906 resultados para Experimental performance metrics
Resumo:
The shelter effect of a windbreak protects aggregate piles and provides a reduction of particle emissions in harbours. RANS (Reynolds-averaged Navier–Stokes equations) simulations using three variants of k–ε (standard k–ε, RNG k–ε and realizable k–ε) turbulence closure models have been performed to analyse wind flow characteristics behind an isolated fence located on a flat surface without roughness elements. The performance of the three turbulence models has been assessed by wind tunnel experiments. Cases of fences with different porosities (φ) have been evaluated using wind tunnel experiments as well as numerical simulations. The aim is to determine an optimum porosity for sheltering effect of an isolated windbreak. A value of 0.35 was found as the optimum value among the studied porosities (φ=0, 0.1, 0.24, 0.35, 0.4, 0.5).
Resumo:
Hoy en día, el proceso de un proyecto sostenible persigue realizar edificios de elevadas prestaciones que son, energéticamente eficientes, saludables y económicamente viables utilizando sabiamente recursos renovables para minimizar el impacto sobre el medio ambiente reduciendo, en lo posible, la demanda de energía, lo que se ha convertido, en la última década, en una prioridad. La Directiva 2002/91/CE "Eficiencia Energética de los Edificios" (y actualizaciones posteriores) ha establecido el marco regulatorio general para el cálculo de los requerimientos energéticos mínimos. Desde esa fecha, el objetivo de cumplir con las nuevas directivas y protocolos ha conducido las políticas energéticas de los distintos países en la misma dirección, centrándose en la necesidad de aumentar la eficiencia energética en los edificios, la adopción de medidas para reducir el consumo, y el fomento de la generación de energía a través de fuentes renovables. Los edificios de energía nula o casi nula (ZEB, Zero Energy Buildings ó NZEB, Net Zero Energy Buildings) deberán convertirse en un estándar de la construcción en Europa y con el fin de equilibrar el consumo de energía, además de reducirlo al mínimo, los edificios necesariamente deberán ser autoproductores de energía. Por esta razón, la envolvente del edifico y en particular las fachadas son importantes para el logro de estos objetivos y la tecnología fotovoltaica puede tener un papel preponderante en este reto. Para promover el uso de la tecnología fotovoltaica, diferentes programas de investigación internacionales fomentan y apoyan soluciones para favorecer la integración completa de éstos sistemas como elementos arquitectónicos y constructivos, los sistemas BIPV (Building Integrated Photovoltaic), sobre todo considerando el próximo futuro hacia edificios NZEB. Se ha constatado en este estudio que todavía hay una falta de información útil disponible sobre los sistemas BIPV, a pesar de que el mercado ofrece una interesante gama de soluciones, en algunos aspectos comparables a los sistemas tradicionales de construcción. Pero por el momento, la falta estandarización y de una regulación armonizada, además de la falta de información en las hojas de datos técnicos (todavía no comparables con las mismas que están disponibles para los materiales de construcción), hacen difícil evaluar adecuadamente la conveniencia y factibilidad de utilizar los componentes BIPV como parte integrante de la envolvente del edificio. Organizaciones internacionales están trabajando para establecer las normas adecuadas y procedimientos de prueba y ensayo para comprobar la seguridad, viabilidad y fiabilidad estos sistemas. Sin embargo, hoy en día, no hay reglas específicas para la evaluación y caracterización completa de un componente fotovoltaico de integración arquitectónica de acuerdo con el Reglamento Europeo de Productos de la Construcción, CPR 305/2011. Los productos BIPV, como elementos de construcción, deben cumplir con diferentes aspectos prácticos como resistencia mecánica y la estabilidad; integridad estructural; seguridad de utilización; protección contra el clima (lluvia, nieve, viento, granizo), el fuego y el ruido, aspectos que se han convertido en requisitos esenciales, en la perspectiva de obtener productos ambientalmente sostenibles, saludables, eficientes energéticamente y económicamente asequibles. Por lo tanto, el módulo / sistema BIPV se convierte en una parte multifuncional del edificio no sólo para ser física y técnicamente "integrado", además de ser una oportunidad innovadora del diseño. Las normas IEC, de uso común en Europa para certificar módulos fotovoltaicos -IEC 61215 e IEC 61646 cualificación de diseño y homologación del tipo para módulos fotovoltaicos de uso terrestre, respectivamente para módulos fotovoltaicos de silicio cristalino y de lámina delgada- atestan únicamente la potencia del módulo fotovoltaico y dan fe de su fiabilidad por un período de tiempo definido, certificando una disminución de potencia dentro de unos límites. Existe también un estándar, en parte en desarrollo, el IEC 61853 (“Ensayos de rendimiento de módulos fotovoltaicos y evaluación energética") cuyo objetivo es la búsqueda de procedimientos y metodologías de prueba apropiados para calcular el rendimiento energético de los módulos fotovoltaicos en diferentes condiciones climáticas. Sin embargo, no existen ensayos normalizados en las condiciones específicas de la instalación (p. ej. sistemas BIPV de fachada). Eso significa que es imposible conocer las efectivas prestaciones de estos sistemas y las condiciones ambientales que se generan en el interior del edificio. La potencia nominal de pico Wp, de un módulo fotovoltaico identifica la máxima potencia eléctrica que éste puede generar bajo condiciones estándares de medida (STC: irradición 1000 W/m2, 25 °C de temperatura del módulo y distribución espectral, AM 1,5) caracterizando eléctricamente el módulo PV en condiciones específicas con el fin de poder comparar los diferentes módulos y tecnologías. El vatio pico (Wp por su abreviatura en inglés) es la medida de la potencia nominal del módulo PV y no es suficiente para evaluar el comportamiento y producción del panel en términos de vatios hora en las diferentes condiciones de operación, y tampoco permite predecir con convicción la eficiencia y el comportamiento energético de un determinado módulo en condiciones ambientales y de instalación reales. Un adecuado elemento de integración arquitectónica de fachada, por ejemplo, debería tener en cuenta propiedades térmicas y de aislamiento, factores como la transparencia para permitir ganancias solares o un buen control solar si es necesario, aspectos vinculados y dependientes en gran medida de las condiciones climáticas y del nivel de confort requerido en el edificio, lo que implica una necesidad de adaptación a cada contexto específico para obtener el mejor resultado. Sin embargo, la influencia en condiciones reales de operación de las diferentes soluciones fotovoltaicas de integración, en el consumo de energía del edificio no es fácil de evaluar. Los aspectos térmicos del interior del ambiente o de iluminación, al utilizar módulos BIPV semitransparentes por ejemplo, son aún desconocidos. Como se dijo antes, la utilización de componentes de integración arquitectónica fotovoltaicos y el uso de energía renovable ya es un hecho para producir energía limpia, pero también sería importante conocer su posible contribución para mejorar el confort y la salud de los ocupantes del edificio. Aspectos como el confort, la protección o transmisión de luz natural, el aislamiento térmico, el consumo energético o la generación de energía son aspectos que suelen considerarse independientemente, mientras