978 resultados para Generation Time Effect


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to investigate the effects on a possible improvement in aerobic and anaerobic performance of oral terbutaline (TER) at a supra-therapeutic dose in 7 healthy competitive male athletes. On day 1, ventilatory threshold, maximum oxygen uptake [Formula: see text] and corresponding power output were measured and used to determine the exercise load on days 2 and 3. On days 2 and 3, 8 mg of TER or placebo were orally administered in a double-blind process to athletes who rested for 3 h, and then performed a battery of tests including a force-velocity exercise test, running sprint and a maximal endurance cycling test at Δ50 % (50 % between VT and [Formula: see text]). Lactatemia, anaerobic parameters and endurance performance ([Formula: see text] and time until exhaustion) were raised during the corresponding tests. We found that TER administration did not improve any of the parameters of aerobic performance (p > 0.05). In addition, no change in [Formula: see text] kinetic parameters was found with TER compared to placebo (p > 0.05). Moreover, no enhancement of the force-velocity relationship was observed during sprint exercises after TER intake (p > 0.05) and, on the contrary, maximal strength decreased significantly after TER intake (p < 0.05) but maximal power remained unchanged (p > 0.05). In conclusion, oral acute administration of TER at a supra-therapeutic dose seems to be without any relevant ergogenic effect on anaerobic and aerobic performances in healthy athletes. However, all participants experienced adverse side effects such as tremors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Occupational exposure to metals such as cobalt and beryllium represents a risk factor for respiratory health and can cause immune-mediated diseases. However, the way they act may be different. We show here that the two metals have a divergent effect on peripheral T lymphocytes and monocytes: BeSO(4) induces cell death in monocytes but not in T lymphocytes, which instead respond by producing Interferon gamma (IFN-γ); conversely, CoCl(2) induces apoptosis in T lymphocytes but not in monocytes. Interestingly, both metals induce p53 overexpression but with a dramatic different outcome. This is because the effect of p53 in CoCl(2)-treated monocytes is counteracted by the antiapoptotic activity of cytoplasmic p21(Cip1/WAF1), the activation of nuclear factor κB, and the inflammasome danger signaling pathway leading to the production of proinflammatory cytokines. However, CoCl(2)-treated monocytes do not fully differentiate into macrophage or dendritic cells, as inferred by the lack of expression of CD16 and CD83, respectively. Furthermore, the expression of HLA-class II molecules, as well as the capability of capturing and presenting the antigens, decreased with time. In conclusion, cobalt keeps monocytes in a partially activated, proinflammatory state that can contribute to some of the pathologies associated with the exposure to this metal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, we assessed whether the white-coat effect (difference between office and daytime blood pressure (BP)) is associated with nondipping (absence of BP decrease at night). Data were available in 371 individuals of African descent from 74 families selected from a population-based hypertension register in the Seychelles Islands and in 295 Caucasian individuals randomly selected from a population-based study in Switzerland. We used standard multiple linear regression in the Swiss data and generalized estimating equations to account for familial correlations in the Seychelles data. The prevalence of systolic and diastolic nondipping (<10% nocturnal BP decrease) and white-coat hypertension (WCH) was respectively 51, 46, and 4% in blacks and 33, 37, and 7% in whites. When white coat effect and nocturnal dipping were taken as continuous variables (mm Hg), systolic (SBP) and diastolic BP (DBP) dipping were associated inversely and independently with white-coat effect (P < 0.05) in both populations. Analogously, the difference between office and daytime heart rate was inversely associated with the difference between daytime and night-time heart rate in the two populations. These results did not change after adjustment for potential confounders. The white-coat effect is associated with BP nondipping. The similar associations between office-daytime values and daytime-night-time values for both BP and heart rate suggest that the sympathetic nervous system might play a role. Our findings also further stress the interest, for clinicians, of assessing the presence of a white-coat effect as a means to further identify patients at increased cardiovascular risk and guide treatment accordingly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[spa] En un modelo de Poisson compuesto, definimos una estrategia de reaseguro proporcional de umbral : se aplica un nivel de retención k1 siempre que las reservas sean inferiores a un determinado umbral b, y un nivel de retención k2 en caso contrario. Obtenemos la ecuación íntegro-diferencial para la función Gerber-Shiu, definida en Gerber-Shiu -1998- en este modelo, que nos permite obtener las expresiones de la probabilidad de ruina y de la transformada de Laplace del momento de ruina para distintas distribuciones de la cuantía individual de los siniestros. Finalmente presentamos algunos resultados numéricos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

