adjuvante de fraturas diafisárias recentes em cães.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi o de estudar a resistência à corrosão em placas de aço inoxidável 316L, com diferentes tipos de acabamento e tratamento superficial, e a possível interferência dessa reação corrosiva na consolidação óssea. Utilizaram-se placas semi-acabadas, polidas, tratadas com jatos de microesferas de vidro e passivadas, as quais foram aplicadas na epífise distal do rádio de cães. Foram utilizados 12 animais, divididos em dois grupos, nos quais, após osteotomia bilateral do rádio e ulna, foram realizadas osteossínteses do rádio, totalizando 24 procedimentos. Avaliou-se a evolução clínica e radiográfica das regiões que receberam os implantes aos 30, 60, 90, 180, 240 e 360 dias. Os animais do grupo 1 (GI) foram sacrificados aos 180 dias e os do GII aos 360 dias para estudo histológico e de microscopia eletrônica de varredura do local da osteotomia sob a região dos implantes metálicos e para estudo da resistência à corrosão no organismo, pelos implantes metálicos, por meio de análises química e metalográfica (microscopia óptica e eletrônica de varredura e espectroscopia de espalhamento de energia por raios X). Os animais recuperaram a função dos membros operados 24 horas após a cirurgia. Radiograficamente, verificou-se a consolidação óssea em todos os animais. Macro e microscopicamente não foram observados sinais de corrosão nos implantes metálicos, exceto em uma placa passivada, aplicada no rádio esquerdo de um animal, na qual a corrosão foi detectada pela microscopia óptica e eletrônica de varredura. Este estudo permite concluir que as placas de aço inoxidável 316L, independente do acabamento superficial a que foram submetidas, não sofreram corrosão ou reações adversas e foram efetivas no tratamento das fraturas experimentais do rádio e ulna de cães.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A osteocondrite dissecante da cabeça do úmero (OCD) é uma condição patológica da cartilagem articular, decorrente de distúrbio da ossificação endocondral. Foram analisados 36 casos de OCD em cães com idades compreendidas entre 5 e 24 meses, observando-se maior representação entre machos comparados com fêmeas (3,5:1). A maioria destes animais (80,6%) tinha recebido suplementação alimentar. Oito cães foram tratados conservativamente através de repouso e restrição alimentar, enquanto os demais foram submetidos a intervenção cirúrgica por meio de artrotomia e remoção do retalho de superfície articular da cabeça do úmero. Concluiu-se que a predisposição de algumas raças, associada ao desequilíbrio nutricional durante os primeiros meses de vida, são as causas determinantes da OCD, e que a cirurgia é a melhor terapia a ser empregada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Doria, R.G.S.; Canola, P.A.; Freitas, S.H. & Canola, J.C. [Equine chronic proliferative synovitis (villonodular synovitis): clinical, radiographic and ultrasonographic aspects: Relate of case.] Sinovite proliferativa cronica (sinovite vilonodular) em equino: aspectos clinicos, radiograficos e ultra-sonograficos: Relato de caso. Revista Brasileira de Medicina Veterinciria 30(3):157-161, 2008. Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Cuiaba, UNIC, Av. Antartica 788, Casa 26, Residencial Villas Boas, Ribeirao da Ponte, Cuiaba, MT 78040-500. Brasil. E-mail: redoria@uol.com.brThe development of intracapsullar masses at the dorsal aspect of the metacarpofalangeal joint for a period of several months is commonly secondary to the chronic synovitis. Although it is known as villonodular synovitis in horses probably is better to refer it as chronic proliferative synovitis. The most common causes are the non-treated osteocondral fractures of the dorsal portion of the proximal phalanx. In addition, the development of villonodular masses follows the degenerative process in the joint. A case of a lame animal is reported at the present study. The correct diagnosis and the adequate therapeutic propositions were given based on the clinical examination, therapeutic local-anesthetic test and radioghaphic and ultrasonographic imaging exams. The development of a criterious identification of this disease must be based on clinical findings, radiographic and ultrasonographic exams which assume fundamental importance to the treatment and prognostic. The aim of this study is to describe the clinical, radiographic and ultrasonographic findings' allowing the identification and diagnosis of chronic proliferative synovitis at the thoracic metacarpofalangeal joint in the horse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O The aim of this study was to characterize the occurrence of trauma in the elderly population served by the mobile pre-hospital service, in Natal, Rio Grande do Norte. This is a descriptive, transversal and quantitative approach and whose population consisted of 2,080 trauma victims. The sample, of systematic random type, consisted of 400 elderly people, aged from 60 years old, assisted by the Office of Mobile Emergency in Natal / RN, between January 2011 and December 2012. Data collection began after consent and assent of the institution of a Research Ethics Committee under No. 309 505. It was proceeded to documentary retrospective analysis of records of this service through a form of self-development, validated by expert judges considered reliable (α> 0.75) and valid (CVI = 0.97) in their clarity and relevance. Data were tabulated by the Statistical Package for Social Sciences, version 20.0. The results show that older victims have an average age of 74.19 years old, with a prevalence of female involvement by chronic diseases, especially hypertension, average usage of 2.2 routine medications with vital signs within normal limits. The trauma prevailed during the daytime, in the residence of the victims, north of the city and on weekends. Among the mechanisms of trauma were falls, traffic accidents and physical aggression, whose most common type was brain-cerebral trauma and the main consequences were suture wounds and closed fractures. Basic Support Units were as more driven to pre-hospital care (87.8%) and the main destination place consisted of a referral hospital for emergency of the state (57.5%). Among the most commonly performed procedures by nursing staff immobilization with rigid board and neck collar and the peripheral venipuncture, and the main component used for volume replacement to saline were highlighted. There was a significant relationship between the deaths and the mechanism of injury, mechanism of injury and procedures, except medication administration procedures carried out, except immobilization and unit for service. It is highlighted the prevalence of trauma in the elderly, poor follow-up Pre-Hospital Trauma Life Support protocol and the paucity of records and nursing procedures performed. There is need for a protocol of care specific to elderly trauma victims and education strategies for the prevention of such events