que todos juntos contribuyen, sin embargo, al balance energético global del edificio. Además, la necesidad de dar prioridad a una orientación determinada del edificio, para alcanzar el mayor beneficio de la producción de energía eléctrica o térmica, en el caso de sistemas activos y pasivos, respectivamente, podría hacer estos últimos incompatibles, pero no necesariamente. Se necesita un enfoque holístico que permita arquitectos e ingenieros implementar sistemas tecnológicos que trabajen en sinergia. Se ha planteado por ello un nuevo concepto: "C-BIPV, elemento fotovoltaico consciente integrado", esto significa necesariamente conocer los efectos positivos o negativos (en términos de confort y de energía) en condiciones reales de funcionamiento e instalación. Propósito de la tesis, método y resultados Los sistemas fotovoltaicos integrados en fachada son a menudo soluciones de vidrio fácilmente integrables, ya que por lo general están hechos a medida. Estos componentes BIPV semitransparentes, integrados en el cerramiento proporcionan iluminación natural y también sombra, lo que evita el sobrecalentamiento en los momentos de excesivo calor, aunque como componente estático, asimismo evitan las posibles contribuciones pasivas de ganancias solares en los meses fríos. Además, la temperatura del módulo varía considerablemente en ciertas circunstancias influenciada por la tecnología fotovoltaica instalada, la radiación solar, el sistema de montaje, la tipología de instalación, falta de ventilación, etc. Este factor, puede suponer un aumento adicional de la carga térmica en el edificio, altamente variable y difícil de cuantificar. Se necesitan, en relación con esto, más conocimientos sobre el confort ambiental interior en los edificios que utilizan tecnologías fotovoltaicas integradas, para abrir de ese modo, una nueva perspectiva de la investigación. Con este fin, se ha diseñado, proyectado y construido una instalación de pruebas al aire libre, el BIPV Env-lab "BIPV Test Laboratory", para la caracterización integral de los diferentes módulos semitransparentes BIPV. Se han definido también el método y el protocolo de ensayos de caracterización en el contexto de un edificio y en condiciones climáticas y de funcionamiento reales. Esto ha sido posible una vez evaluado el estado de la técnica y la investigación, los aspectos que influyen en la integración arquitectónica y los diferentes tipos de integración, después de haber examinado los métodos de ensayo para los componentes de construcción y fotovoltaicos, en condiciones de operación utilizadas hasta ahora. El laboratorio de pruebas experimentales, que consiste en dos habitaciones idénticas a escala real, 1:1, ha sido equipado con sensores y todos los sistemas de monitorización gracias a los cuales es posible obtener datos fiables para evaluar las prestaciones térmicas, de iluminación y el rendimiento eléctrico de los módulos fotovoltaicos. Este laboratorio permite el estudio de tres diferentes aspectos que influencian el confort y consumo de energía del edificio: el confort térmico, lumínico, y el rendimiento energético global (demanda/producción de energía) de los módulos BIPV. Conociendo el balance de energía para cada tecnología solar fotovoltaica experimentada, es posible determinar cuál funciona mejor en cada caso específico. Se ha propuesto una metodología teórica para la evaluación de estos parámetros, definidos en esta tesis como índices o indicadores que consideran cuestiones relacionados con el bienestar, la energía y el rendimiento energético global de los componentes BIPV. Esta metodología considera y tiene en cuenta las normas reglamentarias y estándares existentes para cada aspecto, relacionándolos entre sí. Diferentes módulos BIPV de doble vidrio aislante, semitransparentes, representativos de diferentes tecnologías fotovoltaicas (tecnología de silicio monocristalino, m-Si; de capa fina en silicio amorfo unión simple, a-Si y de capa fina en diseleniuro de cobre e indio, CIS) fueron seleccionados para llevar a cabo una serie de pruebas experimentales al objeto de demostrar la validez del método de caracterización propuesto. Como resultado final, se ha desarrollado y generado el Diagrama Caracterización Integral DCI, un sistema gráfico y visual para representar los resultados y gestionar la información, una herramienta operativa útil para la toma de decisiones con respecto a las instalaciones fotovoltaicas. Este diagrama muestra todos los conceptos y parámetros estudiados en relación con los demás y ofrece visualmente toda la información cualitativa y cuantitativa sobre la eficiencia energética de los componentes BIPV, por caracterizarlos de manera integral. ABSTRACT A sustainable design process today is intended to produce high-performance buildings that are energy-efficient, healthy and economically feasible, by wisely using renewable resources to minimize the impact on the environment and to reduce, as much as possible, the energy demand. In the last decade, the reduction of energy needs in buildings has become a top priority. The Directive 2002/91/EC “Energy Performance of Buildings” (and its subsequent updates) established a general regulatory framework’s methodology for calculation of minimum energy requirements. Since then, the aim of fulfilling new directives and protocols has led the energy policies in several countries in a similar direction that is, focusing on the need of increasing energy efficiency in buildings, taking measures to reduce energy consumption, and fostering the use of renewable sources. Zero Energy Buildings or Net Zero Energy Buildings will become a standard in the European building industry and in order to balance energy consumption, buildings, in addition to reduce the end-use consumption should necessarily become selfenergy producers. For this reason, the façade system plays an important role for achieving these energy and environmental goals and Photovoltaic can play a leading role in this challenge. To promote the use of photovoltaic technology in buildings, international research programs encourage and support solutions, which favors the complete integration of photovoltaic devices as an architectural element, the so-called BIPV (Building Integrated Photovoltaic), furthermore facing to next future towards net-zero energy buildings. Therefore, the BIPV module/system becomes a multifunctional building layer, not only physically and functionally “integrated” in the building, but also used as an innovative chance for the building envelope design. It has been found in this study that there is still a lack of useful information about BIPV for architects and designers even though the market is providing more and more interesting solutions, sometimes comparable to the existing traditional building systems. However at the moment, the lack of an harmonized regulation and standardization besides to the non-accuracy in the technical BIPV datasheets (not yet comparable with the same ones available for building materials), makes difficult for a designer to properly evaluate the fesibility of this BIPV components when used as a technological system of the building skin. International organizations are working to establish the most suitable standards and test procedures to check the safety, feasibility and reliability of BIPV systems. Anyway, nowadays, there are no specific rules for a complete characterization and evaluation of a BIPV component according to the European Construction Product Regulation, CPR 305/2011. BIPV products, as building components, must comply with different practical aspects such as mechanical resistance and