LRH and its agonists have been shown to exert both stimulatory and inhibitory effects on testicular function. In the present study, the dose and length of treatment were tested to determine the appearance of the stimulatory and inhibitory effects of LRH agonist on testicular axis including the three levels. Two doses of an agonist of LRH, 40 and 100 ng/100 g body weight (buserelin, 'agonist'), were administered daily for 1 to 15 days to adult male rats. Control rats received the vehicle only. On day 1, 2, 4, 8 and 15 of treatment, the pituitary, testicular and peripheral levels (weight of accessory sex organs and androgen receptors in ventral prostate) were tested 6 h after the last injection. For the 15 days of treatment with both doses, a stimulatory effect of the 'agonist' was observed on LH and FSH release. A short exposure (1-2 days) to the low dose of the 'agonist' had a stimulatory effect on the density of LH/hCG testicular receptors (326 +/- 49 vs control 185 +/- 21 fmol/mg protein, mean +/- SEM), on the weights of seminal vesicles and ventral prostate and exposure to both doses led to high plasma testosterone levels (13.8 +/- 0.5 and 13.7 +/- 0.7 ng/ml, respectively, vs control 2.6 +/- 0.3 ng/ml), and to an increased density of nuclear androgen receptors in the ventral prostate (142 +/- 9 and 144 +/- 15 fmol/mg protein respectively vs control 97 +/- 12 fmol/mg protein).(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A precise digital simulation of a bistable system under the effect of colored noise is carried out. A set of data for the mean first-passage time is obtained. The results are interpreted and compared with presently available theories, which are revisited following a new insight. Discrepancies that have been discussed in the literature are understood within our framework.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of a device based on modified injection-locking techniques is studied by means of numerical simulations. The device incorporates master and slave configurations, each one with a DFB laser and an electroabsortion modulator (EAM). This arrangement allows the generation of high peak power, narrow optical pulses according to a periodic or pseudorandom bit stream provided by a current signal generator. The device is able to considerably increase the modulation bandwidth of free-running gain-switched semiconductor lasers using multiplexing in the time domain. Opportunities for integration in small packages or single chips are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract : The occupational health risk involved with handling nanoparticles is the probability that a worker will experience an adverse health effect: this is calculated as a function of the worker's exposure relative to the potential biological hazard of the material. Addressing the risks of nanoparticles requires therefore knowledge on occupational exposure and the release of nanoparticles into the environment as well as toxicological data. However, information on exposure is currently not systematically collected; therefore this risk assessment lacks quantitative data. This thesis aimed at, first creating the fundamental data necessary for a quantitative assessment and, second, evaluating methods to measure the occupational nanoparticle exposure. The first goal was to determine what is being used where in Swiss industries. This was followed by an evaluation of the adequacy of existing measurement methods to assess workplace nanopaiticle exposure to complex size distributions and concentration gradients. The study was conceived as a series of methodological evaluations aimed at better understanding nanoparticle measurement devices and methods. lt focused on inhalation exposure to airborne particles, as respiration is considered to be the most important entrance pathway for nanoparticles in the body in terms of risk. The targeted survey (pilot study) was conducted as a feasibility study for a later nationwide survey on the handling of nanoparticles and the applications of specific protection means in industry. The study consisted of targeted phone interviews with health and safety officers of Swiss companies that were believed to use or produce nanoparticles. This was followed by a representative survey on the level of nanoparticle usage in Switzerland. lt was designed based on the results of the pilot study. The study was conducted among a representative selection of clients of the Swiss National Accident Insurance Fund (SUVA), covering about 85% of Swiss production companies. The third part of this thesis focused on the methods to measure nanoparticles. Several pre- studies were conducted studying the limits of commonly used measurement devices in the presence of nanoparticle agglomerates, This focus was chosen, because several discussions with users and producers of the measurement devices raised questions about their accuracy measuring nanoparticle agglomerates and because, at