931 resultados para Error estimator
Bit-error rate performance of 20 Gbit/s WDM RZ-DPSK non-slope matched submarine transmission systems
Resumo:
Applying direct error counting, we assess the performance of 20 Gbit/s wavelength-division multiplexing return-to-zero differential phase-shift keying (RZ-DPSK) transmission at 0.4 bit/(s Hz) spectral efficiency for application on installed non-zero dispersion-shifted fibre based transoceanic submarine systems. The impact of the pulse duty cycle on the system performance is investigated and the reliability of the existing theoretical approaches to the BER estimation for the RZ-DPSK format is discussed.
Resumo:
In efficiency studies using the stochastic frontier approach, the main focus is to explain inefficiency in terms of some exogenous variables and computation of marginal effects of each of these determinants. Although inefficiency is estimated by its mean conditional on the composed error term (the Jondrow et al., 1982 estimator), the marginal effects are computed from the unconditional mean of inefficiency (Wang, 2002). In this paper we derive the marginal effects based on the Jondrow et al. estimator and use the bootstrap method to compute confidence intervals of the marginal effects.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Factors associated with duration of dementia in a consecutive series of 103 Alzheimer's disease (AD) cases were studied using the Kaplan-Meier estimator and Cox regression analysis (proportional hazard model). Mean disease duration was 7.1 years (range: 6 weeks-30 years, standard deviation = 5.18); 25% of cases died within four years, 50% within 6.9 years, and 75% within 10 years. Familial AD cases (FAD) had a longer duration than sporadic cases (SAD), especially cases linked to presenilin (PSEN) genes. No significant differences in duration were associated with age, sex, or apolipoprotein E (Apo E) genotype. Duration was reduced in cases with arterial hypertension. Cox regression analysis suggested longer duration was associated with an earlier disease onset and increased senile plaque (SP) and neurofibrillary tangle (NFT) pathology in the orbital gyrus (OrG), CA1 sector of the hippocampus, and nucleus basalis of Meynert (NBM). The data suggest shorter disease duration in SAD and in cases with hypertensive comorbidity. In addition, degree of neuropathology did not influence survival, but spread of SP/NFT pathology into the frontal lobe, hippocampus, and basal forebrain was associated with longer disease duration. © 2014 R. A. Armstrong.
Resumo:
We present a novel approach to the improvement of the bit error rate (BER) in optical communications. We propose a design of advanced optical receiver enhanced by a nonlinear all-optical decision element. As a particular example, we demonstrate a substantial improvement in the BER over the conventional receiver for operation at 40 Gbits/s. © 2006 Optical Society of America.
Resumo:
We analyze theoretically the interplay between optical return-to-zero signal degradation due to timing jitter and additive amplified-spontaneous-emission noise. The impact of these two factors on the performance of a square-law direct detection receiver is also investigated. We derive an analytical expression for the bit-error probability and quantitatively determine the conditions when the contributions of the effects of timing jitter and additive noise to the bit error rate can be treated separately. The analysis of patterning effects is also presented. © 2007 IEEE.
Resumo:
We find the probability distribution of the fluctuating parameters of a soliton propagating through a medium with additive noise. Our method is a modification of the instanton formalism (method of optimal fluctuation) based on a saddle-point approximation in the path integral. We first solve consistently a fundamental problem of soliton propagation within the framework of noisy nonlinear Schrödinger equation. We then consider model modifications due to in-line (filtering, amplitude and phase modulation) control. It is examined how control elements change the error probability in optical soliton transmission. Even though a weak noise is considered, we are interested here in probabilities of error-causing large fluctuations which are beyond perturbation theory. We describe in detail a new phenomenon of soliton collapse that occurs under the combined action of noise, filtering and amplitude modulation. © 2004 Elsevier B.V. All rights reserved.
Resumo:
Background - The objective of this study was to investigate the association between ethnicity and health related quality of life (HRQoL) in patients with type 2 diabetes. Methods - The EuroQol EQ-5D measure was administered to 1,978 patients with type 2 diabetes in the UK Asian Diabetes Study (UKADS): 1,486 of south Asian origin (Indian, Pakistani, Bangladeshi or other south Asian) and 492 of white European origin. Multivariate regression using ordinary least square (OLS), Tobit, fractional logit and Censored Least Absolutes Deviations estimators was used to estimate the impact of ethnicity on both visual analogue scale (VAS) and utility scores for the EuroQol EQ-5D. Results - Mean EQ-5D VAS and utility scores were lower among south Asians with diabetes compared to the white European population; the unadjusted effect on the mean EQ-5D VAS score was −7.82 (Standard error [SE] = 1.06, p < 0.01) and on the EQ-5D utility score was −0.06 (SE = 0.02, p < 0.01) (OLS estimator). After controlling for socio-demographic and clinical confounders, the adjusted effect on the EQ-5D VAS score was −9.35 (SE = 2.46, p < 0.01) and on the EQ-5D utility score was 0.06 (SE = 0.04), although the latter was not statistically significant. Conclusions - There was a large and statistically significant association between south Asian ethnicity and lower EQ-5D VAS scores. In contrast, there was no significant difference in EQ-5D utility scores between the south Asian and white European sub-groups. Further research is needed to explain the differences in effects on subjective EQ-5D VAS scores and population-weighted EQ-5D utility scores in this context.