stability; structural integrity; safety in use; protection against weather (rain, snow, wind, hail); fire and noise: aspects that have become essential requirements in the perspective of more and more environmentally sustainable, healthy, energy efficient and economically affordable products. IEC standards, commonly used in Europe to certify PV modules (IEC 61215 and IEC 61646 respectively crystalline and thin-film ‘Terrestrial PV Modules-Design Qualification and Type Approval’), attest the feasibility and reliability of PV modules for a defined period of time with a limited power decrease. There is also a standard (IEC 61853, ‘Performance Testing and Energy Rating of Terrestrial PV Modules’) still under preparation, whose aim is finding appropriate test procedures and methodologies to calculate the energy yield of PV modules under different climate conditions. Furthermore, the lack of tests in specific conditions of installation (e.g. façade BIPV devices) means that it is difficult knowing the exact effective performance of these systems and the environmental conditions in which the building will operate. The nominal PV power at Standard Test Conditions, STC (1.000 W/m2, 25 °C temperature and AM 1.5) is usually measured in indoor laboratories, and it characterizes the PV module at specific conditions in order to be able to compare different modules and technologies on a first step. The “Watt-peak” is not enough to evaluate the panel performance in terms of Watt-hours of various modules under different operating conditions, and it gives no assurance of being able to predict the energy performance of a certain module at given environmental conditions. A proper BIPV element for façade should take into account thermal and insulation properties, factors as transparency to allow solar gains if possible or a good solar control if necessary, aspects that are linked and high dependent on climate conditions and on the level of comfort to be reached. However, the influence of different façade integrated photovoltaic solutions on the building energy consumption is not easy to assess under real operating conditions. Thermal aspects, indoor temperatures or luminance level that can be expected using building integrated PV (BIPV) modules are not well known. As said before, integrated photovoltaic BIPV components and the use of renewable energy is already a standard for green energy production, but would also be important to know the possible contribution to improve the comfort and health of building occupants. Comfort, light transmission or protection, thermal insulation or thermal/electricity power production are aspects that are usually considered alone, while all together contribute to the building global energy balance. Besides, the need to prioritize a particular building envelope orientation to harvest the most benefit from the electrical or thermal energy production, in the case of active and passive systems respectively might be not compatible, but also not necessary. A holistic approach is needed to enable architects and engineers implementing technological systems working in synergy. A new concept have been suggested: “C-BIPV, conscious integrated BIPV”. BIPV systems have to be “consciously integrated” which means that it is essential to know the positive and negative effects in terms of comfort and energy under real operating conditions. Purpose of the work, method and results The façade-integrated photovoltaic systems are often glass solutions easily integrable, as they usually are custommade. These BIPV semi-transparent components integrated as a window element provides natural lighting and shade that prevents overheating at times of excessive heat, but as static component, likewise avoid the possible solar gains contributions in the cold months. In addition, the temperature of the module varies considerably in certain circumstances influenced by the PV technology installed, solar radiation, mounting system, lack of ventilation, etc. This factor may result in additional heat input in the building highly variable and difficult to quantify. In addition, further insights into the indoor environmental comfort in buildings using integrated photovoltaic technologies are needed to open up thereby, a new research perspective. This research aims to study their behaviour through a series of experiments in order to define the real influence on comfort aspects and on global energy building consumption, as well as, electrical and thermal characteristics of these devices. The final objective was to analyze a whole set of issues that influence the global energy consumption/production in a building using BIPV modules by quantifying the global energy balance and the BIPV system real performances. Other qualitative issues to be studied were comfort aspect (thermal and lighting aspects) and the electrical behaviour of different BIPV technologies for vertical integration, aspects that influence both energy consumption and electricity production. Thus, it will be possible to obtain a comprehensive global characterization of BIPV systems. A specific design of an outdoor test facility, the BIPV Env-lab “BIPV Test Laboratory”, for the integral characterization of different BIPV semi-transparent modules was developed and built. The method and test protocol for the BIPV characterization was also defined in a real building context and weather conditions. This has been possible once assessed the state of the art and research, the aspects that influence the architectural integration and the different possibilities and types of integration for PV and after having examined the test methods for building and photovoltaic components, under operation conditions heretofore used. The test laboratory that consists in two equivalent test rooms (1:1) has a monitoring system in which reliable data of thermal, daylighting and electrical performances can be obtained for the evaluation of PV modules. The experimental set-up facility (testing room) allows studying three different aspects that affect building energy consumption and comfort issues: the thermal indoor comfort, the lighting comfort and the energy performance of BIPV modules tested under real environmental conditions. Knowing the energy balance for each experimented solar technology, it is possible to determine which one performs best. A theoretical methodology has been proposed for evaluating these parameters, as defined in this thesis as indices or indicators, which regard comfort issues, energy and the overall performance of BIPV components. This methodology considers the existing regulatory standards for each aspect, relating them to one another. A set of insulated glass BIPV modules see-through and light-through, representative of different PV technologies (mono-crystalline silicon technology, mc-Si, amorphous silicon thin film single junction, a-Si and copper indium selenide thin film technology CIS) were selected for a series of experimental tests in order to demonstrate the validity of the proposed characterization method. As result, it has been developed and generated the ICD Integral Characterization Diagram, a graphic and visual system to represent the results and manage information, a useful operational tool for decision-making regarding to photovoltaic installations. This diagram shows all concepts and parameters studied in relation to each other and visually provides access to all the results obtained during the experimental phase to make available all the qualitative and quantitative information on the energy performance of the BIPV components by characterizing them in a comprehensive way.