the same time, the two survey studies revealed that such powders are frequently used in industry. The first preparatory experiment focused on the accuracy of the scanning mobility particle sizer (SMPS), which showed an improbable size distribution when measuring powders of nanoparticle agglomerates. Furthermore, the thesis includes a series of smaller experiments that took a closer look at problems encountered with other measurement devices in the presence of nanoparticle agglomerates: condensation particle counters (CPC), portable aerosol spectrometer (PAS) a device to estimate the aerodynamic diameter, as well as diffusion size classifiers. Some initial feasibility tests for the efficiency of filter based sampling and subsequent counting of carbon nanotubes (CNT) were conducted last. The pilot study provided a detailed picture of the types and amounts of nanoparticles used and the knowledge of the health and safety experts in the companies. Considerable maximal quantities (> l'000 kg/year per company) of Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO (mainly first generation particles) were declared by the contacted Swiss companies, The median quantity of handled nanoparticles, however, was 100 kg/year. The representative survey was conducted by contacting by post mail a representative selection of l '626 SUVA-clients (Swiss Accident Insurance Fund). It allowed estimation of the number of companies and workers dealing with nanoparticles in Switzerland. The extrapolation from the surveyed companies to all companies of the Swiss production sector suggested that l'309 workers (95%-confidence interval l'073 to l'545) of the Swiss production sector are potentially exposed to nanoparticles in 586 companies (145 to l'027). These numbers correspond to 0.08% (0.06% to 0.09%) of all workers and to 0.6% (0.2% to 1.1%) of companies in the Swiss production sector. To measure airborne concentrations of sub micrometre-sized particles, a few well known methods exist. However, it was unclear how well the different instruments perform in the presence of the often quite large agglomerates of nanostructured materials. The evaluation of devices and methods focused on nanoparticle agglomerate powders. lt allowed the identification of the following potential sources of inaccurate measurements at workplaces with considerable high concentrations of airborne agglomerates: - A standard SMPS showed bi-modal particle size distributions when measuring large nanoparticle agglomerates. - Differences in the range of a factor of a thousand were shown between diffusion size classifiers and CPC/SMPS. - The comparison between CPC/SMPS and portable aerosol Spectrometer (PAS) was much better, but depending on the concentration, size or type of the powders measured, the differences were still of a high order of magnitude - Specific difficulties and uncertainties in the assessment of workplaces were identified: the background particles can interact with particles created by a process, which make the handling of background concentration difficult. - Electric motors produce high numbers of nanoparticles and confound the measurement of the process-related exposure. Conclusion: The surveys showed that nanoparticles applications exist in many industrial sectors in Switzerland and that some companies already use high quantities of them. The representative survey demonstrated a low prevalence of nanoparticle usage in most branches of the Swiss industry and led to the conclusion that the introduction of applications using nanoparticles (especially outside industrial chemistry) is only beginning. Even though the number of potentially exposed workers was reportedly rather small, it nevertheless underscores the need for exposure assessments. Understanding exposure and how to measure it correctly is very important because the potential health effects of nanornaterials are not yet fully understood. The evaluation showed that many devices and methods of measuring nanoparticles need to be validated for nanoparticles agglomerates before large exposure assessment studies can begin. Zusammenfassung : Das Gesundheitsrisiko von Nanopartikel am Arbeitsplatz ist die Wahrscheinlichkeit dass ein Arbeitnehmer einen möglichen Gesundheitsschaden erleidet wenn er diesem Stoff ausgesetzt ist: sie wird gewöhnlich als Produkt von Schaden mal Exposition gerechnet. Für eine gründliche Abklärung möglicher Risiken von Nanomaterialien müssen also auf der einen Seite Informationen über die Freisetzung von solchen Materialien in die Umwelt vorhanden sein und auf der anderen Seite solche über die Exposition von Arbeitnehmenden. Viele dieser Informationen werden heute noch nicht systematisch gesarnmelt und felilen daher für Risikoanalysen, Die Doktorarbeit hatte als Ziel, die Grundlagen zu schaffen für eine quantitative Schatzung der Exposition gegenüber Nanopartikel am Arbeitsplatz und die Methoden zu evaluieren die zur Messung einer solchen Exposition nötig sind. Die Studie sollte untersuchen, in welchem Ausmass Nanopartikel bereits in der Schweizer Industrie eingesetzt werden, wie viele Arbeitnehrner damit potentiel] in Kontakt komrrien ob die Messtechnologie für die nötigen Arbeitsplatzbelastungsmessungen bereits genügt, Die