899 resultados para FEASIBILITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Manganese oxides in association with paleo-weathering may provide significant insights into the multiple factors affecting the formation and evolution of weathering profiles, such as temperature, precipitation, and biodiversity. Laser probe step-heating analysis of supergene hollandite and cryptomelane samples collected from central Queensland, Australia, yield well-defined plateaus and consistent isochron ages, confirming the feasibility, dating very-fined supergene manganese oxides by Ar-40/(39) Ar technique. Two distinct structural sites hosting Ar isotopes can be identified in light of their degassing behaviors obtained by incremental heating analyses. The first site, releasing its gas fraction at the laser power 0.2-0.4 W, yields primarily Ar-40(atm), Ar-38(atm), and Ar-36(atm), (atmospheric Ar isotopes). The second sites yield predominantly Ar-40* (radiogenic Ar-40), Ar-39(K), and Ar-38(K) (nucleogenic components), at similar to0.5-1.0 W. There is no significant Ar gas released at the laser power higher than 1.0 W, indicating the breakdown of the tunnel sites hosting the radiogenic and nucleogenic components. The excellent match between the degassing behaviors of Ar-40*, Ar-39(K), and Ar-38(K) suggests that these isotopes occupy the same crystallographic sites and that Ar-39(K) loss from the tunnel site by recoil during neutron irradiation and/or bake-out procedure preceding isotopic analysis does not occur. Present investigation supports that neither the overwhelming atmospheric Ar-40 nor the very-fined nature of the supergene manganese oxides poses problems in extracting meaningful weathering geo-chronological information by analyzing supergene manganese oxides minerals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. Evidence from animal studies, case reports, and phase I studies suggests that hemopoietic stem cell transplantation (HSCT) can be effective in the treatment of rheumatoid arthritis (RA). It is unclear, however, if depletion of T cells in the stem cell product infused after high-dose chemotherapy is beneficial in prolonging responses by reducing the number of infused autoreactive T cells. This pilot multicenter, randomized trial was undertaken to obtain feasibility data on whether CD34 selection (as a form of T cell depletion) of an autologous stem cell graft is of benefit in the HSCT procedure in patients with severe, refractory RA. Methods. Thirty-three patients with severe RA who had been treated unsuccessfully with methotrexate and at least 1 other disease-modifying agent were enrolled in the trial. The patients received high-dose immunosuppressive treatment with 200 mg/kg cyclophosphamide followed by an infusion of autologous stem cells that were CD34 selected or unmanipulated. Safety, efficacy (based on American College of Rheumatology [ACR] response criteria), and time to recurrence of disease were assessed on a monthly basis for up to 12 months. Results. All patients were living at the end of the study, with no major unexpected toxicities. Overall, on an intent-to-treat basis, ACR 20% response (ACR20) was achieved in 70% of the patients. An ACR70 response was attained in 27.7% of the 18 patients who had received CD34-selected cells and 53.3% of the 15 who had received unmanipulated cells (P = 0.20). The median time to disease recurrence was 147 days in the CD34-selected cell group and 201 days in the unmanipulated cell group (P = 0.28). There was no relationship between CD4 lymphopenia and response, but 72% of rheumatoid factor (RF)-positive patients had an increase in RF titer prior to recurrence of disease. Conclusion. HSCT can be performed safely in patients with RA, and initial results indicate significant responses in patients with severe, treatment-resistant disease. Similar outcomes were observed in patients undergoing HSCT with unmanipulated cells and those receiving CD34-selected cells. Larger studies are needed to confirm these findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge, especially scientific and technological knowledge, grows according to knowledge trajectories and guideposts that make up the prior knowledge of an organization. We argue that these knowledge structures and their specific components lead to successful innovation. A firm's prior knowledge facilitates the absorption of new knowledge, thereby renewing a firm's systematic search, transfer and acquisition of knowledge and capabilities. In particular, the exponential growth in biotechnology is characterized by the convergence of disparate scientific and technological knowledge resources. This paper examines the shift from protein-based to DNA-based diagnostic technologies as an example, to quantify the value of a firm's prior knowledge using relative values of knowledge distance. The distance between core prior knowledge and the rate of transition from one knowledge system to another has been identified as a proxy for the value a firm's prior knowledge. The overall difficulty of transition from one technology paradigm to another is discussed. We argue this transition is possible when the knowledge distance is minimal and the transition process has a correspondingly high value of absorptive capacities. Our findings show knowledge distance is a determinant of the feasibility, continuity and capture of scientific and technological knowledge. Copyright © 2003 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A more efficient classifying cyclone (CC) for fine particle classification has been developed in recent years at the JKMRC. The novel CC, known as the JKCC, has modified profiles of the cyclone body, vortex finder, and spigot when compared to conventional hydrocyclones. The novel design increases the centrifugal force inside the cyclone and mitigates the short circuiting flow