Resumo:
The main objetive of this Doctoral Thesis was to study the influence of female castration and pig sex on growth performance and carcass and meat quality of white pigs slaughtered at different final weights. Three experiments (Exp.) were conducted. In Exp. 1, a total of 200 (Landrace * Large White dam x Pietrain * Large White sire) gilts of 50 ± 3 days of age (23.3 ± 1.47 kg BW) was used to investigate the effects of castration (intact females, IF vs. castrated feamles, CF) and slaughter weight (106 vs. 122 kg BW) on productive performance and carcass and meat quality. There were four experimental treatments arranged as a 2 x 2 factorial and 5 replicates of 10 pigs each per treatment. Half of the gilts were ovariectomized at 58 d of age (8 days after the beginning of the trial; 29.8 ± 1.64 kg BW) whereas the other half remained intact. Meat samples were taken at m. Longissimus thoracis at the level of the last rib and subcutaneous fat samples were taken at the tail insertion. For the entire experiment period, CF had higher BW gain (P<0.05) and backfat and m. Gluteus medius (GM) fat thickness (P<0.001) than IF. However, IF had higher loin and trimmed primal cut yields (P<0.05) than CF. Meat quality was similar for IF and CF but the proportion of linoleic acid in subcutaneous fat was higher (P<0.001) for IF. Pigs slaughtered at 122 kg BW had higher (P<0.001) feed intake and poorer feed efficiency than pigs slaughtered at 106 kg BW. An increase in slaughter weight (SW) improved (P<0.001) carcass yield but decreased (P<0.05) trimmed primal cut yield. Meat from females slaughtered at the heavier BW was redder (a*; P<0.001) and had more (P<0.01) intramuscular fat and less thawing (P<0.05) and cooking (P<0.10) loss than meat from females slaughtered at the lighter BW. Also, females slaughtered at 122 kg BW had less (P<0.01) linoleic acid content in the subcutaneous fat than pigs slaughtered at 106 kg BW. Castration of gilts and slaughtering at heavier BW might be useful practices for the production of heavy pigs destined to the dry cured industry in which a certain amount of fat in the carcass is required. In contrast, when the carcasses are destined to fresh meat production, IF slaughtered at 106 kg BW are a more efficient alternative. In Exp. 2, crossbred pigs (n=240) from Pietrain*Large White sires mated to Landrace*Large White dams with an average of 100 d of age (60.5 ± 2.3 kg) were used to investigate the effects of gender and slaughter weight (SW) on growth performance and carcass and meat quality characteristics. There were 6 treatments arranged factorially with 3 genders (IF vs. CF vs.castrated males, CM) and 2 SW (114 vs. 122 kg BW). Each of the 6 combinations of treatments was replicated 4 times and the experimental unit was a pen with 10 pigs. Castrated males and CF ate more feed, grew faster and had more carcass backfat depth and fat thickness at the GM muscle, but lower loin yield than IF (P<0.05). In addition, CF and CM had more intramuscular fat (P<0.05) and less linoleic acid content in the subcutaneous fat (P<0.01) than IF. Pigs slaughtered at 122 kg BW had lower ADG (P<0.05), poor gain-to-feed ratio (P<0.05), and more GM fat than pigs slaughtered at 114 kg BW (P < 0.05). It is concluded that CF and CM had similar productive performance and meat quality characteristics when slaughtered at the same age, and that the castration of females improved daily gains and increased weight and fat content of primal cuts with respect to IF. Therefore, castration of females is recommended in pigs destined to the dry-cured industry because of the beneficial effects on the quality of the primal cuts. In Exp. 3, the effects of gender and castration of females (IF vs. CF vs. CM) on performance and carcass and meat quality were studied in crossbred pigs (Landrace x Large White dams x Duroc sires) slaughtered at 119.2 (trial 1) or 131.6 (trial 2) kg BW. Intact females had better feed conversion and less carcass fat than CF and CM. Trimmed shoulder yield was higher for CM than for CF with IF being intermediate. Primal cut yield and meat quality, however were similar for all treatments. Proportion of linoleic acid in backfat was lower for CF than for IF or CM, and the differences were significant in pigs slaughtered witn 131.6 kg BW. The higher fat content and the fatty acid profile favour the use of CF and CM over IF for the production of heavy pigs destined to the dry-cured industry.
Resumo:
El atrio incorporado en los edificios ha sido un recurso espacial que tempranamente se difundió a nivel global, siendo adoptado por las distintas arquitecturas locales en gran parte del mundo. Su masificación estuvo favorecida primero por la rápida evolución de la tecnología del acero y el vidrio, a partir del siglo XIX, y en segundo termino por el posterior desarrollo del hormigón armado. Otro aspecto que explica tal aceptación en la arquitectura contemporánea, es de orden social y radica en la llamativa cavidad del espacio describiendo grandes dimensiones y favoreciendo con ello, el desarrollo de una multiplicidad de usos en su interior que antes eran impensados. Al interior del atrio, la luz natural es clave en las múltiples vivencias que alberga y sea tal vez la condición ambiental más valorada, ya que entrega una sensación de bienestar al conectarnos visualmente con el ambiente natural. Por esta razón de acuerdo al método hipotético deductivo, se evaluaron los efectos de la configuración geométrica, la cubierta y la orientación en el desempeño de la iluminación natural en la planta baja, a partir un modelo extraído desde el inventario de los edificios atrio construidos en Santiago de Chile, en los últimos 30 años que fue desarrollado en el capitulo 2. El análisis cuantitativo de los edificios inventariados se elaboró en el capítulo 3, considerando las dimensiones de los atrios. Simultáneamente fueron clasificados los aspectos constructivos, los materiales y las características del ambiente interior de cada edificio. En esta etapa además, fueron identificadas las variables de estudio de las proporciones geométricas de la cavidad del atrio con los coeficientes de aspecto de las proporciones, en planta (PAR), en corte (SAR) y de la cavidad según (WI), (AR) y (RI). Del análisis de todos estos parámetros se extrajo el modelo de prueba. El enfoque del estudio del capítulo 4 fue la iluminación natural, se revisaron los conceptos y el comportamiento en el atrio, a partir de un modelo físico construido a escala para registro de la iluminancia bajo cielo soleado de la ciudad. Más adelante se construyó el modelo en ambiente virtual, relacionando las variables determinadas por la geometría de la cavidad y el cerramiento superior; examinándose de esta manera distintas transparencias, proporciones de apertura, en definitiva se evaluó un progresivo cerramiento de las aberturas, verificando