Studie folcussierte dabei auf Exposition gegenüber luftgetragenen Partikel, weil die Atmung als Haupteintrittspforte iïlr Partikel in den Körper angesehen wird. Die Doktorarbeit besteht baut auf drei Phasen auf eine qualitative Umfrage (Pilotstudie), eine repräsentative, schweizerische Umfrage und mehrere technische Stndien welche dem spezitischen Verständnis der Mëglichkeiten und Grenzen einzelner Messgeräte und - teclmikeri dienen. Die qualitative Telephonumfrage wurde durchgeführt als Vorstudie zu einer nationalen und repräsentativen Umfrage in der Schweizer Industrie. Sie zielte auf Informationen ab zum Vorkommen von Nanopartikeln, und den angewendeten Schutzmassnahmen. Die Studie bestand aus gezielten Telefoninterviews mit Arbeit- und Gesundheitsfachpersonen von Schweizer Unternehmen. Die Untemehmen wurden aufgrund von offentlich zugànglichen lnformationen ausgewählt die darauf hinwiesen, dass sie mit Nanopartikeln umgehen. Der zweite Teil der Dolctorarbeit war die repräsentative Studie zur Evalniernng der Verbreitnng von Nanopaitikelanwendungen in der Schweizer lndustrie. Die Studie baute auf lnformationen der Pilotstudie auf und wurde mit einer repräsentativen Selektion von Firmen der Schweizerischen Unfall Versicherungsanstalt (SUVA) durchgeüihxt. Die Mehrheit der Schweizerischen Unternehmen im lndustrieselctor wurde damit abgedeckt. Der dritte Teil der Doktorarbeit fokussierte auf die Methodik zur Messung von Nanopartikeln. Mehrere Vorstudien wurden dnrchgefîihrt, um die Grenzen von oft eingesetzten Nanopartikelmessgeräten auszuloten, wenn sie grösseren Mengen von Nanopartikel Agglomeraten ausgesetzt messen sollen. Dieser F okns wurde ans zwei Gründen gewählt: weil mehrere Dislcussionen rnit Anwendem und auch dem Produzent der Messgeràte dort eine Schwachstelle vermuten liessen, welche Zweifel an der Genauigkeit der Messgeräte aufkommen liessen und weil in den zwei Umfragestudien ein häufiges Vorkommen von solchen Nanopartikel-Agglomeraten aufgezeigt wurde. i Als erstes widmete sich eine Vorstndie der Genauigkeit des Scanning Mobility Particle Sizer (SMPS). Dieses Messgerät zeigte in Präsenz von Nanopartikel Agglorneraten unsinnige bimodale Partikelgrössenverteilung an. Eine Serie von kurzen Experimenten folgte, welche sich auf andere Messgeräte und deren Probleme beim Messen von Nanopartikel-Agglomeraten konzentrierten. Der Condensation Particle Counter (CPC), der portable aerosol spectrometer (PAS), ein Gerät zur Schàtzung des aerodynamischen Durchniessers von Teilchen, sowie der Diffusion Size Classifier wurden getestet. Einige erste Machbarkeitstests zur Ermittlnng der Effizienz von tilterbasierter Messung von luftgetragenen Carbon Nanotubes (CNT) wnrden als letztes durchgeiührt. Die Pilotstudie hat ein detailliiertes Bild der Typen und Mengen von genutzten Nanopartikel in Schweizer Unternehmen geliefert, und hat den Stand des Wissens der interviewten Gesundheitsschntz und Sicherheitsfachleute aufgezeigt. Folgende Typen von Nanopaitikeln wurden von den kontaktierten Firmen als Maximalmengen angegeben (> 1'000 kg pro Jahr / Unternehrnen): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, und ZnO (hauptsächlich Nanopartikel der ersten Generation). Die Quantitäten von eingesetzten Nanopartikeln waren stark verschieden mit einem ein Median von 100 kg pro Jahr. ln der quantitativen Fragebogenstudie wurden l'626 Unternehmen brieflich kontaktiert; allesamt Klienten der Schweizerischen Unfallversicherringsanstalt (SUVA). Die Resultate der Umfrage erlaubten eine Abschätzung der Anzahl von Unternehmen und Arbeiter, welche Nanopartikel in der Schweiz anwenden. Die Hochrechnung auf den Schweizer lndnstriesektor hat folgendes Bild ergeben: ln 586 Unternehmen (95% Vertrauensintervallz 145 bis 1'027 Unternehmen) sind 1'309 Arbeiter potentiell gegenüber Nanopartikel exponiert (95%-Vl: l'073 bis l'545). Diese Zahlen stehen für 0.6% der Schweizer Unternehmen (95%-Vl: 0.2% bis 1.1%) und 0.08% der Arbeiternehmerschaft (95%-V1: 0.06% bis 0.09%). Es gibt einige gut etablierte Technologien um die Luftkonzentration von Submikrometerpartikel zu messen. Es besteht jedoch Zweifel daran, inwiefern sich diese Technologien auch für die Messurrg von künstlich hergestellten Nanopartikeln verwenden lassen. Aus diesem Grund folcussierten die vorbereitenden Studien für die Arbeitsplatzbeurteilnngen auf die Messung von Pulverri, welche Nan0partike1-Agg10merate enthalten. Sie erlaubten die ldentifikation folgender rnöglicher Quellen von fehlerhaften Messungen an Arbeitsplätzen mit erhöhter Luft-K0nzentrati0n von Nanopartikel Agglomeratenz - Ein Standard SMPS zeigte eine unglaubwürdige bimodale Partikelgrössenverteilung wenn er grössere Nan0par'til<e1Agg10merate gemessen hat. - Grosse Unterschiede im Bereich von Faktor tausend wurden festgestellt zwischen einem Diffusion Size Classiîier und einigen CPC (beziehungsweise dem SMPS). - Die Unterschiede zwischen CPC/SMPS und dem PAS waren geringer, aber abhängig von Grosse oder Typ des gemessenen Pulvers waren sie dennoch in der Grössenordnung von einer guten Grössenordnung. - Spezifische Schwierigkeiten und Unsicherheiten im Bereich von Arbeitsplatzmessungen wurden identitiziert: Hintergrundpartikel können mit Partikeln interagieren die während