883 resultados para Green energy sources


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Because of global warming the energy production development has progressed towards more renewable energy sources. Biomass has great potential in this matter and pellet is already a big market that has increased seven times the past decade. A periodically strained woodchip resource market and statements of short supply in the future has got actors exploring opportunities with other commodities. Grasses such as Canary grass has shown great potential in this matter and in this study a wetland grass is tested as an additive, 0,5, 1,0, 1,5, and 1,9%, with spruce woodchips. The test production series was performed at a production unit located at the department of environmental and energy system at Karlstad University, Karlstad. Quality was controlled accordingly to the European standard and parameters such as energy consumption, moisture content, mechanical durability and bulk density was tested. For comparison, a sample with only spruce wood chips was produced, and a sample containing 1% of a commonly used additive, potato starch. The results showed that a decrease in energy consumption with 14% when 2% wetland grass was added, part of the decline may be due to the increased production flow compared with the reference sample. The positive effects on decrease in energy consumption, that 1% potato starch results in, is equal to reults from 1% wetlandgrass. This indicates lubricating properties in wetlandgrass. This is attributed to that herbaceous plants have a high content of extracts such as waxes and that they cause less friction in the press. Tests also showed that pellet with wetland grass did not qualify the European standard in terms of mechanical durability. Extracts can form a weak boundary layer in the pellet and cause this. A possible trend shows a better mechanical durability with more grass in pellets. The presence of different size of particles can be a reason. Moisture content qualifies according to the European standard but is below optimum 8%. This despite to relatively high moisture content in the mixer. Higher moisture content in the press would certainly result in a generally higher quality. Suggestions for future studies are to produce pellets with greater distribution on the wetland grass added, to easier interpret a connection. Also examine the extracts behavior with different moisture content. For a sustainable development accordingly renewable energy it is important to ensure the future commodity market for pellets. Further studies should be performed to help the development of alternative raw materials in conjunction with pellet production.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a nonlinear adaptive backstepping controlleris designed to control the bidirectional power flow (charging/discharging) of battery energy storage systems (BESSs) in a DCmicrogrid under different operating conditions. The controller isdesigned in such a manner that the BESSs can store the excess energyfrom the renewable energy sources (RESs) in a DC microgrid aftersatisfying the load demand and also feeding back the stored energyto the load when RESs are not sufficient. The proposed controller isalso designed to maintain a constant voltage at the DC bus, whereall components of DC microgrids are connected, while controllingthe power flow of BESSs. This paper considers solar photovoltaic(PV) systems as the RES whereas a diesel generator equipped witha rectifier is used as a backup supply to maintain the continuity ofpower supply in the case of emergency situations. The controller isdesigned recursively based on the Lyapunov control theory whereall parameters within the model of BESSs are assumed to beunknown. These unknown parameters are then estimated throughthe adaptation laws and whose stability is ensured by formulatingsuitable control Lyapunov functions (CLFs) at different stages ofthe design process. Moreover, a scheme is also presented to monitorthe state of charge (SOC) of the BESS. Finally, the performanceof the proposed controller is verified on a test DC microgrid undervarious operating conditions. The proposed controller ensures the DCbus voltage regulation within the acceptable limits under differentoperating conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a hybrid DC microgrid consisting of a diesel generator with a rectifier, a solar photovoltaic (PV) system, and a battery energy storage system is presented in relation to an effective power management strategy and different control techniques are adopted to power electronic interfaces. The solar PV and battery energy storage systems are considered as the main sources of energy sources that supply the load demand on a daily basis whereas the diesel generator is used as a backup for the emergency operation of the microgrid. All system components are connected to a common DC bus through an appropriate power electronics devices (e.g., rectifier systems, DC/DC converter). Also a detailed sizing philosophy of all components along with the energy management strategy is proposed. Energy distribution pattern of each individual component has been conducted based on the monthly basis along with a power management algorithm. The power delivered by the solar PV system and diesel generator is controlled via DC-DC converterand excitation controllers which are designed based on a linearquadratic regulator (LQR) technique as as proportional integral (PI)controllers. The component level power distribution is investigatedusing these controllers under fluctuating load and