el ingreso de la luz y disponibilidad a nivel de piso con la finalidad, de proveer lineamientos útiles en una primera etapa del diseño arquitectónico. Para el análisis de la iluminación natural se revisaron diferentes métodos de cálculo con el propósito de evaluar los niveles de iluminancia en un plano horizontal al interior del atrio. El primero de ellos fue el Factor de Luz Día (FLD) que corresponde, a la proporción de la iluminancia en un punto de evaluación interior respecto, la cantidad proveniente del exterior bajo cielo nublado, a partir de la cual se obtuvo resultados que revelaron la alta luminosidad del cielo nublado de la ciudad. Además fueron evaluadas las recientes métricas dinámicas que dan cuenta, de la cantidad de horas en las cuales de acuerdo a los extensos registros meteorológico de la ciudad, permitieron obtener el porcentajes de horas dentro de las cuales se cumplió el estándar de iluminancia requerido, llamado autonomía lumínica (DA) o mejor aún se permanece dentro de un rango de comodidad visual en el interior del atrio referido a la iluminancia diurna útil (UDI). En el Capítulo 5 se exponen los criterios aplicados al modelo de estudio y cada una de las variantes de análisis, además se profundizó en los antecedentes y procedencia de las fuentes de los registros climáticos utilizados en las simulaciones llevadas a cabo en el programa Daysim operado por Radiance. Que permitieron evaluar el desempeño lumínico y la precisión, de cada uno de los resultados para comprobar la disponibilidad de iluminación natural a través de una matriz. En una etapa posterior se discutieron los resultados, mediante la comparación de los datos logrados según cada una de las metodologías de simulación aplicada. Finalmente se expusieron las conclusiones y futuras lineas de trabajo, las primeras respecto el dominio del atrio de cuatro caras, la incidencia del control de cerramiento de la cubierta y la relación establecida con la altura; indicando en lo específico que las mediciones de iluminancia bajo el cielo soleado de verano, permitieron aclarar, el uso de la herramienta de simulación y método basado en el clima local, que debido a su reciente desarrollo, orienta a futuras líneas de trabajo profundizando en la evaluación dinámica de la iluminancia contrastado con monitorización de casos. ABSTRACT Atriums incorporated into buildings have been a spatial resource that quickly spread throughout the globe, being adopted by several local architecture methods in several places. Their widespread increase was highly favored, in the first place, with the rapid evolution of steel and glass technologies since the nineteen century, and, in second place, by the following development of reinforced concrete. Another issue that explains this success into contemporary architecture is associated with the social approach, and it resides in the impressive cavity that describes vast dimensions, allowing the development of multiple uses in its interior that had never been considered before. Inside the atrium, daylight it is a key element in the many experiences that involves and it is possibly the most relevant environmental factor, since it radiates a feeling of well-being by uniting us visually with the natural environment. It is because of this reason that, following the hypothetical deductive method, the effects in the performance of daylight on the floor plan were evaluated considering the geometric configuration, the deck and orientation factors. This study was based in a model withdrawn from the inventory of atrium buildings that were constructed in Santiago de Chile during the past thirty years, which will be explained later in chapter 2. The quantitative analysis of the inventory of those buildings was elaborated in chapter 3, considering the dimensions of the atriums. Simultaneously, several features such as construction aspects, materials and environmental qualities were identified inside of each building. At this stage, it were identified the variables of the geometric proportions of the atrium’s cavity with the plan aspect ratio of proportions in first plan (PAR), in section (SAR) and cavity according to well index (WI), aspect ratio (AR) and room index (RI). An experimental model was obtained from the analysis of all the mentioned parameters. The main focus of the study developed in chapter 4 is daylight. The atrium’s concept and behavior were analyzed from a physical model built under scale to register the illuminances under clear, sunny sky of the city. Later on, this physical model was built in a virtual environment, connecting the variables determined by the geometry of the cavity and the superior enclosure, allowing the examination of transparencies and opening proportions. To summarize, this stage consisted on evaluating a progressive enclosure of the openings, checking the access of natural light and its availability at the atrium floor, in an effort to provide useful guidelines during the first stage of the architectural design. For the analysis of natural lighting, several calculations methods were used in order to determine the levels of illuminances in a horizontal plane inside of the atrium. The first of these methods is the Daylight Factor (DF), which consists in the proportion of light in an evaluation interior place with the amount of light coming from the outside in a cloudy day. Results determined that the cloudy sky of the city has high levels of luminosity. In addition, the recent dynamic metrics were evaluated which reflects the hours quantity. According to the meteorological records of the city’s climate, the standard of illuminance- a standard measure called Daylight Autonomy (DA) – was met. This is even better when the results stay in the line of visual convenience within the atrium, which is referred to as Useful Daylight Illuminance (UDI). In chapter 5, it was presented the criteria applied to the study model and on each of the variants of the analysis. Moreover, the information of the climate records used for the simulations - carried out in the Daysim program managed by Radiance – are detailed. These simulations allowed the observation of the daylight performance and the accuracy of each of the results to confirm the availability of natural light through a matrix. In a later stage, the results were discussed comparing the collected data in each of the methods of simulation used. Finally, conclusions and further discussion are presented. Overall, the four side atrium’s domain and the effect of the control of the cover’s enclosure. Specifically, the measurements of the daylight under summer’s clear, sunny sky allowing clarifying the use of the simulation tool and the method based on the local climate. This method allows defining new and future lines of work deepening on the dynamic of the light in contrast with the monitoring of the cases.