einem Arbeitsprozess freigesetzt werden. Solche Interaktionen erschweren eine korrekte Einbettung der Hintergrunds-Partikel-Konzentration in die Messdaten. - Elektromotoren produzieren grosse Mengen von Nanopartikeln und können so die Messung der prozessbezogenen Exposition stören. Fazit: Die Umfragen zeigten, dass Nanopartikel bereits Realitàt sind in der Schweizer Industrie und dass einige Unternehmen bereits grosse Mengen davon einsetzen. Die repräsentative Umfrage hat diese explosive Nachricht jedoch etwas moderiert, indem sie aufgezeigt hat, dass die Zahl der Unternehmen in der gesamtschweizerischen Industrie relativ gering ist. In den meisten Branchen (vor allem ausserhalb der Chemischen Industrie) wurden wenig oder keine Anwendungen gefunden, was schliessen last, dass die Einführung dieser neuen Technologie erst am Anfang einer Entwicklung steht. Auch wenn die Zahl der potentiell exponierten Arbeiter immer noch relativ gering ist, so unterstreicht die Studie dennoch die Notwendigkeit von Expositionsmessungen an diesen Arbeitsplätzen. Kenntnisse um die Exposition und das Wissen, wie solche Exposition korrekt zu messen, sind sehr wichtig, vor allem weil die möglichen Auswirkungen auf die Gesundheit noch nicht völlig verstanden sind. Die Evaluation einiger Geräte und Methoden zeigte jedoch, dass hier noch Nachholbedarf herrscht. Bevor grössere Mess-Studien durgefîihrt werden können, müssen die Geräte und Methodem für den Einsatz mit Nanopartikel-Agglomeraten validiert werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

After foot and/or ankle fracture, the restoration of optimal gait symmetry is one of the criteria of recovery. Orthotic insoles and orthopaedic shoes improve gait symmetry and regularity by controlling joint motion and improving alignment. The aim of the present study was to assess the effect of prescription footwear on gait quality by using accelerometers attached to the lower back. Sixteen adult patients with persistent disability after ankle and/or foot fractures performed two 30-s walking trials with and without prescription footwear (insoles and stabilizing shoes). Sixteen control subjects were also tested for comparison. The autocorrelation function was computed from the acceleration signal and the first two dominant periods were assessed (d1 and d2). Two parameters were used: (1) Stride Regularity (SR) which expresses the similarity between strides over time (d2), and (2) Stride Symmetry (SS) a ratio (d1/d2) which expresses the left/right similarity of gait independently of repeatability in the successive movements of each limb. In control subjects, SR and SS were 0.86+/-0.05 (correlation coefficient) and 81+/-10%, respectively. In the patient group, the effect of footwear was significant (SR: 0.88+/-0.06 vs. 0.90+/-0.05, SS: 38+/-23% vs. 46+/-27%). Pain was also significantly reduced (-34%). By using a rapid and low-cost method, we objectively quantified gait quality improvement after footwear intervention, concomitant to pain reduction. Substantial inter-patient variability in the footwear outcome was observed. In conclusion, we believe that trunk accelerometry can be a useful tool in the field of gait rehabilitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coherence resonance occurring in semiconductor lasers with optical feedback is studied via the Lang-Kobayashi model with external nonwhite noise in the pumping current. The temporal correlation and the amplitude of the noise have a highly relevant influence in the system, leading to an optimal coherent response for suitable values of both the noise amplitude and correlation time. This phenomenon is quantitatively characterized by means of several statistical measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An effect of multiplicative noise in the time-dependent Ginzburg-Landau model is reported, namely, that noise at a relatively low intensity induces a phase transition towards an ordered state, whereas strong noise plays a destructive role, driving the system back to its disordered state through a reentrant phase transition. The phase diagram is calculated analytically using a mean-field theory and a more sophisticated approach and is compared with the results from extensive numerical simulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We develop an algorithm to simulate a Gaussian stochastic process that is non-¿-correlated in both space and time coordinates. The colored noise obeys a linear reaction-diffusion Langevin equation with Gaussian white noise. This equation is exactly simulated in a discrete Fourier space.