998 resultados para Experimental anxiety
Resumo:
A potentially renewable and sustainable source of energy is the chemical energy associated with solvation of salts. Mixing of two aqueous streams with different saline concentrations is spontaneous and releases energy. The global theoretically obtainable power from salinity gradient energy due to World’s rivers discharge into the oceans has been estimated to be within the range of 1.4-2.6 TW. Reverse electrodialysis (RED) is one of the emerging, membrane-based, technologies for harvesting the salinity gradient energy. A common RED stack is composed by alternately-arranged cation- and anion-exchange membranes, stacked between two electrodes. The compartments between the membranes are alternately fed with concentrated (e.g., sea water) and dilute (e.g., river water) saline solutions. Migration of the respective counter-ions through the membranes leads to ionic current between the electrodes, where an appropriate redox pair converts the chemical salinity gradient energy into electrical energy. Given the importance of the need for new sources of energy for power generation, the present study aims at better understanding and solving current challenges, associated with the RED stack design, fluid dynamics, ionic mass transfer and long-term RED stack performance with natural saline solutions as feedwaters. Chronopotentiometry was used to determinate diffusion boundary layer (DBL) thickness from diffusion relaxation data and the flow entrance effects on mass transfer were found to avail a power generation increase in RED stacks. Increasing the linear flow velocity also leads to a decrease of DBL thickness but on the cost of a higher pressure drop. Pressure drop inside RED stacks was successfully simulated by the developed mathematical model, in which contribution of several pressure drops, that until now have not been considered, was included. The effect of each pressure drop on the RED stack performance was identified and rationalized and guidelines for planning and/or optimization of RED stacks were derived. The design of new profiled membranes, with a chevron corrugation structure, was proposed using computational fluid dynamics (CFD) modeling. The performance of the suggested corrugation geometry was compared with the already existing ones, as well as with the use of conductive and non-conductive spacers. According to the estimations, use of chevron structures grants the highest net power density values, at the best compromise between the mass transfer coefficient and the pressure drop values. Finally, long-term experiments with natural waters were performed, during which fouling was experienced. For the first time, 2D fluorescence spectroscopy was used to monitor RED stack performance, with a dedicated focus on following fouling on ion-exchange membrane surfaces. To extract relevant information from fluorescence spectra, parallel factor analysis (PARAFAC) was performed. Moreover, the information obtained was then used to predict net power density, stack electric resistance and pressure drop by multivariate statistical models based on projection to latent structures (PLS) modeling. The use in such models of 2D fluorescence data, containing hidden, but extractable by PARAFAC, information about fouling on membrane surfaces, considerably improved the models fitting to the experimental data.
Resumo:
INTRODUCTION: Amphotericin B, azole or sulfamide drugs are used for treatment of patients with paracoccidioidomycosis. Among the azole drugs, voriconazole was active in vitro against Paracoccidioides brasiliensis and showed efficacy in the treatment of patients infected with this fungus.In the present study the antifungal activity of voriconazole and of other drugs was compared in a rat model of paracoccidioidomycosis. METHODS: Wistar rats were inoculated intravenously with the BOAS strain of P. brasiliensis and antifungal drugs were administered to the animals by gavage at the following doses (mg/kg weight/day): voriconazole (5 to 20), ketoconazole (12 to 15), fluconazole (6), itraconazole (4), and sulfamethoxazole-trimethoprim (120 to 150). The antifungal activity of the drugs was assessed by determining the P. brasiliensis colony forming units in the lungs and spleen of the animals at the end of treatment and by a survival study. RESULTS: Voriconazole reduced the total tissue fungal burden of P. brasiliensis, particularly at doses of ≥10mg/kg weight/day but its antifungal activity was less intense than that of fluconazole, itraconazole and sulfamethoxazole-trimethoprim. The mean survival of animals treated with the last three drugs, 29.1±10.7, 26.1± 10.1 and 28.4±9.6 days, respectively, was higher than that achieved with voriconazole 10mg/kg weight/day (18.5±8.3 days) and that observed in untreated animals (15.7±3.6 days). CONCLUSIONS: At doses similar to those used for clinical treatment, voriconazole showed lower antifungal activity in experimental rat paracoccidioidomycosis than that obtained with itraconazole and sulfamethoxazole-trimethoprim.