Resumo:
Esta investigación aborda el estudio de la influencia de las uniones en el aislamiento acústico a ruido aéreo en los edificios y el análisis de las transmisiones indirectas producidas en particiones de dos hojas de ladrillo cerámico sobre bandas elásticas. La transmisión de ruido entre dos recintos separados por una partición se produce por dos vías: La vía directa a través del elemento que separa los dos recintos y la vía indirecta, a través de los elementos de flanco, como forjados, particiones, fachadas, etc. que conectados a dicho elemento de separación, vibran en presencia del campo acústico transmitiendo sus vibraciones al recinto receptor. Si las transmisiones indirectas son dominantes, el aislamiento acústico “in situ” puede ser menor que el esperado. El parámetro que expresa la atenuación acústica en las uniones es el índice de reducción vibracional en la unión o Kij. Éste parámetro se utiliza en los métodos de cálculo del aislamiento acústico a ruido aéreo, que permiten la justificación del cumplimiento de la normativa actual, el Documento Básico DB HR Protección frente al ruido del CTE. La determinación de los índices Kij de las uniones es una cuestión que debe abordarse de forma experimental. Existen diferentes expresiones empíricas obtenidas en varios laboratorios europeos que permiten el cálculo del índice Kij, pero no se han validado con ensayos realizados en soluciones habituales en la construcción española, como las estudiadas en este trabajo. El objetivo de este trabajo es la medida, análisis y cuantificación de las transmisiones indirectas producidas en las uniones de elementos de dos hojas de fábrica de ladrillo cerámico. Se ha recurrido a una campaña de ensayos en la que se reproducían las condiciones de un edificio real y se ha medido el aislamiento acústico a ruido aéreo y los índices Kij de diferentes configuraciones de uniones. Del análisis de los resultados, se demuestra que el aislamiento acústico a ruido aéreo depende de las uniones, pudiéndose obtener mejoras significativas al variar la forma de unión entre los elementos constructivos. Las mejoras de aislamiento acústico están relacionadas con un buen diseño de las uniones y con valores elevados del índice Kij. Este trabajo aporta valores experimentales de Kij para soluciones de fábrica de ladrillo y pone en discusión los valores teóricos que actualmente aparecen en la normativa vigente. ABSTRACT This research work deals with the effects of junction construction details on airborne sound insulation in buildings and the analysis of flanking transmissions across double ceramic brick walls with elastic interlayers. The sound transmission between two adjacent rooms comprises two paths: the direct path, caused by the incident sound on a separating wall, and the indirect path, through flanking elements connected to the separating wall, such as floors, internal walls, ceilings, etc. Flanking elements vibrate when excited in the sound field, thus transferring sound via structure borne to the receiving room. Dominant flanking transmissions can decrease the field sound insulation performance of the building. The vibration reduction index, Kij. expresses the acoustic attenuation of construction joints. This is an input parameter in the calculation models designed to estimate the airborne sound insulation between adjoining rooms in buildings. These models are used to comply with the acoustic requirements set by Basic Document DB HR Protection against noise included in the Spanish Building Code. The characterization of Kij. must be addressed experimentally by means of measurements. The available empirical Kij. formulae were developed in different European laboratories, but they have not been validated with standard tests performed on common Spanish walls, such as those studied in this work. The aim of this work is the measurement, analysis and quantification of indirect transmissions though joints of double ceramic brick walls. Airborne sound insulation tests and Kij measurements were performed in a laboratory which emulated the conditions of a real building. These tests were performed in different partitions whose joints were modified. It follows from the analysis of the results that airborne sound insulation depends strongly on the design of joints. Sound insulation improves when the joints between construction elements are modified to eliminate acoustic bridges. The increase in sound insulation corresponds to best practice design of joints and to high Kij values. This research work provides experimental Kij data of double ceramic brick walls and the results put in discussion the theoretical values set in the current Standards.
Resumo:
El propósito de esta tesis es estudiar la aproximación a los fenómenos de transporte térmico en edificación acristalada a través de sus réplicas a escala. La tarea central de esta tesis es, por lo tanto, la comparación del comportamiento térmico de modelos a escala con el correspondiente comportamiento térmico del prototipo a escala real. Los datos principales de comparación entre modelo y prototipo serán las temperaturas. En el primer capítulo del Estado del Arte de esta tesis se hará un recorrido histórico por los usos de los modelos a escala desde la antigüedad hasta nuestro días. Dentro de éste, en el Estado de la Técnica, se expondrán los beneficios que tiene su empleo y las dificultades que conllevan. A continuación, en el Estado de la Investigación de los modelos a escala, se analizarán artículos científicos y tesis. Precisamente, nos centraremos en aquellos modelos a escala que son funcionales. Los modelos a escala funcionales son modelos a escala que replican, además, una o algunas de las funciones de sus prototipos. Los modelos a escala pueden estar distorsionados o no. Los modelos a escala distorsionados son aquellos con cambios intencionados en las dimensiones o en las características constructivas para la obtención de una respuesta específica por ejemplo, replicar el comportamiento térmico. Los modelos a escala sin distorsión, o no distorsionados, son aquellos que mantienen, en la medida de lo posible, las proporciones dimensionales y características constructivas de sus prototipos de referencia. Estos modelos a escala funcionales y no distorsionados son especialmente útiles para los arquitectos ya que permiten a la vez ser empleados como elementos funcionales de análisis y como elementos de toma de decisiones en el diseño constructivo. A pesar de su versatilidad, en general, se observará que se han utilizado muy poco estos modelos a escala funcionales sin distorsión para el estudio del comportamiento térmico de la edificación. Posteriormente, se expondrán las teorías para el análisis de los datos térmicos recogidos de los modelos a escala y su aplicabilidad a los correspondientes prototipos a escala real. Se explicarán los experimentos llevados a cabo, tanto en laboratorio como a intemperie. Se han realizado experimentos con modelos sencillos cúbicos a diferentes escalas y sometidos a las mismas condiciones ambientales. De estos modelos sencillos hemos dado el salto a un modelo reducido de una edificación acristalada relativamente sencilla. Los experimentos consisten en ensayos simultáneos a intemperie del prototipo a escala real y su modelo reducido del Taller de Prototipos de la Escuela Técnica Superior de Arquitectura de Madrid (ETSAM). Para el análisis de los datos experimentales hemos aplicado las teorías conocidas, tanto comparaciones directas como el empleo del análisis dimensional. Finalmente, las simulaciones nos permiten comparaciones flexibles con los datos experimentales, por ese motivo, hemos utilizado tanto programas comerciales como un algoritmo de simulación desarrollado ad hoc para esta investigación. Finalmente, exponemos la discusión y las conclusiones de esta investigación. Abstract The purpose of this thesis is to study the approximation to phenomena of heat transfer in glazed buildings through their scale replicas. The central task of this thesis is, therefore, the comparison of the thermal performance of scale models without distortion with the corresponding thermal performance of their full-scale prototypes. Indoor air temperatures of the scale model and the corresponding prototype are the data to be compared. In the first chapter on the State of the Art, it will be shown a broad vision, consisting of a historic review of uses of scale models, from antiquity to our days. In the section State of the Technique, the benefits and difficulties associated with their implementation are presented. Additionally, in the section State of the Research, current scientific papers and theses on scale models are reviewed. Specifically, we focus on functional scale models. Functional scale models are scale models that replicate, additionally, one or some of the functions of their corresponding prototypes. Scale models can be distorted or not. Scale models with distortion are considered scale models with intentional changes, on one hand, in dimensions scaled unevenly and, on the other hand, in constructive characteristics or materials, in order to get a specific performance for instance, a specific thermal performance. Consequently, scale models without distortion, or undistorted scale models scaled evenly, are those replicating, to the extent possible, without distortion, the dimensional proportions and constructive configurations of their prototypes of reference. These undistorted and functional scale models are especially useful for architects because they can be used, simultaneously, as functional elements of analysis and as decision-making elements during the design. Although they are versatile, in general, it is remarkable that these types of models are used very little for the study of the thermal performance of buildings. Subsequently, the theories related to the analysis of the experimental thermal data collected from the scale models and their applicability to the corresponding full-scale prototypes, will be explained. Thereafter, the experiments in laboratory and at outdoor conditions are detailed. Firstly, experiments carried out with simple cube models at different scales are explained. The prototype larger in size and the corresponding undistorted scale model have been subjected to same environmental conditions in every experimental test. Secondly, a step forward is taken carrying out some simultaneous experimental tests of an undistorted scale model, replica of a relatively simple lightweight and glazed building construction. This experiment consists of monitoring the undistorted scale model of the prototype workshop located in the School of Architecture (ETSAM) of the Technical University of Madrid (UPM). For the analysis of experimental data, known related theories and resources are applied, such as, direct comparisons, statistical analyses, Dimensional Analysis and last, but not least important, simulations. Simulations allow us, specifically, flexible comparisons with experimental data. Here, apart the use of the simulation software EnergyPlus, a simulation algorithm is developed ad hoc for this research. Finally, the discussion and conclusions of this research are exposed.