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aquatic environment is exposed continuously and increasingly to chemical substances such as pharmaceuticals. These medical compounds are released into the environment after having being consumed and body-excreted by patients. Pharmaceutical residues are synthetic molecules that are not always removed by traditional sewage treatment processes and thus escape degradation. Among pharmaceuticals that escape sewage treatment plants (STPs), the anticancer drugs were measured in STP effluents and natural waters. In the aquatic environment, their long-term effects at low concentrations are sparsely known on non-target species. Tamoxifen is an anticancer drug that is widely prescribed worldwide for the prevention and treatment of hormone receptor-positive breast cancers. Two of its metabolites, i.e., endoxifen and 4-hydroxy- tamoxifen (4OHTam), have high pharmacological potency in vivo and such as tamoxifen, they are excreted via faeces by patients. Tamoxifen was measured in STP effluents and natural waters but, to the best of our knowledge, its metabolites concentrations in waters have never been reported. Imatinib is another and recent anticancer compound that targets specific tumour cells. This pharmaceutical is also body excreted and because of its increasing use in cancer treatment, imatinib may reach the natural water. The effects of tamoxifen and imatinib are unknown upon more than one generation of aquatic species. And the effects of 4OHTam, endoxifen have never been studied in ecotoxicology so far. The aims of this thesis were threefold. First, the sensitivity of D. pulex exposed to tamoxifen, 4OHTam, endoxifen or imatinib was assessed using ecotoxicological experiments. Ecotoxicology is the science that considers the toxic effects of natural or synthetic substances, such as pharmaceuticals, on organisms, populations, community and ecosystem. Acute and multigenerational (2-4 generations) tests were performed on daphnids considering several studied endpoints, such as immobilisation, size, reproduction, viability and intrinsic rate of natural increase. Additional prospective assays were designed to evaluate whether 1) low concentrations of tamoxifen and 4OHTam were able to induce toxic effects when used in combination, and 2) daphnids were able to recover when offspring were withdrawn from solutions carrying the pharmaceutical. Second, the stability of tamoxifen, 4OHTam and endoxifen in incubation medium was evaluated in solution exempted from daphnids. Because the nominal concentrations of tamoxifen, 4OHTam and endoxifen did not correspond to the measured, we provide a predictive method to estimate the concentrations of these chemicals during long-term ecotoxicological tests. Finally, changes in protein expressions were analysed in D. pulex exposed 2 or 7 seven days to tamoxifen using ecotoxicoproteomic experiments with a shot-gun approach inducing a peptide fractionation step. Our results show that tamoxifen, 4OHTam and endoxifen induced adverse effects in D. pulex at environmentally relevant concentrations. At very low concentrations, these molecules displayed unusual and teratogenic effects because morphological abnormalities were observed in offspring, such as thick and short antennas, curved spines, premature neonates and aborted eggs. Tamoxifen was the most toxic compound among the test chemicals, followed by 4OHTam, endoxifen and imatinib. Tamoxifen no-observed effect concentrations (NOECs) that were calculated for size, reproduction and intrinsic rate were below or in the range of the concentrations measured in natural waters, i.e., between 0.12 µg/L and 0.67 µg/L. For instance, the tamoxifen NOECs that were calculated for reproduction were between 0.67 and 0.72 µg/L, whereas the NOEC was < 0.15 µg/L when based on morphological abnormalities. The NOECs of 4OHTam were higher but still in the same order of magnitude as tamoxifen environmental concentrations, with a value of 1.48 µg/L. Endoxifen NOEC for the intrinsic rate of natural increase (r) and the reproduction were 0.4 and 4.3 µg/L, respectively. Daphnids that were withdrawn from tamoxifen and 4OHTam were not able to recover. Also, the reproduction of D. pulex was reduced when the treated animals were exposed to the combination of tamoxifen and 4OHTam while no effects were observed when these chemicals were tested individually at the same concentration. Among the anticancer drugs that were tested during this thesis, imatinib was the less toxic molecule towards D. pulex. No effects on size and reproduction were observed within two generations, except for the first whose reproduction decreased at the highest test concentration, i.e., 626 µg/L. Our results also underline the need to use measured or predicted concentrations instead of the nominal during aquatic experiments, particularly when lipophilic molecules are tested. Indeed, notable differences between nominal (i.e., theoretical) and measured concentrations were found with tamoxifen, 4OHTam and endoxifen at all test concentrations. A cost and time sustainable method was proposed to predict the test exposure levels of these chemicals during long-term experiments. This predictive method was efficient particularly for low concentrations, which corresponded to the test concentrations in multigenerational tests. In the ecotoxicoproteomic experiments a total of 3940 proteins were identified and quantified in D. pulex exposed to tamoxifen. These results are currently the largest dataset from D. pulex that is published and the results of proteomic analyses are available for the scientific community. Among these 3940 proteins, 189 were significantly different from controls. After protein annotation, we assumed that treated daphnids with tamoxifen had shifted cost-energy functions, such as reproduction, to maintain their basic metabolism necessary