solar irradiationconditions and comparative results are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La presente investigación pretendió incorporar el uso intensivo de TIC en los procedimientos establecidos y necesarios en los procesos de generación, distribución y control de la energía, lo que se expresa en un manual para el sistema de gestión humana de la organización analizada. La investigación partió de un levantamiento de un estado del arte, continuó con la realización de un análisis de actitudes y aptitudes de los colaboradores, basado en propuestas teóricas y mejores prácticas existentes del medio, y, por último, concluyó con un manual de gestión humana en el que se indican las competencias en los diferentes perfiles de la organización para el uso de TIC y su aplicación, con el propósito de alinearse con las perspectivas y objetivos de la organización analizada al tener como base la perdurabilidad y la competitividad de la misma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The variability in non-dispatchable power generation raises important challenges to the integration of renewable energy sources into the electricity power grid. This paper provides the coordinated trading of wind and photovoltaic energy to mitigate risks due to the wind and solar power variability, electricity prices, and financial penalties arising out the generation shortfall and surplus. The problem of wind-photovoltaic coordinated trading is formulated as a linear programming problem. The goal is to obtain the optimal bidding strategy that maximizes the total profit. The wind-photovoltaic coordinated operation is modeled and compared with the uncoordinated operation. A comparison of the models and relevant conclusions are drawn from an illustrative case study of the Iberian day-ahead electricity market.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A exigência energética global está mais orientada para a utilização das fontes de Energias Renováveis (FERs), comprometendo e garantindo um desenvolvimento sustentável. Este trabalho tem como objetivo contribuir para o atingir das metas do PED 2011-2030, no que refere à utilização das FER, em particular do potencial eólico em Timor-Leste. Timor-Leste tem apresentado um grande interesse na política de aproveitamento de FER para alcançar a meta de longo prazo de PED 2030, comprometendo-se com o desenvolvimento sustentável através de ERs. Este trabalho pretende contribuir em particular com o estudo do aproveitamento de energia eólica. Com base no clima do vento de longo termo entre 2004 – 2012, da estação meteorológica (EM) de Díli e conjugando estes com os dados da campanha experimental de Martifer cedidos, de Dezembro 2008 - Novembro 2009, obteve-se o coeficiente de variabilidade (Cvariab.) inter-anual. Foi assim possível construir o mapa médio do vento de longo termo, com modelo atmosférico de mesoscala, numa resolução refinada de 3×3 km. Para a identificação dos locais mais favoráveis do vento, foi utilizado o modelo ArcGIS para georreferenciação do recurso. A filtragem das restrições e os constrangimentos do terreno permitiu construir o mapa do vento sustentável de Timor-Leste, por distritos, subdistritos, sucos, do enclave de Oecússi e a ilha de Atauro, o que conduziu à hierarquização de cinco zonas favoráveis (zona 1 - 5). A contribuição para o plano energético de Timor-Leste consiste em duas fases: - a 1ª fase o aproveitamento eólico em três PEs nas zonas monitorizadas (3 e 5) oriundo de dados cedidos pela Martifer, contabilizou-se um total de 424.694 MWh de produção de energia anual, tendo-se verificado o custo normalizado de energia (LCOE) no valor médio calculado de 0,046 €/kWh; - na 2ª fase a construção de acesso e o desenvolvimento de PEs nas zonas 1, 2 e 4 para o Cenário de Max-Renovável. Assim sendo, viabilizam a "Perspetiva de Utilização da Energia Eólica" no quadro do PED 2011 - 2030 de Timor-Leste, que viria reduzir o custo de produção de energia atual, e a emissão de CO2; Abstract: Prospects of Using Wind Energy in Timor-Leste The demand for global energy is more focused on the use of Reneweable Energy sources (REs), ensuring and committing itself to sustainable development. This study was prompted by the wish to contribute to the achievement the goals of the Strategic Development Plan (PED 2011-2030) regarding the use of REs, particularly the wind energy in Timor-Leste. Timor-Leste has presented a great interest in the use of renewable energy sources policy to achieve the long term goal of the PED 2030, committing to a sustainable development through renewable energy. This thesis intends to contribute in particular with the study of the use of wind energy. Based on the long term wind climate between 2004 and 2012 of the Díli weather station and combining these data with the Martifer campaign experimental data of December 2008 - November 2009, the interannual variation coefficient (Cv) was obtained. Thus, it was possible to build the map of long term average wind with atmospheric mesoscale model in a refined resolution of 3×3 km. The ArcGIS model was used for the identification of the most favorable locations of the wind for its georeferencing. The constraining of filtering and the constraints of the terrain allowed to construe the sustainable wind map of Timor-Leste in distritos, subdistritos, sucos, and also of the enclave of Oecussi and Atauro island, which led to the ranking of five favorable areas (zone 1-5) for an immediate experimental campaign of wind characterization and utilization of this resource in wind parks. The contribution to Timor-Leste's energy