Resumo:
Multijunction solar cells (MJSC) use anti-reflective coatings (ARC) to minimize Fresnel reflection losses for a family of light incidence angles. These coatings adapt the refractive index of the cell to that of the surrounding medium. Patterns with sizes in the range of the light wavelength can be used to further reduce reflections through diffraction. Transparent nanopatterns with a gradual profile, called moth-eye nanostructures, can adapt the refractive index of the optical interfaces (often with n∼1.5) used to encapsulate concentrator solar cells to that of the air (n air∼1). Here we show the effect of a nanometric moth-eye ARC with a round motif deposited on commercial MJSC that achieves short-circuit current (I SC) gains greater than 2% at normal incidence and even higher in the case of tilted illumination. In this work, MJSC with different moth-eye ARC are characterized under quantum efficiency (QE) as well as under concentrated illumination I-V in order to assess their potential. Simulations based on coupled wave analysis (RCWA) are used to fit the experimental results with successful results.
Resumo:
The addition of oxygenated renewable fuels, such as ethanol or ethyl tert-butyl ether (ETBE) to standard gasoline may be necessary to comply with some environmental directives but could also prevent compliance with some fuel regulations and could also seriously change engine performance. From this point of view, the Reid Vapour Pressure (RVP), the distillation curve, the oxygen content and the density belong to the group of the most relevant parameters. This study evaluates the influence of the simultaneous addition of ethanol and ETBE on some physical properties of engine gasoline. The main conclusion is that the simultaneous addition of ETBE and ethanol changes the RVP, the distillation curve and the density in a way that can affect engine operation and the mandatory EN 228 and ASTM D4814 standards. Some opposite properties of both oxygenates could help to increase the renewable energy content without preventing compliance with these regulations.
Resumo:
The biological bases of learning and memory are being revealed today with a wide array of molecular approaches, most of which entail the analysis of dysfunction produced by gene disruptions. This perspective derives both from early “genetic dissections” of learning in mutant Drosophila by Seymour Benzer and colleagues and from earlier behavior-genetic analyses of learning and in Diptera by Jerry Hirsch and coworkers. Three quantitative-genetic insights derived from these latter studies serve as guiding principles for the former. First, interacting polygenes underlie complex traits. Consequently, learning/memory defects associated with single-gene mutants can be quantified accurately only in equilibrated, heterogeneous genetic backgrounds. Second, complex behavioral responses will be composed of genetically distinct functional components. Thus, genetic dissection of complex traits into specific biobehavioral properties is likely. Finally, disruptions of genes involved with learning/memory are likely to have pleiotropic effects. As a result, task-relevant sensorimotor responses required for normal learning must be assessed carefully to interpret performance in learning/memory experiments. In addition, more specific conclusions will be obtained from reverse-genetic experiments, in which gene disruptions are restricted in time and/or space.
Resumo:
O presente trabalho teve por foco prover uma revisão de conceitos relacionados às resinas dentais fotopolimeráveis e, também, analisar como diferentes concentrações de fotoiniciadores de uso comum em odontologia podem influenciar no desempenho mecânico e na cor de resinas dentais. Concentrações de 0,01%, 0,10%, 0,25% 0,50%, 0,75%, 1,00% e 10% em massa de fotoiniciador foram adicionadas em uma matriz polimérica composta por TEGDMA/BisGMA 50%/50% em massa de forma que, fixando variáveis externas referentes à fonte de luz e à preparação das amostras, foi possível avaliar o efeito da concentração de fotoiniciador nas propriedades mecânicas de resistência à fratura por compressão, resistência à fratura pela aplicação de tensão diametral e dureza Barcol. Por fim, o efeito da concentração na cor aferida através do método CIELab foi investigada. Os fotoiniciadores utilizados foram o Irgacure® 819, a 1-fenil-1,2-propanodiona (PPD) e a Canforoquinona a qual foi utilizada juntamente com ocoiniciador Etil-4 dimetilaminobenzoato (EDB) na concentração constante de 1% em massa. Os resultados mecânicos e de cor foram comparados entre as diferentes amostras através de análises estatísticas (ANOVA) e, especificamente para cor, o parâmetro de diferença de cor (ΔE) foi interpretado verificar se as alterações observadas são perceptíveis ao olho humano. Para fundamentar os estudos, análises do espectro de absorção das amostras, do espectro de irradiação da fonte de luz e do grau de conversão das amostras foram realizadas. Os resultados revelaram que, independentemente do fotoiniciador, graus de conversão da mesma ordem de grandeza de um adesivo comercial foram obtidos, porém as velocidades de reação foram diferentes (maior velocidade para as amostras de CQ e menor para PPD). Curvas características foram obtidas para os espectros de absorção e de irradiação confirmando, pela sobreposição das curvas, que a fonte de luz é efetiva para iniciação da polimerização das amostras. As análises de resistência à fratura revelaram que a quebra catastrófica do material ocorrerá preferencialmente quando a força é aplicada ao longo do diâmetro para os corpos de prova preparados. Quanto à dureza, verificou-se que que para a CQ houve um máximo, para Irgacure um comportamento assintótico com aumento da concentração e, para a PPD, não foi possível a obtenção de amostras (verificado que a PPD necessita de tempo de irradiação superior ao convencionalmente utilizado na prática odontológica). Os testes de ANOVA permitiram verificar que o Irgacure é capaz de fornecer resultados mecânicos semelhante em relação à CQ ocasionando, em contrapartida, um menor escurecimento e amarelamento. Analisando o parâmetro ΔE, confirmou-se que a alteração na cor se torna evidente à medida que ocorre o aumento da concentração de fotoiniciador independentemente do fotoiniciador utilizado, porém a alteração é maior para a CQ.