Resumo:
Earthen plastering mortars are becoming recognized as highly eco-efficient. The assessment of their technical properties needs to be standardized but only the German standard DIN 18947 exists for the moment. An extended experimental campaign was developed in order to assess multiple properties of a ready-mixed earth plastering mortar and also to increase scientific knowledge of the influence of test procedures on those properties. The experimental campaign showed that some aspects related to the equipment, type of samples and sample preparation can be very important, while others seemed to have less influence on the results and the classification of mortars. It also showed that some complementary tests can easily be performed and considered together with the standardized ones, while others may need to be improved. The plaster satisfied the requirements of the existing German standard but, most importantly, it seemed adequate for application as rehabilitation plaster on historic and modern masonry buildings. Apart from their aesthetic aspect, the contribution of earthen plasters to eco-efficiency and particularly to hygrometric indoor comfort should be highlighted.
Resumo:
O presente estudo experimental pretende avaliar o comportamento da aderência entre varões em aço nervurado e o betão, a influência da geometria, do estado de fendilhação do betão e da presença de um varão transversal na zona de ancoragem, no comportamento desta. O bom desempenho das estruturas de betão armado depende da sua ligação e aderência entre os diferentes materiais utilizados na sua conceção, aço e betão. Foi com esse pressuposto que a presente dissertação avançou, de forma a serem estudadas as diversas geometrias e condições a que podem estar sujeitas as ancoragens. Para isso, foram elaborados e ensaiados dezasseis modelo de ancoragem: seis modelos em betão fendilhado e dez modelos em betão não fendilhado. Do estudo experimental desenvolvido, os resultados obtidos em betão não fendilhado dos ensaios de arrancamento “Pull-Out” são comparados com as recomendações NP EN 1992-1-1 [27], fib Model Code 2010 [14] e o Structural Concrete Building Code ACI 318-11 [4]. No presente estudo experimental também foi analisado o efeito da fendilhação do betão, permitindo assim compreender melhor o funcionamento e a resistência de uma ancoragem sujeita a essa situação. O efeito da presença de um varão transversal aplicado na zona do mandril foi também estudado.
Resumo:
Introduction This study assessed the viability of the rabies virus in the argasid tick Carios fonsecai following experimental infection. Methods The mouse inoculation test (MIT), fluorescent antibody test (FAT) and polymerase chain reaction (PCR) were used. The rabies virus was administered to ticks via the intra-coelomic route, and the ticks were sacrificed at different time points. Results The inoculated ticks were negative for rabies according to the MIT. Ticks macerated with rabies virus were positive according to the MIT and FAT. All of the tick lots tested by PCR were positive. Conclusions The rabies virus became unviable shortly after its inoculation into tick bodies. Ticks are not likely to play an important role in the epidemiology of rabies.