that exists in all current cyclones. It also decreases the probability of particle contamination in the place near the cyclone spigot. Consequently the cyclone efficiency is improved while the unit maintains a simple structure. An international patent has been granted for this novel cyclone design. In the first development stage-a feasibility study-a 100 mm JKCC was tested and compared with two 100 min commercial units. Very encouraging results were achieved, indicating good potential for the novel design. In the second development stage-a scale-up stage-the JKCC was scaled up to 200 mm in diameter, and its geometry was optimized through numerous tests. The performance of the JKCC was compared with a 150 nun commercial unit and exhibited sharper separation, finer separation size, and lower flow ratios. The JKCC is now being scaled up into a fill-size (480 mm) hydrocyclone in the third development stage-an industrial study. The 480 mm diameter unit will be tested in an Australian coal preparation plant, and directly compared with a commercial CC operating under the same conditions. Classifying cyclone performance for fine coal could be further improved if the unit is installed in an inclined position. The study using the 200 mm JKCC has revealed that sharpness of separation improved and the flow ratio to underflow was decreased by 43% as the cyclone inclination was varied from the vertical position (0degrees) to the horizontal position (90degrees). The separation size was not affected, although the feed rate was slightly decreased. To ensure self-emptying upon shutdown, it is recommended that the JKCC be installed at an inclination of 75-80degrees. At this angle the cyclone performance is very similar to that at a horizontal position. Similar findings have been derived from the testing of a conventional hydrocyclone. This may be of benefit to operations that require improved performance from their classifying cyclones in terms of sharpness of separation and flow ratio, while tolerating slightly reduced feed rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the feasibility, safety and effectiveness of a structured clinical pathway for stratification and management of patients presenting with chest pain and classified as having intermediate risk of adverse cardiac outcomes in the subsequent six months. Design: Prospective clinical audit. Participants and setting: 630 consecutive patients who presented to the emergency department of a metropolitan tertiary care hospital between January 2000 and June 2001 with chest pain and intermediate-risk features. Intervention: Use of the Accelerated Chest Pain Assessment Protocol (ACPAP), as advocated by the Management of unstable angina guidelines - 2000 from the National Heart Foundation and the Cardiac Society of Australia and New Zealand. Main outcome measure: Adverse cardiac events during six-month follow-up. Results: 409 patients (65%) were reclassified as low risk and discharged at a mean of 14 hours after assessment in the chest pain unit. None had missed myocardial infarctions, while three (1%) had cardiac events at six months (all elective revascularisation procedures, with no readmissions with acute coronary syndromes). Another 110 patients (17%) were reclassified as high risk, and 21 (19%) of these had cardiac events (mainly revascularisations) by six months. Patients who were unable to exercise or had non-diagnostic exercise stress test results (equivocal risk) had an intermediate cardiac event rate (8%). Conclusions: This study validates use of ACPAP. The protocol eliminated missed myocardial infarction; allowed early, safe discharge of low-risk patients; and led to early identification and management of high-risk patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the strong influence of plant architecture on crop yield, most crop models either ignore it or deal with it in a very rudimentary way. This paper demonstrates the feasibility of linking a model that simulates the morphogenesis and resultant architecture of individual cotton plants with a crop model that simulates the effects of environmental factors on critical physiological processes and resulting yield in cotton. First the varietal parameters of the models were made concordant. Then routines were developed to allocate the flower buds produced each day by the crop model amongst the potential positions generated by the architectural model. This allocation is done according to a set of heuristic rules. The final weight of individual bolls and the shedding of buds and fruit caused by water, N, and C stresses are processed in a similar manner. Observations of the positions of harvestable fruits, both within and between plants, made under a variety of agronomic conditions that had resulted in a broad range of plant architectures were compared to those predicted by the model with the same environmental inputs. As illustrated by comparisons of plant maps, the linked models performed reasonably well, though performance of the fruiting point allocation and shedding algorithms could probably be improved by further analysis of the spatial relationships of retained fruit. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A administração desde seu início desenvolveu vários modelos de gestão a fim de obter eficiência. Treinar, capacitar e desenvolver o pessoal esteve na maioria desses modelos como algo imprescindível para se alcançar os resultados desejados. O governo que há vários anos busca um serviço público profissional e de qualidade publicou o decreto n. 5.707/2006 que regulamenta o desenvolvimento de pessoal da administração pública autárquica e fundacional. Neste decreto ele institui que o desenvolvimento de servidores deverá seguir o modelo de Gestão por Competências. Este trabalho trata de verificar a possibilidade da implantação desse novo modelo de gestão para confeccionar o programa de capacitação dos servidores técnicos administrativos em educação da Universidade Federal do Espírito Santo (UFES) elaborando uma proposta de projeto. Nesse sentido, faz-se uma revisão dos conceitos de treinamento, capacitação, desenvolvimento, competências e gestão por competências e através de seus constructos levanta-se a viabilidade de implantação de um programa de capacitação que inter-relacione as exigências do cargo com as habilidades e competências apresentadas ou não pelo servidor e o conteúdo dos treinamentos e cursos oferecidos pelo Departamento de Desenvolvimento de Pessoas da UFES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho apresenta um serviço de reconfiguração dinâmica para Redes de Sensores sem Fio. O trabalho inclui o projeto e a definição de uma arquitetura conceitual que suporta a coleta de uma variedade de informações contextuais e provê uma abstração alto nível para especificação de roteamento sensível ao contexto através de reconfiguração de métricas de roteamento e parâmetros de comunicação. O objetivo da infraestrutura proposta é possibilitar a criação de regras que adaptem o comportamento da rede em tempo de execução, em função dessas informações contextuais. Uma implementação da arquitetura para o protocolo RPL e o sistema operacional Contiki foi realizada, mostrando a viabilidade da abordagem proposta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os iogurtes simbióticos, que combinam microrganismos probióticos e substâncias prebióticas, adicionados de polpa de frutas são uma tendência crescente no mercado. O fruto açaí (Euterpe edulis) se destaca pela presença de compostos bioativos, como as antocianinas. Neste contexto, o presente trabalho teve como objetivo caracterizar e avaliar os parâmetros físico-químicos e a viabilidade microbiológica de iogurte simbiótico de açaí enriquecido com inulina e adicionado de cultura probiótica de Bifidobacterium animallis subsp. lactis BB-12. As formulações de iogurte atenderam aos requisitos físico-químicos exigidos pela IN no 46/2007 do MAPA apresentando teor de cinzas de 0,86 % ± 0,10, extrato seco total de 23,18 % ± 2,59, teor de gordura de 4,16 % ± 0,31, acidez de 0,70 % ± 0,05 e pH de 4,45 ± 0,10. Entre as formulações o conteúdo fenólico total variou de 18,17 a 117,84 mg de AGE/100 g, teor de antocianinas de 1,92 a 47,88 mg/100 g e atividade antioxidante de 0,71 a 6,95 μmol Trolox/g, observando-se um aumento de acordo com o aumento do teor de polpa de açaí adicionada. Ao final de 28 dias de armazenamento a 5 °C, observou-se uma redução no teor de antocianinas e da atividade antioxidante. Verificou-se a contribuição positiva da polpa de açaí na viabilidade das bactérias láticas totais, cujas contagens variaram de 4,56 a 7,04 log UFC.g-1 e de B. lactis BB-12 que variou de 3,17 a 6,34 log UFC.g-1, favorecendo a multiplicação dessas bactérias nos iogurtes. Nas formulações com 20 e 25 % de polpa de açaí as contagens das bactérias láticas totais e probiótica mantiveram-se viáveis de acordo com a IN no 46/2007 do MAPA e a Lista de Alegação de Propriedade Funcional (Anvisa), durante os 28 dias de armazenamento a 5 oC. Concluiu-se que a adição de polpa de açaí E. edulis, inulina e B. lactis BB-12 foi tecnologicamente viável na elaboração de iogurte simbiótico de açaí, sendo uma excelente alternativa de diversificação do produto no mercado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ambient Assisted Living (AAL) area is in constant evolution, providing new technologies to users and enhancing the level of security and comfort that is ensured by house platforms. The Ambient Assisted Living for All (AAL4ALL) project aims to develop a new AAL concept, supported on a unified ecosystem and certification process that enables a heterogeneous environment. The concepts of Intelligent Environments, Ambient Intelligence, and the foundations of the Ambient Assisted Living are all presented in the framework of this project. In this work, we consider a specific platform developed in the scope of AAL4ALL, called UserAccess. The architecture of the platform and its role within the overall AAL4ALL concept, the implementation of the platform, and the available interfaces are presented. In addition, its feasibility is validated through a series of tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, different techniques are available for manufacturing full-arch implant-supported prosthesis, many of them based on an impression procedure. Nevertheless, the long-term success of the prosthesis is highly influenced by the accuracy during such process, being affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of a 3D electromagnetic motion tracking system as an acquisition method for modeling such prosthesis. To this extent, we propose an implant acquisition method at the patient mouth, using a specific prototyped tool coupled with a tracker sensor, and a set of calibration procedures (for distortion correction and tool calibration), that ultimately obtains combined measurements of the implant’s position and angulation, and eliminating the use of any impression material. However, in the particular case of the evaluated tracking system, the order of magnitude of the obtained errors invalidates its use for this specific application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantitative analysis of cine cardiac magnetic resonance (CMR) images for the assessment of global left ventricular morphology and function remains a routine task in clinical cardiology practice. To date, this process requires user interaction and therefore prolongs the examination (i.e. cost) and introduces observer variability. In this study, we sought to validate the feasibility, accuracy, and time efficiency of a novel framework for automatic quantification of left ventricular global function in a clinical setting.