Resumo:
Os contêineres metálicos foram desenvolvidos para a utilização no setor de logística e transporte, mas por sua escala adaptável à das edificações e pela mobilidade e praticidade de instalação, tiveram sua utilização apropriada também pelo setor da construção civil. Essas instalações possuem diversas qualidades ambientalmente amigáveis, mas seu aspecto térmico é extremamente insuficiente: sem isolamento térmico, demandam alta carga térmica de refrigeração e aquecimento, no verão e inverno, respectivamente e, consequentemente, um alto consumo energético. Tal característica foi crucial para que se determinassem como objetivos da presente pesquisa investigar o comportamento térmico dessas construções metálicas, avaliar seus parâmetros de desempenho, conforto e estresse térmicos, por meio de uma ampla coleta de dados experimentais. O experimento com duração de um ano - contou com três tipologias de contêiner em escala real, sendo o primeiro em aço Tipo X sem isolamento térmico, o segundo com um isolamento térmico para o fenômeno da condução e o terceiro com isolamento térmico para o fenômeno da radiação. Os diferentes tipos de tratamentos térmicos proporcionaram melhorias à envoltória dos contêineres, chegando a uma diferença nas temperaturas internas de até 9 °C. Constatou-se a extrema necessidade de adequação do tipo de isolamento térmico dos contêineres ao uso a que tais instalações se destinam escritório ou alojamento, no caso dos canteiros de obras para que as características da envoltória minimizem de fato a demanda ou mesmo atinjam a eliminação da necessidade de condicionamento artificial.
Resumo:
ALICE is one of four major experiments of particle accelerator LHC installed in the European laboratory CERN. The management committee of the LHC accelerator has just approved a program update for this experiment. Among the upgrades planned for the coming years of the ALICE experiment is to improve the resolution and tracking efficiency maintaining the excellent particles identification ability, and to increase the read-out event rate to 100 KHz. In order to achieve this, it is necessary to update the Time Projection Chamber detector (TPC) and Muon tracking (MCH) detector modifying the read-out electronics, which is not suitable for this migration. To overcome this limitation the design, fabrication and experimental test of new ASIC named SAMPA has been proposed . This ASIC will support both positive and negative polarities, with 32 channels per chip and continuous data readout with smaller power consumption than the previous versions. This work aims to design, fabrication and experimental test of a readout front-end in 130nm CMOS technology with configurable polarity (positive/negative), peaking time and sensitivity. The new SAMPA ASIC can be used in both chambers (TPC and MCH). The proposed front-end is composed of a Charge Sensitive Amplifier (CSA) and a Semi-Gaussian shaper. In order to obtain an ASIC integrating 32 channels per chip, the design of the proposed front-end requires small area and low power consumption, but at the same time requires low noise. In this sense, a new Noise and PSRR (Power Supply Rejection Ratio) improvement technique for the CSA design without power and area impact is proposed in this work. The analysis and equations of the proposed circuit are presented which were verified by electrical simulations and experimental test of a produced chip with 5 channels of the designed front-end. The measured equivalent noise charge was <550e for 30mV/fC of sensitivity at a input capacitance of 18.5pF. The total core area of the front-end was 2300?m × 150?m, and the measured total power consumption was 9.1mW per channel.
Resumo:
A avaliação do risco a contaminação e a escolha de técnicas de remediação de poluentes em aquíferos fraturados depende da quantificação dos fenômenos envolvidos no transporte de solutos. A geometria da fratura, usualmente caracterizada pela abertura, é o principal parâmetro que indiretamente controla o transporte nos aquíferos fraturados. A simplificação mais comum desse problema é assumir que as fraturas são um par de placas planas e paralelas, isto é, com uma abertura constante. No entanto, por causa do limitado número de trabalhos experimentais, não está esclarecida a adequabilidade do uso de uma abertura constante para simular o transporte conservativo em fraturas do Aquífero Serra Geral (ASG), Brasil. O objetivo deste trabalho é avaliar a influência da abertura de uma fratura natural do Aquífero Serra Geral sob o transporte conservativo de solutos. Uma amostra natural de basalto fraturado foi usada em um experimento hidráulico e de transporte de um traçador conservativo (escala de laboratório). O campo de abertura foi medido usando a técnica avançada, de alta resolução e tridimensional, chamada microtomografia computadorizada de raios-X. A concentração de traçador medida foi utilizada para validar uma solução analítica unidimensional da Equação de Advecção-dispersão (ADE). O desemprenho do ajuste da ADE às curvas de passagem experimentais foi avaliado para quatro diferentes tipos de aberturas constantes. Os resultados mostraram que o escoamento de água e o transporte de contaminantes pode ocorrer através de fraturas micrométricas, ocasionando, eventualmente, a contaminação do ASG. A abertura de balanço de massa é a única que pode ser chamada propriamente de \"abertura equivalente\". O uso de aberturas constantes na ADE não permitiu representar completamente o formato das curvas de passagem porque o campo de velocidade não é uniforme e intrinsicamente bidimensional. Portanto, na simulação do transporte deve-se incorporar a heterogeneidade da abertura da fratura.
Resumo:
Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
Resumo:
Different types of crystalline carbon nanomaterials were used to reinforce polyaniline for use in electromechanical bilayer bending actuators. The objective is to analyze how the different graphitic structures of the nanocarbons affect and improve the in situ polymerized polyaniline composites and their subsequent actuator behavior. The nanocarbons investigated were multiwalled carbon nanotubes, nitrogen-doped carbon nanotubes, helical-ribbon carbon nanofibers and graphene oxide, each one presenting different shape and structural characteristics. Films of nanocarbon-PAni composite were tested in a liquid electrolyte cell system. Experimental design was used to select the type of nanocarbon filler and composite loadings, and yielded a good balance of electromechanical properties. Raman spectroscopy suggests good interaction between PAni and the nanocarbon fillers. Electron microscopy showed that graphene oxide dispersed the best, followed by multiwall carbon nanotubes, while nitrogen-doped nanotube composites showed dispersion problems and thus poor performance. Multiwall carbon nanotube composite actuators showed the best performance based on the combination of bending angle, bending velocity and maximum working cycles, while graphene oxide attained similarly good performance due to its best dispersion. This parallel testing of a broad set of nanocarbon fillers on PAni-composite actuators is unprecedented to the best of our knowledge and shows that the type and properties of the carbon nanomaterial are critical to the performance of electromechanical devices with other conditions remaining equal.