849 resultados para Hot filament CVD


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the work described in the present paper, an analytical solution of the general heat conduction equation was employed to assay the temperature profile inside a solid slab which is initially at room temperature and is suddenly plunged into a fluid maintained at a high temperature. The results were then extrapolated to a simulation of a hot modulus of rupture test of typical MgO-graphite refractory samples containing different amounts of graphite in order to evaluate how fast the temperature equilibrates inside the test specimens. Calculations indicated that, depending on the graphite content, the time to full temperature homogenization was in the range of 80 to 200 s. These findings are relevant to the high temperature testing of such refractories in oxidizing conditions in view of the graphite oxidation risks in the proper evaluation of the hot mechanical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new model for the representation of the electrodes filaments of fluorescent lamps, during their preheating, and an analysis capable to guide the design of the preheating process in electronic ballasts. The main improvement obtained with the lamp model is the accurate theoretical reproduction of the behavior of the Rh/Rc ratio during the preheating process. In addition, using the proposed methodology based on the lamp model, it is possible to set a proper preheating process to the electrodes filaments, without the necessity of exhaustive empirical adjustments in the prototype, reducing time and costs involved in the design of ballasts with preheating capabilities. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growing demand for steels with tighter compositional specifications led the Companhia Siderúrgica Nacional (CSN) to develop more efficient processes. To solve this problem this paper aims to identify the operational variables more impacting in the desulfurization process, specifically in torpedo car, as well as its causes and solutions. Then select and test, with laboratorial and industrial tests, desulfurizing agents based of CaC 2, CaO, CaCO3, and Mg to assess the cost per quantity of product desulfurized. The mixture with best results was not that one with highest content of CaC2. It is believed that this mixture showed better efficiency because of the increased agitation of the bath, produced by the releasing of gas from compound CaCO3 present in this mixture. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports our initial research to obtain SrWO4 microcrystals by the injection of ions into a hot aqueous solution and their photocatalytic (PC) properties. These microcrystals were structurally characterized by X-ray diffraction (XRD), Rietveld refinements and Fourier transform (FT)-Raman spectroscopy. The shape and average size of these SrWO 4 microcrystals were observed by field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). In addition, we have investigated the PC activity of microcrystals for the degradation of rhodamine B (RhB) and rhodamine 6G (Rh6G) dyes. XRD patterns, Rietveld refinement data and FT-Raman spectroscopy confirmed that SrWO4 microcrystals have a scheelite-type tetragonal structure without deleterious phases. FT-Raman spectra exhibited 12 Raman-active modes in a range from 50 to 1000 cm-1. FE-SEM and TEM images suggested that the SrWO4 microcrystals (rice-like - 95%; star-, flower-, and urchin-like - 5%) were formed by means of primary/secondary nucleation events and self-assembly processes. Based on these FE-SEM/TEM images, a crystal growth mechanism was proposed and discussed in details in this work. Finally, a good PC activity was first discovered of the SrWO4 microcrystals for the degradation of RhB after 80 min and Rh6G after 50 min dyes under ultraviolet-light, respectively. © 2012 The Society of Powder Technology Japan. Published by Elsevier B.V. and The Society of Powder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to evaluate the morphologic modifications in tissues of the fruit and seed of the crambe (Crambe abyssinica Hochst. Ex R.E. Fr.) after drying at different temperatures. Fruits with a water content of 0.38 kg water/kg dry matter were harvested and manually homogenized. Drying was accomplished at 35, 45, 60, 75, and 90°C and at 21,9,7,5, and 2% relative humidity, respectively. After drying, the structure of the pericarp and tegument of the seed were evaluated and the embryo was removed from the fruit/seed for morphological analysis (structural and ultrastructural and the histolocalization of reserve substances). Drying at different temperatures did not affect the cellular structure of the tissues composing the pericarp of the fruits, but it disorganized the structure of the seed tegument. The cells of the tegument and cotyledons presented a contraction in their volumes. The lowest contractions in the cellular volumes of both the tegument and cotyledons occurred after drying at 35 and 45°C. The cytoplasm of the cotyledon cells contains oil drops and the protein bodies contain protein granules and starch grains. There were no changes in the cellular walls of the embryos of the fruits dried at different temperatures; however, ungluing of the medium lamella occurred. This damage occurred with greater intensity after drying at temperatures above 60°C. The form of the oil drops in the cytoplasm of the cotyledon cells was altered after drying. At temperatures above 60°C, the drops broke up and coalesced. After drying at 45 and 60°C, the form of some protein bodies was altered, whereas at 75 and 90°C coalescence of the protein bodies occurred in some cells. It was concluded that the identified alterations can affect the physiologic quality of crambe seeds. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a charged Brownian gas under the influence of external, static and uniform electric and magnetic fields, immersed in a uniform bath temperature. We obtain the solution for the associated Langevin equation, and thereafter the evolution of the nonequilibrium temperature towards a nonequilibrium (hot) steady state. We apply our results to a simple yet relevant Brownian model for carrier transport in GaAs. We obtain a negative differential conductivity regime (Gunn effect) and discuss and compare our results with the experimental results. © 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conditioned suppression is an animal model of anxiety disorders that has been broadly used to investigate the behavioral effects of different drugs. However, various methodological variables (e.g., the type of aversive stimulus) that supposedly interfere with the acquisition of conditioned suppression may also contribute to conflicting results among the studied drugs. Additionally, few studies have sought to investigate the effects of selective serotonin reuptake inhibitors (SSRIs). The present study investigated the effect of subchronic 5-day administration of 5 mg/kg fluoxetine in the retention of conditioned suppression produced by a hot air blast (HAB). The subjects were 12 albino Wistar rats distributed into an Experimental Group (EG) and Control Group (CG). After sessions were conducted to pair two stimuli, a sound and HAB, fluoxetine (EG) or saline (CG) was administered. Twentyfour hours after the last injection, a test session was conducted. The results showed no difference between groups. Fluoxetine (5 mg/kg) did not exert anxiolytic effects in this model of conditioned suppression produced by a HAB. Keywords: conditioned suppression; fluoxetine; subchronic; hot air blast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho, foi realizada análise comparativa dentinária após preparos com pontas diamantadas em alta rotação e pontas diamantadas CVD em ultrasom, associados ao condicionamento ácido em concentrações diferentes, para avaliar a quantidade de smear layer produzida e a obstrução de túbulos dentinários .Foram utilizados 30 incisivos bovinos, distribuídos em 3 grupos de 10 amostras, sendo avaliados os preparos entre si, os preparos associados ao condicionamento ácido dentinário em gel a 37%, e os preparos associados a condicionamento ácido dentinário em gel a 15%. As amostras foram analisadas através de microscopia eletrônica de varredura. Foi verificada diferença estatística entre os sistemas, sugerindo que, comparativamente, as pontas CVD em ultrssom proporcionaram formação de menor quantidade de smear layer nos três grupos, e maior quantidade de túbulos dentinários desobstruídos entre preparos e condicionamento dentinário.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study attempted to observe the performance of three types of diamonds, two natural and one synthetic, to determine which features longer life and greater wear than the others. The methodology employed in this study was to dressed an aluminum oxide grinding wheel, and every twenty paces with a advance of depth dressing of 40 µm per passes, take an image of the tip in a horizontal position and the other in the vertical position of this diamond in a stereoscopic. Thereafter, the dresser was replaced in the rectifier to conduct a new dressing. The criteria to completion of the test was the spark generated by the grinding wheel contact with the base of the dresser, which indicates the end of the contact with the diamond wheel. After the tests, was calculated the areas worn of each diamond in accordance with each image obtained through the aid of a graphics software. The data were then arranged in graphs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A possible way for increasing the cutting tool life can be achieved by heating the workpiece in order to diminish the shear stress of material and thus decrease the machining forces. In this study, quartz electrical resistances were set around the workpiece for heating it during the turning. In the tests, heat-resistant austenitic alloy steel was used, hardenable by precipitation, mainly used in combustion engine exhaustion valves, among other special applications for industry. The results showed that in the hot machining the cutting tool life can be increased by 340% for the highest cutting speed tested and had a reduction of 205% on workpiece surface roughness, accompanied by a force decrease in relation to conventional turning. In addition, the chips formed in hot turning exhibited a stronger tendency to continuous chip formation indicating less energy spent in material removal process. Microhardness tests performed in the workpieces subsurface layers at 5 m depth revealed slightly higher values in the hot machining than in conventional, showing a tendency toward the formation of compressive residual stress into plastically deformed layer. The hot turning also showed better performance than machining using cutting fluid. Since it is possible to avoid the use of cutting fluid, this machining method can be considered better for the environment and for the human health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil CO2 efflux is the primary source of CO2 emissions from terrestrial ecosystems to the atmosphere. The rates of this flux vary in time and space producing hot moments (sudden temporal high fluxes) and hot spots (spatially defined high fluxes), but these high reaction rates are rarely studied in conjunction with each other. We studied temporal and spatial variation of soil CO2 efflux in a water-limited Mediterranean ecosystem in Baja California, Mexico. Soil CO2 efflux increased 522% during a hot moment after rewetting of soils following dry summer months. Monthly precipitation was the primary driver of the seasonal trend of soil CO2 efflux (including the hot moment) and through changes in soil volumetric water content (VWC) it influenced the relationship between CO2 efflux and soil temperature. Geostatistical analyses showed that the spatial dependence of soil CO2 efflux changed between two contrasting seasons (dry and wet). During the dry season high soil VWC was associated with high soil CO2 efflux, and during the wet season the emergence of a hot spot of soil CO2 efflux was associated with higher root biomass and leaf area index. These results suggest that sampling designs should accommodate for changes in spatial dependence of measured variables. The spatio-temporal relationships identified in this study are arguably different from temperate ecosystems where the majority of soil CO2 efflux research has been done. This study provides evidence of the complexity of the mechanisms controlling the spatio-temporal variability of soil CO2 efflux in water-limited ecosystems. (C) 2014 Elsevier Ltd. All rights reserved.