Resumo:
A União Europeia tem dado cada vez mais enfoque à eficiência energética nos edifícios e à sua capacidade de produção de energia, tendo lançado a directiva “Energy Performance of Buildings Directive” com o intuito de que até 31 de Dezembro de 2018 todos os edifícios novos sejam “nZEB-nearly Zero Energy Building”, o que significa que devem por um lado diminuir o seu consumo energético, aumentando a sua eficiência, e por outro lado produzir localmente e através de fontes de energias renováveis toda, ou quase toda, a energia de que necessitam. A presente tese está integrada no Projecto “Frame – Prefabricated systems (modules) for low-energy buildings: design, prototyping and testing” (Ref: PTDC/AURAQI-AQI/117782/2010) que está a ser desenvolvido na Unidade de Eficiência Energética do Laboratório Nacional de Energia e Geologia (LNEG). Neste trabalho é desenvolvido e analisado um sistema BIPV/T-PCM (Building Integrated Photovoltaic Thermal – Phase Change Materials) que engloba todo um novo conceito de captação, armazenamento e gestão da energia solar em fachadas. Este sistema é composto por um módulo fotovoltaico, uma bateria de PCM (Materiais de Mudança de Fase) e todo um sistema de fluxo de ar que permite a gestão da energia colectada e armazenada. Foi também desenvolvido teoricamente um código de gestão energética para a manipulação do sistema. O sistema em estudo apoia-se em três objectivos principais: aquecer no inverno; arrefecer no verão; e aumentar a eficiência do PV arrefecendo-o. Na sequência do trabalho realizado verificou-se que o conceito do sistema em estudo alcança alguns dos objectivos propostos, tendo ainda potencial para se continuar o seu desenvolvimento. O sistema em estudo é um sistema inovador, e como tal está a ser registada uma patente com base no conceito desenvolvido.
Resumo:
Introduction Hematophagous Desmodus rotundus bats play an important role in the rabies lifecycle. This study describes the hematological profile of these bats before and after experimental infection with rabies virus. Methods Cells counts were performed in a Neubauer chamber. Results The average values of erythrocytes and leucocytes counts in blood before experimental infections were 9.97 × 106mm3 and 4.80 × 103mm3, respectively. Neutrophils represented 69.9% of white blood cells and the lymphocytes represented 26.9%. Following the experimental infections, the average numbers of erythrocytes and leucocytes was 9.43 × 106mm3 and 3.98 × 103mm3, respectively. Neutrophils represented 40% of white blood cells and the lymphocytes represented 59%. Conclusions The hematological profile given in this study can serve as reference values for D. rotundus bats.
Resumo:
With the projection of an increasing world population, hand-in-hand with a journey towards a bigger number of developed countries, further demand on basic chemical building blocks, as ethylene and propylene, has to be properly addressed in the next decades. The methanol-to-olefins (MTO) is an interesting reaction to produce those alkenes using coal, gas or alternative sources, like biomass, through syngas as a source for the production of methanol. This technology has been widely applied since 1985 and most of the processes are making use of zeolites as catalysts, particularly ZSM-5. Although its selectivity is not especially biased over light olefins, it resists to a quick deactivation by coke deposition, making it quite attractive when it comes to industrial environments; nevertheless, this is a highly exothermic reaction, which is hard to control and to anticipate problems, such as temperature runaways or hot-spots, inside the catalytic bed. The main focus of this project is to study those temperature effects, by addressing both experimental, where the catalytic performance and the temperature profiles are studied, and modelling fronts, which consists in a five step strategy to predict the weight fractions and activity. The mind-set of catalytic testing is present in all the developed assays. It was verified that the selectivity towards light olefins increases with temperature, although this also leads to a much faster catalyst deactivation. To oppose this effect, experiments were carried using a diluted bed, having been able to increase the catalyst lifetime between 32% and 47%. Additionally, experiments with three thermocouples placed inside the catalytic bed were performed, analysing the deactivation wave and the peaks of temperature throughout the bed. Regeneration was done between consecutive runs and it was concluded that this action can be a powerful means to increase the catalyst lifetime, maintaining a constant selectivity towards light olefins, by losing acid strength in a steam stabilised zeolitic structure. On the other hand, developments on the other approach lead to the construction of a raw basic model, able to predict weight fractions, that should be tuned to be a tool for deactivation and temperature profiles prediction.