Relevância:

10.00% 10.00%

Publicador:

Resumo:

All around the world, naturally occurring hydrocarbon deposits, consisting of oil and gas contained within rocks called reservoir rocks , generally sandstone or carbonate exists. These deposits are in varying conditions of pressure and depth from a few hundred to several thousand meters. In general, shallow reservoirs have greater tendency to fracture, since they have low fracture gradient, ie fractures are formed even with relatively low hydrostatic columns of fluid. These low fracture gradient areas are particularly common in onshore areas, like the Rio Grande do Norte basin. During a well drilling, one of the most favorable phases for the occurrence of fractures is during cementing, since the cement slurry used can have greater densities than the maximum allowed by the rock structure. Furthermore, in areas which are already naturally fractured, the use of regular cement slurries causes fluid loss into the formation, which may give rise to failures cementations and formation damages. Commercially, there are alternatives to the development of lightweight cement slurries, but these fail either because of their enormous cost, or because the cement properties were not good enough for most general applications, being restricted to each transaction for which the cement paste was made, or both reasons. In this work a statistical design was made to determine the influence of three variables, defined as the calcium chloride concentration, vermiculite concentration and nanosilica concentration in the various properties of the cement. The use of vermiculite, a low density ore present in large amounts in northeastern Brazil, as extensor for cementing slurries, enabled the production of stable cements, with high water/cement ratio, excellent rheological properties and low densities, which were set at 12.5 lb / gal, despite the fact that lower densities could be achieved. It is also seen that the calcium chloride is very useful as gelling and thickening agent, and their use in combination with nanosilica has a great effect on gel strength of the cement. Hydrothermal Stability studies showed that the pastes were stable in these conditions, and mechanical resistance tests showed values of the order of up to 10 MPa