Resumo:
In this paper, the authors use an exponential generalized autoregressive conditional heteroscedastic (EGARCH) error-correction model (ECM), that is, EGARCH-ECM, to estimate the pass-through effects of foreign exchange (FX) rates and producers’ prices for 20 U.K. export sectors. The long-run adjustment of export prices to FX rates and producers’ prices is within the range of -1.02% (for the Textiles sector) and -17.22% (for the Meat sector). The contemporaneous pricing-to-market (PTM) coefficient is within the range of -72.84% (for the Fuels sector) and -8.05% (for the Textiles sector). Short-run FX rate pass-through is not complete even after several months. Rolling EGARCH-ECMs show that the short and long-run effects of FX rate and producers’ prices fluctuate substantially as are asymmetry and volatility estimates before equilibrium is achieved.
Resumo:
In this letter, we experimentally study the statistical properties of a received QPSK modulated signal and compare various bit error rate (BER) estimation methods for coherent optical orthogonal frequency division multiplexing transmission. We show that the statistical BER estimation method based on the probability density function of the received QPSK symbols offers the most accurate estimate of the system performance.
Resumo:
Background/aim: The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim af this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, the PowerRefractor (PlusOptiX, Germany). Method: The validity and repeatability of the PowerRefractor was compared to: subjective (non-cycloplegic) refraction on 100 adult subjects (mean age 23.8 (SD 5.7) years) and objective autarefractian (Shin-Nippon SRW-5000, Japan) on 150 subjects (20.1 (4.2) years). Repeatability was assessed by examining the differences between autorefractor readings taken from each eye and by re-measuring the objective prescription of 100 eyes at a subsequent session. Results: On average the PowerRefractor prescription was not significantly different from the subjective refraction, although quite variable (difference -0.05 (0.63) D, p = 0.41) and more negative than the SRW-5000 prescription (by -0.20 (0.72) D, p<0.001). There was no significant bias in the accuracy of the instrument with regard to the type or magnitude of refractive error. The PowerRefractor was found to be repeatable over the prescription range of -8.75D to +4.00D (mean spherical equivalent) examined. Conclusion: The PowerRefractor is a useful objective screening instrument and because of its remote and rapid measurement of both eyes simultaneously is able to assess the oculomotor response in a variety of unrestricted viewing conditions and patient types.
Resumo:
Purpose. Whereas many previous studies have identified the association between sustained near work and myopia, few have assessed the influence of concomitant levels of cognitive effort. This study investigates the effect of cognitive effort on near-work induced transient myopia (NITM). Methods. Subjects comprised of six early onset myopes (EOM; mean age 23.7 yrs; mean onset 10.8 yrs), six late-onset myopes (LOM; mean age 23.2 yrs; mean onset 20.0 yrs) and six emmetropes (EMM; mean age 23.8 yrs). Dynamic, monocular, ocular accommodation was measured with the Shin-Nippon SRW-5000 autorefractor. Subjects engaged passively or actively in a 5 minute arithmetic sum checking task presented monocularly on an LCD monitor via a Badal optical system. In all conditions the task was initially located at near (4.50 D) and immediately following the task instantaneously changed to far (0.00 D) for a further 5 minutes. The combinations of active (A) and passive (P) cognition were randomly allocated as P:P; A:P; A:A; P:A. Results. For the initial near task, LOMs were shown to have a significantly less accurate accommodative response than either EOMs or EMMs (p < 0.001). For the far task, post hoc analyses for refraction identified EOMs as demonstrating significant NITM compared to LOMs (p < 0.05), who in turn showed greater NITM than EMMs (p < 0.001). The data show that for EOMs the level of cognitive activity operating during the near and far tasks determines the persistence of NITM; persistence being maximal when active cognition at near is followed by passive cognition at far. Conclusions. Compared with EMMs, EOMs and LOMs are particularly susceptible to NITM such that sustained near vision reduces subsequent accommodative accuracy for far vision. It is speculated that the marked NITM found in EOM may be a consequence of the crystalline lens thinning shown to be a developmental feature of EOM. Whereas the role of small amounts of retinal defocus in myopigenesis remains equivocal, the results show that account needs to be taken of cognitive demand in assessing phenomena such as NITM.