Resumo:
INTRODUCTION: Rotavirus is the main etiologic agent of acute infectious diarrhea in children worldwide. Considering that a rotavirus vaccine (G1P8, strain RIX4414) was added to the Brazilian vaccination schedule in 2006, we aimed to study its effectiveness and safety regarding intestinal intussusception. METHODS: A quasi-experimental trial was performed in which the primary outcome was the number of hospitalizations that were presumably due to acute infectious diarrhea per 100,000 children at risk (0-4 years old). The secondary outcomes included mortality due to acute infectious diarrhea and the intestinal intussusception rates in children in the same age range. We analyzed three scenarios: Health Division XIII of the State of São Paulo (DRS XIII) from 2002 to 2008, the State of São Paulo, and Brazil from 2002 to 2012. RESULTS: The averages of the hospitalization rates for 100,000 children in the pre- and post-vaccination periods were 1,413 and 959, respectively, for DRS XIII (RR=0.67), 312 and 249, respectively, for the State of São Paulo (RR=0.79), and 718 and 576, respectively, for Brazil (RR=0.8). The mortality rate per 100,000 children in the pre- and post-vaccination periods was 2.0 and 1.3, respectively, for DRS XIII (RR=0.66), 5.5 and 2.5, respectively, for the State of São Paulo (RR=0.47), and 15.0 and 8.0, respectively, for Brazil (RR=0.53). The average annual rates of intussusception for 100,000 children in DRS XIII were 28.0 and 22.0 (RR=0.77) in the pre- and post-vaccination periods, respectively. CONCLUSIONS: A monovalent rotavirus vaccine was demonstrated to be effective in preventing the hospitalizations and deaths of children that were presumably due to acute infectious diarrhea, without increasing the risk of intestinal intussusception.
Resumo:
RESUMO - Estudos anteriores nos Cuidados de Saúde Primários (CSP) apontam para um incremento da Deteção Precoce (DP) e Intervenções Breves (IB) em pacientes com Problemas Ligados ao Álcool (PLA) após formação apropriada dos profissionais de saúde (com melhoria das suas atitudes). Este estudo quasi experimental, exploratório, é pioneiro no âmbito da Saúde Ocupacional (SO) para a implementação de Rastreio/DP e IB nos PLA. O objetivo principal foi avaliar se uma formação sobre Rastreio/DP e IB pode melhorar as atitudes dos profissionais de SO ao lidar com os PLA em Meio Laboral (PLAML). Foi aplicado um questionário em duas partes: Q1/pré-formação (variáveis sociodemográficas, profissionais, competências em alcoologia, experiência pessoal com álcool/familiares com PLA, dificuldades em lidar com trabalhadores com PLA, AUDIT-C e SAAPPQ) e Q2/pós-formação (avaliação da formação e das atitudes SAAPPQ - Adequação, Legitimidade, Motivação, Autoestima e Satisfação). Os resultados na amostra (N=39) revelaram um aumento sobretudo na Adequação e Satisfação. No entanto, naqueles com níveis baixos das atitudes pré-formação constou-se melhoria das atitudes à excepção da Autoestima e foram encontradas algumas associações com as características do perfil inicial dos participantes. Sugerem-se estudos posteriores para identificação de pacotes formativos mais efetivos e propostas para um Plano integrador de RIB para PLAML
Resumo:
A quantidade de edifícios em degradação em Portugal que necessita de reabilitação é bastante elevada. As alvenarias antigas e históricas por vezes apresentam um estado avançado de degradação por ineficiente concepção ou por falta de manutenção. Desta forma as alvenarias necessitam de acções de reforço e consolidação com o intuito de fortalecer as suas resistências a diversos tipos de carregamentos. A presente dissertação está relacionada com uma técnica de consolidação das mais utilizadas e actuais, a injecção de grouts em alvenarias. O reforço por injecção de grouts é bastante utilizado em alvenarias de pano múltiplo, onde permite uma maior coesão entre materiais, uniformidade de tensões e continuidade de panos. Os principais objectivos de consolidação de uma alvenaria através da técnica de injecção de grouts são: a ocupação de espaços vazios de forma a aumentar a sua rigidez e a sua resistência; e o restabelecimento das ligações entre panos que ao longo do tempo deixou de existir, ou seja, um comportamento monolítico quando