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has as object of study the Hospital de Caridade Juvino Barreto, nosocomial institution located in the city of Natal (RN), between the Praia de Areia Preta and the Monte Petrópolis, focusing on the period from 1909, the year in which the new hospital building was constructed and opened, and 1927, the date of the transfer of administration of the public domain to the newly created Sociedade de Assistência Hospitalar (SAH). We study the conditions of possibility of the emergence of this hospital space in the urban environment of the capital of Rio Grande do Norte, seeking to understand the different tactics and strategies implemented by the historical subjects involved in the formation of this institution nosocomial. Starting from a corpus of documents consisting of medical memories (with Dr. Januário Cicco as privileged observer), information present in newspapers (the Republic and the Christmas Journa l), photo collection and extensive administrative and legal material (Speeches, Exhibitions, Reports, Laws and Resolutions), we analyzed in detail the medical geography of HCJB, relating the discourses of medicine and geography in choosing the spatial location of the hospital as we examine the architecture of the hospital, its inner spat iality, divisions, forms of space control, and, finally, we discuss the medical practices that took place within it, leading us in this regard, from the experiences of clinical hospital chief, Dr. Januário Cicco, especially the discussion on "ethics" in hospital work. The perception of HCJB as medical nosoespaciality always on the move, incorporated under taxonomic principles based on difference and dispersion forces, led us to articulate it theoretically from the conceptual-methodological arsenal of philosopher Michel Foucault, particularly his reflections of genealogical phase, focusing on the phenomenon of power, a position that allows us to enhance our space-hospital construction, invention, product of power relations, which give the unfinished aspect nosocômio, apparent, always at stake, perpetual non-modeling possibility has previously defined array, establishing it at the field of possible, of virtuality, of power: hospital that could have been and that it was not. Indeed, the investigation of various aspects/elements of hospital space Juvino Barreto revealed us new dimensions of hospital space, far more complex than the simple and the current idea of a place to shelter patients: plasticity and fluidity of space, which is not made to circumscribe the limits of empeiria, engraving up to strength relations fought between different subject; its Constitution as a transitional space, Heterotopic, doing live inside modern elements with premoderns (professional doctors working with religious thought, skeptical of positivist medicine living with the religious faith of the nuns of Santana); the impossibility of thinking hospital space of HCJB while homogeneous unit, static, transistoric, making the spatiality, without considering the profound differences, fractures and dislocations that animated his own existence, multiplying their expressions of identity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method has been developed to obtain quantitative information about grain size and shape from fractured surfaces of ceramic materials. One elaborated a routine to split intergranular and transgranular grains facets of ceramic fracture surfaces by digital image processing. A commercial ceramic (ALCOA A-16, Al2O3-1.5% of CrO) was used to test the proposed method. Microstructural measurements of grain shape and size taken from fracture surfaces have been compared through descriptive statistics of distributions, with the corresponding measurements from polished and etched surfaces. The agreement between results, with the expected bias on grain size values from fractures, obtained for both types of surfaces allowed to infer that this new technique can be used to extract the relevant microstructural information from fractured surfaces, thus minimising the time consuming steps of sample preparation. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fiber reinforced polymer composites have been widely applied in the aeronautical field. However, composite processing, which uses unlocked molds, should be avoided in view of the tight requirements and also due to possible environmental contamination. To produce high performance structural frames meeting aeronautical reproducibility and low cost criteria, the Brazilian industry has shown interest to investigate the resin transfer molding process (RTM) considering being a closed-mold pressure injection system which allows faster gel and cure times. Due to the fibrous composite anisotropic and non homogeneity characteristics, the fatigue behavior is a complex phenomenon quite different from to metals materials crucial to be investigated considering the aeronautical application. Fatigue sub-scale specimens of intermediate modulus carbon fiber non-crimp multi-axial reinforcement and epoxy mono-component system composite were produced according to the ASTM 3039 D. Axial fatigue tests were carried out according to ASTM D 3479. A sinusoidal load of 10 Hz frequency and load ratio R = 0.1. It was observed a high fatigue interval obtained for NCF/RTM6 composites. Weibull statistical analysis was applied to describe the failure probability of materials under cyclic loads and fractures pattern was observed by scanning electron microscopy. (C) 2010 Published by Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In socio-environmental scenario increased the nature resources concern beyond products and subproducts reuse. Recycling is the approach for a material or energy reintroducing in productive system. This method allows the reduction of garbage volume dumped in environment, saving energy and decreasing the requirement of natural resources use. In general, the ending of expanded polystyrene is deposited sanitary landfills or garbage dumps without control that take large volume and spreads easily by aeolian action, with consequently environmental pollution, however, the recycling avoids their misuse and the obtainment from petroleum is reduced. This work recycled expanded polystyrene via merger and/or dissolution by solvents for the production of integrated circuits boards. The obtained material was characterized in flexural mode according to ASTM D 790 and results were compared with phenolite, traditionally used. Specimens fractures were observed by electronic microscopy scanning in order to establish patterns. Expanded Polyestirene recycled as well as phenolite were also thermo analyzed by TGA and DSC. The method using dissolution produced very brittle materials. The method using merger showed no voids formation nor increased the brittleness of the material. The recycled polystyrene presented a strength value significantly lower than that for the phenolite. (C) 2011 Published by Elsevier Ltd. Selection and peer-review under responsibility of ICM11

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were used in mechanical test. The samples were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 were represented by the standard technique with two straight miniplates parallel to each other. Groups 2 and 5 were stabilized by squared miniplates and groups 3 and 6 were fixed by rectangular design. Each group was subjected to a mechanical test at a displacement speed of 10 mm/min on a universal testing machine, receiving linear vertical load on the region of the left first molar. The values of the maximum load and when displacements reached 5 mm were obtained and statistically analyzed by calculating the confidence interval of 95%. Fixation systems using squared (G2) and rectangular (G3) miniplates obtained similar results. No statistically significant differences with respect to the maximum load and the load at 5 mm displacement were found when compared to standard method in symphyseal fractures (G1). In parasymphysis the fixation method using squared miniplates (G5) obtained results without significant differences regarding the maximum load and the load at 5 mm when compared to the standard configuration (G4). The fixation method using rectangular miniplates (G6) showed inferior results which were statistically significant when compared to the standard configuration (G4) for parasymphysis fractures. The mechanical behavior of the fixation methods was similar, except when rectangular miniplates were used. The fixation methods showed better results with statistical significance in symphyseal fractures

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o método de Ulson de fixação intramedular associado à fixação externa variando a altura do travamento externo dos fios de Kirschner e sem fixação externa. MÉTODO: Foram utilizadas 18 tíbias de porcos, sendo realizada osteotomia transversal na região da tuberosidade e introduzidos dois fios de Kirschner intramedulares em cada peça, em três diferentes padrões de montagem: grupo I - travamento com minifixador externo com 3,0cm de altura; grupo II - travamento com 4,5cm de altura; grupo III: sem travamento externo. Realizaram-se ensaios mecânicos de cisalhamento, obtendo-se: carga máxima, limite de proporcionalidade e coeficiente de rigidez. RESULTADOS: Não foram encontradas diferenças significativas de carga máxima e limite de proporcionalidade entre os grupos; o grupo II apresentou maior coeficiente de rigidez. CONCLUSÃO: A altura do travamento dos fios de Kirschner no método de Ulson, dentro dos limites avaliados, não prejudicou a estabilidade do sistema de fixação da fratura.