plan consists of two phases: - the first phase of three wind farms in zone (3 and 5) from data provided by Martifer, a total of 424,694 MWh, and levelyzed cost of electricity (LCOE) in the calculated average value of 0.046 €/kWh; - in the second phase the construction of access and development of wind farms in zones 1, 2 and 4 for the Max-Renewable Scenario. As such, they make possible the "Perspective of Wind Energy Use" in Timor Leste’s PED 2011 - 2030, which would reduce current energy production costs and CO2 emissions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The variability in non-dispatchable power generation raises important challenges to the integration of renewable energy sources into the electricity power grid. This paper provides the coordinated trading of wind and photovoltaic energy assisted by a cyber-physical system for supporting management decisions to mitigate risks due to the wind and solar power variability, electricity prices, and financial penalties arising out the generation shortfall and surplus. The problem of wind-photovoltaic coordinated trading is formulated as a stochastic linear programming problem. The goal is to obtain the optimal bidding strategy that maximizes the total profit. The wind-photovoltaic coordinated operation is modelled and compared with the uncoordinated operation. A comparison of the models and relevant conclusions are drawn from an illustrative case study of the Iberian day-ahead electricity market.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biodiesel production from waste cooking oil with methanol was carried out in the presence of poly(vinyl alcohol) with sulfonic acid groups (PVA-SO3H) and polystyrene with sulfonic acid groups (PS-SO3H), at 60°C. The PVA-SO3H catalyst showed higher catalytic activity than the PS-SO3H one. In order to optimize the reaction conditions, different parameters were studied. An increase of waste cooking oil conversion into fatty acid methyl esters with the amount of PVA-SO3H was observed. When the transesterification and esterification of WCO was carried out with ethanol over PVA-SO3H, at 60°C, a decrease of biodiesel production was also observed. The WCO conversion into fatty acid ethyl ester increased when the temperature was increased from 60 to 80°C. When different amounts of free fatty acids were added to the reaction mixture, a slight increase on the conversion was observed. The PVASO3H catalyst was reused and recycled with negligible loss in the activity.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A modification to the standard Thomson parabola spectrometer is discussed, which is designed to measure high energy (tens of MeV/nucleon), broad bandwidth spectra of multi-species ions accelerated by intense laser plasma interactions. It is proposed to implement a pair of extended, trapezoidal shaped electric plates, which will not only resolve ion traces at high energies, but will also retain the lower energy part of the spectrum. While a longer (along the axis of the undeflected ion beam direction) electric plate design provides effective charge state separation at the high energy end of the spectrum, the proposed new trapezoidal shape will enable the low energy ions to reach the detector, which would have been clipped or blocked by simply extending the rectangular plates to enhance the electrostatic deflection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to examine the buyer awareness and acceptance of environmental and energy efficiency measures in the New Zealand residential property markets. This study aims to provide a greater understanding of consumer behaviour in the residential property market in relation to green housing issues ---------- Design/methodology/approach – The paper is based on an extensive survey of Christchurch real estate offices and was designed to gather data on the factors that were considered important by buyers in the residential property market. The survey was designed to allow these factors to be analysed on a socio-economic basis and to compare buyer behaviour based on property values. ---------- Findings – The results show that regardless of income levels, buyers still consider that the most important factor in the house purchase decision is the location of the property and price. Although the awareness of green housing issues and energy efficiency in housing is growing in the residential property market, it is only a major consideration for young and older buyers in the high income brackets and is only of some importance for all other buyer sectors of the residential property market. Many of the voluntary measures introduced by Governments to improve the energy efficiency of residential housing are still not considered important by buyers, indicating that a more mandatory approach may have to be undertaken to improve energy efficiency in the established housing market, as these measures are not valued by the buyer. ---------- Originality/value – The paper confirms the variations in real estate buyer behaviour across the full range of residential property markets and the acceptance and awareness of green housing issues and measures. These results would be applicable to most established and transparent residential property markets.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper investigates cooling energy performance of commercial building before and after green roof and living wall application based on integrated building heat gain model developed from Overall Thermal Transfer Value (OTTV) of building wall and steady state heat transfer process of roof in sub-tropical climate. Using the modelled equation and eQUEST energy simulation tool, commercial building envelope parameters and relevant heat gain parameters have been accumulated to analyse the heat gain and cooling energy consumption of commercial building. Real life commercial building envelope and air-conditioned load data for the sub-tropical climate zone have been collected and compared with the modelled analysis. Relevant temperature data required for living wall and green roof analysis have been collected from experimental setup comprised of both green roof and west facing living wall. Then, Commercial building heat flux and cooling energy performance before and after green roof and living wall application have been scrutinized.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