to survive. This metabolic cost hypothesis was supported by the presence of proteins involved in oxidative stress. Biomarkers for early detection of tamoxifen harmful effects on D. pulex were not discovered but the proteins of the vitellogenin-2 family (E9H8K5) and the ryanodine receptor (E9FTU9) are promising potential biomarkers because their expression was already modified after 2 days of treatment. In this thesis, the effects of tamoxifen, 4OHTam and endoxifen on daphnids raise questions about the potential impact of tamoxifen and 4OHTam in other aquatic ecosystems, and therefore, about metabolites in ecotoxicology. Because the NOECs were environmentally relevant, these results suggest that tamoxifen and 4OHTam may be interesting pharmaceuticals to consider in risk assessment. Our findings also emphasize the importance of performing long-term experiments and of considering multi-endpoints instead of the standard reproductive endpoint. Finally, we open the discussion about the importance to measure test exposures or not, during ecotoxicological studies. -- Les milieux aquatiques sont exposés continuellement à un nombre croissant de substances chimiques, notamment les médicaments issus de la médecine vétérinaire et humaine. Chez les patients, les substances administrées sont utilisées par le corps avant d'être éliminées par l'intermédiaire des excrétas dans le système d'eaux usées de la ville. Ces eaux rejoignent ensuite une station de traitement afin d'y éliminer les déchets. Dans le cas des molécules chimiques, il arrive que les processus de traitement d'eaux usées ne soient pas suffisamment efficaces et que ces molécules ne soient pas dégradées. Elles sont alors libérées dans le milieu aquatique avec les effluents de la station d'épuration. Une fois dans l'environnement, ces résidus de médicaments sont susceptibles d'induire des effets sur la faune et la flore aquatique, dont les conséquences à long terme et à faibles concentrations sont peu connues. Les anticancéreux sont une famille de médicaments qui peuvent échapper aux traitements des stations d'épuration et qui sont retrouvées dans le milieu aquatique naturel. Parmi ces substances, le tamoxifen est une molécule utilisée dans le monde entier pour prévenir et traiter les cancers hormonaux dépendant du sein, notamment. Une fois ingéré, le tamoxifen est transformé par le foie en métabolites dont deux d'entre eux, le 4-hydroxy-tamoxifen (4OHTam) et l'endoxifen, possèdent un affinité pour les récepteurs aux estrogènes et une efficacité sur les cellules tumorales supérieure au tamoxifen lui- même. Tout comme la molécule mère, ces métabolites sont principalement éliminés par l'intermédiaire des fèces. Le tamoxifen a déjà été mesuré dans les effluents de stations d'épuration et dans les eaux naturelles, mais aucune valeur n'a été reportée pour ses métabolites jusqu'à présent. Un autre anticancéreux, également éliminé par voie biliaire et susceptible d'atteindre l'environnement, est l'imatinib. Cette récente molécule a révolutionné le traitement et la survie des patients souffrant de leucémie myéloïde chronique et de tumeur stromales gastrointestinales. Les effets du tamoxifen et de l'imatinib sur plusieurs générations d'organismes aquatiques, tels que les microcrustacés Daphnia, sont inconnus et le 4OHTam et l'endoxifen n'ont même jamais été testés en écotoxicologie. Cette thèse s'est articulée autour de trois objectifs principaux. Premièrement, la sensibilité des D. pulex exposés au tamoxifen, 4OHTam, endoxifen et imatinib a été évaluée par l'intermédiaire de tests aigus et de tests sur deux à quatre générations. La mobilité, la taille, la reproduction, la viabilité et la croissance potentielle de la population ont été relevées au cours de ces expériences. Des tests supplémentaires, à but prospectifs, ont également été réalisés afin d'évaluer 1) la capacité de récupération des daphnies, lorsque leurs descendants ont été placés dans un milieu exempté de tamoxifen ou de 4OHTam, 2) les effets chez les daphnies exposées à une solution contenant de faibles concentration de tamoxifen et de 4OHTam mélangés. Le deuxième objectif a été d'évaluer la stabilité du tamoxifen, 4OHTam et endoxifen dilué dans le milieu des daphnies. Après analyses, les concentrations mesurées ne correspondaient pas aux concentrations nominales (c.-à-d., théoriques) et il a été nécessaire de développer une méthode efficace de prédiction des niveaux d'exposition lors de tests de longue durée réalisés avec ces trois molécules. Finalement, des changements dans l'expression des protéines chez des daphnies exposées au tamoxifen ont été investigués par l'intermédiaire d'expériences écotoxicoprotéomiques avec une approche dite de shot-gun avec une étape de fractionnement des protéines. Les résultats obtenus dans cette thèse montrent que le tamoxifen, le 4OHTam et l'endoxifen induisent des effets indésirables chez les daphnies à des niveaux d'exposition proches ou identiques aux concentrations du tamoxifen mesurées dans l'environnement, c'est-à-dire 0.12 et 0.67 µg/L de tamoxifen. Ces molécules ont induit des effets inhabituels tels que la production de : nouveau-nés anormaux, avec des antennes et des queues déformées, des prématurés et des oeufs avortés. Le tamoxifen fut la molécule la plus toxique pour les D. pulex suivie du 4OHTam, de l'endoxifen et enfin de l'imatinib. Lors des expériences sur plusieurs générations, les concentrations n'ayant statistiquement pas d'effet (c.