aplicado um carregamento vertical ou horizontal como um sismo. Daí a importância da análise de resistência ao corte numa da alvenaria de pano múltiplo. O presente trabalho teve uma componente laboratorial muito extensa, onde se efectuou injecções em modelos paralelipipédicos simulando o núcleo interior de uma parede de alvenaria antiga. O grout constituído por cal hidraúlica, superplastificante e água foi injectado no molde com um dos meios porosos de um dos dois materiais, calcário ou cerâmico. Após a cura cortaram-se em fatias os provetes e analisou-se a velocidade de propagação de ultra-sons com dois tipos de trandutores (cilíndricos e cónicos). Os ensaios mecânicos utilizados foram o diagonal test e o ensaio de corte directo de modo a determinar a resistência ao corte e finalmente comparou-se os valores dos ensaios para determinação das propriedades. Ainda com o intuito de avaliar as ligações grout-partícula do meio poroso foram avaliadas algumas fotografias tiradas a partir da lupa binocular. A técnica de injecção de grouts demonstrou-se uma técnica muito interessante e eficiente na análise de corte, no entanto esta técnica apresenta melhores resultados quando é utilizada em consonância com outras técnicas.
Resumo:
For esophageal reconstruction in newborns with esophageal atresia, esophageal reunion with an end-to-end anastomosis is the ideal procedure, although it may result in leaks and strictures due to tension on the suture line, mainly in cases with a wide gap between the ends. Circular myotomy (Livaditis' procedure) is the best method to elongate the proximal esophageal pouch and reduce anastomotic tension. This experimental investigation in dogs was undertaken to attempt to verify that circular myotomy decreases the anastomotic leak rate in newborns with wide gap esophageal atresia, and to analyze whether the technique promotes morphologic changes in the anastomotic scar. A pilot study demonstrated that it is necessary to resect more than 8 cm (40% of the total esophageal length) in order to obtain high leak rates. In the experimental project, such resection was performed in dogs divided into two groups (control group, anastomosis only, and experimental group, anastomosis plus circular myotomy in the proximal esophageal segment). The animals were killed in the 14th postoperative day, submitted to autopsy, and were evaluated as to the presence of leaks and strictures, as well as to the features (macroscopic and microscopic aspects) of the anastomosis. Leak rates were the same in both groups. Morphometric analysis revealed that in animals in the experimental group, the anastomotic scar was thinner than the control animals, and the isolated muscular manchette distal to the site of myotomy was replaced by fibrous tissue. Correspondingly, a decreased number of newly formed small vessels were noted in the experimental animals, compared to control animals. We concluded that circular myotomy does not decrease the incidence of anastomotic leaks, and it also promotes deleterious changes in anastomotic healing.
Resumo:
Mega-organs, primarily in the digestive tract, are well known to occur in chronic Chagas disease. Acute experimental infection with Trypanosoma cruzi results in parasitism of a wide range of cells, tissues, and organs, including the urinary bladder. Infection of BALB/c mice with 100,000 bloodstream forms of the Y strain of T. cruzi induced acute infection with intense parasitism of all layers of the urinary bladder. Parasites were found in the mucosa, lamina propria, muscular, adventitial connective, and fat tissue. Desquamate epithelial cells with amastigotes in the bladder lumen were also found. After 60 days of infection, mice inoculated with 50 bloodstream forms developed dilated, thin-walled bladders that had inflammatory infiltrates and foci of fibrosis replacing areas of damaged muscular layer. These lesions result from direct damage to the muscle fibers by the T. cruzi, leading to myosites, muscle damage, and scarring. Direct damage of paraganglia cells secondary to parasitism, leading to dilatation, damage of muscle fibers, and scarring with replacement of muscular tissue with connective tissue, should also be considered as a cause of functional disturbance of the urinary bladder.