- Problem Climate change is affecting the world in numerous ways such as increased temperatures, sea level rise, and increased droughts and floods. Governments worldwide, especially in the most vulnerable countries, are urged to seek better solutions for sustainable development. The construction industry and buildings have enormous impacts on humans and the environment, meaning green building must be one of the solutions. Government involvement is widely considered as one of the essential and most effective ways to promote green building and drive the construction market towards sustainability. This paper will review green building policy of the Pacific-Rim countries that are most vulnerable to climate change according to the recent Standard and Poor’s ranking, including: Cambodia, Vietnam, Fiji, Philippines, Papua New Guinea and Indonesia. Methodology: This paper will review policy related publications including journal and conference papers, portal websites of governments, legislation documents and reports of international organisations. It will focus on the policies and governmental instruments that support the adoption of green building practices. - Findings All six governments have launched climate change adaptation policies, showing a great concern regarding the damages caused by the phenomenon. All countries except Papua New Guinea have promulgated energy efficiency policy and programs which indirectly promote the adoption of green building practices. The comparison study shows that Philippines and Indonesia motivate the adoption of renewable energy generation, energy efficiency and green building through either financial or advocacy instruments, while other four countries tend to implement regulatory tools to mandate energy conservation. Through comparison, Cambodia and Vietnam – the two countries providing vision to develop green building - can learn from Philippines and Indonesia’s policy and instruments. - Research limitations Language differences between the countries and limit of formal sources may pose difficulties in searching for information. While much English language literature exists, sources from Cambodia, Philippines and Indonesia are less accessible. - Takeaway for practice As the paper provides more understanding about the supportive policy of those countries, it will introduce more opportunities for green property developers to invest in construction markets of those Pacific-Rim countries. - Originality There is little research reviewing green building supportive policies of developing and less-wealthy countries that are forecasted to be most vulnerable and most impacted by climate change. The originality of this paper lies in its investigation on how those countries intend to respond to this phenomenon and whether and to what extent they support the green building market by using policy tools.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The improvement terms in the generalised energy-momentum tensor of Callan, Coleman and Jackiw can be derived from a variational principle if the Lagrangian is generalised to describe coupling between ‘matter’ fields and a spin-2 boson field. The required Lorentz-invariant theory is a linearised version of Kibble-Sciama theory with an additional (generally-covariant) coupling term in the Lagrangian. The improved energy-momentum tensor appears as the source of the spin-2 field, if terms of second order in the coupling constant are neglected.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We derive exact expressions for the zeroth and the first three spectral moment sum rules for the retarded Green's function and for the zeroth and the first spectral moment sum rules for the retarded self-energy of the inhomogeneous Bose-Hubbard model in nonequilibrium, when the local on-site repulsion and the chemical potential are time-dependent, and in the presence of an external time-dependent electromagnetic field. We also evaluate these expressions for the homogeneous case in equilibrium, where all time dependence and external fields vanish. Unlike similar sum rules for the Fermi-Hubbard model, in the Bose-Hubbard model case, the sum rules often depend on expectation values that cannot be determined simply from parameters in the Hamiltonian like the interaction strength and chemical potential but require knowledge of equal-time many-body expectation values from some other source. We show how one can approximately evaluate these expectation values for the Mott-insulating phase in a systematic strong-coupling expansion in powers of the hopping divided by the interaction. We compare the exact moment relations to the calculated moments of spectral functions determined from a variety of different numerical approximations and use them to benchmark their accuracy. DOI: 10.1103/PhysRevA.87.013628