à.d. NOEC en anglais) sur la taille, la reproduction et la croissance intrinsèque de la population étaient du même ordre de grandeur que les concentrations environnementales du tamoxifen. Par exemple, les NOECs du tamoxifen calculées pour la reproduction étaient de 0.67 et 0.72 µg/L, tandis que celle calculée sur la base des anomalies chez les nouveau-nés était < 0.15 µg/L. Les NOECs du 4OHTam se situaient entre 0.16 et 1.48 µg/L et celles de l'endoxifen pour la croissance intrinsèque de la population, ainsi que pour la reproduction, étaient de 0.4 et 4.3 µg/L, respectivement. Dans l'expérience basée sur la récupération des daphnies, la taille et la reproduction ont diminué bien que la descendance fût placée dans un milieu sans substances chimiques. Les daphnies exposées au mélange de tamoxifen et de 4OHTam ont produit moins de nouveau-nés que les contrôles, alors que ces concentrations n'ont pas induit d'effets lorsque testées individuellement. Finalement, l'imatinib n'a pas montré d'effets sur les deux générations testées. Seule la première génération exposée à la plus haute concentration (626 µg/L) a montré une diminution de la reproduction. Les résultats obtenus lors de l'évaluation de la stabilité du tamoxifen, 4OHTam et endoxifen dans le milieu des daphnies ont souligné l'importance d'utiliser des concentrations mesurées ou prédites en écotoxicologie. En effet, des différences notables entre concentrations nominales et mesurées ont été observées à toutes les concentrations et l'hypothèse d'un phénomène d'adsorption sur le verre des récipients a été posée. De ce fait, il a été nécessaire d'élaborer une méthode prédictive efficace et acceptable, en terme de temps et de coûts. Une régression polynomiale basée sur des concentrations mesurées et nominales a permis de prédire avec efficacité les faibles niveaux d'exposition utilisés lors d'expériences écotoxicologiques à long terme, sur plusieurs générations. Suite aux expériences d'écotoxicoprotéomiques, un total de 3940 protéines ont été identifiées et quantifiées chez des daphnies exposées au tamoxifen. Ce nombre est actuellement la plus large série de données publiées et mises à disposition pour la communauté scientifique. Parmi ces protéines, 189 sont significatives et possiblement reliées à des processus de reproduction et de stress. Sur cette base, nous avons émis l'hypothèse que les individus subissant un stress, lié à l'exposition au tamoxifen, ont utilisé leur énergie de base pour favoriser leur survie plutôt que la reproduction. Enfin, la détermination de bio-marqueurs exprimant des dommages précoces des daphnies exposées au tamoxifen n'a pas abouti en tant que telle, mais des protéines prometteuses, telle que la famille de viellogenin-2 (E9H8K5) et le récepteur à la ryanodine (E9FTU9), ont été exprimées après deux jours d'exposition déjà. Ces protéines pourraient faire l'objet d'investigations écotoxicoprotéomiques futures. Les résultats de cette thèse posent certaines questions quant au risque du tamoxifen, du 4OHTam et de l'endoxifen sur la faune et la flore aquatique et plus particulièrement sur les anticancéreux présents dans l'environnement. Les effets toxiques de ces molécules ont été observés à des concentrations environnementales et sur plusieurs générations. La question de considérer les métabolites, et ainsi les pro-médicaments, en écotoxicologie est soulevée, notamment parce que ces molécules peuvent être plus actives et efficaces que la molécule mère. Les expériences chroniques, sur plusieurs générations sont également à favoriser car elles offrent un meilleur reflet de la réalité environnementale que des essais aigus ou d'une génération. L'utilisation de la protéomique permet d'agrandir les connaissances sur les effets des médicaments à un niveau inférieur de l'organisation biologique et ainsi, de mieux comprendre de potentiels mécanismes d'action ou de déterminer de potentiels biomarqueurs. Finalement, il semble important de discuter de l'opportunité de mesurer les concentrations qui sont testées en écotoxicologie afin de ne pas sous-estimer le risque pour la faune et la flore aquatique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the study of the influence of optical aberrations in a joint-transform correlator: The wave aberration of the optical system is computed from data obtained by ray tracing. Three situations are explored: We consider the aberration only in the first diffraction stage (generation of power spectrum), then only in the second (transformation of the power spectrum into correlation), and finally in both stages simultaneously. The results show that the quality of the correlation is determined mostly by the aberrations of the first diffraction stage and that we can optimize the setup by moving the cameras along the optical axis to a suitable position. The good agreement between the predicted data and the experimental results shows that the method explains well the behavior of optical diffraction systems when aberrations are taken into account.